Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Tensor Basis Gaussian Process Models of Hyperelastic Materials

In this study, we develop Gaussian process regression (GPR) models of isotropic hyperelastic material behavior. First, we consider the direct approach of modeling the components of the Cauchy stress tensor as a function of the components of the Finger stretch tensor in a Gaussian process. We then consider an improvement on this approach that embeds rotational invariance of the stress-stretch constitutive relation in the GPR representation. This approach requires fewer training examples and achieves higher accuracy while maintaining invariance to rotations exactly. Finally, we consider an approach that recovers the strain-energy density function and derives the stress tensor from this potential. Although the error of this model for predicting the stress tensor is higher, the strain-energy density is recovered with high accuracy from limited training data. The approaches presented here are examples of physics-informed machine learning. They go beyond purely data-driven approaches by embedding the physical system constraints directly into the Gaussian process representation of materials models.

36 MATERIALS SCIENCE↗

A Survey of Constrained Gaussian Process: Approaches and Implementation Challenges

Gaussian process regression is a popular Bayesian framework for surrogate modeling of expensive data sources. As part of a larger effort in scientific machine learning, many recent works have incorporated physical constraints or other a priori information within Gaussian process regression to supplement limited data and regularize the behavior of the model. We provide an overview and survey of several classes of Gaussian process constraints, including positivity or bound constraints, monotonicity and convexity constraints, differential equation constraints provided by linear PDEs, and boundary condition constraints. We compare the strategies behind each approach as well as the differences in implementation, concluding with a discussion of the computational challenges introduced by constraints.

97 MATHEMATICS AND COMPUTING↗

Status of the LCLS-II Accelerating Cavity Production

Cavity serial production for the LCLS-II 4 GeV CM SRF linac has started. A quantity of 266 accelerating cavities has been ordered from two industrial vendors. Jefferson Laboratory leads the cavity procurement activities for the project and has successfully transferred the Nitrogen-Doping process to the industrial partners in the initial phase, which is now being applied for the production cavities. We report on the results from vendor qualification and the status of the cavity production for LCLS-II.

Daly, Ed↗

Rework Recipe Development, Analysis and Results of Select 9-Cell Cavities for LCLS-II

The SLAC National Accelerator Laboratory is currently constructing a major upgrade to its accelerator, the Linac Coherent Light Source II (LCLS-II). Several Department of Energy laboratories, including the Thomas Jefferson National Accelerator Facility (JLab) and Fermi National Accelerator Laboratory (FNAL), are collaborating in this project. The cryomodules for this project each consist of eight 1.3-GHz cavities produced by two vendors, Research Instruments GmbH in Germany (RI*) and Ettore Zanon S.p.a. in Italy (EZ*), using niobium cell material from Tokyo Denkai Co., Ltd. (TD) and Ningxia Orient Tantalum Industry Co., Ltd. (OTIC/NX)). During the initial production run, cavity performance from one of the vendors (Vendor A) was far below expectation. All the cavities had low Q0, later attributed to minimal EP as well as high-flux-trapping NX material, early quench behaviour below 18 MV/m, with many having Q0 roll-off at 12-16 MV/m. Production was stopped multiple times over the following 6 months, with test batches of cavities being made to ascertain the root cause of the problem. The final root cause of the problem was found to be inappropriate grinding of the RF surface prior to welding which left normal conducting inclusions in the surface. In addition, most cavities showed internal and external weld spatter which required post weld grinding and a very rough surface from operating the electropolishing machine in an etching rather than polishing regime. All issues have been corrected on new cavities and rework is underway on the originally effected cavities.

Macha, Kurt M.↗

Optimizing procurement strategies for LCLS-II

The SLAC National Accelerator Laboratory is currently constructing a major upgrade to its accelerator, the Linac Coherent Light Source II (LCLS-II). Several Department of Energy national laboratories, including the Thomas Jefferson National Accelerator Facility (JLab), are participating in this project. JLab is responsible for procuring a number of critical components. Over the course of this project, JLab has evolved several procurement strategies to minimize risk and improve performance while working within the constraints of budget and schedule. This paper discusses the impact of procurement choices on project technical success.

Wilson, Katherine M.↗

Understanding and Pushing the Limits of Nitrogen Doping

This work will describe Fermilab experiments that focus on the optimization of doping parameters to achieve low sensitivity to trapped magnetic flux while maintaining very high Q characteristic of nitrogen doped cavities and same or higher quench fields. Working partially in the context of LCLS-2 higher energy upgrade, new doping recipes are pursued and have been found to vary the mean free path of the resonator which is related to the sensitivity to trapped magnetic flux. Moreover, a correlation has been found between lighter doping and higher quench fields while maintaining sufficiently low surface resistance.

