Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “66”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Microwave-assisted synthesis of well-shaped UiO-66-NH2 with high CO2 adsorption capacity

Highlights: • Well-shaped UiO-66-NH{sub 2} was prepared through microwave heating in a short time. • Addition of HAc improves crystallinity and CO{sub 2} adsorption capacity of the UiO-66-NH{sub 2}. • UiO-66-NH{sub 2} prepared by microwave heating shows a higher CO{sub 2}/N{sub 2} adsorption selectivity. - Abstract: In a detailed study, the influence of microwave irradiation, synthesis time and temperature, addition of acetic acid (HAc) as a modulator on the morphology, crystallinity and stability of UiO-66-NH{sub 2} is investigated to develop a reliable and reproducible strategy for the preparation of well-shaped UiO-66-NH{sub 2}. The UiO-66-NH{sub 2} were characterized by powder X-ray diffraction (PXRD), field emission scanning electron microscopy (FESEM), thermogravimetric analysis (TGA), and gas adsorption. It is found that well-shaped UiO-66-NH{sub 2} with a high CO{sub 2} adsorption capacity can be synthesized in a short time by microwave heating. The UiO-66-NH{sub 2} crystals synthesized by microwave heating are of high quality and show a superior CO{sub 2} adsorption capacity (5.8 mmol/g at 273k and 1 bar) due to the strong interactions between the −NH{sub 2} group and CO{sub 2}. The CO{sub 2}/N{sub 2} selectivity of the obtained UiO-66-NH{sub 2} at 298 K and 1 bar is 66, which is much higher than that of the pristine UiO-66 of 17.8.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Solvothermal synthesis and characterization of highly monodisperse organically functionalized vanadium oxide nanocrystals for thermochromic applications

Highlights: • Vanadium oxide nanocrystals is synthesized via an improved solvothermal method. • Vanadium oxide nanocrystals possess a structure of distorted paramontroseite VO{sub 2}(P). • Thermally annealed nanocrystal thin films exhibit good thermochromic properties. - Abstract: We report on the synthesis and characterization of highly monodisperse organically functionalized vanadium oxide (VO{sub x}) nanocrystals with a size of 7–10 nm. We show that how these nanocrystals can be prepared by an improved solvothermal reaction and confirm their composition and structure through various materials characterization techniques. Our results revealed that VO{sub x} nanocrystals have a crystalline structure almost identical to that of paramontroseite VO{sub 2}(P) and the majority of vanadium is in oxidation state of V(IV). VO{sub x} nanocrystal films can be readily prepared via a spin coating technique. Once thermally annealed at ∼350 °C under an air/N{sub 2} flow, the films exhibited good thermochromic properties (luminous transmittance (T{sub lum}) ≈49–66%, infrared switching efficiency (ΔT{sub 2000nm}) ≈28–43%, and solar modulating ability (ΔT{sub sol}) ≈7.4–10.7%), corresponding to a phase transition between monoclinic VO{sub 2}(M) and rutile VO{sub 2}(R).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Enhanced performance and stability of electrochromic device based on poly (3-methylthiophene) using 2-thiophenecarboxylic acid as interfacial modifier

Highlights: • The PMeT film covalently bonded to ITO electrode was prepared using ThCA as modifier. • The adsorption force between the PMeT film and ITO electrode was enhanced. • The ECD based on PMeT-ITO exhibited better electrochromic stability. - Abstract: In this paper, we modified the surface of Indium tin oxide (ITO) electrode with 2-thiophenecarboxylic acid (ThCA), and then prepared the poly (3-methylthiophene) (PMeT) film covalently bonded to ITO electrode (PMeT-ITO) by electrochemical polymerization. It was found that interfacial modification enhanced the adsorption force between PMeT and ITO substrate, PMeT-ITO exhibited better stability. Moreover, we successfully fabricated the electrochromic device (ECD) by using PMeT films on ITO substrate. The results of cycling tests showed that the optical contrast of ECD based on PMeT-ITO was kept almost the same after recycling 66 times. Compared with ECD based on PMeT physically adsorbed on bare ITO substrate (PD-PMeT), the ECD based on PMeT-ITO possessed good electrochromic stability in the 150 cycles. This demonstrated that the interaction between PMeT and ITO substrate became stronger by chemical bonding approach, improving the cyclic stability of ECD.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of CrMnV and CrMnTiV multi principal element alloys thin films for use as exit windows of electron beam accelerators

