Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Development of sensors for ceramic components in advanced propulsion systems: Survey and evaluation of measurement techniques for temperature, strain and heat flux for ceramic components in advanced propulsion systems

The report presents the final results of Tasks 1 and 2, Development of Sensors for Ceramic Components in Advanced Propulsion Systems (NASA program NAS3-25141). During Task 1, an extensive survey was conducted of sensor concepts which have the potential for measuring surface temperature, strain and heat flux on ceramic components for advanced propulsion systems. Each sensor concept was analyzed and evaluated under Task 2; sensor concepts were then recommended for further development. For temperature measurement, both pyrometry and thermographic phosphors are recommended for measurements up to and beyond the melting point of ceramic materials. For lower temperature test programs, the thin-film techniques offer advantages in the installation of temperature sensors. Optical strain measurement techniques are recommended because they offer the possibility of being useful at very high temperature levels. Techniques for the measurement of heat flux are recommended for development based on both a surface mounted sensor and the measurement of the temperature differential across a portion of a ceramic component or metallic substrate.

Atkinson, W. H.↗

WIRE-21 Sensor Irradiation Experiment Ready for HFIR Insertion

The ability to deploy new nuclear fuels for current or future reactor concepts requires a wealth of data regarding fuel performance during normal operation, anticipated operational occurrences, and design-basis accidents. Most of these data have historically been collected during experiments in materials test reactors, ideally with online instrumentation to collect as much data as possible. However, advanced instrumentation could also allow for in situ monitoring of fuel operating conditions during commercial reactor operation to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator understanding of limiting peaking factors. The latter approach would complicate fuel handling, particularly during refueling, unless the instrumentation could be placed inside the fuel rods and transmitted wirelessly to a receiver located outside the fuel’s primary pressure boundary. To this end, Westinghouse Electric Company (WEC) developed wireless sensors based on inductive coupling that can transmit information regarding fuel centerline temperatures and rod internal pressures wirelessly from within a fuel rod to a nearby instrument thimble. After testing these sensors in lower-power university research reactors, the next step is to perform high neutron fluence testing to characterize the performance of these wireless sensors under conditions that are more representative of the intended application—in this case, light-water reactors (LWRs). The removable Be (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) provide the neutron flux, experiment volume, and access to instrument leads required to achieve these sensor testing goals. This report summarizes the design, analysis, and assembly of the Wireless Instrumented RB Experiment 2021 (WIRE-21). This is the most highly instrumented irradiation experiment ever performed in HFIR. The experiment will use seven different sensing techniques to measure temperature, pressure, neutron flux, and neutron fluence during reactor operation. In addition to WEC’s wireless temperature and pressure sensors, WIRE-21 includes an array of thermocouples, self-powered neutron detectors, spatially distributed fiber optic temperature sensors, passive SiC temperature monitors, and flux wires. The design of WIRE-21 and the cabling that was installed in HFIR also provide the infrastructure to enable accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting component temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) that would be expected in the plenum region of LWR fuels, except for the active sensing region of the wireless temperature sensor, which is targeting LWR fuel centerline temperatures (~800–1,100°C). WIRE-21 was successfully assembled, passed all nondestructive examination, and was delivered to HFIR for insertion during upcoming cycle 498 (April 2022).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental and Numerical Characterization of High Heat Fluxes During Transient Blackbody Calibrations

High heat fluxes are encountered in numerous applications, such as hypersonic vehicles in flight, fires, and engines, Calibration of heat flux gages may be performed in a dual cavity cylindrical blackbody resulting in a transient calibration environment. To characterize the transient heat fluxes. experiments were performed on a dual cavity cylindrical blackbody at nominal temperatures varying from 800 C to 1900 C in increments of 100 C. Based on experiments, the optimum heat flux sensor insertion location as measured from the center partition was determined. The pre-insertion steady state axial temperature profile is compared experimentally, numerically, and analytically. The effect of convection in the blackbody cavity during the insertion is calculated and found to be less than 2 per cent. Also, an empirical correlation for predicting the emissivity of the blackbody is included. Detailed transient thermal models have been developed to simulate the heat flux calibration process at two extreme fluxes. The high (1MW/sq m) and relatively low (70 kw/sq m) fluxes are reported in this article. The transient models show the effect of inserting a heat flux gage at room temperature on the thermal equilibrium of the blackbody at 1800 C and 800 C nominal temperatures, respectively. Also, heat flux sensor outputs are derived from computed sensor temperature distributions and compared to experimental results.

