Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D Visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Radar and Lidar Radar DEM

Using radar and lidar data, the aim is to improve 3D rendering of terrain, including digital elevation models (DEM) and estimates of vegetation height and biomass in a variety of forest types and terrains. The 3D mapping of vegetation structure and the analysis are useful to determine the role of forest in climate change (carbon cycle), in providing habitat and as a provider of socio-economic services. This in turn will lead to potential for development of more effective land-use management. The first part of the project was to characterize the Shuttle Radar Topography Mission DEM error with respect to ICESat/GLAS point estimates of elevation. We investigated potential trends with latitude, canopy height, signal to noise ratio (SNR), number of LiDAR waveform peaks, and maximum peak width. Scatter plots were produced for each variable and were fitted with 1st and 2nd degree polynomials. Higher order trends were visually inspected through filtering with a mean and median filter. We also assessed trends in the DEM error variance. Finally, a map showing how DEM error was geographically distributed globally was created.

remote sensing↗

PDB‐101: Molecular Explorations through Biology and Medicine

PDB‐101 is an online portal for teachers, students, and the general public to promote exploration of the structural biology of proteins and nucleic acids ( pdb101.rcsb.org ). Learning about the diverse shapes and functions of these biological macromolecules helps to understand all aspects of biomedicine and agriculture, from protein synthesis to health and disease to biological energy. Why PDB‐101? Researchers around the world are studying these molecules at the atomic level. These 3D structures are freely available at the Protein Data Bank (PDB), the central storehouse of biomolecular structures. This website builds introductory materials to help beginners get started in the basics of biomolecular structure and function (“101”, as in an entry level course) as well as resources for extended learning. Since 2011, PDB‐101 has been developed by the RCSB PDB , a global resource for the advancement of research and education in biology and medicine. Along with our Worldwide PDB collaborators, RCSB PDB curates, annotates, and makes publicly available the PDB data deposited by scientists around the globe. The RCSB PDB then provides a window to these data through a rich online resource with powerful searching, reporting, and visualization tools for researchers. This information is then streamlined for students and teachers at PDB‐101. Features include the ongoing Molecule of the Month series, educational materials such as paper models, posters, molecular animations, educational curricula and more. The section “Guide to Understanding PDB Data” is a primer for detailed PDB‐specific information: PDB Data, Visualizing Structures, Reading Coordinate Files, scientific methods for structure determination, and more. PDB‐101 also runs annual Video Challenges for high school students. Participants create short videos that tell molecular stories that connect structural biology and medicine. Previous topics have included HIV/AIDS, diabetes, and antimicrobial resistance. The 2022 challenge will focus on Molecular Mechanisms of Cancer. PDB‐101 activities are evaluated using user surveys, feedback from in‐person activities, and website analytics. In 2020, PDB‐101 hosted >850,000 users and >2.6 million page views.

Zardecki, Christine↗

SU-C-17A-05: Quantification of Intra-Fraction Motion of Breast Tumors Using Cine-MRI

Purpose: Magnetic resonance imaging (MRI) enables direct characterization of intra-fraction motion ofbreast tumors, due to high softtissue contrast and geometric accuracy. The purpose is to analyzethis motion in early-stage breast-cancer patients using pre-operative supine cine-MRI. Methods: MRI was performed in 12 female early-stage breast-cancer patients on a 1.5-T Ingenia (Philips)wide-bore scanner in supine radiotherapy (RT) position, prior to breast-conserving surgery. Twotwodimensional (2D) T2-weighted balanced fast-field echo (cine-MRI) sequences were added tothe RT protocol, oriented through the tumor. They were alternately acquired in the transverse andsagittal planes, every 0.3 s during 1 min. A radiation oncologist delineated gross target volumes(GTVs) on 3D contrast-enhanced MRI. Clinical target volumes (CTV = GTV + 15 mm isotropic)were generated and transferred onto the fifth time-slice of the time-series, to which subsequents lices were registered using a non-rigid Bspline algorithm; delineations were transformed accordingly. To evaluate intra-fraction CTV motion, deformation fields between the transformed delineations were derived to acquire the distance ensuring 95% surface coverage during scanning(P95%), for all in-plane directions: anteriorposterior (AP), left-right (LR), and caudal-cranial(CC). Information on LR was derived from transverse scans, CC from sagittal scans, AP fromboth sets. Results: Time-series with registration errors - induced by motion artifacts - were excluded by visual inspection. For our analysis, 11 transverse, and 8 sagittal time-series were taken into account. Themedian P95% calculated in AP (19 series), CC (8), and LR (11) was 1.8 mm (range: 0.9–4.8), 1.7mm (0.8–3.6), and 1.0 mm (0.6–3.5), respectively. Conclusion: Intra-fraction motion analysis of breast tumors was achieved using cine-MRI. These first results show that in supine RT position, motion amplitudes are limited. This information can be used for adaptive RT planning, and to develop preoperative partial-breast RT strategies, such asablative RT for early-stage breast-cancer patients.

