Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Frequency Domain Detection and Precoding for Massive MIMO With Single Carrier Modulation

Single carrier modulation (SCM) schemes are attractive for uplink (UL) transmissions due to improved power efficiency at the user equipment (UE) transmitter compared with multi-carrier modulation schemes. In a massive MIMO scenario with SCM, the UL detection must mitigate the effects of inter-symbol interference and multiuser interference. This processing is effectively performed in the frequency domain (FD) using a minimum mean squared error (MMSE) detector when the transmission is framed with a cyclic prefix. This paper presents a MMSEbased detector that is compatible with distributed processing in a time-division duplex (TDD) system. The matrix inverses computed for the UL detection are then reused to perform multi-user precoding for the downlink (DL). We find that this scheme yields a tremendous savings in computational complexity compared to commonly used zero-forcing (ZF) precoding without sacrificing any performance. Since MMSE processing introduces a bias to the estimates, we then derive the scalar coefficients necessary to cancel the MMSE bias. The impact of channel estimation errors are analyzed for both the UL and DL cases in conjunction with a power-efficient approach to SCM channel estimation. Moreover, extensive simulations are performed to confirm our theoretical findings.

42 ENGINEERING↗

Fast Cloud Droplet Probe (FCDP) Instrument Handbook

The fast cloud droplet probe (FCDP) is a U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility instrument for measuring the concentration and size of cloud droplets in the diameter size range 1.5-50 μm. It is an open-path instrument mounted on the outside of the aircraft (typically below the wing). When a droplet passes through the sample volume, light from a laser source is scattered, which is used to detect and size the droplet. The sample volume is a focused area of the laser beam that is continuously monitored along the flight path. If a droplet crosses the laser beam but is outside the sample volume, a separate detector will reject the droplet. Only single droplets at a time will be detected and sizes measured over one second have to be averaged to obtain a size distribution. When measuring ice clouds, the FCDP will not yield useful information, since the measurement method, which assumes spherical particles to obtain size and scattering, is very different for ice crystals.

54 ENVIRONMENTAL SCIENCES↗

Detector Characterization for Accurate Monte Carlo Simulation and Neutron Energy-spectrum Unfolding

This report details the characterization of a deuterated scintillation detector for use in neutron spectroscopy via the spectrum unfolding technique. The active volume of the detector consists of a 3-in. diameter by 3 in. depth right circular cylinder that contains 337 cm3 of liquid scintillator EJ-315, deuterated benzene with a D:H ratio of 141:1. A deuterated scintillator is desirable for unfolding fast neutron energy spectra because the backscattering of neutrons from deuterium produces peaks in the pulse height response corresponding to the incident neutron energy. Spectrum unfolding requires the detector’s response to be accurately known for any input neutron energy. The characterization in this report supports using a simulated response matrix calibrated by the measured light output and convolved with the measured resolution to produce a response matrix without bringing the detector to a neutron beam facility for characterization. In particular, characterization measurements were performed that included calibration of the detector’s light output to recoil electrons from gamma sources, calibration of the detector’s resolution to recoil electrons, and calibration of the detector’s light output to recoil protons from a time-tagged neutron source and a monoenergetic 14.1 MeV neutron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radon Photoionization: Project Technical Report

In most low-background physics experiments, radon is a significant and problematic source of background radiation because it is inert and sufficiently long-lived to pervade laboratory spaces. It may be possible to manipulate (and thus mitigate) radon electromagnetically by taking advantage of its relatively low first ionization energy. When considering ambient-temperature gas phases, only iodine is comparable. The other noble gases, and the most important constituents of breathable air (nitrogen and oxygen), all have higher ionization energies; so it may be possible to selectively manipulate radon in a variety of gas streams by ionizing it with an appropriately low-energy source of photons. Radon’s first ionization energy is in the vacuum UV part of the electromagnetic spectrum, which can be produced using a deuterium lamp. In this report, we present our attempts to manipulate radon via UV photoionization in a laboratory setting. This approach has the potential to increase radon removal efficiency from gases and/or to improve the efficiency of radon detectors. Unfortunately, our experiments suggest that either the life-time of a photoionized radon ion (before it re-neutralizes) is too short to be of much practical use and/or that our low-cost UV-photon source was not sufficiently energetic for efficient photoionization of radon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

Refining Fast Simulation Using Machine Learning

A growing reliance on the fast Monte Carlo (FastSim) will accompany the high luminosity and detector granularity expected in Phase 2. FastSim is roughly 10 times faster than equivalent GEANT4-based full simulation (FullSim). However, reduced accuracy of the FastSim affects some analysis variables and collections. To improve its accuracy, FastSim is refined using regression-based neural networks trained with ML. The status of FastSim refinement is presented. The results show improved agreement with the FullSim output and an improvement in correlations among output observables and external parameters.