Abdelmessih, Amanie N.↗

Extended temperature range rocket injector

A rocket injector is provided with multiple sets of manifolds for supplying propellants to injector elements. Sensors transmit the temperatures of the propellants to a suitable controller which is operably connnected to valves between these manifolds and propellant storage tanks. When cryogenic propellant temperatures are sensed, only a portion of the valves are opened to furnish propellants to some of the manifolds. When lower temperatures are sensed, additional valves are opened to furnish propellants to more of the manifolds.

Schneider, Steven J.↗

Self-Correcting Electronically-Scanned Pressure Sensor

High-data-rate sensor automatically corrects for temperature variations. Multichannel, self-correcting pressure sensor can be used in wind tunnels, aircraft, process controllers and automobiles. Offers data rates approaching 100,000 measurements per second with inaccuracies due to temperature shifts held below 0.25 percent (nominal) of full scale over a temperature span of 55 degrees C.

Gross, C.↗

Fiber Optic Bragg Grating Sensors for Thermographic Detection of Subsurface Anomalies

Conventional thermography with an infrared imager has been shown to be an extremely viable technique for nondestructively detecting subsurface anomalies such as thickness variations due to corrosion. A recently developed technique using fiber optic sensors to measure temperature holds potential for performing similar inspections without requiring an infrared imager. The structure is heated using a heat source such as a quartz lamp with fiber Bragg grating (FBG) sensors at the surface of the structure to detect temperature. Investigated structures include a stainless steel plate with thickness variations simulated by small platelets attached to the back side using thermal grease. A relationship is shown between the FBG sensor thermal response and variations in material thickness. For comparison, finite element modeling was performed and found to agree closely with the fiber optic thermography results. This technique shows potential for applications where FBG sensors are already bonded to structures for Integrated Vehicle Health Monitoring (IVHM) strain measurements and can serve dual-use by also performing thermographic detection of subsurface anomalies.

Allison, Sidney G.↗

Solar total irradiance observations by active cavity radiometers

Investigations have been conducted concerning the development of new cavity pyrheliometer for an absolute measurement of solar irradiance both in preflight testing of spacecraft and in flight experiments to measure the total solar flux. A series of instruments developed as part of this program are electrically self-calibrated cavity pyrheliometers whose mode of operation is characterized by the name Active Cavity Radiometer (ACR). The temperatures of their cavity sensors are servocontrolled, actively maintained at constant temperatures relative to their heat sinks by electrical heating. The solar irradiance is related to the International System of Units by measuring the difference in amount of electrical heating required with the cavity sensor alternately shaded and exposed to the sun. Studies conducted with the ACR are discussed. While variations of a few tenths of a percent in solar total irradiance lasting no more than a week or two have been detected, no long term trends were identified.

Willson, R. C.↗

Recent advances in high temperature instrumentation for hot section applications

Programs to develop research instrumentation for use in turbine engine hot sections are described. These programs were initiated to provide improved measurements capability as support for a multidisciplinary effort to establish technolgy leading to improved hot section durability. Specific measurement systems described here include heat flux sensors, a dynamic gas temperature measuring system, laser anemometry for hot section applications, an optical system for viewing the interior of a combustor during operation, thin film sensors for surface temperature and strain measurements, and high temperature strain measuring systems. The paper describes the state of the development of these sensors and measuring systems and, in some cases, will show examples of measurements made with this instrumentation.The paper covers work done at the NASA Lewis Research Center and at various contract and grant facilities.

Propulsion instrumentation↗

Cold Spray Cobalt Magnetostrictive Electromagnetic Acoustic Transducers for High Temperature Structure Monitoring

The Department of Energy’s Advanced Sensors and Instrumentation program seeks to develop and qualify advanced sensors for the nuclear industry. Reliable high temperature and high radiation sensors for detection and characterization of structural flaws in pipes, vessels, and structurally critical components is a weakness for both conventional light water reactors with coolant T-hot approaching 350oC, and for advanced reactors with T-hot temperatures in excess of 500 to 800oC. Magnetostrictive Electromagnetic Acoustic Transducers using a cold spray cobalt coating have been proposed as a sensor design that can withstand these kinds of temperatures and radiation levels to serve as online sensors to detect flaws before cracks, pits, or erosion/corrosion flaws progress to through-wall failures. This report tests cold spray cobalt as part of a magnetostrictive EMAT for high temperature service. Cobalt is known to have strong magnetostrictive properties however the effect of cold spray application is not well studied. This program was surprised to discover that cold sprayed cobalt exhibited little or no magnetostrictive behavior until it was thermally annealed. Following annealing to 650oC however, cold spray cobalt did exhibit a magnetostrictive response. Work to date prior to this milestone report publication showed that magnetostrictive EMAT was successfully tested to 400oC with an alnico permanent magnet. The program plans to extend testing with an electromagnet to higher temperatures. This follow-on work will be reported under subsequent publications or as a revision to this report.