60 APPLIED LIFE SCIENCES↗

TU-A-17A-02: In Memoriam of Ben Galkin: Virtual Tools for Validation of X-Ray Breast Imaging Systems

This symposium will explore simulation methods for the preclinical evaluation of novel 3D and 4D x-ray breast imaging systems – the subject of AAPM taskgroup TG234. Given the complex design of modern imaging systems, simulations offer significant advantages over long and costly clinical studies in terms of reproducibility, reduced radiation exposures, a known reference standard, and the capability for studying patient and disease subpopulations through appropriate choice of simulation parameters. Our focus will be on testing the realism of software anthropomorphic phantoms and virtual clinical trials tools developed for the optimization and validation of breast imaging systems. The symposium will review the stateof- the-science, as well as the advantages and limitations of various approaches to testing realism of phantoms and simulated breast images. Approaches based upon the visual assessment of synthetic breast images by expert observers will be contrasted with approaches based upon comparing statistical properties between synthetic and clinical images. The role of observer models in the assessment of realism will be considered. Finally, an industry perspective will be presented, summarizing the role and importance of virtual tools and simulation methods in product development. The challenges and conditions that must be satisfied in order for computational modeling and simulation to play a significantly increased role in the design and evaluation of novel breast imaging systems will be addressed. Learning Objectives: Review the state-of-the science in testing realism of software anthropomorphic phantoms and virtual clinical trials tools; Compare approaches based upon the visual assessment by expert observers vs. the analysis of statistical properties of synthetic images; Discuss the role of observer models in the assessment of realism; Summarize the industry perspective to virtual methods for breast imaging.

60 APPLIED LIFE SCIENCES↗

SU-E-I-41: Non-Cartesian MR Image Reconstruction with Integrated Gradient Non-Linearity Correction

Purpose: Nonlinearities in the spatial encoding gradients of MRI systems cause geometric distortion in images. Typically, this is retrospectively corrected via image-domain interpolation (a.k.a., “gradwarp”) albeit with a loss of spatial resolution. For non-Cartesian MRI, the latter problem is exaggerated by noise and undersampling artifact. In this study, we describe a novel correction strategy that accounts for gradient nonlinearities during — rather than after — non-Cartesian MRI reconstruction, and demonstrate that this approach mitigates the resolution loss that can occur with standard methods. Methods: To test the proposed method, the American College of Radiology (ACR) quality control phantom was scanned on at 1.5 T (General Electric, v16.0, “zoom” gradient) using a 1.6x undersampled 3D non- Cartesian Shells trajectory (GRE, FOV=24 cm3, 120 shells, 16552 shots, 512 readout, matrix=2403). Image reconstruction was first performed via standard k-space density-compensated gridding and retrospectively corrected via cubic spline interpolation. Image reconstruction was then separately performed using a k-space and image-domain densitycompensated type-3 non-uniform fast Fourier transform (NUFFT), which provides a direct mapping between non-Cartesian k-space samples and warped image space voxel locations. Thus, no separate distortion correction procedure is needed for the proposed approach. The gradient distortion field was determined using vendor provided calibration data. Results: Phantom scan results show that both processing approaches successfully correct geometric distortion. However, visual inspection of the ACR phantom spatial resolution inserts shows that the proposed strategy preserves the resolution of the nominal (uncorrected) reconstruction while “gradwarp” imparts marked spatial blurring (especially for the 1.0 and 1.1 mm inserts) and thus resolution loss. Conclusion: We've presented a novel reconstruction strategy for non-Cartesian MRI that corrects for gradient nonlinearities during — rather than after — reconstruction, and thus better preserves image resolution than traditional interpolation-based methods. This approach is expected to be especially advantageous when imaging with non-standard magnet geometries. NIH RR018898; NIH EB10065.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-Dimensional Analysis and Modeling of a Wankel Engine

