Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transport computer code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Transformation of Spinors in Accelerators and Beam Transfer Lines

The stable spin direction and the spin tune are two important concepts used when polarized beams are transferred along beam lines or circulating in an accelerator. One of the methods to calculate the stable spin direction and the spin tune of the reference particle of a polarized beam bunch is by integrating simultaneously the Lorentz Force $\vec{F}$ = q($\vec{E}$ +$\vec{v}$ x $\vec{B}$) and the BMT equation of the reference particle as it is transported by the magnets of a beam line or accelerator. A modified version of the Raytrace code was used to integrate the Lorentz equation and the BMT equation. Using the spin motion which is governed by the BMT equation one can compute both, the stable spin direction of the reference particle at any point along the reference orbit of an accelerator or a beam line, and the spin tune of the closed orbit in an accelerator. The simultaneous integration of the Lorentz force and of the BMT equation is the most accurate method to calculate the trajectory and the spin motion of a charged particle moving in an electromagnetic field, however this method requires the accurate description of the electromagnetic fields of the elements in which the charged particles are moving. An alternative method of calculating the stable spin direction and the spin tune of spin ½ charged particles along the reference trajectory of a beam line or an accelerator is the transformation of the spinor which is the wavefunction of spin ½ particles. This method requires the knowledge of the stable spin direction of each element of the beam line or the accelerator. This technical note describes the “spinor-method” to calculate the stable-spin- direction and the spin-tune of a spin ½ particle moving along the reference trajectory of a beam line or an accelerator.

43 PARTICLE ACCELERATORS↗

EMPIRE Simulations of the July 2020 photoelectron driven cavity B-Dot experiments at the National Ignition Facility

Simulations of several of the end-irradiated cylindrical photoelectron driven cavity experiments (also known as B-Dot cavities) that were fielded during the July 1 through 2, 2020 shot series at the National Ignition Facility are presented in this report with comparisons to experimental measurements. All cavity B-Dots fielded on the second, third, fourth, fifth and seventh shots were simulated using coupled Integrated Tiger Series (ITS) Monte Carlo transport codes and the Electromagnetic Plasmas in Realistic Environments (EMPIRE) electromagnetic particle-in-cell code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MCNP6.3: A Year in Review [Slides]

This presentation discusses the past year and the many accomplishments of the MCNP6.3 team. It states that the MCNP6.3 release is imminent and that the approved, final documents have been making their way to the website. The code executables and source are already packaged up for distribution and the new installer is being finalized and tested now, for all platforms. The package will be sent to RSICC before the end of October 2022. Additionally, the presentation discusses some things to think about as MCNP6.3 is requested and/or used. For example, many of the recent efforts have been focused on making development, updates, and distribution of the code and documents more robust and streamlined. They will be revising/updating documents more frequently than ever before and they will be exploring avenues to distribute official patches to MCNP6.3. As they explain, this allows them to be more responsive to bugs and issues that are identified. In conclusion, the application of a patch to MCNP6.3 will require having the source code.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Evaluation of SNS Beamline Shielding Configurations using MCNPX Accelerated by ADVANTG

Shielding analyses for the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory pose significant computational challenges, including highly anisotropic high-energy sources, a combination of deep penetration shielding and an unshielded beamline, and a desire to obtain well-converged nearly global solutions for mapping of predicted radiation fields. The majority of these analyses have been performed using MCNPX with manually generated variance reduction parameters (source biasing and cell-based splitting and Russian roulette) that were largely based on the analyst's insight into the problem specifics. Development of the variance reduction parameters required extensive analyst time, and was often tailored to specific portions of the model phase space. We previously applied a developmental version of the ADVANTG code to an SNS beamline study to perform a hybrid deterministic/Monte Carlo analysis and showed that we could obtain nearly global Monte Carlo solutions with essentially uniform relative errors for mesh tallies that cover extensive portions of the model with typical voxel spacing of a few centimeters. The use of weight window maps and consistent biased sources produced using the FW-CADIS methodology in ADVANTG allowed us to obtain these solutions using substantially less computer time than the previous cell-based splitting approach. While those results were promising, the process of using the developmental version of ADVANTG was somewhat laborious, requiring user-developed Python scripts to drive much of the analysis sequence. In addition, limitations imposed by the size of weight-window files in MCNPX necessitated the use of relatively coarse spatial and energy discretization for the deterministic Denovo calculations that we used to generate the variance reduction parameters. We recently applied the production version of ADVANTG to this beamline analysis, which substantially streamlined the analysis process. We also tested importance function collapsing (in space and energy) capabilities in ADVANTG. These changes, along with the support for parallel Denovo calculations using the current version of ADVANTG, give us the capability to improve the fidelity of the deterministic portion of the hybrid analysis sequence, obtain improved weight-window maps, and reduce both the analyst and computational time required for the analysis process.