Glass, Samuel W.↗

Sensor Detects Semiconductor Escaping From Ampoule

Electrical resistance and temperature change upon exposure to semiconductors. Sensor detects breakage of ampoule containing molten semiconductor. Chemical reaction between hot semiconductor material and wire causes step increase in electrical resistance and temperature of wire. Step increase in temperature and resistance of sensor indicates presence of hot GaAs. Sensor used to shut down furnace automatically if ampoule breaks and prevents further release of molton semiconductor, which could quickly breach surrounding thin wall of cartridge, damage furnace, and/or release toxic vapors into surrounding area.

Watring, Dale A.↗

Temperature Dependence of Diffusion and Reaction at a Pd/SiC Contact

Schottky diodes of Palladium/SiC are good candidates for hydrogen and hydrocarbon gas sensors at elevated temperature. The detection sensibility of the diodes has been found heavily temperature dependent. In this work, emphasis has been put on the understanding of changes of physical and chemical properties of the Schottky diodes with variation of temperature. Schottky diodes were made by depositing ultra-thin palladium films onto silicon carbide substrates. The electrical and chemical properties of Pd/SiC Schottky contacts were studied by XPS and AES at different annealing temperatures. No significant change in the Schottky barrier height of the Pd/SiC contact was found in the temperature range of RT-400 C. However, both palladium diffused into SiC and silicon migrated into palladium thin film as well as onto surface were observed at room temperature. The formation of palladium compounds at the Pd/SiC interface was also observed. Both diffusion and reaction at the Pd/SiC interface became significant at 300 C and higher temperature. In addition, silicon oxide was found also at the interface of the Pd/SiC contact at high temperature. In this report, the mechanism of diffusion and reaction at the Pd/SiC interface will be discussed along with experimental approaches.

Shi, D.T.↗

A metal-ceramic coaxial cable with multipoint Fabry-Pérot interferometers for monitoring distributed high temperature

A metal ceramic coaxial cable (MCCC) sensor containing multiple Fabry-Pérot interferometers (FPIs) has been designed, fabricated, and evaluated for measuring distributed high temperatures. The MCCC sensor demonstrated here consists of stainless steel tube and wire conductors, alumina tube insulator, and three pairs of air gap reflectors distributed along the cable. The multipoint sensor operation is realized by the joint time-frequency domain technique, which combines the functions of time-domain reflectometry and frequency division multiplexing to enable the measurement of spatially distributed temperature. The 3-point MCCC-FPI sensor has been demonstrated for distributed temperature measurements between 250 and 550 °C and operability up to 1000 °C. The sensor offers high sensitivity of >0.18 MHz/°C with a measurement resolution of 1 Hz and reasonably small high temperature measurement error range of ±3 °C.

42 ENGINEERING↗

Fiber optics for controls

The challenge of those involved in control-system hardware development is to accommodate an ever-increasing complexity in aircraft control, while limiting the size and weight of the components and improving system reliability. A technology that displays promise towards this end is the area of fiber optics for controls. The primary advantages of employing optical fibers, passive optical sensors, and optically controlled actuators are weight and volume reduction, immunity from electromagnetic effects, superior bandwidth capabilities, and freedom from short circuits and sparking contacts. Since 1975, NASA Lewis has performed in-house, contract, and grant research in fiber optic sensors, high-temperature electro-optic switches, and fly-by-light control-system architecture. Passive optical sensor development is an essential yet challenging area of work and has therefore received much attention during this period. A major effort to develop fly-by-light control-system technology, known as the Fiber-Optic Control System Integration (FOCSI) program, was initiated in 1985 as a cooperative effort between NASA and DOD. Phase 1 of FOCSI, completed in 1986, was aimed at the design of a fiber-optic integrated propulsion/flight control system. Phase 2, yet to be initiated, will provide subcomponent and system development, and a system engine test. In addition to a summary of the benefits of fiber optics, the FOCSI program, sensor advances, and future directions in the NASA Lewis program will be discussed.

