Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “technical evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

CSP Systems Analysis 2022-2024 (Final Technical Report)

The CSP Systems Analysis project estimates the current market cost of CSP subsystems and technologies for use by the DOE Program and within NREL analysis tools. The project addresses upgrades to NREL's System Advisor Model (SAM) related to CSP, as well as development of new modules within SAM to expand the types of CSP systems that can be simulated and new tools for evaluating CSP subsystem performance or optimizing CSP system layouts, for example, SolarPILOT and SolTrace. The project evaluates the potential cost and performance of new CSP-relevant technologies and generally includes assessment of CSP technologies in support of the DOE subprogram. A primary goal of the CSP System Analysis project is to provide timely and accurate cost data to the DOE to assess the current state of CSP technologies as well as predict performance and cost for pre-commercial and emerging technologies that may impact the industry. Prior work in this task has produced technology cost reports and roadmaps for DOE and highlighted promising research paths that could reduce overall CSP cost, such as the supercritical CO2 power cycle and molten-salt trough systems. CSP Systems Analysis produces modeling tools to evaluate the performance of CSP systems, subsystems, or components, and journal articles, conference papers, technical reports and databases to disseminate information to the CSP industry. CSP technology costs are estimated and tracked using these tools as well as analysis of literature and industry sources. The CSP modeling tools and NREL analysis results are used by researchers; government, financial, and industry analysts; and other CSP stakeholders. The purpose of this final technical report is to summarize the key accomplishments of the past three years of this project. The project was divided into seven separate tasks, and in what follows, we describe the background, objectives, key accomplishments, and path forward for each task within the project, with one section of this report summarizing each task.

14 SOLAR ENERGY↗

Evaluation of a Dedicated Balloon Catheter for Infrapopliteal Difficult Calcified Lesions in Diabetic Patients With Critical Limb Ischemia

The purpose of this study was to assess the technical performance and immediate procedural outcome of a new balloon catheter in the treatment of calcified lesions in infrapopliteal arterial disease. Sixty-one patients (81 vessels) with infrapopliteal arterial disease were evaluated. Seventy-four of the 81 treated vessels had total occlusions. The ReeKross 18 peripheral transluminal angioplasty catheter (ClearStream, Wexford, Ireland) is an 0.018-inch guidewire system with 4F sheath compatibility and a rigid shaft intended for enhanced pushability. Only technical procedural outcomes were recorded. In 37 of 61 patients (50 infrapopliteal severely stenosed or occluded vessels), an attempt with a standard balloon was made before the ReeKross 18 was used. In 24 patients, the ReeKross 18 was used as the primary catheter in 23 cases involving crural arteries and in 8 cases involving the foot. The ReeKross 18 crossed the lesion in 55 of 59 (93.2%) patients and 72 of 77 (94.5%) vessels, respectively. Postdilatation results for the 51 patients (64 target lesions) in whom ReeKross 18 balloon dilation was achieved showed <30% residual stenosis in all but 4 patients (5 lesions). Of the patients treated with the ReeKross 18 as the primary catheter, the technical success rate (no adjunctive treatment/stent) was obtained in 20 of 24 (83.3%) patients (27 of 31 [87.1%] target lesions). In the treatment of difficult calcified lesions, the choice of a high-pushability angioplasty catheter, such as the ReeKross 18, warrants consideration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Dynamic Stress in The Reactor Core Barrel Due to the Pressure Pulsations

This article presents vibrations analysis of the reactor core barrel caused by pressure pulsations induced by the main coolant pump. For this purpose, the calculations of the pressure distribution in the annulus between the core barrel and the reactor pressure vessel, bounded above by a separating ring were performed. Using transfer matrix method is obtained the solution of two-dimensional problem of pressure pulsations in the annulus between reactor core barrel and reactor vessel. The calculation results are compared with the pulsation pressure measurements made at commissioning unit 2 of the South Ukraine Nuclear Power Station. The distribution of pressure over the height of core barrel was obtained, which makes possible to estimate its strength for variant deformation of the core barrel as a beam, and in the case of deformation of the core barrel as a shell. The calculation results are used to assess the reliability of core barrel pre-load, which clamps the core barrel flange in place at the top, at full power operating. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Aftertreatment protocols for catalyst characterization and performance evaluation: low-temperature oxidation, storage, three-way, and NH3-SCR catalyst test protocols

