Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

BioCARS: a synchrotron resource for time-resolved X-ray science

BioCARS, a NIH-supported national user facility for macromolecular time-resolved X-ray crystallography at the Advanced Photon Source (APS), has recently completed commissioning of an upgraded undulator-based beamline optimized for single-shot laser-pump X-ray-probe measurements with time resolution as short as 100 ps. The source consists of two in-line undulators with periods of 23 and 27 mm that together provide high-flux pink-beam capability at 12 keV as well as first-harmonic coverage from 6.8 to 19 keV. A high-heat-load chopper reduces the average power load on downstream components, thereby preserving the surface figure of a Kirkpatrick-Baez mirror system capable of focusing the X-ray beam to a spot size of 90 {micro}m horizontal by 20 {micro}m vertical. A high-speed chopper isolates single X-ray pulses at 1 kHz in both hybrid and 24-bunch modes of the APS storage ring. In hybrid mode each isolated X-ray pulse delivers up to {approx}4 x 10{sup 10} photons to the sample, thereby achieving a time-averaged flux approaching that of fourth-generation X-FEL sources. A new high-power picosecond laser system delivers pulses tunable over the wavelength range 450-2000 nm. These pulses are synchronized to the storage-ring RF clock with long-term stability better than 10 ps RMS. Monochromatic experimental capability with Biosafety Level 3 certification has been retained.

43 PARTICLE ACCELERATORS↗

Optical design of the Short Pulse Soft X-ray Spectroscopy beamline at the Advanced Photon Source

The Short Pulse X-ray facility planned for the Advanced Photon Source (APS) upgrade will provide two sectors with photon beams having picosecond pulse duration. The Short Pulse Soft X-ray Spectroscopy (SPSXS) beamline will cover the 150–2000 eV energy range using an APS bending magnet. SPSXS is designed to take full advantage of this new timing capability in addition to providing circular polarized radiation. Since the correlation between time and electron momentum is in the vertical plane, the monochromator disperses in the horizontal plane. The beamline is designed to maximize flux and preserve the time resolution by minimizing the number of optical components. The optical design allows the pulse duration to be varied from 1.5 to 100 ps full width at half-maximum (FWHM) without affecting the energy resolution, and the resolution to be changed with minimal effect on the pulse duration. More than 10 9 photons s -1 will reach the sample with a resolving power of 2000 and a pulse duration of ~2 ps for photon energies between 150 and 1750 eV. The spot size expected at the sample position will vary with pulse duration and exit slit opening. At 900 eV and at a resolving power of 2000 the spot will be ~10 µm × 10 µm with a pulse duration of 2.3 ps FWHM.

47 OTHER INSTRUMENTATION↗

Development of combined microstructure and structure characterization facility for in situ and operando studies at the Advanced Photon Source

Following many years of evolutionary development, first at the National Synchrotron Light Source, Brookhaven National Laboratory, and then at the Advanced Photon Source (APS), Argonne National Laboratory, the APS ultra-small-angle X-ray scattering (USAXS) facility has been transformed by several new developments. These comprise a conversion to higher-order crystal optics and higher X-ray energies as the standard operating mode, rapid fly scan measurements also as a standard operational mode, automated contiguous pinhole small-angle X-ray scattering (SAXS) measurements at intermediate scattering vectors, and associated rapid wide-angle X-ray scattering (WAXS) measurements for X-ray diffraction without disturbing the sample geometry. With each mode using the USAXS incident beam optics upstream of the sample, USAXS/SAXS/WAXS measurements can now be made within 5 min, allowing in situ and operando measurement capabilities with great flexibility under a wide range of sample conditions. Furthermore, these developments are described, together with examples of their application to investigate materials phenomena of technological importance. Developments of two novel USAXS applications, USAXS-based X-ray photon correlation spectroscopy and USAXS imaging, are also briefly reviewed.