Güngördü, Acelya Deniz↗

The Readout Electronics of the Mu2e Electromagnetic Calorimeter

The Mu2e electromagnetic calorimeter has been designed to measure ~100 MeV electrons with energy resolution σE/E <10%, time resolution σt < 500ps and position resolution σx < 1cm. The detector is composed of 1348 un-doped CsI crystals coupled to two large area Silicon Photomultipliers (SiPMs). Each SiPM is connected to a Front End Electronics (FEE) chip which hosts the shaping amplifier and the high voltage linear regulator. A group of 20 FEE is controlled by one Mezzanine Board (MB) which transmits the amplified signals to one Digitizer ReAdout Controller board (DiRAC). The DiRAC samples the waveforms at 200 MHz with 12-bit ADCs, packs the data according to the Mu2e custom format and transmits them to the event builder through an optical transceiver. To limit the number of pass-through connectors and the length of the cables, the readout and digitization electronics is located inside the detector cryostat and close to the interaction target. The boards will have to sustain a neutron fluence of about 5x10 10 n/cm 2 @ 1 MeVeq (Si)/y and a Total Ionizing Dose of about 12 krad, while working into a 1T magnetic field and a vacuum of 10 (-4) Torr. This harsh operational environment has made the electronics design challenging and required an extended campaign of tests to select and qualify the employed electronic components. In this paper we report on the board architecture and design, on the qualification of the prototypes, as well as on the results of the first vertical slice test of the Mu2e calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MeV Scale Physics in MicroBooNE

This thesis presents the reconstruction and measurement of low-energy electromagnetic activity with beam neutrino interactions within the MicroBooNE Liquid Argon Time Projection Chamber (LArTPC). LArTPCs have proven to be excellent detectors to measure neutrino interaction cross sections and are being used to perform precision measurements of neutrino oscillation parameters. The work presented in this thesis has demonstrated unprecedentedly low, sub-MeV energy thresholds that have increased sensitivity of LArTPCs to detect neutrino interactions from core collapse supernovae and Muon Decay at Rest (µDAR). In addition, such low thresholds have also increased measurement sensitivity for interactions from Beyond the Standard Model (BSM) candidates such as millicharged particles and nuclear and electron recoils from dark matter candidate particles. On the reconstruction side, this work has established an energy resolution of 6.3% for electromagnetic activity i the 0-5 MeV energy range within the MicroBooNE LArTPC. Additionally this work presents the quantitative analysis of the low-energy activity emanating from G-10 support ribs in MicroBooNE and discusses how such activity could be a problematic source of background for low-energy physics analyses in future neutrino detectors such as the Deep Underground Neutrino Experiment (DUNE).

Bhat, Avinay↗

Portable Programming Model Exploration for LArTPC Simulation in a Heterogeneous Computing Environment: OpenMP vs. SYCL

The evolution of the computing landscape has resulted in the proliferation of diverse hardware architectures, with different flavors of GPUs and other compute accelerators becoming more widely available. To facilitate the efficient use of these architectures in a heterogeneous computing environment, several programming models are available to enable portability and performance across different computing systems, such as Kokkos, SYCL, OpenMP and others. As part of the High Energy Physics Center for Computational Excellence (HEP-CCE) project, we investigate if and how these different programming models may be suitable for experimental HEP workflows through a few representative use cases. One of such use cases is the Liquid Argon Time Projection Chamber (LArTPC) simulation which is essential for LArTPC detector design, validation and data analysis. Following up on our previous investigations of using Kokkos to port LArTPC simulation in the Wire-Cell Toolkit (WCT) to GPUs, we have explored OpenMP and SYCL as potential portable programming models for WCT, with the goal to make diverse computing resources accessible to the LArTPC simulations. In this work, we describe how we utilize relevant features of OpenMP and SYCL for the LArTPC simulation module in WCT. We also show performance benchmark results on multi-core CPUs, NVIDIA and AMD GPUs for both the OpenMP and the SYCL implementations. Comparisons with different compilers will also be given where appropriate.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Trace gas detection with 2-photon, 2-color, cavity ring-down spectroscopy

