Embedded Fiber Bragg Grating (FBG) Sensors Fabricated by Ultrasonic Additive Manufacturing for High-Frequency Dynamic Strain Measurements

This article demonstrates high-frequency dynamic strain measurements using fiber Bragg grating (FBG) sensors embedded in metal parts. Using an ultrasonic additive manufacturing (UAM) process, FBGs inscribed in polyimide coated optical fibers were embedded in aluminum parts. An electromagnetic shaker was used to exert dynamic events on the embedded FBG sensors with frequencies from 1 to 10 kHz. The high-speed interrogation of FBG sensors was accomplished using a tunable vertical-cavity surface-emitting laser (VCSEL) and a high-speed interrogation system sampling at 120 kHz. The strain response measured by the FBG sensors was compared with real-time measurements using a laser velocimeter. A finite-element analysis (FEA) was performed to simulate responses to both static strain and high-frequency dynamic strain. In conclusion, results show that strains as small as 2.5$με$ can be resolved at frequencies up to 10 kHz.

36 MATERIALS SCIENCE↗

Resilient Reinforcement in Secure State Estimation against Sensor Attacks with a priori Information

This paper deals with the state estimation problem in the presence of malicious sensor attacks. Unlike the existing work, in this paper, we address the problem with a priori information of the state to be estimated. Specifically, we address three prior knowledge: the sparsity information, (alpha, n_0)-sparsity information, and side information, and in each scenario, we show that the state can be reconstructed even if more sensors are compromised. This implies that the prior information reinforces the system resilience against sensor attacks. Then, an estimator under sensor attacks considering the information is developed and, under a certain condition, the estimator can be relaxed into a tractable convex optimization problem. Further, we extend this analysis to systems in presence of measurement noises, and it is shown that the prior information reduces the state-estimation error caused by the noise. Here, the numerical simulations in a diffusion process finally illustrate the reinforcement and error-reduction results with the information.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optical fiber evanescent wave adsorption sensors for high-temperature gas sensing in advanced coal-fired power plants

Modern advanced energy systems such as coal-fired power plants, gasifiers, or similar infrastructure present some of the most challenging harsh environments for sensors. The power industry would benefit from new, ultra-high temperature devices capable of surviving in hot and corrosive environments for embedded sensing at the highest value locations. For these applications, we are currently exploring optical fiber evanescent wave absorption spectroscopy (EWAS) based sensors consisting of high temperature core materials integrated with novel high temperature gas sensitive cladding materials. Mathematical simulations can be used to assist in sensor development efforts, and we describe a simulation code that assumes a single thick cladding layer with gas sensitive optical constants. Recent work has demonstrated that Au nanoparticle-incorporated metal oxides show a potentially useful response for high temperature optical gas sensing applications through the sensitivity of the localized surface plasmon resonance absorption peak to ambient atmospheric conditions. Hence, the simulation code has been applied to understand how such a response can be exploited in an optical fiber based EWAS sensor configuration. We demonstrate that interrogation can be used to optimize the sensing response in such materials.

01 COAL, LIGNITE, AND PEAT↗

A Gating Charge Transfer Center in Voltage Sensors

Voltage sensors regulate the conformations of voltage-dependent ion channels and enzymes. Their nearly switchlike response as a function of membrane voltage comes from the movement of positively charged amino acids, arginine or lysine, across the membrane field. We used mutations with natural and unnatural amino acids, electrophysiological recordings, and x-ray crystallography to identify a charge transfer center in voltage sensors that facilitates this movement. This center consists of a rigid cyclic 'cap' and two negatively charged amino acids to interact with a positive charge. Specific mutations induce a preference for lysine relative to arginine. By placing lysine at specific locations, the voltage sensor can be stabilized in different conformations, which enables a dissection of voltage sensor movements and their relation to ion channel opening.