Seng, Gary T.↗

Active Thermal Isolation For Hot-Film Anemometers

Local heating compensates for conduction of heat from sensors into modules. Two hot-film sensors stacked on wind-tunnel model. Outer sensor detects changes in boundary-layer flow. Inner sensor provides active thermal isolation between outer sensor and model. Thermal boundary condition controlled at response time of detection hot-film sensor, significantly less than response time of internally heated model. Requires less power to maintain outer hot-film sensor at given temperature, enabling system to respond over greater dynamic range before power limits of instrument reached. Stacked sensors bonded to surface of most wind-tunnel models, even to curved surfaces, and removed after completion of experiments.

Martinson, Scott D.↗

Mars Entry Instrumentation Flight Data and Mars 2020 Entry Environments

On February 18th, 2021, the Mars 2020 entry vehicle delivered the Perseverance rover to the surface of Mars. The entry vehicle carried a set of instrumentation installed on the heatshield and backshell to measure aerodynamic and aerothermal performance, named the Mars Entry, Descent, and Landing Instrumentation 2. This set of instrumentation included pressure transducers, thermocouples, heatflux sensors, and a radiometer, as well as a dedicated sensor support electronics system. All MEDLI2 hardware operated as expected during cruise and entry. MEDLI2 sensors gathered accurate pressure measurements in hypersonic through supersonic regimes to reconstruct vehicle attitude and atmospheric profiles. MEDLI2 on the heatshield sensors indicated that surface temperatures, caused by turbulent heating beginning 70 seconds after entry, remained at or below 1430 °C, while heatshield bondline temperatures rose less than 45 °C. Backshell surface TPS temperatures peaked at 630 °C, which was caused primarily by radiative heating measured by several separate sensors. The MEDLI2 temperature and pressure measurements enabled further detailed characterization of the Mars 2020 entry performance, and the flight dataset will provide a wealth of information for the EDL community and future mission designers.

thermal protection system↗

Mars Entry Instrumentation Flight Data and Mars 2020 Entry Environments

On February 18th, 2021, the Mars 2020 entry vehicle delivered the Perseverance rover to the surface of Mars. The entry vehicle carried a set of instrumentation installed on the heatshield and backshell to measure aerodynamic and aerothermal performance, named the Mars Entry, Descent, and Landing Instrumentation 2. This set of instrumentation included pressure transducers, thermocouples, heatflux sensors, and a radiometer, as well as a dedicated sensor support electronics system. All MEDLI2 hardware operated as expected during cruise and entry. MEDLI2 sensors gathered accurate pressure measurements in hypersonic through supersonic regimes to reconstruct vehicle attitude and atmospheric profiles. MEDLI2 on the heatshield sensors indicated that surface temperatures, caused by turbulent heating beginning 70 seconds after entry, remained at or below 1430 °C, while heatshield bondline temperatures rose less than 45 °C. Backshell surface TPS temperatures peaked at 630 °C, which was caused primarily by radiative heating measured by several separate sensors. The MEDLI2 temperature and pressure measurements enabled further detailed characterization of the Mars 2020 entry performance, and the flight dataset will provide a wealth of information for the EDL community and future mission designers.

thermal protection systems↗

The Use of Thermal Cameras for Pedestrian Detection

Visible-range camera sensors have been widely used for pedestrian detection. However, most of the methods, which employ visible-range color cameras, do not perform well under low-light and no-light conditions, e.g. during night time. Since the working principle of thermal camera sensors is mainly based on temperature and not light, they have been employed for person detection to overcome the drawbacks of visible-range sensors under these conditions. Every object gives off thermal energy, which is captured by a thermal camera sensor. When an object becomes hotter, it emits more thermal energy, and is therefore captured as much brighter or vice versa. Yet, compared to visible-range cameras, there are many additional challenges that need to be addressed when detecting pedestrians from thermal camera images. These challenges include bright hot objects close to humans, similar pixel values in an image due to weather conditions, or objects that block thermal cameras such as concrete or glass. Glass acts like a mirror for infrared radiation and reflects whatever is in front of the camera. Thus, novel methods are still required to accomplish pedestrian detection task from thermal camera images. To contribute to these efforts, we propose a new method and a modified object detection network incorporating saliency maps of thermal camera images. The features obtained from thermal images and their corresponding saliency maps are combined to obtain richer representations of pedestrian regions, and better detection performance. We perform extensive evaluations on five different datasets to compare the performance of the proposed approach with two baselines. Moreover, we evaluate and compare the transferability of these approaches by doing leave-one-out cross validation across different datasets. Furthermore, the results show that the proposed approach outperforms the baselines, and has better transferability properties across different thermal image datasets.

47 OTHER INSTRUMENTATION↗