Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Detailed chemistry modeling of rotating detonations with dilute n -heptane sprays and preheated air

Utilization of liquid fuels is crucial to enabling commercialization of rotating detonation engines (RDE) in the near future. In this study, Eulerian-Lagrangian simulations are conducted for rotating detonative combustion with dilute n-heptane sprays and preheated air. Two-dimensional flattened configuration is used and a skeletal chemical mechanism with 44 species and 112 elementary reactions for n-heptane combustion is adopted. The flow structure, droplet distribution, and thermochemical parameters in the refill zone are first analyzed. It is shown that the mixture in the refill zone is heterogeneous, including evaporating droplets, vapor, and air. When the total temperature is below 950 K, the average equivalence ratio increases with the total temperature. When it is higher than 950 K, the average equivalence ratio is almost constant. Subsequently, the chemical explosive mode analysis is applied to identify the controlling reactions and dominant combustion modes in the fuel refill zone and reaction fronts. Results demonstrate that the initiation reaction (R104: n-C 7 H 16 + O 2 2-C 7 H 15 + HO 2 ) and low-temperature reaction (R107: RO 2 R'O 2 H) are dominant in the upstream and downstream of the refill zone, respectively. The intermediate species from low-temperature chemistry, R'O 2 H, is found to be important for the chemical explosive mode in the undetonated mixture. The influence of species diffusion and dispersed droplets is further analyzed. Results show that vapor autoignition facilitated by droplet evaporation occurs in the refill zone. Finally, the effects of the air total temperature on the detonation propagation speed and RDE propulsion performance are investigated. Further, it is found that the detonation propagation speed and specific impulse increase with air total temperature. The total pressure ratio first increases and then decreases as the air total temperature increases. Moreover, when the total temperature of the preheated air is above 1,300 K, the effects of low-temperature chemistry are negligible.

33 ADVANCED PROPULSION SYSTEMS↗

Ultra-fast microwave regeneration of CO 2 solid sorbents for energy-efficient direct air capture

Large-scale deployment of direct air capture (DAC) technologies has become critical for mitigating climate change. Towards this end, energy-efficient regeneration of the sorbents used in the process of carbon capture from air is very important to significantly reduce the high operational cost of DAC. Guanidine compounds can be used with environmentally friendly aqueous amino acids (e.g., potassium sarcosinate) for fast and effective CO 2 capture from air, and have a strong potential for low-energy CO 2 release and sorbent regeneration. In this process, the amino acid absorbs the CO 2 from the air, and the guanidine compounds react with the CO 2 -rich amino acid solution and crystallize as an insoluble carbonate salt. Separation and thermal regeneration of the precipitated guanidine carbonate salt leads to an overall low-temperature and low-energy direct air capture process. Effective CO 2 release from the solid guanidine compound can be achieved by mild heating at 120 °C. Here, in this study, to overcome the relatively inefficient traditional conductive heating of the crystalline solid (i.e., Methylglyoxal-bis(iminoguanidine) carbonate, MGBIG carbonate), we evaluated the feasibility of microwave heating of MGBIG carbonate in terms of power requirement, radiation time, and solids mass for efficient CO 2 desorption. The energy consumption needed by a microwave oven and a conventional oven to regenerate the same mass of the sorbent was directly measured to compare the total energy required per unit mass of regenerated sample and provide an understanding of the potential benefits of microwave regeneration. We found that microwave heating effectively regenerates MGBIG carbonate, which may be facilitated by the water molecules that are co-crystallized with carbonate in the guanidine crystals. Microwave heating at 2.54 GHz with 1250 W is up to 17 times faster than conventional conductive heating at 160 °C, resulting in 40 % electrical energy reduction. These results indicate that microwave regeneration may be an energy-efficient method for fast regeneration of solid sorbents used for direct air capture.

42 ENGINEERING↗

Do Surface and Air Temperatures Contain Similar Imprints of Evaporative Conditions?