A new computer code, AGNI-3D, has been developed for the modeling of combustion, spray, and flow properties in a stratified-charge rotary engine (SCRE). The mathematical and numerical details of the new code are described by the first author in a separate NASA publication. The solution procedure is based on an Eulerian-Lagrangian approach where the unsteady, three-dimensional Navier-Stokes equations for a perfect gas-mixture with variable properties are solved in generalized, Eulerian coordinates on a moving grid by making use of an implicit finite-volume, Steger-Warming flux vector splitting scheme. The liquid-phase equations are solved in Lagrangian coordinates. The engine configuration studied was similar to existing rotary engine flow-visualization and hot-firing test rigs. The results of limited test cases indicate a good degree of qualitative agreement between the predicted and measured pressures. It is conjectured that the impulsive nature of the torque generated by the observed pressure nonuniformity may be one of the mechanisms responsible for the excessive wear of the timing gears observed during the early stages of the rotary combustion engine (RCE) development. It was identified that the turbulence intensities near top-dead-center were dominated by the compression process and only slightly influenced by the intake and exhaust processes. Slow mixing resulting from small turbulence intensities within the rotor pocket and also from a lack of formation of any significant recirculation regions within the rotor pocket were identified as the major factors leading to incomplete combustion. Detailed flowfield results during exhaust and intake, fuel injection, fuel vaporization, combustion, mixing and expansion processes are also presented. The numerical procedure is very efficient as it takes 7 to 10 CPU hours on a CRAY Y-MP for one entire engine cycle when the computations are performed over a 31 x16 x 20 grid.

Raju, M. S.↗

Virtual Flight through a Catalyst Particle

This visualization of the experimental data shows how scientists mapped the distribution of chemical elements in a single fluid catalytic cracking (FCC) particle and merged it with structural information about the pore networks. Because of the high resolution at which they mapped the catalyst, they were able to look deep into the pores and learn more about the metal poisoning reaction. The changing colors of the "fog" inside the pores reflect the changing chemistry.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Intelligent Process Visualization through Nuclear Operation Process Modeling, Reasoning, and Object Detection from Field Videos (Final Report)

