Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectral elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Unlocking the Sun's Secrets: Laboratory Insights into the Sun's Outer Atmosphere

The Sun’s corona, its outermost and hottest atmospheric layer, emits brightly in the extreme ultraviolet (EUV) and X-rays. This emission comes from atoms that have been highly ionized by the high temperature, forming a plasma of atomic ions and free electrons. By studying this light, scientists learn about the complex and dynamic drivers of solar activity. Many past, current, and future solar observatories focus on measuring EUV spectra from the Fe IX ion, as this ion provides powerful diagnostics for solar physics. Using Fe IX spectra, solar physicists can measure the plasma temperature, density, elemental abundances, and flow velocities in the corona. However, atomic data uncertainties concerning spectral line identification and plasma density diagnostics are a major problem for the accurate interpretation of these spectra.

74 ATOMIC AND MOLECULAR PHYSICS↗

A luminous peculiar type IA supernova SN 2011HR: More like SN 1991T or SN 2007if?

Photometric and spectroscopic observations of a slowly declining, luminous Type Ia supernova (SN Ia) SN 2011hr in the starburst galaxy NGC 2691 are presented. SN 2011hr is found to peak at M{sub B} = −19.84±0.40 mag, with a postmaximum decline rate Δm{sub 15}(B) = 0.92 ± 0.03 mag. From the maximum-light bolometric luminosity, L = (2.30±0.90)×10{sup 43} erg s{sup −1}, we estimate the mass of synthesized {sup 56}Ni in SN 2011hr to be M({sup 56}Ni) = 1.11±0.43 M{sub ⊙}. SN 2011hr appears more luminous than SN 1991T at around maximum light, and the absorption features from its intermediate-mass elements (IMEs) are noticeably weaker than those of the latter at similar phases. Spectral modeling suggests that SN 2011hr has IMEs of ∼0.07 M{sub ⊙} in the outer ejecta, which is much lower than the typical value of normal SNe Ia (i.e., 0.3–0.4 M{sub ⊙}) and is also lower than the value of SN 1991T (i.e., ∼0.18 M{sub ⊙}). These results indicate that SN 2011hr may arise from a Chandrasekhar-mass white dwarf progenitor that experienced a more efficient burning process in the explosion. Nevertheless, it is still possible that SN 2011hr may serve as a transitional object connecting the SN 1991T-like SNe Ia with a superluminous subclass like SN 2007if given that the latter also shows very weak IMEs at all phases.

79 ASTRONOMY AND ASTROPHYSICS↗

DRAGraces: A Pipeline for the GRACES High-resolution Spectrograph at Gemini

This paper describes the software Data Reduction and Analysis for GRACES (DRAGraces), which is a pipeline reducing spectra from Gemini Remote Access to the CFHT ESPaDOnS Spectrograph (GRACES) at the Gemini North Telescope. The code is written in the IDL language. It is designed to find all the GRACES frames in a given directory, automatically determine the list of bias, flat, arc, and science frames, and perform the whole reduction and extraction within a few minutes. We compare the output from DRAGraces with that of the Open source Pipeline for ESPaDOnS Reduction and Analysis (OPERA), a pipeline developed at the Canada–France–Hawaii Telescope (CFHT) that also can extract GRACES spectra. Both pipelines were developed completely independently, yet they give very similar extracted spectra. They both have their advantages and disadvantages. For instance, DRAGraces is more straightforward and easy to use and is less likely to be derailed by a parameter that needs to be tweaked, while OPERA offers a more careful extraction that can be significantly superior when the highest resolution is required and when the signal-to-noise ratio is low. One should compare both before deciding which one to use for their science. Yet, both pipelines deliver a fairly comparable resolution power (R ~ 52.8k and 36.6k for DRAGraces and R ~ 58k and 40k for OPERA in high- and low-resolution spectral modes, respectively), wavelength solution, and signal-to-noise ratio per resolution element.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultraviolet photometry from the orbiting Astronomical Observatory. IX - The ultraviolet behavior of U Ophiuchi

Seven simultaneous light curves of U Oph have been obtained which cover a wavelength range from the blue part of the optical spectrum to just longward of L alpha in the ultraviolet. An analysis of these curves has been carried out to determine the spectral variation of limb and gravity darkening as well as to determine geometrical elements for the system. We conclude that (1) U Oph is gravity darkened to the extent expected from von Zeipel's law, (2) limb darkening increases toward shorter wavelengths, and (3) at the shortest wavelengths observed, the two stars are limb-darkened totally.