Abstract Generally, surface and air temperatures seem closely related but we show that they respond differently to evaporative conditions. We evaluate the temperature increase in response to solar radiation for different evaporative fractions, using observations from the Southern Great Plains. The warming rate of air temperature decreases only by 1.7 × 10 −3 K/(W m −2 ) from dry to moist conditions compared to a stronger reduction by 14 × 10 −3 K/(W m −2 ) for surface temperature. The weaker response of air temperature to evaporative fraction is explained by the larger growth of boundary layer on drier days, which suppresses the warming of air. Estimates based on this explanation reproduce the warming rate of air temperature in observations. Our results show that diurnal variations of surface temperatures contain imprints of evapotranspiration while air temperatures do not. These findings appear important to be considered when using, analyzing, or interpreting temperature data in studies dealing with climate change, hydrology, or land‐atmosphere interactions.

Panwar, Annu↗

Characterizing Greater Houston's Aerosol by Air Mass During TRACER

During the TRacking Aerosol and Convection interaction ExpeRiment (TRACER), a suite of aerosol and cloud measurements were made using the Texas A&M Rapid Onsite Atmospheric Measurement Van (ROAM-V) mobile instrument platform. Joint ROAM-V/radiosonde deployments focused on sampling polluted marine and continental air masses to understand summertime convection along and across the sea-breeze front as it propagated through Houston. The polluted marine air mass at Seawolf Park, Galveston, TX was defined by two characteristic aerosol populations. Although the background total particle concentrations averaged 2,500 cm −3 , the air mass was also influenced by frequent but irregular periods of ship emission with significantly higher aerosol concentrations at times exceeding 34,000 cm −3 . Ship emission influenced periods, typically lasting <10 min, contained smaller, less hygroscopic particles resulting in a 69% relative decline in cloud condensation nuclei (CCN) activated fraction at 1% supersaturation compared to background periods. Measurements in continental air masses northwest of Houston revealed an average aerosol concentration of 5,208 cm −3 with a κ value near 0.1 reasonably describing the CCN population, independent of particle size. In continental air masses, substantial differences in particle size and CCN activation over small distances (<42 miles between sites) suggest considerable site-to-site variability in addition to the expected day-to-day differences. This small-scale variability makes it difficult to generalize continental air mass aerosol properties. Both coastal and inland locations had effective ice nucleating particles, but inland deployments observed the warmest nucleation temperature at −15.6°C compared to −17.8°C close to the coast. These measurements can reduce uncertainties in regional convection allowing models to improve understanding of aerosol-cloud interactions.

54 ENVIRONMENTAL SCIENCES↗

Air, surface, and wastewater surveillance of SARS-CoV-2; a multimodal evaluation of COVID-19 detection in a built environment

Environmental surveillance of infectious organisms holds tremendous promise to reduce human-to-human transmission in indoor spaces through early detection. In this study we determined the applicability and limitations of wastewater, indoor high-touch surfaces, in-room air, and rooftop exhaust air sampling methods for detecting SARS-CoV-2 in a real world building occupied by residents recently diagnosed with COVID-19. We concurrently examined the results of three 24-hour environmental surveillance techniques, indoor surface sampling, exhaust air sampling and wastewater surveillance, to the known daily census fluctuations in a COVID-19 isolation dormitory. Additionally, we assessed the ability of aerosol samplers placed in the large volume lobby to detect SARS-CoV-2 multiple times per day. Our research reveals an increase in the number of individuals confirmed positive with COVID-19 as well as their estimated human viral load to be associated with statistically significant increases in viral loads detected in rooftop exhaust aerosol samples (p = 0.0413), wastewater samples (p = 0.0323,), and indoor high-touch surfaces (p < 0.001)). We also report that the viral load detected in lobby aerosol samples was statistically higher in samples collected during presence of occupants whose COVID-19 diagnostic tests were confirmed positive via qPCR compared to periods when the lobby was occupied by either contact-traced (suspected positive) individuals or during unoccupied periods (p = 0.0314 and <2e–16). We conclude that each daily (24h) surveillance method, rooftop exhaust air, indoor high-touch surfaces, and wastewater, provide useful detection signals for building owner/operator(s). Furthermore, we demonstrate that exhaust air sampling can provide spatially resolved signals based upon ventilation exhaust zones. Additionally, we find that indoor lobby air sampling can provide temporally resolved signals useful during short duration sampling periods (e.g., 2-4 hours) even with intermittent occupancy by occupants diagnosed with COVID-19.