43 PARTICLE ACCELERATORS↗

Shift: A Massively Parallel Monte Carlo Radiation Transport Package

This paper discusses the massively-parallel Monte Carlo radiation transport package, Shift, developed at Oak Ridge National Laboratory. It reviews the capabilities, implementation, and parallel performance of this code package. Scaling results demonstrate very good strong and weak scaling behavior of the implemented algorithms. Benchmark results from various reactor problems show that Shift results compare well to other contemporary Monte Carlo codes and experimental results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental and theoretical dosimetry of a new polymer encapsulated iodine-125 source--SmartSeed: Dosimetric impact of fluorescence x rays

Purpose: The detailed study of a new permanent iodine-125 brachytherapy source, SmartSeed, is presented in this article. It is the first iodine seed made with biocompatible polymer and is manufactured by the IBt-Bebig group. Methods: Three dosimetric studies have been performed: The first one used thermoluminescent detectors in a solid water phantom with NIST (National Institute of Standards and Technology, USA) calibrated seeds, and two separate studies were of Monte Carlo photon transport calculations (MCNP5 code). The TG-43U1 protocol was applied to derive dosimetric parameters for clinical applications. Results: The radial dose function g(r) was determined at different distances ranging from 0.5 to 10 cm; and the anisotropy function F(r,{theta}) at angles ranging from 0 deg. to 350 deg. in 10 deg. increments. Monte Carlo calculations were performed in liquid water to obtain values for {Lambda}, g(r), F(r,{theta}), and {phi}{sub an}(r) as recommended by the TG-43U1 protocol for use in treatment planning system software. SmartSeed's biocompatible polymer capsule permits fluorescence x rays (3, 5, and 12 keV), generated by lead glass marker, to be present in the emission spectrum, influencing the dose rate constant. The impact on near field dosimetry in water from these x rays was also investigated and reported. The capsule also attenuates iodine-125 energies much less than typical titanium encased sources, resulting in a highly isotropic source. Conclusions: SmartSeed has a dose rate constant of 0.895{+-}7.3% cGy h{sup -1} U{sup -1}, a radial dose function nearly identical to the IBt-Bebig model I25.S06 seed, and a highly isotropic dose distribution. Fluorescence x rays account for the relatively low value of {Lambda}, yet their variable contribution to dosimetry arising from seed dimensional uncertainties is estimated to be <0.2%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modelling an induced thermal plume with data from electrical resistivity tomography and distributed temperature sensing: a case study in northeast Italy

Groundwater tracer tests are often used to improve aquifer characterization, but they present several disadvantages, such as the need to pour solutions or dyes into the aquifer system and alteration of the water’s chemical properties. Thus, tracers can affect the groundwater flow mechanics and data interpretation becomes more complex, hindering effective study of ground heat pumps for low enthalpy geothermal systems. This paper presents a preliminary methodology based on a multidisciplinary application of heat as a tracer for defining the main parameters of shallow aquifers. The field monitoring techniques electrical resistivity tomography (ERT) and distributed temperature sensing (DTS) are noninvasive and were applied to a shallow-aquifer test site in northeast Italy. The combination of these measurement techniques supports the definition of the main aquifer parameters and therefore the construction of a reliable conceptual model, which is then described through the numerical code FEFLOW. This model is calibrated with DTS and validated by ERT outcomes. The reliability of the numerical model in terms of fate and transport is thereby enhanced, leading to the potential for better environmental management and protection of groundwater resources through more cost-effective solutions.