A set of standardized and realistic aftertreatment catalyst test protocols have been developed by the Advanced Combustion and Emission Control Technical Team in support of the U.S.DRIVE Partnership. The protocols are intended to accelerate the pace of aftertreatment catalyst innovation by enabling the accurate evaluation and comparison of aftertreatment catalyst performance data from various testing and research facilities to maximize the impact of discovery-phase research occurring across the nation. The protocols address a need identified by the Partnership’s industry partners for consistent and accurate metrics for aftertreatment catalyst evaluation and comparison. The protocols consist of a set of standardized requirements and test procedures that sufficiently capture the performance capability of a catalyst technology in a manner that is adaptable in various laboratories. The protocols provide a detailed description of the necessary reactor system, the steps for achieving a desired aged state of the catalyst, all necessary sample pretreatment to be performed prior to testing, and realistic test conditions for evaluating performance. This article details four low-temperature catalyst test protocols applicable to (1) oxidation catalysts, (2) passive storage (and release) catalysts, (3) three-way catalysts, and (4) NH3-SCR catalysts. The catalyst test protocol descriptions are presented in five (5) sections: protocol general guidelines and the four individual catalyst test protocol descriptions. The general guidelines plus the individual protocol description forms the complete low-temperature catalyst test protocol for the application.

Emission control, Three-way catalyst, oxidation, S↗

Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 {+-} 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 {+-} 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 {+-} 0.42 Gy) were <2 Gy without relevant dependence on procedure complexity. Local DRL values for kerma area product (KAP), fluoroscopy time (FT), and number of frames (N{sub FR}) were 269 Gy cm{sup 2}, 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1-102.7, p < 0.05) and N{sub FR} overexposures (OR 10.8, 95 % CI 1.1-109.5, p < 0.05). Type I aortic arch decreased the risk of FT overexposure (OR 0.4, 95 % CI 0.1-0.9, p = 0.042), and stenosis {>=} 90 % increased the risk of N{sub FR} overexposure (OR 2.8, 95 % CI 1.1-7.4, p = 0.040). At multivariable analysis, stenosis {>=} 90 % (OR 2.8, 95 % CI 1.1-7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1-109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rock Melt Borehole Sealing System, Final Technical Report for SBIR Phase I Grant No. DE-SC0011888

Purpose of Research Deep borehole disposal is one option that has received attention in recent years as a possible strategy for long-term disposal of the tens of thousands of tons of spent nuclear fuel. The feasibility of the deep borehole option relies upon designing and constructing an effective seal within the borehole to ensure that the waste package does not communicate with the shallow subsurface biosphere through the borehole itself. Some of the uncertainty associated with the long-term suitability of the deep borehole option is related to (1) the degradation of traditional sealing materials over time and (2) the inability of traditional sealing methods to adequately seal a Disturbed Rock Zone surrounding the borehole. One possible system to address these concerns consists of encapsulating the waste in a melt generated from either the waste itself or a plug above the waste. This current project expanded on previous work to further advance the deep borehole disposal concept. Research Objectives & Findings The overarching objective of the study was to evaluate the feasibility of constructing a downhole heater that is capable of meeting the technical and logistical requirements to melt rock. This ultimate objective was accomplished by two primary approaches. The first approach was to define the heater requirements and conceptually design a system that is capable of melting rock. The second approach was to determine the feasibility of conducting an in situ, field-scale melting experiment to validate the suitability of the rock melt seal concept. The evaluation and conceptual design of the heater system resulted in the following primary findings: • Borehole wall temperatures capable of producing a partial melt are achievable under most expected thermal conductivities with a 12-kilowatt heater. • Commercially available components have been identified that meet the requirements of the heater system, including resistive elements that are capable of providing the required heat generation, container materials that can withstand the anticipated temperatures, and a system capable of providing power to the heater. Evaluating the feasibility of performing field-scale experiments resulted in the following major findings: • The Sanford Underground Research Facility (SURF) has been identified as a host site for field testing of prototype heaters. The technical and logistical requirements for performing the rock melt tests can be met by using or expanding the existing infrastructure at SURF with on-site personnel and contractors. • In situ hydraulic conductivity test using packers can test the effectiveness of the rock melt seal, while a mine back performed from a lower level can further evaluate the recrystallized melt. • Preliminary costing indicates that a field-scale melting experiment at SURF is feasible within a Phase II Small Business Innovation Research budget while allowing sufficient budget for refining the heater design, coordinating the test program, and interpreting the results. Application of Research The rock melt sealing concept has the potential to reduce uncertainty associated with the long-term storage of nuclear waste. Preliminary efforts of this study defined the requirements of a downhole heater system capable of melting rock and indicated that developing such a system is feasible using available technology. The next logical step is designing and manufacturing prototype heaters. Concurrent with prototype development is coordinating robust field-scale experiments that are capable of validating the design for marketing to potential users.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Meta-Level Framework for Evaluating Resilience in Net-Zero Carbon Power Systems with Extreme Weather Events in the United States

