Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vaporizing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

A comparison of ER-2 measurements of stratospheric water vapor between the 1987 Antarctic and 1989 Arctic Airborne missions

Vertical profiles of water vapor inside the Antarctic vortex have been compared with those taken outside it over Punta Arenas (53 deg S, 71 deg W). A similar exercise was performed with Arctic vortex profiles and those taken over Stavanger (59 deg N, 6 deg E). Residual water, defined as the stratospheric water vapor mixing ratio with the contribution from methane oxidation subtracted, is also shown as profiles inside and outside the vortex for both missions. The Arctic and Antarctic profiles of water vapor and residual water are compared. Locally dehydrated air was evident both inside and outside the Antarctic vortex, but such dehydration was not evident in and around the Arctic vortex. Arctic profiles of residual water are consistent with nontropical entry for some air.

Kelly, K. K.↗

Observation of a strong inverse temperature dependence for the opacity of atmospheric water vapor in the mm continuum near 280 GHz

Results are presented of the field measurements of atmospheric opacity at 278 GHz (9.3/cm) conducted at the McMurdo Station (Antarctica) during the austral springs of 1986 and 1987, in conjunction with balloon measurements of water vapor profile and total column density, showing a strong inverse temperature dependence when normalized to precipitable water vapor. The value of measured opacity per mm of precipitable water vapor (PWV) is roughly two times greater at -35 C than at -10 C and three times greater than measurements at +25 C reported by Zammit and Ade (1981). Various theories proposed to explain excess absorption in continuum regions are reviewed.

Emmons, Louisa K.↗

LOX vaporization in high-pressure, hydrogen-rich gas

LOX droplet vaporization in high-pressure hydrogen-rich gas is analyzed, with special attention to thermodynamic effects which compel the surface to heat to the critical state and to supercritical vaporization processes on heating to criticality. Subcritical vaporization is modeled using a quasi-steady diffusion-controlled gas-phase transport formulation coupled to an effective-conductivity internal-energy-transport model accounting for circulation effects. It is demonstrated how the droplet surface might heat to the critical state, for ambient pressures slightly greater than the critical pressure of oxygen, such that the bulk of propellant within the droplet remains substantially below the critical mixing temperature.

Litchford, Ron J.↗

In situ measurement of water vapor in the stratosphere with a cryogenically cooled Lyman-alpha hygrometer

In situ measurements of water vapor in the stratosphere with a new instrument are reported. The instrument has been designed to observe daytime water vapor from a multiinstrument balloon gondola that simultaneously measures free radicals such as OH, HO2, and O3 in the stratosphere up to 40 km. Lyman-alpha photofragment fluorescence is used to measure water molecules in a flowing sample of ambient air. A brief description of the instrument is given, followed by the results of the first four balloon flights. The measured mixing ratio for this flight varies from 3.0-5.5 ppmv over the altitude range of 17-34 km. Adjustments in the cooling protocol for the flights of July 6, 1988, July 28, and August 25, 1989, result in a much higher signal-to-noise ratio. Profiles from these three flights are similar to, but somewhat higher, than the 1987 profile. Implications of measurements are discussed, as are the issues of short- and long-term variability of stratospheric water vapor.

Schwab, J. J.↗

Vapor-Resistant Heat-Pipe Artery

Vapor lock in heat pipe delayed or prevented. Modifications of wick prevent flow of vapor into, or formation of vapor in, liquid-return artery. Small pores of fine-grained sintered wick help to prevent formation of large bubbles. Slotted tube offers few nucleation sites for bubbles. Improves return of liquid in heat pipe.

Dussinger, Peter M.↗

Preventing Chemical-Vapor Deposition In Selected Areas

Method for prevention of chemical-vapor deposition of material in selected areas developed. Gas shroud isolates specific area from rest of deposition system. Inert gas flowing from beneath substrate prevents deposition between substrate and outer ring. Method extremely successful in selective deposition of SiC in chemical-vapor-deposition reactor. Used in deposition of SiC mirror blanks in Large Mirror Substrate and Lidar Mirror programs. Critical element in overall chemical-vapor-deposition process for producing large, lightweight mirrors.

Keeley, Joseph T.↗

Vacuum vapor deposition: A spinoff of space welding development

A vapor deposition process has been defined through a spinoff effort of space welding development. In this development for welding in a space environment, a hollow electrode was used to add gas precisely at the welding arc. This provides gas for ionization which carries the welding arc current. During this welding development metal vapor coatings were observed. These coatings are unique in that they are produced by a new process. Some coatings produced and the potential of this new and innovative vapor deposition process are characterized. Advantages over prior art are discussed.