Source record↗

The Corralitos Observatory program for the detection of lunar transient phenomena

This is a final report on the establishment, observing procedures, and observational results of a survey program for the detection of lunar transient phenomena (LTP's) by electro-optical image conversion means. For survey, a unique detection system with an image orthicon was used as the primary element in conjunction with a 24-in. f/20 Cassegrainian telescope. Observations in three spectral ranges, with 6,466 man-hours of observing, were actually performed during the period from October 27, 1965, to April 26, 1972. Within this entire period, no color or feature change within the detection capabilities of the instrumentation was observed, either independently or in follow up of amateur LTP reports, with the exception of one general bluing and several localized bluings (probably ascribable to the effects of the terrestrial atmosphere) that were observed solely by the Corralitos system. A table is presented indicating amateur and professional reports of LTP's and the results of efforts to confirm these reports through the Corralitos system.

Hynek, J. A.↗

Spectroscopic imaging of the thermosphere from the Space Shuttle

The design features, performance characteristics, and intended missions for the Imaging Spectrometric Observatory scheduled to fly on the first Spacelab Shuttle mission in 1983 are described. The instrument comprises an array of five imaging spectrometers covering the spectral range 300-1200 A. The spectrometers operate simultaneously, using CCDs as collector elements. Resolution on the first flight will be limited to 3 A, with coverage to containing the dynamic range from nocturnal signals to the bright earth. A minicomputer in the Spacelab will permit crewmember interaction with the measurements, while data will be telemetered in real-time to a ground station. Initial mission objectives include observations of dayglow, nightglow, and twilightglow over the full wavelength range capability.

Torr, M. R.↗

Thematic mapper study of Alaskan ophiolites

The combinations of Thematic Mapper (TM) bands that best distinguish basalts of the Brooks Range ophiolites were determined. Geochemical analyses, including major, trace, and rare earth elements (REE), are being done in order to study the significance of TM spectral variations that were observed within some of the sampled rock units. An image of the topography of the western Brooks Range and Colville Basin was constructed. Elevation data for the rest of Northern Alaska are being acquired to expand the area covered by the topography image. Two balanced cross sections (one along the eastern margin, the other along the western margin of the Brooks Range) are being constructed, using the techniques of fault-bend and fault-propagation folding. These are being used to obtain regional shortening estimates for the Brooks Range in an attempt to constrain tectonic models for the evolution of Northern Alaska. The TM data are being used to confirm reconnaissance maps and to obtain structural data where no maps exist. Along with the TM data, digital topography, seismic reflection profiles, and magnetic and gravity surveys are examined to better understand the evolution of the Colville Basin, north of the Brooks Range.

Bird, J. M.↗

Spectral methods for CFD

One of the objectives of these notes is to provide a basic introduction to spectral methods with a particular emphasis on applications to computational fluid dynamics. Another objective is to summarize some of the most important developments in spectral methods in the last two years. The fundamentals of spectral methods for simple problems will be covered in depth, and the essential elements of several fluid dynamical applications will be sketched.

Zang, Thomas A.↗

FTIR Spectroscopic Characterization Of II-VI Semiconductors

Combination of commercial Fourier-transform infrared (FTIR) spectrometer with computer and special-purpose software constitutes highly automated facility for acquisition and processing of infrared transmission or reflection spectral image data. Intended principally to acquire transmission spectra of some compounds of elements in groups II and VI of periodic table. System used to characterize specimens of II/VI alloy semiconductors grown by directional solidification and quenching. Transmission-edge maps helpful in studies of flows, gradients of temperature, and coefficients of diffusion in solidifying melts. Data acquired by system include optical characteristics, and they both verify and complement data obtained by such other techniques as measurements of density and x-ray-dispersion analysis.

Perry, G. L. E.↗

Spectroscopy Made Easy: A New Tool for Fitting Observations with Synthetic Spectra

We describe a new software package that may be used to determine stellar and atomic parameters by matching observed spectra with synthetic spectra generated from parameterized atmospheres. A nonlinear least squares algorithm is used to solve for any subset of allowed parameters, which include atomic data (log gf and van der Waals damping constants), model atmosphere specifications (T(sub eff, log g), elemental abundances, and radial, turbulent, and rotational velocities. LTE synthesis software handles discontiguous spectral intervals and complex atomic blends. As a demonstration, we fit 26 Fe I lines in the NSO Solar Atlas (Kurucz et al.), determining various solar and atomic parameters.