47 OTHER INSTRUMENTATION↗

Picosecond-resolved X-ray absorption spectroscopy at low signal contrast using a hard X-ray streak camera

A picosecond-resolving hard-X-ray streak camera has been in operation for several years at Sector 7 of the Advanced Photon Source (APS). Several upgrades have been implemented over the past few years to optimize integration into the beamline, reduce the timing jitter, and improve the signal-to-noise ratio. These include the development of X-ray optics for focusing the X-rays into the sample and the entrance slit of the streak camera, and measures to minimize the amount of laser light needed to generate the deflection-voltage ramp. For the latter, the photoconductive switch generating the deflection ramp was replaced with microwave power electronics. With these, the streak camera operates routinely at 88 MHz repetition rate, thus making it compatible with all of the APS fill patterns including use of all the X-rays in the 324-bunch mode. Sample data are shown to demonstrate the performance.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Pink-beam focusing with a one-dimensional compound refractive lens

The performance of a cooled Be compound refractive lens (CRL) has been tested at the Advanced Photon Source (APS) to enable vertical focusing of the pink beam and permit the X-ray beam to spatially overlap with an 80 µm-high low-density plasma that simulates astrophysical environments. Focusing the fundamental harmonics of an insertion device white beam increases the APS power density; here, a power density as high as 500 W mm –2 was calculated. A CRL is chromatic so it does not efficiently focus X-rays whose energies are above the fundamental. Only the fundamental of the undulator focuses at the experiment. A two-chopper system reduces the power density on the imaging system and lens by four orders of magnitude, enabling imaging of the focal plane without any X-ray filter. As a result, a method to measure such high power density as well as the performance of the lens in focusing the pink beam is reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Establishment of new design criteria for GlidCop ® X-ray absorbers

Here, an engineering research program has been conducted at the Advanced Photon Source (APS) in order to determine the thermomechanical conditions that lead to crack formation in GlidCop ® , a material commonly used to fabricate X-ray absorbers at X-ray synchrotron facilities. This dispersion-strengthened copper alloy is a proprietary material and detailed technical data of interest to the synchrotron community is limited. The results from the research program have allowed new design criteria to be established for GlidCop ® X-ray absorbers based upon the thermomechanically induced fatigue behavior of the material. X-ray power from APS insertion devices was used to expose 30 GlidCop ® samples to 10000 thermal loading cycles each under various beam power conditions, and all of the samples were metallurgically examined for crack presence/geometry. In addition, an independent testing facility was hired to measure temperature-dependent mechanical data and uniaxial mechanical fatigue data for numerous GlidCop ® samples. Data from these studies support finite element analysis (FEA) simulation and parametric models, allowing the development of a thermal fatigue model and the establishment of new design criteria so that the thermomechanically induced fatigue life of X-ray absorbers may be predicted. It is also demonstrated how the thermal fatigue model can be used as a tool to geometrically optimize X-ray absorber designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data management and processing workflow for the Materials Physics and Engineering group beamlines at the Advanced Photon Source

The ability to store, organize, process and distribute experimental data effectively, efficiently and securely is particularly important for large user facilities like the Advanced Photon Source. In this article, the deployment of the APS Data Management System (DM) at the 1-ID and 6-BM beamlines of the APS is described. These two beamlines support a wide range of experimental techniques and generate data at relatively high rates, making them ideal candidates to illustrate the deployment and customization of the DM system and its tools. Using several usage examples at these beamlines, various capabilities of the DM system are described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Demand Driven Energy Management for PIPO Auxiliary Power Supply Architecture

In this paper, a demand driven energy management (DDEM) technique is implemented on modular parallel input parallel output DC/DC auxiliary power supply (APS) structure. In this method, modules are brought in/out of the operation making them operate under high loading conditions, avoiding low efficiency under light load. Such a method finds its application in power conservative systems with variable load. Implementation of DDEM and the energy saved is shown using APS comprised of two 15W commercially off-the-shelf DC-DC modules, with 100–1000 VDC input and 24 V output voltage. Along with the DDEM, the lifetime of the power stage devices is controlled minimizing their junction temperature swing through control of cooling system. This control method uses digital twin as interface to virtualize the power devices loading operation/ health condition. Accordingly, no extra sensor or closed loop control required to measure the junction temperature of the devices or feedback the losses to the cooling flow.