Here, this study explores CrMnV and CrMnTiV multi principal element alloy (MPEA) films as candidates for electron beam exit windows in industrial, high-power accelerators. Films were deposited via magnetron sputtering on various substrates and exposed to 66 kGy of 10 MeV e-beam irradiation. Structural and mechanical properties were analyzed using FESEM, XRD, and nanoindentation. CrMnTiV films exhibited superior grain uniformity and hardness, regardless of the substrate type. Compared to bulk materials, both MPEA films demonstrated higher hardness and excellent radiation resistance. These results highlight the potential of MPEA films as durable, radiation-tolerant materials for high-performance accelerator exit window applications.

Electron Beam Irradiation↗

Correlation of dosimetric parameters obtained with the analytical anisotropic algorithm and toxicity of chest chemoradiation in lung carcinoma

The purpose of this study was to analyze and revisit toxicity related to chest chemoradiotherapy and to correlate these side effects with dosimetric parameters obtained using analytical anisotropic algorithm (AAA) in locally unresectable advanced lung cancer. We retrospectively analyzed data from 47 lung cancer patients between 2005 and 2008. All received conformal 3D radiotherapy using high-energy linear accelerator plus concomitant chemotherapy. All treatment planning data were transferred into Eclipse 8.05 (Varian Medical Systems, Palo Alto, CA) and dosimetric calculations were performed using AAA. Thirty-three patients (70.2%) developed acute pneumopathy after radiotherapy (grades 1 and 2). One patient (2.1%) presented with grade 3 pneumopathy. Thirty-one (66%) presented with grades 1-2 lung fibrosis, and 1 patient presented with grade 3 lung fibrosis. Thirty-four patients (72.3%) developed grade 1-2 acute oesophagic toxicity. Four patients (8.5%) presented with grades 3 and 4 dysphagia, necessitating prolonged parenteral nutrition. Median prescribed dose was 64 Gy (range 50-74) with conventional fractionation (2 Gy per fraction). Dose-volume constraints were respected with a median V20 of 23.5% (maximum 34%) and a median V30 of 17% (maximum 25%). The median dose delivered to healthy contralateral lung was 13.1 Gy (maximum 18.1 Gy). At univariate analysis, larger planning target volume and V20 were significantly associated with the probability of grade {>=}2 radiation-induced pneumopathy (p = 0.022 and p = 0.017, respectively). No relation between oesophagic toxicity and clinical/dosimetric parameters could be established. Using AAA, the present results confirm the predictive value of the V20 for lung toxicity as already demonstrated with the conventional pencil beam convolution approach.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric influences of rotational setup errors on head and neck carcinoma intensity-modulated radiation therapy treatments

The purpose of this work is to investigate the dosimetric influence of the residual rotational setup errors on head and neck carcinoma (HNC) intensity-modulated radiation therapy (IMRT) with routine 3 translational setup corrections and the adequacy of this routine correction. A total of 66 kV cone beam computed tomography (CBCT) image sets were acquired on the first day of treatment and weekly thereafter for 10 patients with HNC and were registered with the corresponding planning CT images, using 2 3-dimensional (3D) rigid registration methods. Method 1 determines the translational setup errors only, and method 2 determines 6-degree (6D) setup errors, i.e., both rotational and translational setup errors. The 6D setup errors determined by method 2 were simulated in the treatment planning system and were then corrected using the corresponding translational data determined by method 1. For each patient, dose distributions for 6 to 7 fractions with various setup uncertainties were generated, and a plan sum was created to determine the total dose distribution through an entire course and was compared with the original treatment plan. The average rotational setup errors were 0.7°± 1.0°, 0.1°±1.9°, and 0.3°±0.7° around left-right (LR), anterior-posterior (AP), and superior-inferior (SI) axes, respectively. With translational corrections determined by method 1 alone, the dose deviation could be large from fraction to fraction. For a certain fraction, the decrease in prescription dose coverage (V{sub p}) and the dose that covers 95% of target volume (D{sub 95}) could be up to 15.8% and 13.2% for planning target volume (PTV), and the decrease in V{sub p} and the dose that covers 98% of target volume (D{sub 98}) could be up to 9.8% and 5.5% for the clinical target volume (CTV). However, for the entire treatment course, for PTV, the plan sum showed that the average V{sub p} was decreased by 4.2% and D{sub 95} was decreased by 1.2 Gy for the first phase of IMRT with a prescription dose of 50 Gy. For CTV, the plan sum showed that the average V{sub p} was decreased by 0.8% and D{sub 98}, relative to prescription dose, was not decreased. Among these 10 patients, the plan sum showed that the dose to 1-cm{sup 3} spinal cord (D{sub 1cm{sup 3}}) increased no more than 1 Gy for 7 patients and more than 2 Gy for 2 patients. The average increase in D{sub 1cm{sup 3}} was 1.2 Gy. The study shows that, with translational setup error correction, the overall CTV V{sub p} has a minor decrease with a 5-mm margin from CTV to PTV. For the spinal cord, a noticeable dose increase was observed for some patients. So to decide whether the routine clinical translational setup error correction is adequate for this HNC IMRT technique, the dosimetric influence of rotational setup errors should be evaluated carefully from case to case when organs at risk are in close proximity to the target.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spine stereotactic body radiation therapy plans: Achieving dose coverage, conformity, and dose falloff