59 BASIC BIOLOGICAL SCIENCES↗

Real-Time Tracking of Carbon Dioxide Concentration Using an Optical Microsphere Resonator Sensor

Whispering gallery mode resonator sensors are nondisruptive optical sensors that can detect and monitor perturbations in a gaseous environment. Through its resonant properties of peak wavelength, amplitude, and quality factor (Q factor), changes in concentration can be quantified within seconds and monitored over days with great stability. In addition, the small footprint, low cost, and high sensitivity are ideal properties for a disposable sensor that can be utilized in extreme environments. Further, the large Q factor of the resonant cavity enables long interaction lengths and amplifies the effect of small changes in the background refractive index, which is detectable in picometer shifts of the resonance wavelength. However, this measurement is susceptible to changes in other environmental factors such as temperature, pressure, and humidity, which manifest on the picometer wavelength scale, reinforcing the need to decouple the variables. In this work, we compare the spectral response of different diameter resonators to carbon dioxide, nitrogen, and its mixtures, observing the spectral shifting and broadening of the cavity resonance near 1550 nm. In addition, the effect of environmental temperature on spectral shifting due to the thermo-optic effect is characterized and quantified. Lastly, the gas concentrations are changed in real time to showcase the tracking and recovery capabilities of the resonator sensor.

47 OTHER INSTRUMENTATION↗

Geomechanical modeling of distributed fiber-optic sensor measurements

Fiber-optic-based distributed acoustic sensors (DAS) are a new technology that can be deployed in a well and are continuously interrogated during operations. These sensors calculate the strain (or strain rate) at all points along the fiber and have been used extensively to monitor hydraulic stimulations. The data from these sensors indicate that they are sensitive to high-frequency signals associated with microseismicity and low-frequency signals associated with fracture growth. We have developed a set of idealized models to simulate these signals and to identify interpretation methods that may be used to estimate fracture location, geometry, and extent. We use a multiphysics code that includes rock physics, fluid flow, and elastic-wave propagation to generate synthetic DAS measurements from a set of simple models that mimic hydraulic fracturing. We then relate the signals observed in the synthetic DAS to specific features in the model such as fracture height, width, and aperture. Our results demonstrate that the synthetic DAS measurements may be used to determine field DAS measurements and to optimize the design of future sensor deployments for sensitivity to fracture attributes.

03 NATURAL GAS↗

Optical resonant sensors: a method to reduce the effect of thermal drift

The use of a whispering gallery mode (WGM) resonator with an ultrahigh quality factor Q is promising in highly sensitive, label-free, lab-on-a-chip sensor applications. We investigated a novel method of using the differential frequency of TE and TM modes to reduce the thermal noise baseline, which commonly limits the sensitivity of WGM sensors. We studied the temperature dependence of WGM based sensors and experimentally demonstrated the reduction of temperature fluctuation and thus a significant improvement in the practical sensor detection limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

One-dimensional single-mode fiber-optic displacement sensors for submillimeter measurements

We demonstrate the working principle of a one-dimensional intensity-based fiber-optic displacement sensor. The sensor consists of one receiving fiber, which is moved laterally in the optical field emitted by an emitting fiber. It is shown numerically that the sensor response is highly linear (nonlinearity error of 0.1 to 2%) for a wide range of travel (2.24 to 860 {mu}m). The sensor response is also simulated experimentally using a highly precise robot, the results of which correspond very closely to numerical ones. Linearity, travel, and sensitivity are experimentally determined for different gaps between the emitting and the receiving fibers (10 {mu}m to 10 mm). A design chart that includes the nonlinearity error (0.5% to 2%), the travel (2.78 to 860 {mu}m), the sensitivity (0.032 to 0.37 dB/{mu}m), and the gap distance (1 to 10 mm) is finally proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical stress sensor based on electro-optic compensation for photoelastic birefringence in a single crystal

An optical stress sensor is proposed by using a single crystal with both electro-optic and photoelastic effects. Different from previous crystal-based stress sensors, the proposed sensor is based on electro-optic compensation for stress-induced birefringence and does not need an additional quarter-wave plate or modulator, because the stress-sensing element is simultaneously used as an electro-optic compensator. Candidate sensing materials include electro-optic crystals of the 3 m symmetry group and all glass with large Kerr coefficients. A primary experiment has demonstrated that the stress-induced birefringence in lithium niobate crystal can be compensated by its electro-optic birefringence. The proposed stress sensor is compact and low cost, and it is possible to achieve closed-loop stress measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensor Fish Characterization of Fish Passage Conditions through John Day Dam Spillbay 20 with a Modified Flow Deflector