54 ENVIRONMENTAL SCIENCES↗

Challenges of Monte Carlo Transport

These are slides from a presentation for Parallel Summer School at Los Alamos National Laboratory. Solving discretized partial differential equations (PDEs) of interest can require a large number of computations. We can identify concurrency to allow parallel solution of discrete PDEs. Simulated particles histories can be used to solve the Boltzmann transport equation. Particle histories are independent in neutral particle transport, making them amenable to parallel computation. Physical parameters and method type determine the data dependencies of particle histories. Data requirements shape parallel algorithms for Monte Carlo. Then, Parallel Computational Physics and Parallel Monte Carlo are discussed and, finally, the results are given. The mesh passing method greatly simplifies the IMC implementation and allows simple load-balancing. Using MPI windows and passive, one-sided RMA further simplifies the implementation by removing target synchronization. The author is very interested in implementations of PGAS that may allow further optimization for one-sided, read-only memory access (e.g. Open SHMEM). The MPICH_RMA_OVER_DMAPP option and library is required to make one-sided messaging scale on Trinitite - Moonlight scales poorly. Interconnect specific libraries or functions are likely necessary to ensure performance. BRANSON has been used to directly compare the current standard method to a proposed method on idealized problems. The mesh passing algorithm performs well on problems that are designed to show the scalability of the particle passing method. BRANSON can now run load-imbalanced, dynamic problems. Potential avenues of improvement in the mesh passing algorithm will be implemented and explored. A suite of test problems that stress DD methods will elucidate a possible path forward for production codes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gasificaton Transport: A Multiphase CFD Approach & Measurements

The objective of this project was to develop predictive theories for the dispersion and mass transfer coefficients and to measure them in the turbulent fluidization regime, using existing facilities. A second objective was to use our multiphase CFD tools to suggest optimized gasifier designs consistent with aims of Future Gen. We have shown that the kinetic theory based CFD codes correctly compute: (1) Dispersion coefficients; and (2) Mass transfer coefficients. Hence, the kinetic theory based CFD codes can be used for fluidized bed reactor design without any such inputs. We have also suggested a new energy efficient method of gasifying coal and producing electricity using a molten carbonate fuel cell. The principal product of this new scheme is carbon dioxide which can be converted into useful products such as marble, as is done very slowly in nature. We believe this scheme is a lot better than the canceled FutureGen, since the carbon dioxide is safely sequestered.

01 COAL, LIGNITE, AND PEAT↗

Sensitivity and uncertainty analysis for a combined depletion and criticality calculation chain of a BWR FA

This paper examines the prerequisites and boundary conditions for extending burnup credit from pressurized water reactors to boiling water reactors with validated depletion codes by performing uncertainty and sensitivity analyses on a modern boiling water reactor fuel assembly design. We developed a computational chain consisting of an axial boiling water reactor axial irradiation model, followed by a series of depletion calculations and a three-dimensional criticality calculation. The irradiation model puts into relation the profiles of power, burnup and moderator density of the fuel assembly at 24 axial locations. In a simplified fashion it also includes the insertion of control blades. The depletion calculations of the fuel assembly were performed in axial slices with the 2D-depletion code HELIOS 1.12. The criticality calculations were done in 3D-geometry with KENO-Va from the SCALE 6.2.1 package, in which several fuel assemblies are placed into a generic transport cask. For the uncertainty and sensitivity analyses a Monte Carlo sampling based approach is used applying the GRS tool SUnCISTT. We performed several generic investigations testing the capabilities and the limitations of the whole computational chain. The impact of variations of the irradiation model on the resulting reactivity of the fuel assemblies inside a transport cask or storage pool was investigated using an uncertainty and sensitivity analysis on the whole computational chain. Geometrical uncertainties were also included in the evaluation and a parameter study on the use of control blades during irradiation was performed. The goal was to develop the procedures and tools to be able to obtain quantitative uncertainty data which can be used in the future to derive conservative irradiation profiles without unnecessary excess reactivity margins. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclide Depletion Capabilities in the Shift Monte Carlo Code

A new depletion capability has been developed in the Exnihilo radiation transport code suite. This capability enables massively parallel domain-decomposed coupling between the Shift continuous-energy Monte Carlo solver and the nuclide depletion solvers in ORIGEN to perform high-performance Monte Carlo depletion calculations. This paper describes this new depletion capability and discusses its various features, including a multi-level parallel decomposition, high-order transport-depletion coupling, and energy-integrated power renormalization. Several test problems are presented to validate the new capability against other Monte Carlo depletion codes, and the parallel performance of the new capability is analyzed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling of particle transport, neutrals and radiation in magnetically-confined plasmas with Aurora