This report is a deliverable for the “Final Report” task of DOE NEET Project 19-16790, "Context-Aware Safety Information Display for Nuclear Field Workers." This project's overall goal is to test the hypothesis that integrating computer vision and process reasoning methods will enable proactive visualization of the safe operation and maintenance processes of Nuclear Power Plants (NPP) for field workers. Augmented Reality (AR) glasses adopting such proactive safety information visualization techniques can significantly increase personnel safety and reduce the NPP’s operating costs. The current practice of monitoring NPPs requires workers to switch between digital models, data, and physical workspaces in identifying relevant but potentially occluded objects and in assessing the risks of operation and maintenance processes. On the other hand, frequently changed field conditions require field workers to report to supervisors for real-time guidance. Such guidance is essential to ensure that changing conditions will not invalidate or endanger the work order and other ongoing processes that may jeopardize NPP operations. Additionally, incorrect recognition of equipment objects can result in communication errors and safety problems. AR techniques can assist engineers in viewing the physical workspaces with objects labeled with detailed operation procedures and safety reminders during field operations. The project team developed an “Intelligent Context-Aware Safety Information Display” (ICAD) for supporting Nuclear Power Plant (NPP) field workers in achieving safe and efficient execution of a series of operational tasks in uncertain and changing workspaces of an NPP. Before designing the ICAD-AR prototype, the project team synthesized NPP operational knowledge models through literature review studies, surveys, interviews with domain experts, and knowledge modeling. The project team conducted an extensive study of the operational procedures of various NPPs, and digital technologies that can support the safe and efficient execution of those procedures in different NPP operational contexts. This literature review helped the project team conduct surveys and interviews with nuclear engineers and field workers to identify three categories of information. The NPP knowledge modeling efforts reveal that the three categories of information identified have different levels of importance in a typical procedure of carrying out a series of tasks to achieve a specific NPP operation goal (e.g., shutdown, mode changes). These three categories of information include 1) Workspace dynamics – the changing spatial arrangements of workspaces, tools, protection equipment, and supporting materials, 2) Workflow prognostics – the dynamic dependencies between different parts of an NPP that functionally support and influence each other in terms of safety and efficiency, and 3) Hazards – objects and spaces that contain hazardous materials or physical conditions that can pose risks to workers or mechanical systems. The project team has profiled the importance levels of these categories of information into a knowledge model. This knowledge model specifies what types of information are more critical for a given task in a given workspace so that computers can automatically identify critical objects and sensors in a scene for delivering context-ware safety information to field workers through AR devices. Significant research development of this project results in technical research outcomes and a prototyping system that illustrates the technical feasibility of establishing an ICAD-AR system supporting the proactive safety information display for nuclear field workers. This final report summarizes the project team’s technological achievements in the past three years. Overall, the project team completed the development and integration of five techniques into a prototype ICAD Augmented Reality (ICAD-AR) system and demonstrated the developed system’s real-time execution in a mechanical room. The project team completed the analysis of using this prototype in other types of workspaces based on 3D image data and digital design models collected from two additional workspaces (a water treatment plant and a flow loop training facility). The integrated techniques include 1) Natural Language Processing (NLP) algorithms supporting the generation and updates of nuclear fieldwork process models based on text analysis of work packages and operation manuals; 2) sensor log analysis for predicting control actions in given sensor reading contexts; 3) computer vision algorithms for automatic localization and navigation of workers; 4) object detection algorithms for identifying task-related objects and correlated sensors for safety checking; 5) AR technique as a platform for supporting the integration. The testing results of these five techniques have shown that 1) the sensor log analysis model can predict the next control action with an accuracy of 0.883; 2) the trained natural language processing model can extract more than 80% of the critical information from paper-based procedures (PBPs); 3) the navigation algorithm with the integration of Visual Inertial Odometry (VIO) and Non-Recursive Bayesian Filter methods make operator’s trajectory estimation resilient to drift error; 4) the computer vision algorithm can detect task-specific and safety-critical objects with an average accuracy of 95.3%. The project team used work procedures collected from a flow loop training facility and two datasets collected from two mechanical rooms simulating the workspaces of NPPs to demonstrate the technical capabilities of the developed ICAD-AR prototype. The demonstration validated the technical feasibility of establishing the ICAD-AR system for nuclear field workers and identified the challenges in 1) automatic text analysis of work packages; 2) use of limited samples of sensor logs for predicting the proper timings of control actions; 3) reliably tracking workers and their task progress in mechanical rooms with many similar objects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-J-203: Reconstruction of the Treatment Area by Use of Sinogram in Helical Tomotherapy

Purpose: TomoTherapy (Accuray Co.) has an image-guided radiotherapy system with megavoltage (MV) X-ray source and the on-board imaging device. With the MV computed tomography (MVCT), it became feasible to perform the efficient daily-3D registration of the patient position before each treatment delivery. This system also allows one to acquire the delivery sinogram during the actual treatment, which partly includes the information of the irradiated object. In this study, we try to develop the image reconstruction during treatment in helical Tomotherapy. Methods: Sinogram data were acquired during helical Tomotherapy delivery using an arc-shaped detector array that consists of 738 xenon-gas filled detector cells. In preprocessing, these were normalized by full air-scan data. A software program was developed that reconstructs 3D images during treatment with corrections as; (1) the regions outside the field were masked not to be added in the backprojection (a masking correction), and (2) each voxel of the reconstructed image was divided by the number of the X-ray passing through its voxel (a ray-passing correction). Results: Without masking and ray-passing corrections, the image reconstruction was failed. The masking correction made the image clear, however, the streak artifact was accompanied. The ray-passing correction reduced this artifact. Although the SNR (the ratio of mean to standard deviation in homogeneous region) and the contrast of the reconstructed image were slightly improved with the ray-passing correction, the masking correction only is enough for the visualization purpose. Conclusion: The visualization of the treatment area was feasible by use of the sinogram in helical Tomotherapy. This proposed method can be utilized in the treatment verification. This work was partly supported by JSPS KAKENHI 24234567. No COI, but the data in this paper were prepared by collaborators in Accuray.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PROTEUS-MOC User Manual