Azadeh, Yalda↗

Development of Short-Period Nb 3 Sn Superconducting Planar Undulators

NbTi-based superconducting undulators (SCUs) have been developed and proven to increase the brightness by an order of magnitude at high X-ray energies at the ANL's Advanced Photon Source (APS). Nb 3 Sn has the potential to further enhance the performance of SCUs. A new project, aiming to fabricate a full-length, 3-m-long Nb 3 Sn SCU, compatible with the storage ring, has started at the APS. To develop the technology, three Nb 3 Sn short prototype magnets were fabricated and tested in liquid helium. These prototypes were used to incrementally improve the original design. The final short model magnet reached 100% of the short sample limit. Here, the achieved current level in this magnet is 75% higher than what an NbTi wire can deliver.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal Analysis of a Helical Superconducting Undulator Cryostat

A novel cryocooler-cooled helical superconducting undulator (HSCU) was built and installed in the Advanced Photon Source (APS) storage ring and has been in operation since January 2018. The new cryostat for the HSCU is a major improvement of the cryogenic system used for the existing APS planar superconducting undulators. In both systems, superconducting magnets are cooled independently from the beam chamber by liquid helium (LHe) passing through a channel in the magnet/mold assembly. The original planar undulator cryostat consists of three thermal circuits: the outer shield circuit to cool both the warm part of the magnet current leads and the outer shield, the beam chamber cooling circuit to cool the beam chamber and the inner shield, and the magnet cooling circuit to cool the magnets and the LHe tank. On the other hand, the new system consists of only two thermal circuits: the thermal shield circuit to cool the beam chamber, the shield, and the warm part of the magnet leads; and the magnet cooling circuit to cool the LHe tank and the magnet/mold assembly. An finite element analysis-based thermal model of the new HSCU cryostat was developed while the cryogenic performance of the HSCU was measured in a series of standalone tests as well as after installation in the storage ring. This paper presents a thermal analysis of the new HSCU cryostat and, in particular, a comparison of calculated and measured temperatures as well as the excess cooling capacity of the new cryostat in static and dynamic (beam-induced heating) modes.

cryocooler↗

Heat Treatment Studies of Nb3Sn Wires for Superconducting Planar Undulators

A project aiming to fabricate a full-length 2.8-m long Nb 3Sn superconducting undulator for the storage ring was started last year at the ANL APS. These Nb 3 Sn undulators operate at a maximum magnetic field on the conductor of about 5 T. To address instabilities at this field, two Nb 3 Sn wires with small subelement size were used. Specifically, Restacked Rod Processed wires of 0.6mmin diameter and with 144 and 150 superconducting subelements respectively, over 169 total. The equivalent subelement diameter, DS, of thesewires is35 mu m. At these smallDS values, the critical current density is known to deteriorate, and the Residual Resistivity Ratio is very sensitive to heat treatment. A delicate balance has therefore to be found to obtain parameters within operation specifications. In this paper we showperformance results from different heat treatments.

critical current density↗

Characterization of NbTi busbar for HL LHC Interaction Region Quadrupoles

The US Accelerator Upgrade for the HiLumi-LHC (US-HL-LHC AUP) project and CERN are designing and fabricating superconducting quadrupole magnets for the interaction regions of the High Luminosity Large Hadron Collider (HLLHC). The triplet is made of three optical elements: Q1, Q2, and Q3. The Nb3Sn quadrupole magnets operate in superfluid He at 1.9 K with a nominal field gradient of 132.6 T/m. The three inner triplet elements are connected together with superconducting buses. The design and fabrication of the through and local buses is carried out at Applied Physics and Superconducting Technology Division (APS-TD) at Fermilab (FNAL). This paper reports the characterization of the bus-bar thermoelectric properties. The bus was tested with a short Nb3Sn magnet (MQXFS1e) in the vertical test facility of the APS-TD at FNAL. The test demonstrated that the bus design is adequate since no spontaneous quench took place up to 17.87 kA current value. Quench propagation velocities were investigated over a range of currents that is typical for accelerator superconducting magnets. Temperature margins were found above that required for the Hi- Lumi triplet bus. The design guarantees the protection of the bus at operational current value according to the quench detection voltage threshold (100 mV) established for the Hi-Lumi LHC interaction region.