In this work, we present Aurora, an open-source package for particle transport, neutrals and radiation modeling in magnetic confinement fusion plasmas. Aurora's modern multi-language interface enables simulations of 1.5D impurity transport within high-performance computing frameworks, particularly for the inference of particle transport coefficients. A user-friendly Python library allows simple interaction with atomic rates from the Atomic Data and Atomic Structure database as well as other sources. This enables a range of radiation predictions, both for power balance and spectroscopic analysis. We discuss here the superstaging approximation for complex ions, as a way to group charge states and reduce computational cost, demonstrating its wide applicability within the Aurora forward model and beyond. Aurora also facilitates neutral particle analysis, both from experimental spectroscopic data and other simulation codes. Leveraging Aurora's capabilities to interface SOLPS-ITER results, we demonstrate that charge exchange is unlikely to affect the total radiated power from the ITER core during high performance operation. Finally, we describe the ImpRad module in the one modeling framework for integrated task framework, developed to enable experimental analysis and transport inferences on multiple devices using Aurora.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diffusive deposition of aerosols in Phebus containment during FPT-2 test

At present the lumped-parameter codes is the main tool to investigate the complex response of the containment of Nuclear Power Plant in case of an accident. Continuous development and validation of the codes is required to perform realistic investigation of the processes that determine the possible source term of radioactive products to the environment. Validation of the codes is based on the comparison of the calculated results with the measurements performed in experimental facilities. The most extensive experimental program to investigate fission product release from the molten fuel, transport through the cooling circuit and deposition in the containment is performed in PHEBUS test facility. Test FPT-2 performed in this facility is considered for analysis of processes taking place in containment. Earlier performed investigations using COCOSYS code showed that the code could be successfully used for analysis of thermal-hydraulic processes and deposition of aerosols, but there was also noticed that diffusive deposition on the vertical walls does not fit well with the measured results. In the CPA module of ASTEC code there is implemented different model for diffusive deposition, therefore the PHEBUS containment model was transferred from COCOSYS code to ASTEC-CPA to investigate the influence of the diffusive deposition modelling. Analysis was performed using PHEBUS containment model of 16 nodes. The calculated thermal-hydraulic parameters are in good agreement with measured results, which gives basis for realistic simulation of aerosol transport and deposition processes. Performed investigations showed that diffusive deposition model has influence on the aerosol deposition distribution on different surfaces in the test facility. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-throughput screening of hypothetical metal-organic frameworks for thermal conductivity

Thermal energy management in metal-organic frameworks (MOFs) is an important, yet often neglected, challenge for many adsorption-based applications such as gas storage and separations. Despite its importance, there is insufficient understanding of the structure-property relationships governing thermal transport in MOFs. To provide a data-driven perspective into these relationships, here we perform large-scale computational screening of thermal conductivity k in MOFs, leveraging classical molecular dynamics simulations and 10,194 hypothetical MOFs created using the ToBaCCo 3.0 code. We found that high thermal conductivity in MOFs is favored by high densities (> 1.0 g cm -3 ), small pores (< 10 Å), and four-connected metal nodes. We also found that 36 MOFs exhibit ultra-low thermal conductivity (< 0.02 W m -1 K -1 ), which is primarily due to having extremely large pores (~65 Å). Furthermore, we discovered six hypothetical MOFs with very high thermal conductivity (>10 Wm -1 K -1 ), the structures of which we describe in additional detail.

36 MATERIALS SCIENCE↗

Dose Rate Evaluation for the ES-3100 Package with HEU Content Using MCNP, ADVANTG, Monaco, and MAVRIC