We report our experience of establishing planning objectives to achieve dose coverage, conformity, and dose falloff for spine stereotactic body radiation therapy (SBRT) plans. Patients with spine lesions were treated using SBRT in our institution since September 2009. Since September 2011, we established the following planning objectives for our SBRT spine plans in addition to the cord dose constraints: (1) dose coverage—prescription dose (PD) to cover at least 95% planning target volume (PTV) and 90% PD to cover at least 99% PTV; (2) conformity index (CI)—ratio of prescription isodose volume (PIV) to the PTV < 1.2; (3) dose falloff—ratio of 50% PIV to the PTV (R{sub 50%}); (4) and maximum dose in percentage of PD at 2 cm from PTV in any direction (D{sub 2cm}) to follow Radiation Therapy Oncology Group (RTOG) 0915. We have retrospectively reviewed 66 separate spine lesions treated between September 2009 and December 2012 (31 treated before September 2011 [group 1] and 35 treated after [group 2]). The χ{sup 2} test was used to examine the difference in parameters between groups. The PTV V{sub 100%} {sub PD} ≥ 95% objective was met in 29.0% of group 1 vs 91.4% of group 2 (p < 0.01) plans. The PTV V{sub 90%} {sub PD} ≥ 99% objective was met in 38.7% of group 1 vs 88.6% of group 2 (p < 0.01) plans. Overall, 4 plans in group 1 had CI > 1.2 vs none in group 2 (p = 0.04). For D{sub 2cm}, 48.3% plans yielded a minor violation of the objectives and 16.1% a major violation for group 1, whereas 17.1% exhibited a minor violation and 2.9% a major violation for group 2 (p < 0.01). Spine SBRT plans can be improved on dose coverage, conformity, and dose falloff employing a combination of RTOG spine and lung SBRT protocol planning objectives.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation dermatitis caused by a bolus effect from an abdominal compression device

American Association of Physicists in Medicine (AAPM) Task Group 176 evaluated the dosimetric effects caused by couch tops and immobilization devices. The report analyzed the extensive physics-based literature on couch tops, stereotactic body radiation therapy (SBRT) frames, and body immobilization bags, while noting the scarcity of clinical reports of skin toxicity because of external devices. Here, we present a clinical case report of grade 1 abdominal skin toxicity owing to an abdominal compression device. We discuss the dosimetric implications of the utilized treatment plan as well as post hoc alternative plans and quantify differences in attenuation and skin dose/build-up between the device, a lower-density alternative device, and an open field. The description of the case includes a 66-year-old male with HER2 amplified poorly differentiated distal esophageal adenocarcinoma treated with neoadjuvant chemo-radiation and the use of an abdominal compression device. Radiation was delivered using volumetric modulated arc therapy (VMAT) with 2 arcs using abdominal compression and image guidance. The total dose was 50.4 Gy delivered over 40 elapsed days. With 2 fractions remaining, the patient developed dermatitis in the area of the compression device. The original treatment plan did not include a contour of the device. Alternative post hoc treatment plans were generated, one to contour the device and a second with anterior avoidance. In conclusion, replanning with the device contoured revealed the bolus effect. The skin dose increased from 27 to 36 Gy. planned target volume (PTV) coverage at 45 Gy was reduced to 76.5% from 95.8%. The second VMAT treatment plan with an anterior avoidance sector and more oblique beam angles maintained PTV coverage and spared the anterior wall, however at the expense of substantially increased dose to lung. This case report provides an important reminder of the bolus effect from external devices such as abdominal compression. Special consideration must be given to contour and/or avoiding beam entrance to the device, and to the use of such devices in patients who may have heightened radiosensitivity, such as those who are human immunodeficiency virus (HIV)–positive.