60 APPLIED LIFE SCIENCES↗

Impact of air exposure and surface chemistry on Li-Li 7 La 3 Zr 2 O 12 interfacial resistance

Li 7 La 3 Zr 2 O 12 (LLZO) is a promising solid-state electrolyte that could enable solid-state-batteries (SSB) employing metallic Li anodes. For a SSB to be viable, the stability and charge transfer kinetics at the Li–LLZO interface should foster facile plating and stripping of Li. Contrary to these goals, recent studies have reported high Li–LLZO interfacial resistance which was attributed to a contamination layer that forms upon exposure of LLZO to air. This study clarifies the mechanisms and consequences associated with air exposure of LLZO; additionally, strategies to minimize these effects are described. First-principles calculations reveal that LLZO readily reacts with humid air; the most favorable reaction pathway involves protonation of LLZO and formation of Li2CO3. X-ray photoelectron spectroscopy, scanning electron microscopy, Raman spectroscopy, and transmission electron microscopy were used to characterize the surface and subsurface chemistry of LLZO as a function of relative humidity and exposure time. Additionally, electrochemical impedance spectroscopy was used to measure the Li–LLZO interfacial resistance as a function of surface contamination. These data indicate that air exposure-induced contamination impacts the interfacial resistance significantly, when exposure time exceeds 24 h. The results of this study provide valuable insight into the sensitivity of LLZO to air and how the effects of air contamination can be reversed.

36 MATERIALS SCIENCE↗

Cooling performance of direct expansion system using multiple stages and adjustable heat exchange areas for fresh air handling

Providing fresh air to rooms can ensure indoor air quality. The direct expansion fresh air handling units are widely used, and most of them are single-stage treatment units, which are less energy-efficient under variable operating conditions. To overcome the shortcomings of existing systems, a direct expansion system using multiple stages and adjustable heat exchange areas for fresh air handling is proposed in this study. The fresh air is handled by coils stage by stage to achieve high efficiency, and the dampers of the idle coils are opened when some of the coils are working, which results in the performance improvement under partial load conditions. The simulation model is established, and operating conditions at load ratio of 95.70%, 45.38%, 31.76% and 0 are selected as typical operating conditions. The proposed system performances under different conditions are compared with traditional system. The results show that: (1) For four conditions, as the load rate decreases, the proposed system can save energy by 6.2%, 26.1%, 46.5%, and 25.0% compared to the traditional system respectively; (2) The proposed system can bypass the filter when the outdoor air is good, which can further save energy by 1.3%, 1.8%, 3.4%, and 25.9% under four conditions, respectively.

Zha, Fuhai↗

Development Of Chemical Reduction And Air Stripping Processes To Remove Mercury From Wastewater

This study evaluates the removal of mercury from wastewater using chemical reduction and air stripping using a full-scale treatment system at the Savannah River Site. The existing water treatment system utilizes air stripping as the unit operation to remove organic compounds from groundwater that also contains mercury (C ~ 250 ng/L). The baseline air stripping process was ineffective in removing mercury and the water exceeded a proposed limit of 51 ng/L. To test an enhancement to the existing treatment modality a continuous dose of reducing agent was injected for 6-hours at the inlet of the air stripper. This action resulted in the chemical reduction of mercury to Hg(0), a species that is removable with the existing unit operation. During the injection period a 94% decrease in concentration was observed and the effluent satisfied proposed limits. The process was optimized over a 2-day period by sequentially evaluating dose rates ranging from 0.64X to 297X stoichiometry. A minimum dose of 16X stoichiometry was necessary to initiate the reduction reaction that facilitated the mercury removal. Competing electron acceptors likely inhibited the reaction at the lower 1 doses, which prevented removal by air stripping. These results indicate that chemical reduction coupled with air stripping can effectively treat large-volumes of water to emerging part per trillion regulatory standards for mercury.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LIQUID AIR COMBINED CYCLE