Poorman, R. M.↗

Pressure drop in fully developed, duct flow of dispersed liquid-vapor mixture at zero gravity

The dynamics of steady, fully developed dispersed liquid-vapor flow in a straight duct at 0-g is simulated by flowing water containing n-butyl benzoate droplets. Water and benzoate are immiscible and have identical density at room temperature. The theoretical basis of the simulation is given. Experiments showed that, for a fixed combined flow rate of water and benzoate, the frictional pressure drop is unaffected by large changes in the volume fraction of benzoate drops and their size distribution. Measured power spectra of the static wall pressure fluctuations induced by the turbulent water-benzoate flow also revealed that their dynamics is essentially unaltered by the presence of the droplets. These experimental findings, together with the theoretical analysis, led to the conclusion that the pressure drop in fully developed, dispersed liquid-vapor flow in straight ducts of constant cross section at 0-g is identical to that due to liquid flowing alone at the same total volumetric flow rate of the liquid-vapor mixture and, therefore, can be readily determined.

Sridhar, K. R.↗

Stratospheric profiles of heavy water vapor isotopes and CH3D from analysis of the ATMOS Spacelab 3 infrared solar spectra

The isotopic composition of stratospheric water vapor and methane was investigated. Stratospheric profiles of HDO, (H-18)2O, (H-17)2O, and CH3D were derived from solar occultation spectra recorded on April 30 - May 1, 1985 by the Atmospheric Trace Molecule Spectroscopy Fourier transform spectrometer aboard Spacelab 3. The profiles of the three water-vapor isotopes showed an increase in the volume mixing ratio with altitude. The measured profiles of D/H in water vapor showed a large depletion in the lower stratosphere (about 63 percent relative to standard mean ocean water, SMOW, at 20 km) and a small increase in D/H with altitude at higher altitudes, up to 34 km. The D/H ratio in stratospheric methane was close to the corresponding isotopic ratio in SMOW.

Rinsland, C. P.↗

Geodesy by radio interferometry - Water vapor radiometry for estimation of the wet delay

An important source of error in VLBI estimates of baseline length is unmodeled variations of the refractivity of the neutral atmosphere along the propagation path of the radio signals. This paper presents and discusses the method of using data from a water vapor radiomete (WVR) to correct for the propagation delay caused by atmospheric water vapor, the major cause of these variations. Data from different WVRs are compared with estimated propagation delays obtained by Kalman filtering of the VLBI data themselves. The consequences of using either WVR data or Kalman filtering to correct for atmospheric propagation delay at the Onsala VLBI site are investigated by studying the repeatability of estimated baseline lengths from Onsala to several other sites. The repeatability obtained for baseline length estimates shows that the methods of water vapor radiometry and Kalman filtering offer comparable accuracies when applied to VLBI observations obtained in the climate of the Swedish west coast. For the most frequently measured baseline in this study, the use of WVR data yielded a 13 percent smaller weighted-root-mean-square (WRMS) scatter of the baseline length estimates compared to the use of a Kalman filter. It is also clear that the 'best' minimum elevationi angle for VLBI observations depends on the accuracy of the determinations of the total propagation delay to be used, since the error in this delay increases with increasing air mass.

Elgered, G.↗

Determination of total column water vapor in the atmosphere at high spatial resolution from AVIRIS data using spectral curve fitting and band ratioing techniques

Techniques are developed for quantitative retrievals of high spatial resolution column atmospheric water vapor that is largely contained in the lower portion of the troposphere. One method consists of curve fitting observed spectra with simulated spectra in the 1.14 microns or the 0.94 micron water vapor band absorption region. The other method is a simple band ratioing technique, which requires less computer time than the curve fitting method. The advantage of the technique over humidity sounding by IR emission measurements is that the retrieved column water vapor amounts over land surfaces have significantly higher precision.

Gao, Bo-Cai↗

Pressure-coupled vaporization and combustion responses of liquid-fuel droplets in high-pressure environments

The dynamic responses of liquid-fuel droplet vaporization and combustion to ambient pressure oscillations are examined. The analysis is based on the complete sets of conservation equations for both gas and liquid phases, and accommodates detailed treatments of finite-rate chemical kinetics and variable properties. With a full account of thermodynamic phase equilibrium at the droplet surface, the model enables a systematic examination of the effects of ambient flow conditions on the droplet behavior. The responses of hydrocarbon fuel droplets in both sub- and super-critical environments are investigated. Results indicate that the droplet gasification and burning mechanisms depend greatly on the ambient pressure. In particular, a rapid enlargement of the vaporization and combustion responses occurs when the droplet surface reaches its critical point, mainly due to the strong variations of latent heat of vaporization and thermophysical properties at the critical state.

Yang, Vigor↗

Tunable 2.1-micron Ho lidar for simultaneous range-resolved measurements of atmospheric water vapor and aerosol backscatter profiles

An eye-safe tunable differential-absorption lidar system has been developed for the range-resolved measurement of aerosol backscatter and water vapor in the atmosphere. The lidar uses a flash-lamp-pumped, Q-switched, 10-mJ solid-state Ho:YSGG laser that is continuously tunable over a 20/cm wavelength range near 2.084 microns. Both path-averaged and range-resolved measurements were performed with the Ho differential-absorption lidar system. Preliminary measurements have been made of the temporal variation of atmospheric aerosol backscatter and water-vapor profiles at ranges out to 1 km. These results indicate that the Ho lidar has the potential for the eye-safe remote sensing of atmospheric water vapor and backscatter profiles at longer ranges if suitably enhanced in laser power and laser linewidth.