The PROTEUS-MOC code is a three-dimensional (3D) neutron transport code based on the finite element mesh and the method of characteristics (MOC) which combines a 2D MOC with the discontinuous Galerkin finite element method for the axial direction. Thus, for PROTEUS-MOC, a 3D geometry is represented with by the implicit extrusion of a single 2D planar geometry with different material assignments allowable on each plane. The code requires four input files for a steady-state calculation without the thermal feedback: a driver input, a mesh input, a cross section input, and a material assignment input. With thermal feedback, a T/H input file is needed. For kinetics, a kinetics driver input file is required. The PROTEUS-MOC software produces a text output file as well as a data file which includes integral and average quantities such on fluxes, powers, temperatures, densities, etc. The detailed output file can be converted to the VTK format using the post processing code so that the outputs can be visualized using a visualization software such as VisIt.

97 MATHEMATICS AND COMPUTING↗

Influence of Contrast Agent Dilution on Ballon Deflation Time and Visibility During Tracheal Balloon Dilation: A 3D Printed Phantom Study

PurposeTo determine the effect of contrast medium dilution during tracheal balloon dilation on balloon deflation time and visibility using a 3-dimensional (3D) printed airway phantom.Materials and MethodsA comparison study to investigate balloon deflation times and image quality was performed using two contrast agents with different viscosities, i.e., iohexol and ioxithalamate, and six contrast dilutions with a 3D printed airway phantom.ResultsCompared to 1:0 concentration, 3:1, 2:1, 1:1, 1:2, and 1:3, contrast/saline ratios resulted in a 46% (56.2 s), 59.8% (73.1 s), 74.9% (91.6 s), 81.7% (99.8 s), and 83.5% (102 s) reduction for iohexol, respectively, and a 51.8% (54.7 s), 63.8% (67.6 s), 74.7% (79.2 s), 80.5% (85.3 s), and 82.4% (87.4 s) reduction for ioxithalamate, respectively, in the mean balloon deflation time, although at the expense of decreased balloon opacity (3.5, 6.9, 11.1, 12.4, and 13.9%, for iohexol, respectively, and 3.2, 6, 9.6, 10.8, and 12.4%, for ioxithalamate, respectively).ConclusionsUse of a lower viscosity contrast agent and higher contrast dilution is considered to be able to reduce balloon deflation times and then simultaneously decrease visualization of balloons. The rapid balloon deflation time is likely to improve the safe performance of interventional procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FLARE: field line analysis and reconstruction for 3D boundary plasma modeling

The FLARE code is a magnetic mesh generator that is integrated within a suite of tools for the analysis of the magnetic geometry in toroidal fusion devices. A magnetic mesh is constructed from field line segments and permits fast reconstruction of field lines in 3D boundary plasma codes such as EMC3-EIRENE. Both intrinsically non-axisymmetric configurations (stellarators) and those with symmetry breaking perturbations of an axisymmetric equilibrium (tokamaks) are supported. The code itself is written in Modern Fortran with MPI support for parallel computing, and it incorporates object-oriented programming for the definition of the magnetic field and the material surface geometry. Extended derived types for a number of different magnetohydrodynamic equilibrium and plasma response models are implemented. The core element of FLARE is a field line tracer with adaptive step-size control, and this is integrated into tools for the construction of Poincaré maps and invariant manifolds of X-points. A collection of high-level procedures that generate output files for visualization is build on top of that. The analysis modules are build with Python frontends that facilitate customization of tasks and/or scripting of parameter scans.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power-law descriptions of the phantom images were in general agreement with real human images. The Singlet approach offered more realistic contrast as compared to the Doublet approach, but at the expense of air bubbles and air pockets that formed during the filling process. Conclusions: The presented physical breast phantoms and their matching virtual breast phantoms offer realistic breast anatomy, patient variability, and ease of use, making them a potential candidate for performing both system quality control testing and virtual clinical trials.