Valenti, J. A.↗

Evidence for Coordination and Redox Changes of Iron in Shocked Feldspar from Synchrotron MicroXANES

Shock modification of feldspar has been documented and experimentally reproduced in many studies since the recognition of maskelynite in Shergotty. Experimentally shocked feldspar samples have been well studied using chemical and crystallographic techniques. The crystallographic, site-specific characterization of major and minor elements is less well documented. We present early x-ray absorption (XAS) spectral data for a suite of albitite samples that were experimentally shocked at pressures between 17 and 50 Gpa.

Delaney, J. S.↗

Accurate VUV Laboratory Measurements of Fe III Transitions for Astrophysical Applications

We report preliminary measurements of Fe III spectra in the 1150 to 2500 A wavelength interval. Spectra have been recorded with an iron-neon Penning discharge lamp (PDL) between 1600 and 2500 A at Imperial College (IC) using high resolution Fourier (FT) transform spectroscopy. These FT spectrometer measurements were extended beyond 1600 A to 1150 A using high-resolution grating spectroscopy at the National Institute of Standards and Technology (NIST). These recorded spectra represent the first radiometrically calibrated measurements of a doubly-ionized iron-group element spectrum combining the techniques of vacuum ultraviolet FT and grating spectroscopy. The spectral range of the new laboratory measurements corresponds to recent HST/STIS observations of sharp-lined B stars and of Eta Carinae. The new improved atomic data can be applied to abundance studies and diagnostics of astrophysical plasmas.

Blackwell-Whitehead, R. J.↗

Spectral Analysis of PG 1034+001, the Exciting Star of Hewett 1

PG 1034+001 is an extremely hot, helium-rich DO-type star that excites the planetary nebula Hewett 1 and large parts of the surrounding interstellar medium. We present preliminary results of an ongoing spectral analysis by means of non-LTE model atmospheres that consider most elements from hydrogen to nickel. This analysis is based on high-resolution ultraviolet (FUSE, IUE) and optical (VLT/UVES, KECK) data. The results are compared with those of PG 1034+001's spectroscopic twin, the DO star PG 0038+ 199. Keywords. stars: abundances, stars: AGB and post-AGB, stars: atmospheres, stars: evolution, stars: individual (PG 1034+001, PG 0038+ 199), planetary nebulae: individual (Hewett 1)

Kruk, J. W.↗

Tropospheric Emissions: Monitoring of Pollution Overview

TEMPO is now well into its implementation phase, having passed both its Key Decision Point C and the Critical Design Review (CDR) for the instrument. The CDR for the ground systems will occur in March 2016 and the CDR for the Mission component at a later date, after the host spacecraft has been selected. TEMPO is on schedule to measure atmospheric pollution for greater North America from space using ultraviolet and visible spectroscopy. TEMPO measures from Mexico City to the Canadian oil sands, and from the Atlantic to the Pacific, hourly and at high spatial resolution. TEMPO provides a tropospheric measurement suite that includes the key elements of tropospheric air pollution chemistry. Measurements are from geostationary (GEO) orbit, to capture the inherent high variability in the diurnal cycle of emissions and chemistry. The small product spatial footprint resolves pollution sources at sub-urban scale. Together, this temporal and spatial resolution improves emission inventories, monitors population exposure, and enables effective emission-control strategies. TEMPO takes advantage of a GEO host spacecraft to provide a modest cost mission that measures the spectra required to retrieve O3, NO2, SO2, H2CO, C2H2O2, H2O, aerosols, cloud parameters, and UVB radiation. TEMPO thus measures the major elements, directly or by proxy, in the tropospheric O3 chemistry cycle. Multi-spectral observations provide sensitivity to O3 in the lowermost troposphere, substantially reducing uncertainty in air quality predictions by 50 percent. TEMPO quantifies and tracks the evolution of aerosol loading. It provides near-real-time air quality products that will be made widely, publicly available. TEMPO provides much of the atmospheric measurement capability recommended for GEO-CAPE in the 2007 National Research Council Decadal Survey, Earth Science and Applications from Space: National Imperatives for the Next Decade and Beyond. Instruments from Europe (Sentinel 4) and Asia (GEMS) will form parts of a global GEO constellation for pollution monitoring later this decade, with a major focus on intercontinental pollution transport. TEMPO will launch at a prime time to be a component of this constellation.