Important changes are underway in the U.S. power industry in the way that electricity is sourced, transported, and utilized. Disruption from extreme weather events and cybersecurity events is bringing new scrutiny to power-system resilience. Recognizing the complex social and technical aspects that are involved, this article provides a meta-level framework for coherently evaluating and making decisions about power-system resilience. It does so by examining net-zero carbon strategies with quantitative, qualitative, and integrative dimensions across discrete location-specific systems and timescales. The generalizable framework is designed with a flexibility and logic that allows for refinement to accompany stakeholder review processes and highly localized decision-making. To highlight the framework’s applicability across multiple timescales, processes, and types of knowledge, power system outages are reviewed for extreme weather events, including 2021 and 2011 winter storms that impacted Texas, the 2017 Hurricane Maria that affected Puerto Rico, and a heatwave/wildfire event in California in August 2020. By design, the meta-level framework enables utility decision-makers, regulators, insurers, and communities to analyze and track levels of resilience safeguards for a given system. Future directions to advance an integrated science of resilience in net-zero power systems and the use of this framework are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Solid Oxide Fuel Cell - Multi-Physics and GUI

SOFC-MP is a simulation tool developed at PNNL to evaluate the tightly coupled multi-physical phenomena in SOFCs. The purpose of the tool is to allow SOFC manufacturers to numerically test changes in planar stack design to meet DOE technical targets. The SOFC-MP 2D module is designed for computational efficiency to enable rapid engineering evaluations for operation of tall symmetric stacks. It can quickly compute distributions for the current density, voltage, temperature, and species composition in tall stacks with co-flow or counter-flow orientations. The 3D module computes distributions in entire 3D domain and handles all planner configurations: co-flow, counter-flow, and cross-flow. The detailed data from 3D simulation can be used as input for structural analysis. SOFC-MP GUI integrates both 2D and 3D modules, and it provides user friendly pre-processing and post-processing capabilities.

Lai, Kevin↗

Regulatory aspects of oncology drug safety evaluation: Past practice, current issues, and the challenge of new drugs

The drug development of new anti-cancer agents is streamlined in response to the urgency of bringing effective drugs to market for patients with limited life expectancy. FDA's regulation of oncology drugs has evolved from the practices set forth in Arnold Lehman's seminal work published in the 1950s through the current drafting of a new International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) safety guidance for anti-cancer drug nonclinical evaluations. The ICH combines the efforts of the regulatory authorities of Europe, Japan, and the United States and the pharmaceutical industry from these three regions to streamline the scientific and technical aspects of drug development. The recent development of new oncology drug classes with novel mechanisms of action has improved survival rates for some cancers but also brings new challenges for safety evaluation. Here we present the legacy of Lehman and colleagues in the context of past and present oncology drug development practices and focus on some of the current issues at the center of an evolving harmonization process that will generate a new safety guidance for oncology drugs, ICH S9. The purpose of this new guidance will be to facilitate oncology drug development on a global scale by standardizing regional safety requirements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiofrequency Ablation Assisted by Real-Time Virtual Sonography and CT for Hepatocellular Carcinoma Undetectable by Conventional Sonography