Fish passage conditions over a modified deflector in Spillbay 20 at John Day Dam were evaluated by Pacific Northwest National Laboratory for the U.S. Army Corps of Engineers (USACE), Portland District, using Sensor Fish devices. The objectives of the study were to describe and compare passage exposure conditions at two spill discharges, 2.4 and 4.0 thousand cubic feet per second (kcfs), identifying potential fish injury regions within the routes, and to evaluate a low-tailwater condition at the 2.4-kcfs discharge. The study was performed in April 2010 concurrent with HI-Z balloon-tag studies by Normandeau Associates, Inc. Sensor Fish data were analyzed to estimate 1) exposure conditions, particularly exposure to severe collision and shear events; 2) differences in passage conditions between treatments; and 3) relationships to live-fish injury and mortality data estimates. Nearly all Sensor Fish significant events were classified as collisions; the most severe occurred at the gate, on the spillbay chute, or at the deflector transition. Collisions in the gate region were observed only during the 2.4-kcfs discharge, when the tainter gate was open 1.2 ft. One shear event was observed during the evaluation, occurring at the deflector transition during passage at the 2.4-kcfs discharge at low tailwater. Flow quality, computed using the Sensor Fish turbulence index, was best for passage at the low-flow low-tailwater condition as well. The worst flow quality was observed for the 4.0-kcfs test condition. Contrasting the passage exposure conditions, the 2.4-kcfs low-tailwater treatment would be most deleterious to fish survival and well-being.

54 ENVIRONMENTAL SCIENCES↗

PVT-NG Sensor Final Report

This document is a final report for the polyvinyl toluene (PVT) neutron-gamma (PVT-NG) project, which was sponsored by the Domestic Nuclear Detection Office (DNDO). The PVT-NG sensor uses PVT detectors for both gamma and neutron detection. The sensor exhibits excellent spectral resolution and gain stabilization, which are features that are beneficial for detection of both gamma-ray and neutron sources. In fact, the ability to perform isotope identification based on spectra that were measured by the PVT-NG sensor was demonstrated. As described in a previous report, the neutron sensitivity of the first version of the prototype was about 25% less than the DNDO requirement of 2.5 cps/ng for bare 252 Cf. This document describes design modifications that were expected to improve the neutron sensitivity by about 50% relative to the PVT-NG prototype. However, the project was terminated before execution of the design modifications after portal vendors demonstrated other technologies that enable neutron detection without the use of 3 He. Nevertheless, the PVT-NG sensor development demonstrated several performance goals that may be useful in future portal designs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multipurpose Acoustic Sensor for Downhole Fluid Monitoring

The projects objectives and purpose are to: (1) development a multipurpose acoustic sensor for downhole fluid monitoring in Enhanced Geothermal Systems (EGS) reservoirs over typical ranges of pressures and temperatures and demonstrate its capabilities and performance for different EGS systems; (2) determine in real-time and in a single sensor package several parameters - temperature, pressure, fluid flow and fluid properties; (3) needed in nearly every phase of an EGS project, including Testing of Injection and Production Wells, Reservoir Validation, Inter-well Connectivity, Reservoir Scale Up and Reservoir Sustainability. (4) Current sensors are limited to operating at lower temperatures, but the need is for logging at high temperatures. The present project deals with the development of a novel acoustic-based sensor that can work at temperatures up to 374 °C, in inhospitable environments.

15 GEOTHERMAL ENERGY↗

Use of Occupancy Sensors in LED Parking Lot and Garage Applications: Early Experiences

Occupancy sensor systems are gaining traction as an effective technological approach to reducing energy use in exterior commercial lighting applications. Done correctly, occupancy sensors can substantially enhance the savings from an already efficient lighting system. However, this technology is confronted by several potential challenges and pitfalls that can leave a significant amount of the prospective savings on the table. This report describes anecdotal experiences from field installations of occupancy sensor controlled light-emitting diode (LED) lighting at two parking structures and two parking lots. The relative levels of success at these installations reflect a marked range of potential outcomes: from an additional 76% in energy savings to virtually no additional savings. Several issues that influenced savings were encountered in these early stage installations and are detailed in the report. Ultimately, care must be taken in the design, selection, and commissioning of a sensor-controlled lighting installation, else the only guaranteed result may be its cost.