43 PARTICLE ACCELERATORS↗

Fabrication and Testing of 18-mm-Period, 0.5-m-Long Nb 3 Sn Superconducting Undulator

The Advanced Photon Source at Argonne National Laboratory, in collaboration with FNAL and LBNL, is developing a Nb 3 Sn superconducting undulator with the goal of installing this device on the APS storage ring and providing APS users with the novel radiation source. A series of short, similar to ~ 8-cm-long, 18-mm-period undulator prototype magnets have been designed, fabricated, and tested. The same design was scaled to fabricate a 0.5-m-long undulator prototype. Tests of this prototype showed that the designed peak magnetic field of 1.2 T at 850 A was successfully achieved. It represents at least a 20% improvement in comparison with a NbTi SCU having the same period and magnetic gap. Test results and lessons learned from the design process are reported here.

43 PARTICLE ACCELERATORS↗

Beamline Spectroscopy of Integrated Circuits With Hard X-Ray Transition Edge Sensors at the Advanced Photon Source

At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to semiconductor-based energy-dispersive detectors, but with better collection efficiency than wavelength-dispersive instruments, will enable greatly improved X-ray emission and absorption spectroscopic measurements. Additionally, a prototype instrument with 24 microwave-frequency multiplexed pixels is now in testing at the Advanced Photon Source (APS) 1-BM beamline. Initial measurements show an energy resolution ten times better (150 eV compared to < 15 eV) than the silicon-drift detectors currently available to APS beamline users, and in particular demonstrate the ability to resolve closely-spaced emission lines in samples containing multiple transition metal elements, such as integrated circuits. Comparing fluorescence spectra of integrated circuits measured with our TESs at the beamline to those measured with silicon detectors, we find emission lines and elements largely hidden (e.g. Hf alongside Cu) from a semiconductor-based detector but well resolved by a TES. This directly shows the strengths of TES-based instruments in fluorescence mapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cryogenic System Preliminary Design for a 0.5m-Long, Conduction-Cooled Nb3Sn Undulator Magnet Prototype

There are several NbTi superconducting undulator (SCU) magnets currently in operation at the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The development on Nb3Sn-based superconducting undulator magnets at APS is underway due to the potential to further enhance the performance of the SCUs. Superconducting undulator magnets need to keep temperature gradients minimized in order to retain thermal and operating current margin. We have designed the thermal links for efficient heat conduction using 3D finite element analysis (FEA) simulation in COMSOL Multiphysics software, which was later used for the calculation of the temperature distribution across a 0.5 m long, conduction-cooled, Nb3Sn undulator magnet prototype that includes both conductive heat transfer and radiative heating components. We have modelled the evolution of the thermal properties of the magnet winding as well as other cold parts during cool-down from ambient temperature with the operation of a SHI RDK-415D cryocooler to examine the estimated time that is needed for the cooldown as well as the baseline temperature we could achieve. A key result was that a maximum coil delta T = 0.11 K along the designed thermal links and a temperature range of 3.42 K-3.53 K for the winding were predicted at steady state. A pair of G10 support rods for carrying the magnet as well as a pair of current leads made of metals were also designed and optimized for the testing system, targeting for an operation temperature of 4 K and a coil current of 950 A DC.