Real-time virtual sonography (RVS) is a diagnostic imaging support system, which provides the same cross-sectional multiplanar reconstruction images as ultrasound images on the same monitor screen in real time. The purpose of this study was to evaluate radiofrequency ablation (RFA) assisted by RVS and CT for hepatocellular carcinoma (HCC) undetectable with conventional sonography. Subjects were 20 patients with 20 HCC nodules not detected by conventional sonography but detectable by CT or MRI. All patients had hepatitis C-induced liver cirrhosis; there were 13 males and 7 females aged 55-81 years (mean, 69.3 years). RFA was performed in the CT room, and the tumor was punctured with the assistance of RVS. CT was performed immediately after puncture, and ablation was performed after confirming that the needle had been inserted into the tumor precisely. The mean number of punctures and success rates of the first puncture were evaluated. Treatment effects were evaluated with dynamic CT every 3 months after RFA. RFA was technically feasible and local tumor control was achieved in all patients. The mean number of punctures was 1.1, and the success rate of the first puncture was 90.0%. This method enabled safe ablation without complications. The mean follow-up period was 13.5 month (range, 9-18 months). No local recurrence was observed at the follow-up points. In conclusion, RFA assisted by RVS and CT is a safe and efficacious method of treatment for HCC undetectable by conventional sonography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emborrhoid: A New Concept for the Treatment of Hemorrhoids with Arterial Embolization: The First 14 Cases

PurposeThe ‘emborrhoid’ technique consists of the embolization of the hemorrhoidal arteries. The endovascular arterial occlusion is performed using coils placed in the terminal branches of the superior rectal arteries. The emborrhoid technique has been modeled after elective transanal Doppler-guided hemorrhoidal artery ligation which has been shown to be effective in hemorrhoidal disease. We report the first 14 cases of our experience with emborrhoid technique.Materials and MethodsFourteen patients with disabling chronic rectal bleeding were treated using the emborrhoid technique (3 women, 11 men). The stage of the hemorrhoidal disease was II (10 patients), III (3), and IV (1). This treatment was decided by a multidisciplinary team (proctologist, visceral surgeon, and radiologist). Seven patients underwent previous proctological surgery. Ten patients had coagulation disorders (anticoagulants or cirrhosis). Superior rectal arteries were embolized with pushable microcoils (0.018).ResultsTechnical success of the embolization procedure was 100 %. Clinical success at 1 month was 72 % (10/14). Of the 4 patients who experienced rebleeding, two underwent additional embolization of the posterior rectal arteries with success. No pain or ischemic complications were observed in 13 patients. One patient experienced a temporary painful and edematous, perianal reaction.ConclusionOur case studies suggest that coil embolization of the superior rectal arteries is technically feasible, safe and well tolerated. Additional studies are needed to evaluate the efficacy of this new ‘emborrhoid’ technique in the management of hemorrhoidal disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SANS quantification of bound water in water-soluble polymers across multiple concentration regimes