43 PARTICLE ACCELERATORS↗

Challenges to Reliable Production Nitrogen Doping of Nb for SRF Accelerating Cavities

Over the last several years, alloying of the surface layer of niobium SRF cavities has been demonstrated to beneficially lower the superconducting RF surface resistance. Nitrogen, titanium, and oxygen have all been demonstrated as effective alloying agents, occupying interstitial sites in the niobium lattice within the RF penetration depth and even deeper, when allowed to thermally diffuse into the surface at appropriate temperatures. The use of nitrogen for this function has been often termed ’nitrogen doping’ and is being applied in the LCLS-II and LCLS-II HE projects. We report characterization studies of the distribution of nitrogen into the exposed niobium surface and how such distribution is affected by the quality of the vacuum furnace environment in which the doping takes place, and the complexity of nitride crystal growth on different grain orientations of surface niobium. Using state-of-the-art quantification methods by dynamic secondary ion mass spectrometry (SIMS) depth profiling in niobium, we identify several phenomena involving furnace-sourced contamination. We also highlight a potential issue with N₂ flow constraints from the flange ’caps’ used during heat treatments.

Reece, Charles↗

Modeling O and N Alloying in Nb for SRF Applications

N and O-alloyed superconducting radio frequency cavities exhibit extraordinary quality factors. Developing diffusion models that describe interstitial N and O in Nb is important for optimizing alloyed cavity quality factors and accelerating gradients. N and O-alloyed Nb samples are examined with SEM AND SIMS and their diffusion profiles modeled.

Lechner, Eric↗

Investigation of Low-Level Nitrogen in Niobium by Secondary Ion Mass Spectrometry

Understanding the improvement of the SRF cavity quality factor by low-level nitrogen addition (?N-doping?) is attracting much attention from researchers. Precise, repeatable measurement of the nitrogen profile in the parts-per-thousand to parts-per-million range is vital. Secondary Ion Mass Spectrometry (SIMS) is the approach of choice because of excellent sensitivity and depth resolution. Accurate quantitation must consider sample properties, such as surface topography and crystal structure, calibration of the instrument with reference materials, and data analysis. We report the results of a SIMS study in which polycrystal and single crystal coupons were N-doped, each accompanied by new SRF-grade niobium sheet equivalent to a single cell cavity.

Tuggle, Jay↗

MATERIAL QUALIFICATION OF LCLS-II PRODUCTION NIOBIUM MATERIAL INCLUDING RF AND FLUX EXPULSION MEASUREMENTS ON SINGLE CELL CAVITIES

It has been shown that cooldown details through transition temperature can significantly affect the amount of trapped magnetic flux in SRF cavities, which can lead to performance degradation proportional to the magnitude of the ambient magnetic field.1 It has also more recently been shown that depending on the exact material properties - even when the material used originated from the same batch from the same vendor - and subsequent heat treatment, the percent of flux trapped during a cool-down could vary widely for identical cool-down parameters.2 For LCLS-II, two material vendors have produced half of the niobium used for the cavity cells (Tokyo Denkai Co., Ltd. (TD) and Ningxia Orient Tantalum Industry Co., Ltd. (NX)). Both vendors delivered material well within specifications set out by the project (according to ASTM B 393-05), which allows yet some variation of material characteristics such as grain size and defect density. In this contribution, we present RF and magnetic flux expulsion measurements of four single cell cavities made out of two different niobium batches from each of the two LCLS-II material suppliers and draw conclusions on potential correlations of flux expulsion capability with material parameters. We present observations of limited flux expulsion in cavities made from the production material and treated with the baseline LCLS-II recipe.

Palczewski, Ari↗

Investigation of Nitrogen Absorption Rate and Nitride Growth on SRF Cavity Grade RRR Niobium as a Function of Furnace Temperature

The current state of the art processing of niobium superconducting radio frequency cavities with nitrogen diffusion is performed at 800 C in a furnace with a partial pressure of approximately ~20 mTorr of nitrogen. Multiple studies have shown the bulk of the nitrogen absorbed by the niobium forms a thick (1-3 microns) non-superconducting nitride layer which must be removed to produce optimal RF results. The depth profiling of interstitial nitrogen and surface nitrides has already been probed using SIMS measurements for this recipe. These measurements have been successfully modelled by extrapolating data from nitride growth studies performed at atmospheric pressure and temperatures above 1000 C.1 One open question is whether there is a diffusion-only zone at lower temperature in the ~20 mTorr range in which the niobium will absorb nitrogen but not create a non-superconducting nitride layer; or is the absorption of nitrogen only possible by first forming a nitride buffer layer which then frees up nitrogen for absorption which is what has been shown down to 600 C at atmospheric pressures on long time scales. A systematic study of absorption vs. temperature and correlated SIMS measurements is required to answer this question. We report on measurements of the parabolic rate constant vs. temperature from 400 C to 900 C of cavity grade niobium with metallurgically flat witness samples. Depth profiles of witness samples using SIMS are presented together with SEM imaging for nitride crystals and correlated with N absorption.