Here, this paper presents a comparative study of dose rate calculations for the ES-3100 package with highly enriched uranium (HEU) content for different source configurations using computer codes: (1) MCNP; (2) Automated Variance Reduction Generator (ADVANTG)/MCNP; (3) Monaco; and (4) Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC). The Model ES-3100 package was developed at the Y-12 National Security Complex for domestic and international transportation of Type B fissile radioactive material. In this study, six different source configurations (i.e., solid cylinder, cylindrical hemi-shell, cylindrical shell, rectangular plate, cylindrical rod, or cylindrical segment form) having 36 kg of HEU metal inside the package containment vessel (based on configurations in the ES-3100/HEU safety analysis report for packaging) are evaluated. Dose rates at the package surfaces and 1 m from the package surfaces are calculated for these different source configurations. MCNP and Monaco cases are run without any biasing options to accelerate the convergence. Consistent Adjoint Driven Importance Sampling (CADIS) and Forward-Weighted CADIS (FW-CADIS) methods developed at the Oak Ridge National Laboratory are implemented in ADVANTG/MCNP and MAVRIC codes to accelerate the convergence. ADVANTG generates variance reduction parameters using Denovo code, and MCNP is used with the variance reduction parameters to accelerate the convergence. MAVRIC uses Denovo code to construct an importance map and a biased source distribution that are supplied to Monaco to accelerate the Monte Carlo simulation. The FW-CADIS option in ADVANTG and MAVRIC is used to accelerate the convergence in this study. The accelerated convergence cases (ADVANTG/MCNP and MAVRIC) are about 100 times faster with 100 times less particle simulation than those cases run without biasing options (analog MCNP and analog Monaco). Lastly, the MCNP, ADVANTG/MCNP, Monaco, and MAVRIC calculated dose rates at the package surfaces and at 1 m from the package surfaces for the different source configurations are compared and are found to be in general agreement.

42 ENGINEERING↗

TOUGHREACT V4.12

TOUGHREACT V4.12 is a 3-D reactive transport code that handles to non-isothermal, multiphase/multicomponent fluid flow, heat transport, aqueous and gaseous species advection-diffusion, and equilibrium/kinetic water-gas-rock-biological reactions. TOUGHREACT V4.12 is based on TOUGHREACT V3.3, with several new features including: an option to compute activity coefficients using the Pitzer ion interaction model; implementation of ECO2N V2.0 for temperatures up to 300 C; options to simulate forward and reverse osmosis, including 2D Poiseuille flow; addition of EOS8 and revisions for EOS5 and EWASG with H2(g); addition of gas species decay, various new output formats and time step control options; many bug fixes.

Spycher, Nicolas↗

Dose Rate Evaluation for the ES-3100 Package with HEU Content Using MCNP, ADVANTG, Monaco, and MAVRIC

This paper presents a comparative study of dose rate calculations for the ES-3100 package with highly enriched uranium (HEU) content for different source configurations using computer codes: (1) MCNP; (2) Automated Variance Reduction Generator (ADVANTG)/MCNP; (3) Monaco; and (4) Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC). The Model ES-3100 package was developed at the Y-12 National Security Complex for domestic and international transportation of Type B fissile radioactive material. In this study, six different source configurations (i.e., solid cylinder, cylindrical hemi-shell, cylindrical shell, rectangular plate, cylindrical rod, or cylindrical segment form) having 36 kg of HEU metal inside the package containment vessel (based on configurations in the ES-3100/HEU safety analysis report for packaging) are evaluated. Dose rates at the package surfaces and 1 m from the package surfaces are calculated for these different source configurations. MCNP and Monaco cases are run without any biasing options to accelerate the convergence. Consistent Adjoint Driven Importance Sampling (CADIS) and Forward-Weighted CADIS (FW-CADIS) methods developed at the Oak Ridge National Laboratory are implemented in ADVANTG/MCNP and MAVRIC codes to accelerate the convergence. ADVANTG generates variance reduction parameters using Denovo code, and MCNP is used with the variance reduction parameters to accelerate the convergence. MAVRIC uses Denovo code to construct an importance map and a biased source distribution that are supplied to Monaco to accelerate the Monte Carlo simulation. The FW-CADIS option in ADVANTG and MAVRIC is used to accelerate the convergence in this study. The accelerated convergence cases (ADVANTG/MCNP and MAVRIC) are about 100 times faster with 100 times less particle simulation than those cases run without biasing options (analog MCNP and analog Monaco). The MCNP, ADVANTG/MCNP, Monaco, and MAVRIC calculated dose rates at the package surfaces and at 1 m from the package surfaces for the different source configurations are compared and are found to be in general agreement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Activation Self-Shielding Factors for Common Dosimetry Foils in an ACRR Equivalent Environment

The results of a computational analysis of self-shielding factors are presented. The analysis highlights the total self-shielding, which is a combination of energy and spatial self-shielding, associated with different neutron detection materials. The Monte Carlo N-Particle (MCNP) transport code was used in conjunction with the Evaluated Nuclear Data File (ENDF) and the International Reactor Dosimetry and Fusion Files (IRDFF). This analysis was done with neutron activation analysis in mind, and therefore is modeled and presented in a similar fashion.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