60 APPLIED LIFE SCIENCES↗

Analysis of Inter-Moss Loops in the Solar Region with IRIS and SDO AIA: Automatic Event Detection and Characterization

The Interface Region Imaging Spectrograph (IRIS), launched in the summer of 2013, is designed specifically to observe and investigate the transition region and adjacent layers of the solar atmosphere, obtaining images in high spatial, temporal, and spectral resolution. Our particular work is focused on the evolution of inter-moss loops, which have been detected in the lower corona by the Atmospheric Imaging Assembly (AIA) and the High-Resolution Coronal Imager (Hi- C), but are known to have foot points below the transition region. With the high-resolution capabilities of IRIS and its Si IV pass band, which measures activity in the upper chromosphere, we can study these magnetic loops in detail and compare their characteristic length and time scales to those obtained from several AIA image sets, particularly the 171, 193, and 211 pass bands. By comparing the results between these four data sets, one can potentially establish a measure of the ionization equilibrium for the location in question. To explore this idea, we found a large, sit-and-stare observation within the IRIS database that fit our specifications. This data set contained a number of well-defined inter-moss loops (by visual inspection) with a cadence less than or equal to that of AIA (approximately 12 seconds). This particular data set was recorded on October 23, 2013 at 07:09:30, lasting for 3219 seconds with a field of view of 120.6 by 128.1 arcseconds, centered on -53.9 by 59.1 arcseconds from disk center. For ease of comparison, the AIA data has been interpolated to match the IRIS cadence and resolution. In the main portion of the poster, we demonstrate the detection of events, the information collected, and the immediate results to the right, showing the progress of an event with green as the start, blue as the peak, and red as the end. Below here, we demonstrate how pixels are combined to form groups. The 3D results are shown to the right.

event detection↗

Analysis of Inter-Moss Loops in the Solar Region with IRIS and SDO AIA: Automatic Event Detection and Characterization

The Interface Region Imaging Spectrograph (IRIS), launched in the summer of 2013, is designed specifically to observe and investigate the transition region and adjacent layers of the solar atmosphere, obtaining images in high spatial, temporal, and spectral resolution. Our particular work is focused on the evolution of inter-moss loops, which have been detected in the lower corona by the Atmospheric Imaging Assembly (AIA) and the High-Resolution Coronal Imager (Hi- C), but are known to have foot points below the transition region. With the high-resolution capabilities of IRIS and its Si IV pass band, which measures activity in the upper chromosphere, we can study these magnetic loops in detail and compare their characteristic length and time scales to those obtained from several AIA image sets, particularly the 171, 193, and 211 pass bands. By comparing the results between these four data sets, one can potentially establish a measure of the ionization equilibrium for the location in question. To explore this idea, we found a large, sit-and-stare observation within the IRIS database that fit our specifications. This data set contained a number of well-defined inter-moss loops (by visual inspection) with a cadence less than or equal to that of AIA (approximately 12 seconds). This particular data set was recorded on October 23, 2013 at 07:09:30, lasting for 3219 seconds with a field of view of 120.6 by 128.1 arcseconds, centered on -53.9 by 59.1 arcseconds from disk center. For ease of comparison, the AIA data has been interpolated to match the IRIS cadence and resolution. In the main portion of the poster, we demonstrate the detection of events, the information collected, and the immediate results to the right, showing the progress of an event with green as the start, blue as the peak, and red as the end. Below here, we demonstrate how pixels are combined to form groups. The 3D results are shown to the right

IRIS↗

Visualization and prediction of supercritical CO 2 distribution in sandstones during drainage: An in situ synchrotron X-ray micro-computed tomography study

Pore-scale distribution of supercritical CO 2 (scCO 2 ) exerts significant control on a variety of key hydrologic as well as geochemical processes, including residual trapping and dissolution. Despite such importance, only a small number of experiments have directly characterized the three-dimensional distribution of scCO 2 in geologic materials during the invasion (drainage) process. Here, we present a study which couples dynamic high-resolution synchrotron X-ray micro-computed tomography imaging of a scCO 2 /brine system at in situ pressure/temperature conditions with quantitative pore-scale modeling to allow direct validation of a pore-scale description of scCO2 distribution. The experiment combines high-speed synchrotron radiography with tomography to characterize the brine saturated sample, the scCO 2 breakthrough process, and the partially saturated state of a sandstone sample from the Domengine Formation, a regionally extensive unit within the Sacramento Basin (California, USA). The availability of a 3D dataset allowed us to examine correlations between grains and pores morphometric parameters and the actual distribution of scCO 2 in the sample, including the examination of the role of small-scale sedimentary structure on CO2 distribution. The segmented scCO 2 /brine volume was also used to validate a simple computational model based on the local thickness concept, able to accurately simulate the distribution of scCO 2 after drainage. The same method was also used to simulate Hg capillary pressure curves with satisfactory results when compared to the measured ones. Finally, this predictive approach, requiring only a tomographic scan of the dry sample, proved to be an effective route for studying processes related to CO 2 invasion structure in geological samples at the pore scale.