61 RADIATION PROTECTION AND DOSIMETRY↗

Heart-sparing radiotherapy in patients with breast cancer: What are the techniques used in the clinical routine?

The aim of this study was to understand the practice of care in German-speaking countries with regard to heart-sparing radiotherapy techniques. Between August 2015 and September 2015, an e-mail/fax-based survey was sent to radiation oncology departments in Germany, Austria, and the German-speaking Switzerland. The questionnaire was divided into 3 chapters: a general chapter on the department, a chapter specific for heart-sparing techniques in patients with breast cancer, and a third chapter on personal beliefs on the topic of heart sparing in patients with breast cancer. A total of 82 radiation oncology departments answered the questionnaire: 16 university clinics and 66 other departments. In general, heart-sparing techniques are being offered by 90.2% of departments for radiation oncology in the German-speaking countries. However, in the clinical routine, 87.7% of institutions use heart-sparing techniques in less than 50% of patients with breast cancer. Heart-sparing techniques are especially provided for patients with left-sided breast cancer (80%), patients after mastectomy (52.5%), and when the mammaria interna lymph drainage vessels are irradiated (41.3%). In 46.3% of departments, there are written internal guidelines for heart sparing in patients with breast cancer. Breathing-adapted radiotherapy is used as the most frequent heart-sparing technique in 64.7% of the institutions, followed by intensity-modulated radiation therapy, which is most frequently used by 22.1%. The only significant difference between university hospitals and other departments was seen for the offering of partial breast irradiation. The most commonly used heart-sparing technique is breathing-adapted radiotherapy, but there is no coherent approach for heart sparing in patients with breast cancer in the German-speaking countries. Overall, all options for cardiac protection/cardiac avoidance have their advantages and disadvantages, with deep inspiration breath-hold radiotherapyhaving the most clear data, which should be the preferred choice when using heart-sparing techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Immobilization and image-guidance methods for radiation therapy of limb extremity soft tissue sarcomas: Results of a multi-institutional survey

Radiation therapy for limb-extremity soft tissue sarcoma (STS) requires accurate, reproducible dose delivery. However, patient positioning is challenging and there is a lack of existing guidelines to assist institutional standardization. Therefore, we conducted a multi-institutional international survey of STS immobilization, image guidance methods, and treatment protocols to investigate current practice. Seventy-three UK radiotherapy centers and 15 hospitals in 7 other countries completed a questionnaire on STS immobilization and image-guidance procedures. Specifically, the survey collated information on the current usage of immobilization equipment, including custom devices, patient setup tolerances, the use of written protocols, the modality and frequency of image guidance, the method of treatment, allocated treatment times, and the application of surgical clips. Multiple combinations of immobilization devices were reported. In the UK, 12%, 40%, 30%, 12%, and 5% use 1, 2, 3, 4, and 5 types of device for lower limb STS. Vacuum bag plus either foot or ankle support was most common (66%). Of 15 international centers, 27%, 60%, 7%, 0%, 7% use 1, 2, 3, 4, 5 devices, with vacuum bags (73%) and thermoplastic (47%) predominant, similar to UK values of 77% and 52%. For image guidance, in the UK, 37% use kV planar, 34% use MV planar, and 16% use cone-beam CT for the first 3 fractions and then weekly. Internationally, daily imaging was more prevalent with 33% using kV planar, 7% MV planar, and 40% cone-beam CT daily. Custom devices plus combinations of devices, along with 5- and 10-mm set-up tolerances, were most commonly reported. Less than half of centers have written treatment protocols. Conventional treatment is most common in the UK, with only 42% using conformal techniques. Treatment is allocated between 10 and 30 minutes. Twenty-six percent of UK centers and 53% of international centers use surgical clips. Across treatment centers, there is no consistent approach to STS immobilization, image-guidance methods, or treatment protocols assessed by this survey. A wide variety of immobilization devices and configurations are utilized, and the frequency and modality of imaging are similarly diverse. In the absence of guidelines, the creation of an online repository of example immobilization techniques could enable centers to compare a diversity of cases. The availability of a forum for viewing and discussing a range of cases could potentially lead to improved patient setup and reduce the time taken to devise an individual immobilization strategy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thin Porous Metal Sheet-Supported NaA Zeolite Membrane for Water/Ethanol Separation