LED lighting↗

Wireless Sensor Network for Improving the Energy Efficiency of Data Centers

Data centers occupy less than 2% of the federally owned portfolio under the jurisdiction, custody or control of the U.S. General Services Administration (GSA), but represent nearly 5% of the agency’s overall energy budget. Assuming that energy use in GSA’s data centers tracks with industry averages, GSA can anticipate that data center energy use will grow at an annual rate of 15%, a doubling of energy use every five years.1 In fact, energy is the single largest operating expense for most data centers. Improving the energy performance of data center systems supports progress toward meeting federally mandated greenhouse gas emission-­reduction goals, while reducing operating and energy costs and allowing for greater flexibility in future expansion by eliminating the need to provide additional power and cooling. Studies sponsored by the U.S. Department of Energy (DOE) and the U.S. Environmental Protection Agency (EPA) have shown that energy use can be reduced by 25% through implementation of best practices and commercially available technologies. The present study evaluated the effectiveness of a strategy to cost- effectively improve the efficiency of data center cooling, which is the single largest non-­IT load. The technology that was evaluated consists of a network of wireless sensors—including branch circuit power monitors, temperature sensors, humidity sensors, and pressure sensors, along with an integrated software product to help analyze the collected data. The technology itself does not save energy; however, its information collection and analysis features enable users to understand operating conditions and identify problem areas. In addition, data obtained by this technology can be input into assessment tools that can identify additional best practice measures. Energy savings result from the implementation of the best practices. The study was conducted to validate the premise that providing data center operators with detailed, real- time measurement of environmental parameters and power consumption enables them to establish baseline performance, discover areas of sub-optimal performance, and identify concrete opportunities for improvement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bayesian Optimal Sensor Augmentation Via Estimated Mutual Information

We consider the problem of designing a sensor network to most efficiently locate the source of a seismic event. The left panel of Figure 1 shows 982 possible sensor locations in a region of interest. The objective is to infer the unknown location of an earthquake, indicated by the gold dot for illustration purposes. Assume that three sensors have already been placed for data collection. Travel times of the P-wave from the source to the three sensors are observed and used to infer the unknown source location via a Bayesian statistical model described subsequently. The right panel of Figure 1 shows samples from the resulting posterior distribution for source location along with a posterior estimate of this location.

47 OTHER INSTRUMENTATION↗

Doped Lanthanum Chromite-refractory Based Composites Sensors for High Temperature Monitoring in Harsh Environments Systems

In order to test and monitor the operational stability and conditions of various energy, and manufacturing systems and their components, development of accurate sensors capable of operating at temperatures in excess of 1000 °C in various environments for long durations is required. In addition, many of these harsh-environment systems do not permit sensors to be directly inserted, so these sensors need to be embedded into thermal protective materials. In this work were developed high-temperature embedded thermocouples composed of various doped lanthanum chromites-refractory based composites synthesized by a mixed-oxide route and directly embedded into a Al2O3 based refractory. The electrical properties were specifically manipulated by altering the level of percolation of the conductive phase within the refractory constituent. Chemical stability of sensors was determined by phase development analysis by X-ray diffraction and X-ray photoelectron spectroscopy; Seebeck coefficients were determined by thermoelectric voltages measurements at temperature up to 1400 oC.

Perovskite LaCrO3, High-temperature conductivity, ↗

Embedded High-Temperature Sensors: Enhancing Thermoelectrical Performance with Refractory Composites Gradient Layers

To monitor the stability of various energy and manufacturing systems, sensors capable of operating at temperatures exceeding 1000 °C in diverse environments for extended durations are essential. However, under harsh conditions, degradation of sensing materials is a concern that can be controlled by embedding the sensors into refractory oxides. Doped-LaCrO3 based composites are excellent candidates for high-temperature sensing applications due to their good thermoelectrical properties. However, chemical reactivity between the conductive phase and the refractory oxides can decrease the performance of the sensors. In this work, it was devised gradient-type protective layers safeguarding conductive phases within embedded thermocouples, which were fabricated and characterized by X-Ray Diffraction for phase development analysis, Scanning Electron Microscopy and Energy-dispersive X-ray spectroscopy for microstructure and cationic interdiffusion kinetics, long-term thermoelectric testing was completed up to 1400 °C. The enhanced performance of these novel sensors addresses a critical limitation, rendering them viable for long-term high-temperature applications.

20 FOSSIL-FUELED POWER PLANTS↗