Contrast-variation small-angle neutron scattering (CV-SANS) is a widely used technique for quantifying hydration water in soft matter systems, but it is predominantly applied in the dilute regime or for systems with a well-defined structure factor. Here, CV-SANS was used to quantify the number of hydration water molecules associating with three water-soluble polymers with different critical solution temperatures and types of water–solute interactions in dilute, semidilute, and concentrated solution through the exploration of novel methods of data fitting and analysis. Multiple SANS fitting workflows with varying levels of model assumptions were evaluated and compared to give insight into SANS model selection. These fitting pathways ranged from general, model-free algorithms to more standard form and structure factor fitting. In addition, Monte Carlo bootstrapping was evaluated as a method to estimate parameter uncertainty through simulation of technical replicates. The most robust fitting workflow for dilute solutions was found to be form factor fitting without CV-SANS ( i.e. polymer in 100% D 2 O). For semidilute and concentrated solutions, while the model-free approach can be mathematically defined for CV-SANS data, the addition of a structure factor imposes physical constraints on the optimization problem, suggesting that the optimal fitting pathway should include appropriate form and structure factor models. The measured hydration numbers were consistent with the number of tightly bound water molecules associated with each monomer unit, and the concentration dependence of the hydration number was largely governed by the chemistry-specific interactions between water and polymer. Polymers with weaker water–polymer interactions ( i.e. those with fewer hydration water molecules) were found to have more bound water at higher concentrations than those with stronger water–polymer interactions due to the increase in the number of forced water–polymer contacts in the concentrated system. This SANS-based method to count hydration water molecules can be applied to polymers in any concentration regime, which will lead to improved understanding of water–polymer interactions and their impact on materials design.

36 MATERIALS SCIENCE↗

Joint Estimation of Behind-the-Meter Solar Generation in a Community

Distribution grid planning, control, and optimization require accurate estimation of solar photovoltaic (PV) generation and electric load in the system. Most of the small residential solar PV systems are installed behind-the-meter making only the net load readings available to the utilities. This paper presents an unsupervised framework for joint disaggregation of the net load readings of a group of customers into the solar PV generation and electric load. Our algorithm synergistically combines a physical PV system performance model for individual solar PV generation estimation with a statistical model for joint load estimation. The electric loads for a group of customers are estimated jointly by a mixed hidden Markov model (MHMM) which enables modeling the general load consumption behavior present in all customers while acknowledging the individual differences. At the same time, the model can capture the change in load patterns over a time period by the hidden Markov states. The proposed algorithm is also capable of estimating the key technical parameters of the solar PV systems. Our proposed method is evaluated using the net load, electric load, and solar PV generation data gathered from residential customers located in Austin, Texas. Testing results show that our proposed method reduces the mean squared error of state-of-the-art net-load disaggregation algorithms by 67%.

behind-the-meter solar generation↗

Nuclear Resonance Fluorescence to Measure Plutonium Mass in Spent Nuclear Fuel

The Next Generation Safeguard Initiative (NGSI) of the U.S Department of Energy is supporting a multi-lab/university collaboration to quantify the plutonium (Pu) mass in spent nuclear fuel (SNF) assemblies and to detect the diversion of pins with non-destructive assay (NDA) methods. The following 14 NDA techniques are being studied: Delayed Neutrons, Differential Die-Away, Differential Die-Away Self-Interrogation, Lead Slowing Down Spectrometer, Neutron Multiplicity, Passive Neutron Albedo Reactivity, Total Neutron (Gross Neutron), X-Ray Fluorescence, {sup 252}Cf Interrogation with Prompt Neutron Detection, Delayed Gamma, Nuclear Resonance Fluorescence, Passive Prompt Gamma, Self-integration Neutron Resonance Densitometry, and Neutron Resonance Transmission Analysis. Understanding and maturity of the techniques vary greatly, ranging from decades old, well-understood methods to new approaches. Nuclear Resonance Fluorescence (NRF) is a technique that had not previously been studied for SNF assay or similar applications. Since NRF generates isotope-specific signals, the promise and appeal of the technique lies in its potential to directly measure the amount of a specific isotope in an SNF assay target. The objectives of this study were to design and model suitable NRF measurement methods, to quantify capabilities and corresponding instrumentation requirements, and to evaluate prospects and the potential of NRF for SNF assay. The main challenge of the technique is to achieve the sensitivity and precision, i.e., to accumulate sufficient counting statistics, required for quantifying the mass of Pu isotopes in SNF assemblies. Systematic errors, considered a lesser problem for a direct measurement and only briefly discussed in this report, need to be evaluated for specific instrument designs in the future. Also, since the technical capability of using NRF to measure Pu in SNF has not been established, this report does not directly address issues such as cost, size, development time, nor concerns related to the use of Pu in measurement systems. This report discusses basic NRF measurement concepts, i.e., backscatter and transmission methods, and photon source and {gamma}-ray detector options in Section 2. An analytical model for calculating NRF signal strengths is presented in Section 3 together with enhancements to the MCNPX code and descriptions of modeling techniques that were drawn upon in the following sections. Making extensive use of the model and MCNPX simulations, the capabilities of the backscatter and transmission methods based on bremsstrahlung or quasi-monoenergetic photon sources were analyzed as described in Sections 4 and 5. A recent transmission experiment is reported on in Appendix A. While this experiment was not directly part of this project, its results provide an important reference point for our analytical estimates and MCNPX simulations. Used fuel radioactivity calculations, the enhancements to the MCNPX code, and details of the MCNPX simulations are documented in the other appendices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2014 Water Power Program Peer Review Report