Hybrid integration of thermal energy storage with gas turbines can provide compact, cost-effective, long-duration energy storage while reducing the fuel consumption of dispatchable resources needed for the reliability of renewable dominant electric grids. The Liquid Air Combined Cycle™ (LACC) is a hybrid energy storage system using cryogenic liquid air as an energy storage medium and gas turbine exhaust heat to extract stored energy. The storage tank is charged using liquefaction processes employing electric motor-driven compressors to pressurize the air, heat exchangers to reject heat of compression, and expanders to reduce the temperature and liquefy the air. Proven cryogenic refrigeration processes can be selected based on capital cost (per kg/s of liquid air produced), efficiency (kJ per kg of air produced), and operating factors including startup speed and load following capability. This paper presents results of studies undertaken for the U.S. Department of Energy to evaluate cost and performance tradeoffs for charge and discharge cycle components, optimize charge and discharge cycles, and assess the techno-economic potential of LACC technology.

Conlon, William↗

Dosimetric effects of an air cavity for the SAVI partial breast irradiation applicator

Purpose: To investigate the dosimetric effect of the air inside the SAVI partial breast irradiation device. Methods: The authors have investigated how the air inside the SAVI partial breast irradiation device changes the delivered dose from the homogeneously calculated dose. Measurements were made with the device filled with air and water to allow comparison to a homogenous dose calculation done by the treatment planning system. Measurements were made with an ion chamber, TLDs, and film. Monte Carlo (MC) simulations of the experiment were done using the EGSnrc suite. The MC model was validated by comparing the water-filled calculations to those from a commercial treatment planning system. Results: The magnitude of the dosimetric effect depends on the size of the cavity, the arrangement of sources, and the relative dwell times. For a simple case using only the central catheter of the largest device, MC results indicate that the dose at the prescription point 1 cm away from the air-water boundary is about 9% higher than the homogeneous calculation. Independent measurements in a water phantom with a similar air cavity gave comparable results. MC simulation of a realistic multidwell position plan showed discrepancies of about 5% on average at the prescription point for the largest device. Conclusions: The dosimetric effect of the air cavity is in the range of 3%-9%. Unless a heterogeneous dose calculation algorithm is used, users should be aware of the possibility of small treatment planning dose errors for this device and make modifications to the treatment delivery, if necessary.

60 APPLIED LIFE SCIENCES↗

Comparison of air-kerma strength determinations for HDR {sup 192}Ir sources

Purpose: To perform a comparison of the interim air-kerma strength standard for high dose rate (HDR) {sup 192}Ir brachytherapy sources maintained by University of Wisconsin Accredited Dosimetry Calibration Laboratory (UWADCL) with measurements of the various source models using modified techniques from the literature. The current interim standard was established by Goetsch et al. in 1991 and has remained unchanged to date. Methods: The improved, laser-aligned seven-distance apparatus of University of Wisconsin Medical Radiation Research Center (UWMRRC) was used to perform air-kerma strength measurements of five different HDR {sup 192}Ir source models. The results of these measurements were compared with those from well chambers traceable to the original standard. Alternative methodologies for interpolating the {sup 192}Ir air-kerma calibration coefficient from the NIST air-kerma standards at {sup 137}Cs and 250 kVp x rays (M250) were investigated and intercompared. As part of the interpolation method comparison, the Monte Carlo code EGSnrc was used to calculate updated values of A{sub wall} for the Exradin A3 chamber used for air-kerma strength measurements. The effects of air attenuation and scatter, room scatter, as well as the solution method were investigated in detail. Results: The average measurements when using the inverse N{sub K} interpolation method for the Classic Nucletron, Nucletron microSelectron, VariSource VS2000, GammaMed Plus, and Flexisource were found to be 0.47%, -0.10%, -1.13%, -0.20%, and 0.89% different than the existing standard, respectively. A further investigation of the differences observed between the sources was performed using MCNP5 Monte Carlo simulations of each source model inside a full model of an HDR 1000 Plus well chamber. Conclusions: Although the differences between the source models were found to be statistically significant, the equally weighted average difference between the seven-distance measurements and the well chambers was 0.01%, confirming that it is not necessary to update the current standard maintained at the UWADCL.