Cha, Sungdo↗

Vapor core propulsion reactors

Many research issues were addressed. For example, it became obvious that uranium tetrafluoride (UF4) is a most preferred fuel over uranium hexafluoride (UF6). UF4 has a very attractive vaporization point (1 atm at 1800 K). Materials compatible with UF4 were looked at, like tungsten, molybdenum, rhenium, carbon. It was found that in the molten state, UF4 and uranium attacked most everything, but in the vapor state they are not that bad. Compatible materials were identified for both the liquid and vapor states. A series of analyses were established to determine how the cavity should be designed. A series of experiments were performed to determine the properties of the fluid, including enhancement of the electrical conductivity of the system. CFD's and experimental programs are available that deal with most of the major issues.

Diaz, Nils J.↗

A Planar-Fluorescence Imaging Technique for Studying Droplet-Turbulence Interactions in Vaporizing Sprays

Droplet turbulence interactions directly affect the vaporization and dispersion of droplets in liquid sprays and therefore play a major role in fuel oxidizer mixing in liquid fueled combustion systems. Proper characterization of droplet turbulence interactions in vaporizing sprays require measurement of droplet size velocity and size temperature correlations. A planar, fluorescence imaging technique is described which is being developed for simultaneously measuring the size, velocity, and temperature of individual droplets in vaporizing sprays. Preliminary droplet size velocity correlation measurements made with this technique are presented. These measurements are also compared to and show very good agreement with measurements made in the same spray using a phase Doppler particle analyzer.

Santavicca, Dom A.↗

Monolithic microwave integrated circuit water vapor radiometer

A proof of concept Monolithic Microwave Integrated Circuit (MMIC) Water Vapor Radiometer (WVR) is under development at the Jet Propulsion Laboratory (JPL). WVR's are used to remotely sense water vapor and cloud liquid water in the atmosphere and are valuable for meteorological applications as well as for determination of signal path delays due to water vapor in the atmosphere. The high cost and large size of existing WVR instruments motivate the development of miniature MMIC WVR's, which have great potential for low cost mass production. The miniaturization of WVR components allows large scale deployment of WVR's for Earth environment and meteorological applications. Small WVR's can also result in improved thermal stability, resulting in improved calibration stability. Described here is the design and fabrication of a 31.4 GHz MMIC radiometer as one channel of a thermally stable WVR as a means of assessing MMIC technology feasibility.

Sukamto, L. M.↗

Metal oxide absorbents for regenerative carbon dioxide and water vapor removal for advanced portable life support systems

Recent studies of Allied Signal metal oxide based absorbents demonstrated that these absorbents offer a unique capability to regeneratively remove both metabolic carbon dioxide and water vapor from breathing air; previously, metal oxides were considered only for the removal of CO2. The concurrent removal of CO2 and H2O vapor can simplify the astronaut Portable Life Support System (PLSS) by combining the CO2 and humidity control functions into one regenerative component. The use of metal oxide absorbents for removal of both CO2 ad H2O vapor in the PLSS is the focus of an ongoing program. The full scale Metal Oxide Carbon dioxide and Humidity Remover (MOCHR) and regeneration unit is described.

Hart, Joan M.↗

Airborne remote sensing of tropospheric water vapor using a near infrared DIAL system

Summarized here are the results of airborne water vapor measurements in the lower middle and upper troposphere using the Differential Absorption Lidar (DIAL) technique in the near infrared. The measurements were performed in July 1990 in Southern Bavaria between Allersberg and Straubing from 20 to 23 UTC taking advantage of night time conditions. The tropospheric H2O profiles were range investigated both horizontally and vertically. With the DIAL system that was used, water vapor measurements in the upper troposphere have been carried out for the first time. To calibrate the H2O-retrievals, effective absorption cross sections of selected H2O lines in terms of altitude around 724 nm were calculated using line parameter data from the literature (B. E. Grossmann et al). The frequency of the on-line measurements was adjusted by the spectra of a Polyacenic Semiconductor (PAS) cell filled with H2O. We found that the calibration error ranged between 0.005 and 0.015 cm(exp -1). The systematic errors of the H2O as a function of altitude were estimated below 7 km and 12 percent accuracy in the upper troposphere. The vertical H2O profile agrees well with in situ measurements in the investigated range between the top of the planetary boundary layer (PBL) up to near the tropopause. Horizontal and vertical H2O profiles are calculated by means of averaging single lidar returns. Typical horizontal resolutions range from 4 km in the lower to 11 km in the upper troposphere with vertical resolutions varying from 0.3 km up to 1 km, respectively, in order to satisfy a 5 - 10 percent accuracy in the statistical error. The measurement sensibility of the water vapor mixing ration in the upper troposphere is 0.01 g/kg.

Ehret, G.↗