Chance, Kelly↗

Tropospheric Emissions: Monitoring of Pollution (TEMPO)

TEMPO (Tropospheric Emissions: Monitoring of Pollution) was selected in 2012 by NASA as the first Earth Venture Instrument, for launch between 2018 and 2021. It will measure atmospheric pollution for greater North America from space using ultraviolet and visible spectroscopy. TEMPO observes from Mexico City, Cuba, and the Bahamas to the Canadian oil sands, and from the Atlantic to the Pacific, hourly and at high spatial resolution (approximately 2.1 kilometers N/S by 4.4 kilometers E/W at 36.5 degrees N, 100 degrees W). TEMPO provides a tropospheric measurement suite that includes the key elements of tropospheric air pollution chemistry, as well as contributing to carbon cycle knowledge. Measurements are made hourly from geostationary (GEO) orbit, to capture the high variability present in the diurnal cycle of emissions and chemistry that are unobservable from current low-Earth orbit (LEO) satellites that measure once per day. The small product spatial footprint resolves pollution sources at sub-urban scale. Together, this temporal and spatial resolution improves emission inventories, monitors population exposure, and enables effective emission-control strategies. TEMPO takes advantage of a commercial GEO host spacecraft to provide a modest cost mission that measures the spectra required to retrieve ozone (O3), nitrogen dioxide (NO2), sulfur dioxide (SO2), formaldehyde (H2CO), glyoxal (C2H2O2), bromine monoxide (BrO), IO (iodine monoxide),water vapor, aerosols, cloud parameters, ultraviolet radiation, and foliage properties. TEMPO thus measures the major elements, directly or by proxy, in the tropospheric O3 chemistry cycle. Multi-spectral observations provide sensitivity to O3 in the lowermost troposphere, substantially reducing uncertainty in air quality predictions. TEMPO quantifies and tracks the evolution of aerosol loading. It provides these near-real-time air quality products that will be made publicly available. TEMPO will launch at a prime time to be the North American component of the global geostationary constellation of pollution monitoring together with the European Sentinel-4 (S4) and Korean Geostationary Environment Monitoring Spectrometer (GEMS) instruments.

tropospheric measurement suite↗

Photometric Properties of Quiet Sun Observed With the DKIST and HINODE

The variability of irradiance is primarily influenced by surface magnetism, such as sunspots, faculae, and network structures. Each of these features contributes differently to the overall variability. However, the impact of small magnetic elements, which are commonly observed in high resolution images of the solar photosphere but remain unresolved in full-disk images used for irradiance modeling, is still a topic of debate. Understanding the influence of these small magnetic elements to the overall brightness, particularly in quiet regions, is fundamental to understanding irradiance fluctuations over decadal and longer temporal scales. We investigate the brightness of small-size magnetic elements using very high spatial resolution spectro-polarimetric observations acquired at different spectral ranges with the National Science Foundations Daniel K. Inouye Solar Telescope (DKIST) and with HINODE/SOT. Our results are compared to 3D MHD Small Solar Dynamo simulations obtained with the MURaM code.

SMD↗

The X-ray Integral Field Unit (X-IFU) for Athena

Athena is designed to implement the Hot and Energetic Universe science theme selected by the European Space Agency for the second large mission of its Cosmic Vision program. The Athena science payload consists of a large aperture high angular resolution X-ray optics (2 m2 at 1 keV) and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager. The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), oering 2.5 eV spectral resolution, with approximately 5" pixels, over a field of view of 5' in diameter. In this paper, we present the X-IFU detector and readout electronics principles, some elements of the current design for the focal plane assembly and the cooling chain. We describe the current performance estimates, in terms of spectral resolution, effective area, particle background rejection and count rate capability. Finally, we emphasize on the technology developments necessary to meet the demanding requirements of the X-IFU, both for the sensor, readout electronics and cooling chain.

X-ray↗

Could Microplasma Ionization and Ultrahigh Mass Resolution Alleviate Chemical Separations for Elemental and Isotopic Analysis?

At the extremes, all analytical spectrometric measurements are limited by the resolution of the spectrometer system. Spectral overlaps, isobars in the case of mass spectrometry, can lead to the implementation of complex and time-consuming chemical separations to alleviate those interferences. In the area of elemental/isotopic mass spectrometry, use of sector-field instruments can provide a mass resolution of ~10,000, but still necessitate chemical separations. Described here is the coupling of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to ultra-high resolution Orbitrap mass analyzer systems to yield mass resolution values ranging from 70k to 1M. Resolution of this order, with commensurate improvements in precision and accuracy, holds the promise to affect elemental/isotopic determinations without the need for chemical separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