61 RADIATION PROTECTION AND DOSIMETRY↗

Alpha image reconstruction (AIR): A new iterative CT image reconstruction approach using voxel-wise alpha blending

Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. Among vendors and researchers, however, there is no consensus of how to best achieve these aims. The general approach is to incorporatea priori knowledge into iterative image reconstruction, for example, by adding additional constraints to the cost function, which penalize variations between neighboring voxels. However, this approach to regularization in general poses a resolution noise trade-off because the stronger the regularization, and thus the noise reduction, the stronger the loss of spatial resolution and thus loss of anatomical detail. The authors propose a method which tries to improve this trade-off. The proposed reconstruction algorithm is called alpha image reconstruction (AIR). One starts with generating basis images, which emphasize certain desired image properties, like high resolution or low noise. The AIR algorithm reconstructs voxel-specific weighting coefficients that are applied to combine the basis images. By combining the desired properties of each basis image, one can generate an image with lower noise and maintained high contrast resolution thus improving the resolution noise trade-off. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and low contrast disks is simulated. A filtered backprojection (FBP) reconstruction with a Ram-Lak kernel is used as a reference reconstruction. The results of AIR are compared against the FBP results and against a penalized weighted least squares reconstruction which uses total variation as regularization. The simulations are based on the geometry of the Siemens Somatom Definition Flash scanner. To quantitatively assess image quality, the authors analyze line profiles through resolution patterns to define a contrast factor for contrast-resolution plots. Furthermore, the authors calculate the contrast-to-noise ratio with the low contrast disks and the authors compare the agreement of the reconstructions with the ground truth by calculating the normalized cross-correlation and the root-mean-square deviation. To evaluate the clinical performance of the proposed method, the authors reconstruct patient data acquired with a Somatom Definition Flash dual source CT scanner (Siemens Healthcare, Forchheim, Germany). Results: The results of the simulation study show that among the compared algorithms AIR achieves the highest resolution and the highest agreement with the ground truth. Compared to the reference FBP reconstruction AIR is able to reduce the relative pixel noise by up to 50% and at the same time achieve a higher resolution by maintaining the edge information from the basis images. These results can be confirmed with the patient data. Conclusions: To evaluate the AIR algorithm simulated and measured patient data of a state-of-the-art clinical CT system were processed. It is shown, that generating CT images through the reconstruction of weighting coefficients has the potential to improve the resolution noise trade-off and thus to improve the dose usage in clinical CT.

60 APPLIED LIFE SCIENCES↗

MO-D-213-07: RadShield: Semi- Automated Calculation of Air Kerma Rate and Barrier Thickness

Purpose: To develop the first Java-based semi-automated calculation program intended to aid professional radiation shielding design. Air-kerma rate and barrier thickness calculations are performed by implementing NCRP Report 147 formalism into a Graphical User Interface (GUI). The ultimate aim of this newly created software package is to reduce errors and improve radiographic and fluoroscopic room designs over manual approaches. Methods: Floor plans are first imported as images into the RadShield software program. These plans serve as templates for drawing barriers, occupied regions and x-ray tube locations. We have implemented sub-GUIs that allow the specification in regions and equipment for occupancy factors, design goals, number of patients, primary beam directions, source-to-patient distances and workload distributions. Once the user enters the above parameters, the program automatically calculates air-kerma rate at sampled points beyond all barriers. For each sample point, a corresponding minimum barrier thickness is calculated to meet the design goal. RadShield allows control over preshielding, sample point location and material types. Results: A functional GUI package was developed and tested. Examination of sample walls and source distributions yields a maximum percent difference of less than 0.1% between hand-calculated air-kerma rates and RadShield. Conclusion: The initial results demonstrated that RadShield calculates air-kerma rates and required barrier thicknesses with reliable accuracy and can be used to make radiation shielding design more efficient and accurate. This newly developed approach differs from conventional calculation methods in that it finds air-kerma rates and thickness requirements for many points outside the barriers, stores the information and selects the largest value needed to comply with NCRP Report 147 design goals. Floor plans, parameters, designs and reports can be saved and accessed later for modification and recalculation. We have confirmed that this software accurately calculates air-kerma rates and required barrier thicknesses for diagnostic radiography and fluoroscopic rooms.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-64: An Alternative Approach to Determining the Reference Air-Kerma Rate from Extrapolation Chamber Measurements