Reece, Charles↗

RF Results of Nb Coated SRF Accelerator Cavities via HiPIMS

Bulk Niobium (Nb) SRF (superconducting radio frequency) cavities are currently the preferred method for acceleration of charged particles at accelerator facilities around the world. However, bulk Nb cavities have poor thermal conductance and impose material and design restrictions on other components of a particle accelerator. Since the SRF phenomena occurs within a shallow depth of 40 nm (for Nb), a proposed solution to this problem has been to deposit a superconducting Nb thin film on the interior of a cavity made of a suitable alternative material such as copper or aluminum. While this approach has been attempted in the past using DC magnetron sputtering (DCMS), such cavities have never performed at the bulk Nb level. However, new energetic condensation techniques for film deposition offer the opportunity to create suitably thick Nb films with improved density, microstructure and adhesion compared to traditional DCMS. One such technique that has been developed somewhat recently is ?High Power Impulse Magnetron Sputtering? (HiPIMS). Here we report early results from various thin film coatings carried out on 1.3 GHz Cu cavities, a 1.5 GHz Nb cavity, and small Cu coupon samples coated at Jefferson Lab using HiPIMS.

Burton, Matthew Creed↗

Cavity Processing and Testing Activities at Jefferson Lab for LCLS-II Production

Cryomodule production for LCLS-II is well underway at Jefferson Lab. This paper explains the process flow for production cavities, from being received at the Test Lab to being assembled onto cavity strings. Taking our facility and infrastructure into consideration, process optimization and process control are implemented to ensure high quality products.

Davis, Giles↗

A Cross-Lab Qualification of Modified 120°C Baked Cavities

Within a global effort to understand and standardize the nitrogen-infusion and the low T bake procedure, one large grain and two fine grain single-cell cavity were treated and tested at FNAL and then send to other labs including DESY and JLab for further studies.

43 PARTICLE ACCELERATORS↗

The LCLS-II HE High Q and Gradient R&D Program

The LCLS-II HE project is a high energy upgrade to the superconducting LCLS-II linac. It consists of adding twenty additional 1.3 GHz cryomodules to the linac, with cavities operating at a gradient of 20.8 MV/m with a Q₀ of 2.7·10¹⁰. Performance of LCLS-II cryomodules has suggested that operations at this high of a gradient will not be achievable with the existing cavity recipe employed. Therefore a research program was developed between SLAC, Fermilab, Thomas Jefferson National Accelerator Facility, and Cornell University in order to improve the cavity processing method of the SRF cavities and reach the HE goals. This program explores the doping regime beyond what was done for LCLS-II and also has looked to further developed nitrogen-infusion. Here we will summarize the results from this R\&D program, showing significant improvement on both single-cell and 9-cell cavities compared with the original LCLS-II cavity recipe.

43 PARTICLE ACCELERATORS↗

Study of Flux Trapping Variability between Batches of Tokyo Denkai Niobium used for the LCLS-II Project and Subsequent 9-cell RF Loss Distribution between the Batches

During the LCLS-II project a second batch of niobium was procured from Tokyo Denkai Co Ltd in order to make additional cavities. The original production material came from Two vendors Tokyo Denkai Co., Ltd. (TD) and Ningxia Orient Tantalum Industry Co., Ltd. (OTIC/NX)). It was found TD niobium required a lower annealing temperature (900°C) to obtain satisfactory flux expulsion characteristics compared to NX which required a slightly higher annealing temperature (950°-975°C). In order to ensure the new TD material performed equivalent to the niobium produced 4 year before after 900°C annealing; each heat lot of niobium had its flux expulsion characteristics parametrized and custom thermal treatments developed for each lot. Subsequent pure heat lot 9 cell cavities were made and tested. We will look at the flux expulsion characteristics of each lot, and RF loss of the 9-cell cavities produced using the individual heat lots.

43 PARTICLE ACCELERATORS↗

New Insights in the Quench Mechanisms in Nitrogen Doped Cavities

This paper will cover a systematic study of the quench in nitrogen doped cavities: three cavities were sequentially treated/reset with different doping recipes which are known to produce different levels of quench field. Analysis of mean free path and TMAP coupled with sample analysis reveals new insights on the physics of the premature quench in nitrogen doped cavities; new recipes demonstrate the possibility to increase quench fields well beyond 30 MV/m.

43 PARTICLE ACCELERATORS↗

LCLS-II-HE Vertical Acceptance Testing Plans

LCLS-II-HE has performance requirements similar to but generally more demanding than those of LCLS-II, with an operating gradient of 21 MV/m (up from 16 MV/m in LCLS-II) and tighter restrictions on field emission and multipacting. In this paper, we outline the requirements for the 1.3 GHz cavities and the plans for qualification of these cavities by vertical test. We discuss lessons learned from LCLS-II and highlight the changes implemented in the vertical test procedure for the new project.

43 PARTICLE ACCELERATORS↗