In one aspect, a method of detecting a trace gas is disclosed. The method includes containing the trace gas in an optical cavity. The method further includes injecting a first laser light from a first laser into the optical cavity causing the trace gas to transition from an energy state lower that a first excited energy state to the first excited energy state, and injecting a second laser light from a second laser into the optical cavity causing the trace gas to transition from the first excited energy state to a second excited energy state. The method includes measuring, by a detector, a first cavity ringdown intensity as a function of time after turning off the second laser with the first laser on, and a second cavity ringdown intensity as a function of time after turning off the second laser with the first laser off.

McCartt, Daniel↗

The ICEBERG Test Stand for DUNE Cold Electronics Development

ICEBERG is a liquid argon time projection chamber at Fermilab for the purpose of testing detector components and software for the Deep Underground Neutrino Experiment (DUNE). The detector features a 1.15m x 1m anode plane following the specifications of the DUNE horizontal drift far detector and a newly installed X-ARAPUCA photodetector. The status of ICEBERG is reported along with analysis of noise, pulser, and cosmic ray data from the ninth run beginning May 2024 with the goal of advising the DUNE collaboration on the optimal wire readout electronics configuration. In addition, development of an absolute energy scale calibration method is currently underway using known sources such as cosmic ray muon Michel electrons at the ~10 MeV scale and $^{39}$Ar decay electrons at the ~100keV scale. Research into AI-based identification of such events at the data acquisition level is introduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PID-Regulated Heating System for PIP-II Reference Line

The Proton Improvement Project-2 centers on building a new superconducting linear particle accelerator (Linac) at Fermilab. At the heart of the accelerator is the reference line, a critical system that defines the ideal path for the particle beam as it passes through magnets, RF cavities, and other beamline elements. Temperature stability is crucial for the reliable operation of RF components, such as mixers and filters. Fluctuations affect key performance parameters like conversion loss, isolation, and linearity. To mitigate any drift caused by ambient temperature changes, a heating plate assembly is utilized to maintain key components at a controlled temperature of 40°C. The system utilizes an aluminum 36”x36”x0.5” heat plate powered by a MOSFET-based control circuit, delivering approximately 460 W of thermal energy through a resistor array. Real-time temperature feedback is provided by a PT100 Resistance Temperature Detector (RTD), which interfaces with a Proportional–Integral–Derivative (PID) control algorithm to maintain closed-loop temperature regulation. The control signal actively modulates the gate voltage of an N channel MOSFET, dynamically adjusting power delivery in response to deviations from the temperature setpoint. Simulations and LTspice models validate the functionality and responsiveness of the circuit under varying conditions. The prototype has successfully demonstrated stable thermal control, paving the way for integration into the PIP-II infrastructure. The final design will feature an expanded resistor array, as well as communication with a PLC for continuous data acquisition and diagnostics. This work directly supports Fermilab’s broader mission by contributing to the stability and reliability of core accelerator systems, enhancing the precision of particle beam delivery for future physics experiments.

Mosher, Alexander [Fermilab]↗

Reconstruction of Six-Dimensional Phase Space

A phase space is a mathematical representation of all possible physical states of a system. Particle beams at Fermilab exist within a six-dimensional (6D) phase space defined by three positional components, (x, y, z) and three momentum components, (px, py, pz). To reconstruct this space implies taking measurement data from detectors and mapping out particle behavior using computational methods. The beam detectors, however, are only able to detect spatial distribution among the events of the beam, therefore being limited to positional data. Also, due to the vast number of events in a particle beam, it is extremely difficult to analyze and differentiate every single one’s behavior. However, with Machine Learning (ML), which can distinguish between patterns and map out particle behavior more efficiently. We first used the particle beam software, G4beamline, to simulate a 10,000-event muon beam, adjusting parameters such as initial momentum magnitude (p¬0) and virtual detector position. Using ten virtual detectors, we analyzed p0 values such that minimum 9,990 events were analyzed by every detector. We then input the data from these beam simulations to a C++ program, that randomly selects 100 events, and creates a 2D histogram based on spatial distribution, detector position, and event intensity. This process is repeated 100 times to create 100 histograms per p0 value. These images were then input to a modified ResNet18 Convolutional Neural Network (CNN) for training, and to predict p0 from some unseen set of histograms. The model was accurate when trained on momentum increments of 5 MeV/c and provided with denser training samples around highly variable test values. These results displayed machine learning being able to accurately predict p0 from being trained on different particle behaviors.