Purpose: Since 2008 the Physikalisch-Technische Bundesanstalt (PTB) has been offering the calibration of {sup 125}I-brachytherapy sources in terms of the reference air-kerma rate (RAKR). The primary standard is a large air-filled parallel-plate extrapolation chamber. The measurement principle is based on the fact that the air-kerma rate is proportional to the increment of ionization per increment of chamber volume at chamber depths greater than the range of secondary electrons originating from the electrode x{sub 0}. Methods: Two methods for deriving the RAKR from the measured ionization charges are: (1) to determine the RAKR from the slope of the linear fit to the so-called ’extrapolation curve’, the measured ionization charges Q vs. plate separations x or (2) to differentiate Q(x) and to derive the RAKR by a linear extrapolation towards zero plate separation. For both methods, correcting the measured data for all known influencing effects before the evaluation method is applied is a precondition. However, the discrepancy of their results is larger than the uncertainty given for the determination of the RAKR with both methods. Results: A new approach to derive the RAKR from the measurements is investigated as an alternative. The method was developed from the ground up, based on radiation transport theory. A conversion factor C(x{sub 1}, x{sub 2}) is applied to the difference of charges measured at the two plate separations x{sub 1} and x{sub 2}. This factor is composed of quotients of three air-kerma values calculated for different plate separations in the chamber: the air kerma Ka(0) for plate separation zero, and the mean air kermas at the plate separations x{sub 1} and x{sub 2}, respectively. The RAKR determined with method (1) yields 4.877 µGy/h, and with method (2) 4.596 µGy/h. The application of the alternative approach results in 4.810 µGy/h. Conclusion: The alternative method shall be established in the future.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-656: Monte Carlo Study On Air Activation Around a Medical Electron Linac

Purpose: In high energy photon therapy, several radiation protection issues result from photonuclear reactions. The activation of air - directly by photonuclear reactions as well as indirectly by capture of photoneutrons generated inside the linac head - is a major point of concern for the medical staff. The purpose of this study was to estimate the annual effective dose to medical workers due to activated air around a medical high energy electron linac by means of Monte Carlo simulations. Methods: The treatment head of a Varian Clinac in 18 MV-X mode as well as the surrounding concrete bunker were modeled and the radiation transport was simulated using the Monte Carlo code FLUKA, starting from the primary electron striking the bremsstrahlung target. The activation yields in air from photo-disintegration of O-16 and N-14 nuclei as well as from neutron capture on Ar-40 nuclei were obtained from the simulations. The activation build-up, radioactive decay and air ventilation were studied using a mathematical model. The annual effective dose to workers was estimated by using published isotope specific conversion factors. Results: The oxygen and nitrogen activation yields were in contrast to the argon activation yield found to be field size dependent. The impact of the treatment room ventilation on the different air activation products was investigated and quantified. An estimate with very conservative assumptions gave an annual effective dose to workers of < 1 mSv/a. Conclusion: From the results of this study it can be concluded that the contribution of air activation to the radiation exposure to medical workers should be negligible in modern photon therapy, especially when it is compared to the dose due to prompt neutrons and the activation of heavy solid materials such as the jaws and the collimators inside the linac head.

60 APPLIED LIFE SCIENCES↗

Ionic composition of a humid air plasma under ionizing radiation

A kinetic model is proposed for ion–molecular processes involving charged particles of a humid air plasma produced by a fast electron beam. The model includes more than 600 processes involving electrons and 41 positive and 14 negative ions, including hydrated ions H{sub 3}O{sup +} (H{sub 2}O){sub n} and O{sub 2}{sup −}(H{sub 2}O){sub n} with n = 1, 2, …, 12. The energy costs of production of electron–ion pairs and electronic and vibrational (for water molecules, also rotational) excitation of molecules are calculated in nitrogen, oxygen, water vapor, air, and humid air. A method is proposed for calculating the energy costs in mixtures by the calculation data in pure gases. The evolution of the plasma composition is studied by the numerical solution of a system of 56 time-dependent balance equations for the number of charged particles of plasma by the fourth-order Runge–Kutta method. The steady-state composition of plasma is determined by solving nonlinear steady-state balance equations for the ionization rates of humid air from 10 to 10{sup 16} cm{sup –3}/s and the fraction of water molecules from 10{sup –3}% to 1.5%. It is established that, for water vapor content (the ratio of the number density of water molecules to the total number density of air molecules) of 0.015–1.5% in air at atmospheric pressure and room temperature, the main ion species are two types of positive ions H{sub 3}O{sup +} (H{sub 2}O){sub n} with the number of water molecules n = 5, 6 and three species of negative ions O{sub 2}{sup −}(H{sub 2}O){sub n} with n = 5, 8, 9.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