3D quantitative morphometric analysis↗

Development of an accelerator-based neutron source to prototype Mo-99 production, part I: A liquid LBE windowless target

In this article, Molybdenum-99 (Mo-99)’s decay product, technetium-99 (Tc-99 m), is one of the most critical isotopes for medical diagnostics. To provide U.S. domestic supply of Mo-99 without using high-enriched uranium (HEU), a subcritical uranium target assembly (UTA) is irradiated by an accelerator-based neutron source to create Mo-99 through fission. This study discusses the development of the accelerator-based neutron source. The high-energy electrons from the accelerator irradiate a liquid lead-bismuth eutectic (LBE) target to produce neutrons. Part I of this work focuses on numerical and experimental analysis towards the development of a liquid LBE windowless target. Unlike the existing windowless targets in literature, the current design creates a vertical free surface for a beam to irradiate. First, a hydrodynamic analysis of the LBE windowless target is performed. Simplified analytical calculations are assisted by 2D computational fluid dynamics (CFD) simulations to design the target, with the focus on eliminating recirculation zones and avoiding cavitation. With the optimized geometry, the experimental study is performed to investigate the flow hydrodynamics using liquid LBE. The experiments (1) compare pressure drop in the system to correlation predictions; (2) visualize the free surface liquid LBE flow from the beam view; (3) validate the LBE flow profile using temperature sensitive paint from the side view; and (4) validate the liquid LBE film thickness using gamma densitometer measurements. Second, the power handling capability of the designed windowless target is investigated. The divider plate in the current design is susceptible to overheating due to the thin LBE film in front. As LBE erosion and corrosion is likely to occur at an LBE velocity of 2.0 m/s and temperature above 500 °C, a power limit of 10 kW of beam power was established to prevent this corrosion from occurring, which is calculated by a Nusselt number correlation. The divider plate surface temperature at 10 kW agrees well with the 3D CFD simulation results. Part I demonstrates the fundamental physics in liquid LBE windowless target design and associated testing. A companion paper, Part II will demonstrate how to couple this windowless target into the Mo-99 production system, including an accelerator system operating under an ultra-high vacuum and the UTA cooled by water at room temperature.

43 PARTICLE ACCELERATORS↗

Deep-learning-based workflow for boundary and small target segmentation in digital rock images using UNet++ and IK-EBM

We report three-dimensional (3D) X-ray micro-computed tomography (μCT) has been widely used in petroleum engineering because it can provide detailed pore structural information for a reservoir rock, which can be imported into a pore-scale numerical model to simulate the transport and distribution of multiple fluids in the pore space. The partial volume blurring (PVB) problem is a major challenge in segmenting raw μCT images of rock samples, which impacts boundaries and small targets near the resolution limit. We developed a deep-learning (DL)-based workflow for accurate and fast partial volume segmentation. The DL model's performance depends primarily on the training data quality and model architecture. This study employed the entropy-based-masking indicator kriging (IK-EBM) to segment 3D Berea sandstone images as training datasets. The comparison between IK-EBM and manual segmentation using a 3D synthetic sphere pack, which had a known ground truth, showed that IK-EBM had higher accuracy on partial volume segmentation. We then trained and tested the UNet++ model, a state-of-the-art supervised encoder-decoder model, for binary (i.e., void and solid) and four-class segmentation. We compared the UNet++ with the commonly used U-Net and wide U-Net models and showed that the UNet++ had the best performance in terms of pixel-wise and physics-based evaluation metrics. Specifically, boundary-scaled accuracy demonstrated that the UNet++ architecture outperformed the regular U-Net architecture in the segmentation of pixels near boundaries and small targets, which were subjected to the PVB effect. Feature map visualization illustrated that the UNet++ bridged the semantic gaps between the feature maps extracted at different depths of the network, thereby enabling faster convergence and more accurate extraction of fine-scale features. The developed workflow significantly enhances the performance of supervised encoder-decoder models in partial volume segmentation, which has extensive applications in fundamental studies of subsurface energy, water, and environmental systems.

02 PETROLEUM↗