Shirlee, Jermain [Fermilab]↗

Measurement of the longitudinal diffusion of ionization electrons in the MicroBooNE detector

Accurate knowledge of electron transport properties is vital to understanding the information provided by liquid argon time projection chambers (LArTPCs). Ionization electron drift-lifetime, local electric field distortions caused by positive ion accumulation, and electron diffusion can all significantly impact the measured signal waveforms. This paper presents a measurement of the effective longitudinal electron diffusion coefficient, D L , in MicroBooNE at the nominal electric field strength of 273.9 V/cm. Historically, this measurement has been made in LArTPC prototype detectors. This represents the first measurement in a large-scale (85 tonne active volume) LArTPC operating in a neutrino beam. This is the largest dataset ever used for this measurement. Using a sample of ~70,000 through-going cosmic ray muon tracks tagged with MicroBooNE's cosmic ray tagger system, we measure D L = 3.74 +0.28 -0.29 cm 2 /s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reactor neutrino applications and coherent elastic neutrino nucleus scattering

Potential applications of neutrino detection to nuclear security have been discussed since the 1970s. Recent years have seen great progress in detector technologies based on inverse beta decay, with the demonstration of ton-scale surface-level detectors capable of high quality neutrino spectrum measurements. At the same time coherent elastic neutrino nucleus scattering has been experimentally confirmed in 2017 with neutrinos from stopped pion decay and there is a number of experiments aimed at seeing this reaction with reactor neutrinos. Here, the large cross section and threshold-less nature of this reaction make it plausible to consider it for applications to nuclear security and here, we present a first direct comparison of the two reaction modes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a pixelated BaF 2 test bed for timing applications [Slides]

BaF 2 one of the fastest known scintillators, emitting at 195 & 220 nm with sub-nanosecond decay constant. Fast emission only comprises ~13% of total light. The goal is to develop a prototype BaF 2 detector system with a practical form factor and variable geometry, and characterize system performance for various timing applications.

42 ENGINEERING↗

Simulation of energy loss of fractionally charged particles using Geant4

Over the years several rare-event search experiments have shown increasing interest to search for Fractionally Charged Particles (FCPs) within the data acquired in those experiments. This, in turn, has required the need for a framework to calculate accurately the energy loss expected from FCPs as they pass through the detector material. We have developed Monte Carlo methods within Geant4 to simulate for the first time energy loss of FCPs through different physics processes. The program can be used to calculate energy deposition distributions, a major component of any FCP search analysis, as they interact with detector material. We discuss the implementation and validation of the energy loss of FCPs using a typical detector material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

State-of-the-art and evolution of UFSD sensors design at FBK

Over the past few years, there has been growing interest in the development of silicon sensors able to simultaneously measure accurately the time of passage and the position of impinging charged particles. In this contribution, a review of the progresses in the design of UFSD (Ultra-Fast Silicon Detectors) sensors, manufactured at the FBK (Fondazione Bruno Kessler) Foundry, aiming at tracking charged particles in 4 dimensions, is presented. The state-of-the-art UFSD sensors, with excellent timing capability, are planned to be used in both ATLAS and CMS experiments detector upgrade, in order to reduce the background due to the presence of overlapping events in the same bunch crossing. The latest results on sensors characterization including time resolution, radiation resistance and uniformity of the response are here summarized, pointing out the interplay between the design of the gain layer and the UFSD performances. The research is now focusing on the maximization of the sensor fill factor, to be able to reduce the pixel size, exploring the implementation of shallow trenches for the pixel isolation and the development of resistive AC-coupled UFSD sensors. In conclusion, a brief review on research paths tailored for detection of low energy X-rays or for low material budget applications is given.

47 OTHER INSTRUMENTATION↗