The Water Power Peer Review Meeting was held February 24-28, 2014 in Arlington, VA. Principle investigators from the Energy Department National Laboratories, academic, and industry representatives presented the progress of their DOE-funded research. This report documents the formal, rigorous evaluation process and findings of nine independent reviewers who examined the technical, scientific, and business results of 96 projects of the Water Power Program, as well as the productivity and management effectiveness of the Water Power Program itself.

13 HYDRO ENERGY↗

2014 Wind Program Peer Review Report

The Wind Program Peer Review Meeting was held March 24-28, 2014 in Arlington, VA. Principle investigators from the Energy Department, National Laboratories, academic, and industry representatives presented the progress of their DOE-funded research. This report documents the formal, rigorous evaluation process and findings of nine independent reviewers who examined the technical, scientific, and business results of Wind Program funded projects, as well as the productivity and management effectiveness of the Wind Program itself.

17 WIND ENERGY↗

R-Matrix Codes for Charged-particle Induced Reactionsin the Resolved Resonance Region

A Consultant’s Meeting was held at the IAEA Headquarters, from 5 to 7 December 2016, to discuss the status of R-matrix codes currently used in calculations of charged-particle induced reaction cross sections at low energies. The meeting was a follow-up to the R-matrix Codes meeting held in December 2015, and served the purpose of monitoring progress in: the development of a translation code to enable exchange of input/output parameters between the various codes in different formats, fitting procedures and treatment of uncertainties, the evaluation methodology, and finally dissemination. The details of the presentations and technical discussions, as well as additional actions that were proposed to achieve all the goals of the meeting are summarized in this report.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Report on Hydrogen Isotope Permeability/Hermeticity of SiC-based Cladding

The continuous SiC fiber-reinforced SiC matrix ceramic composites have been perceived as one of the leading candidate materials for accident tolerant fuel cladding in light water reactors. Potential loss of the fission products containment due to penetrating cracking has been identified as one of the most critical technical issues for SiC-based nuclear fuel cladding. As such, evaluation of the hermeticity of SiC/SiC composite cladding subject to ligh water reactor (LWR) relevant environment is critically important. In last two years, we have established the capability to measure the gas permeation flux through tubular samples and reported preliminary results of the hermeticity of unirradiated SiC/SiC composite tubes and one neutron irradiated Chemical Vapor Deposition (CVD) SiC tube. In this study, a permeation testing station was employed to measure the deuterium permeation of as-fabricated and coated SiC/SiC composite tubes following high heat flux neutron irradiation. The results indicate that CVD SiC tubes survived both the high and low heat flux neutron irradiations. SiC/SiC composite tubes with and without coating following high heat flux neutron irradiation lost gas tightness. Coating on SiC/SiC composite tubes helped to reduce the deuterium permeation flux compared to the uncoated samples. Better coating and/or improved architectural design and manufacturing quality is needed to ensure the hermeticity of SiC/SiC composite tubes. A more robust understanding of the correlation between applied gas pressure and measured leak rate is needed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