220 Rn (Thoron) Geohazard in Room Air of Earthen Dwellings in Vietnam

Thoron’s ( 220 Rn) contribution to α -radiation exposure is usually considered negligible compared to that of 222 Rn (radon). Despite its short half-life of 55.6 seconds, thoron can be exhaled from porous surface layers of building materials into indoor air where people subsequently inhale radioisotopes, including metallic radioactive progeny. Bare surfaces of dry porous soil with relatively high 232 Th content can pose a thoron radiation hazard in indoor air. On northern Vietnam’s Dong Van karst plateau, the spatial distribution of thoron was determined in indoor air of traditional earthen and other types of dwellings using portable RAD7 and SARAD® RTM 2200 detectors. “Mud houses” are constructed with local compacted soil and typically do not have any floor or wall coverings (i.e., no plaster, wallpaper, or paint). Detailed measurements in a mud house revealed levels of thoron in room air averaging >500 Bq m -3 . The spatial distribution of α -radiation from thoron in indoor air at a distance of about 1 m from interior walls was fairly homogeneous and averaged ~200 Bq m -3 . Most concerning, from a human health perspective, were the high thoron concentrations of up to 884 Bq m -3 in sleeping areas near mud walls. The average annual thoron radiation dose to inhabitants of mud houses was estimated based on 13 hours of daily occupancy, including daily activities and sleeping. The estimated average thoron inhalation dose of 27.1 mSv a -1 during sleeping hours near mud surfaces accounts for nearly 75% of the total estimated radon and thoron inhalation dose of 37.4 mSv a -1 from indoor mud house air. Our conservative annual radiation dose estimates do not include subsequent radiation from inhaled metallic progeny of thoron. Our data demonstrate a significant human health risk from radiation exposure and a critical need for remediation in traditional northern Vietnamese mud house dwellings.

58 GEOSCIENCES↗

Endurance Exercise Performance Is Reduced after 6-h Dives at 1.35 ATA When Breathing 100% Oxygen Compared with Air

ABSTRACT Introduction Long-duration dives on consecutive days reduces muscular performance, potentially affecting military personnel. However, a paucity of data exists on how breathing gases affect endurance performance. This study examined the influence of long-duration diving with different breathing gases on aerobic endurance and handgrip performance. Methods Twenty-three military divers completed a single 6-h dive (single dive [SD]) and five 6-h dives over consecutive days (dive week [DW]) with 30-min cycling intervals using air (AIR,n= 13) or 100% oxygen (OXY,n= 10). Before and after SD and DW, subjects completed a maximum handgrip strength test, a handgrip endurance test at 40% maximal strength, and a time to exhaustion run. Results Handgrip endurance decreased after DW in OXY (SD, 1.9 ± 0.0 vs 1.4 ± 0.3 min) compared with AIR (1.8 ± 0.0 vs 1.8 ± 0.2 min) (P< 0.001). Run time decreased after SD (Pre, 20.7 ± 10.4 min; Post, 16.6 ± 7.6 min;P= 0.039) and DW (Pre, 21.6 ± 9.0 min; Post, 11.2 ± 4.0 min;P< 0.001) in OXY and after overall diving in AIR (Pre, 26.5 ± 10.2 min; Post, 22.3 ± 7.5 min;P= 0.025). V̇O 2 decreased after diving only in AIR (Pre, 42.6 ± 3.4 mL·kg −1 ⋅min −1 ; Post, 40.4 ± 3.7 mL·kg −1 ⋅min −1 ;P= 0.010). There were no other significant effects. Conclusions Breathing 100% oxygen during long-duration dives on consecutive days may exacerbate decreases in aerobic endurance and impairs handgrip endurance compared with air. Additional research is needed to elucidate mechanisms of action and possible mitigation strategies.

Sport Sciences↗