This paper reports preparation and separation testing results of water-selective zeolite membrane, such as NaA (or 4A-type), supported on a robust, porous metal sheet of 50um thickness. The thin sheet support is of large potential for development of a low-cost, inorganic membrane module of high surface area packing density. The porous Ni alloy sheet of micrometer or sub-micrometer mean pore size, which was prepared by a proprietary process, is used to evaluate different zeolite membrane deposition methods and conditions. The membranes are characterized by SEM, XRD and water/ethanol separation tests. Quality NaA zeolite membrane at thickness <2um is obtained with the secondary hydrothermal growth method. This membrane shows water/ethanol separation factor of >10,000 and water permeation flux of about 4 kg/(m2•h) at 75ºC with a feed of 10wt% water in ethanol. The membrane is also demonstrated with good stability in 66-hour continuous testing at 75ºC and 90ºC.

36 MATERIALS SCIENCE↗

Evaluation of a nanoporous lyotropic liquid crystal polymer membrane for the treatment of hydraulic fracturing produced water via cross-flow filtration

Current commercial nanofiltration and reverse osmosis membranes are limited in scope and performance due to their physicochemical properties. Desalination of hydraulic fracturing wastewater poses a particular challenge to membrane filtration given the high concentrations of both organic compounds and salts present in these waters. The recently-developed nanoporous, bicontinuous cubic, lyotropic liquid crystal, thin-film-composite polymer membrane (TFC Q I membrane), having unique physicochemical properties, enables an alternative treatment of hydraulic fracturing wastewater. Specifically, the TFC Q I membrane recovers the organic compounds from this high-salinity wastewater, enabling biodegradation to occur after desalination. However, other performance criteria must be demonstrated for a membrane to reach application. The work presented herein demonstrates the stable performance of the TFC Q I membrane during 66 h of cross-flow filtration of hydraulic fracturing produced water. Compared to the commercial NF90 membrane, the TFC Q I membrane recovered a larger portion of the organic compounds, had a higher thickness-normalized water flux, and fouled less. Finally, the combination of the TFC Q I membrane's selectivity with its reduced fouling propensity makes possible a treatment for hydraulic fracturing wastewater and other complex aqueous streams inaccessible by most commercial membranes, motivating the further study and development of the TFC Q I membrane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deformation mode and strain path dependence of martensite phase transformation in a medium manganese TRIP steel

The martensite phase transformation dependence upon deformation modes and strain paths in a medium manganese (10 wt%) TRIP steel stamped into a T-shape panel was quantified through combination of 3D digital image correlation and synchrotron X-ray diffraction. The T-shape emulates a portion of a common anti-intrusion component. The stamping speed was kept intentionally slow (1 mm/s) so as to avoid excessive heat generation. The steel, which belongs to the third generation advanced high strength steel (3GAHSS) family, was chosen for two reasons: (1) it is two-phase, i.e. austenite and ferrite, with martensite resulting from deformation-induced phase transformation; (2) the 66 vol.% initial retained austenite volume fraction (RAVF) enabled a thorough examination of the martensite phase transformation at large deformation levels without exhaustion. Strain fields were coupled with measured RAVF values of small specimens extracted from specific locations on a formed T-shape panel. This enabled an exploration of the effects of linear, bilinear, and non-linear strain paths as well as deformation modes such as tension, plane strain, biaxial tension, and equibiaxial tension. Results suggest a significant martensite phase transformation dependence on deformation mode and strain path in the absence of fracture and when martensite phase transformation is unaffected by heat generated during forming. In general, the uniaxial and biaxial tension deformation modes facilitate the martensite phase transformation, while the smallest amount of martensite phase transformation occurs under plane strain. In conclusion, some discussion as to further application of the experimental methods detailed in this study to other 3GAHSS and the effects of fracture on martensite phase transformation is provided.