Zhang, Danlu↗

Fabrication and Test of C3a: A Six-Layer Subscale Canted $\cos \theta$ Dipole Magnet Using High-Temperature Superconducting corc Wires

REBCO coated conductors have a strong potential for high-field magnet applications. The REBCO technology, however, is still in its infancy for accelerator magnet applications. As part of the U.S. Magnet Development Program (MDP), we developed a six-layer canted cos θ dipole magnet, C3a, using CORC® wires developed by Advanced Conductor Technologies LLC. All the layers were wound using a semi-automated winding machine. Three layers of the magnet used CORC® wires containing the SuperPower “AP” REBCO tapes and the remaining layers used the wires containing the “HM” tapes. At 77 K, both kinds of CORC® wires showed 5% to 10% degradation, after bending to a minimum bend radius of 30 or 35 mm, with respect to the self-field critical current measured before winding. At 4.2 K, the magnet reached 9.5 kA at a ramp rate of 9 A s -1 and generated a dipole field of 1.4 T. Further, the critical current of one layer degraded by 4% after a current transient up to 10.5 kA ramped in an averaged rate of 175 kA s -1 or 20 T s -1 . We confirmed the HM CORC® wire can carry a higher current than the AP CORC® wire at 4.2 K. The test results of the C3a magnet showed that the fabrication and assembly procedure can be used for the upcoming full-scale C3 magnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectral and Spatial Classification of Hyperspectral Images Based on ICA and Reduced Morphological Attribute Profiles

The availability of hyperspectral images with improved spectral and spatial resolutions provides the opportunity to obtain accurate land-cover classification. In this paper, a novel methodology that combines spectral and spatial information for supervised hyperspectral image classification is proposed. A feature reduction strategy based on independent component analysis is the main core of the spectral analysis, where the exploitation of prior information coupled to the evaluation of the reconstruction error assures the identification of the best class-informative subset of independent components. Reduced attribute profiles (APs), which are designed to address well-known issues related to information redundancy that affect the common morphological APs, are then employed for the modeling and fusion of the contextual information. Four real hyperspectral data sets, which are characterized by different spectral and spatial resolutions with a variety of scene typologies (urban, agriculture areas), have been used for assessing the accuracy and generalization capabilities of the proposed methodology. The obtained results demonstrate the classification effectiveness of the proposed approach in all different scene typologies, with respect to other state-of-the-art techniques.

42 ENGINEERING↗

Genetic Identification of Lamprey Genera and Anadromous Ecotypes in Watersheds of the Northeastern Pacific Ocean

ABSTRACT Nonparasitic, nonmigratory Western Brook Lamprey (WBL; Lampetra ayresii ), and parasitic, anadromous Western River Lamprey (WRL; L. ayresii ) are sympatric lampreys that likely represent different life history variations of a single species. Novel genetic tools are critical for differentiating WBL and WRL, whose larvae preclude morphological identification (ID) and will enable comprehensive assessment of imperiled native lampreys of the Northeastern Pacific (including WBL, WRL, and Pacific Lamprey, Entosphenus tridentatus ). We developed 47 candidate single nucleotide polymorphism (SNP) markers using whole genome resequencing of WBL ( N = 24) and WRL ( N = 15) from Ksi Ts'oohl Ts'ap Creek (Nass River, British Columbia, Canada) which are likely ecotypes distinguished by few divergent SNPs across multiple chromosomes. We used five novel candidate SNPs to perform genetic ID of WBL and WRL ecotypes in collections of mixed native lampreys from lower Columbia River tributaries ( N = 1474), Ksi Ts'oohl Ts'ap Creek ( N = 352), and ocean phase WRL from the Georgia Basin (Salish Sea, British Columbia, Canada; N = 91). Two previously published SNPs were used to ID genera, Entosphenus versus Lampetra . Morphological ID utilized photographs collected from a subset of genotyped lampreys, and high concordance was demonstrated between ID methods for genera (99%) and Lampetra ecotypes (> 98%). We characterized spatial and temporal composition of lamprey genera and ecotypes surveyed across NE Pacific tributaries under the expectation these compositions would be similar across nearby sites and across years at the same site. Proportions of lamprey genera were highly variable within regions and across years; however, Lampetra ecotypic proportions were spatially and temporally stable. WRL were rare in lower Columbia tributaries (~1% average rate among Lampetra ) and common further north (> 40% of Lampetra ). Genetic ID methods are powerful monitoring tools that create the novel ability to ascertain genera and ecotypes regardless of life stage, while increasing the efficiency of surveys by eliminating time‐intensive morphological data collection.

Silver, G. S. [Columbia River Inter‐Tribal Fish Co↗