36 MATERIALS SCIENCE↗

Metacognition, cortical thickness, and tauopathy in aging

We investigated self-rating of cognitive task performance (self-appraisal) and the difference between self-rating and actual task performance (appraisal discrepancy) in cognitively healthy older adults and their relationship with cortical thickness and Alzheimer's disease (AD) biomarkers, amyloid and tau. All participants (N = 151) underwent neuropsychological testing and 1.5T structural magnetic resonance imaging. A subset (N = 66) received amyloid-PET with [11C] PiB and tau-PET with [18F] Flortaucipir. We found that worse performers had lower self-appraisal ratings, but still overestimated their performance, consistent with the Dunning-Kruger effect. Self-appraisal rating and appraisal discrepancy revealed distinct relationships with cortical thickness and AD pathology. Greater appraisal discrepancy, indicating overestimation, was related to thinning of inferior-lateral temporal, fusiform, and rostral anterior cingulate cortices. Lower self-appraisal was associated with higher entorhinal and inferior temporal tau. These results suggest that overestimation could implicate structural atrophy beyond AD pathology, while lower self-appraisal could indicate early behavioral alteration due to AD pathology, supporting the notion of subjective cognitive decline prior to objective deficits.

59 BASIC BIOLOGICAL SCIENCES↗

Optimizing quantification of MK6240 tau PET in unimpaired older adults

Accurate measurement of Alzheimer's disease (AD) pathology in older adults without significant clinical impairment is critical to assessing intervention strategies aimed at slowing AD-related cognitive decline. The U.S. Study to Protect Brain Health Through Lifestyle Intervention to Reduce Risk (POINTER) is a 2-year randomized controlled trial to evaluate the effect of multicomponent risk reduction strategies in older adults (60-79 years) who are cognitively unimpaired but at increased risk for cognitive decline/dementia due to factors such as cardiovascular disease and family history. The POINTER Imaging ancillary study is collecting tau-PET ([ 18 F]MK6240), beta-amyloid (Aβ)-PET ([ 18 F]florbetaben [FBB]) and MRI data to evaluate neuroimaging biomarkers of AD and cerebrovascular pathophysiology in this at-risk sample. Here 481 participants (70.0±5.0; 66% F) with baseline MK6240, FBB and structural MRI scans were included. PET scans were coregistered to the structural MRI which was used to create FreeSurfer-defined reference regions and target regions of interest (ROIs). We also created off-target signal (OTS) ROIs to examine the magnitude and distribution of MK6240 OTS across the brain as well as relationships between OTS and age, sex, and race. OTS was unimodally distributed, highly correlated across OTS ROIs and related to younger age and sex but not race. Aiming to identify an optimal processing approach for MK6240 that would reduce the influence of OTS, we compared our previously validated MRI-guided standard PET processing and 6 alternative approaches. The alternate approaches included combinations of reference region erosion and meningeal OTS masking before spatial smoothing as well as partial volume correction. To compare processing approaches we examined relationships between target ROIs (entorhinal cortex (ERC), hippocampus or a temporal meta-ROI (MetaROI)) SUVR and age, sex, race, Aβ and a general cognitive status measure, the Modified Telephone Interview for Cognitive Status (TICSm). Overall, the processing approaches performed similarly, and none showed a meaningful improvement over standard processing. Across processing approaches we observed previously reported relationships with MK6240 target ROIs including positive associations with age, an Aβ+> Aβ- effect and negative associations with cognition. In sum, we demonstrated that different methods for minimizing effects of OTS, which is highly correlated across the brain within subject, produced no substantive change in our performance metrics. This is likely because OTS contaminates both reference and target regions and this contamination largely cancels out in SUVR data. Caution should be used when efforts to reduce OTS focus on target or reference regions in isolation as this may exacerbate OTS contamination in SUVR data.

60 APPLIED LIFE SCIENCES↗

Design and test of the Mu2e undoped CsI+SiPM crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavour violating neutrino-less conversion of a negative muoninto an electron in the field of an aluminum nucleus. The calorimeter plays an important role in providing a fast trigger filter,excellent particle identification and a seeding for track reconstruction. Its requirements are to provide an energy (timing) resolutionbetter than 10% (0.5 ns) and a position resolution below 1 cm, for 100 MeV electrons. The calorimeter consists of two disks, eachone made of 674 un-doped CsI crystals readout by two large area arrays of 23 UV-extended SiPMs of 66 mm2dimensions.A large scale prototype (Module-0) has been constructed and tested with an electron beam in the energy range between 60 and 120MeV at the BTF of Frascati National Laboratories. Results demonstrated that this calorimeter satisfies the Mu2e requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