Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scanning mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

High-speed adaptive contact-mode atomic force microscopy imaging with near-minimum-force

In this paper, an adaptive contact-mode imaging approach is proposed to replace the traditional contact-mode imaging by addressing the major concerns in both the speed and the force exerted to the sample. The speed of the traditional contact-mode imaging is largely limited by the need to maintain precision tracking of the sample topography over the entire imaged sample surface, while large image distortion and excessive probe-sample interaction force occur during high-speed imaging. In this work, first, the image distortion caused by the topography tracking error is accounted for in the topography quantification. Second, the quantified sample topography is utilized in a gradient-based optimization method to adjust the cantilever deflection set-point for each scanline closely around the minimal level needed for maintaining stable probe-sample contact, and a data-driven iterative feedforward control that utilizes a prediction of the next-line topography is integrated to the topography feeedback loop to enhance the sample topography tracking. The proposed approach is demonstrated and evaluated through imaging a calibration sample of square pitches at both high speeds (e.g., scan rate of 75 Hz and 130 Hz) and large sizes (e.g., scan size of 30 μm and 80 μm). The experimental results show that compared to the traditional constant-force contact-mode imaging, the imaging speed can be increased by over 30 folds (with the scanning speed at 13 mm/s), and the probe-sample interaction force can be reduced by more than 15% while maintaining the same image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-channel transport experiments at Alcator C-Mod and comparison with gyrokinetic simulations

Multi-channel transport experiments have been conducted in auxiliary heated (Ion Cyclotron Range of Frequencies) L-mode plasmas at Alcator C-Mod [Marmar and Alcator C-Mod Group, Fusion Sci. Technol. 51(3), 3261 (2007)]. These plasmas provide good diagnostic coverage for measurements of kinetic profiles, impurity transport, and turbulence (electron temperature and density fluctuations). In the experiments, a steady sawtoothing L-mode plasma with 1.2 MW of on-axis RF heating is established and density is scanned by 20%. Measured rotation profiles change from peaked to hollow in shape as density is increased, but electron density and impurity profiles remain peaked. Ion or electron heat fluxes from the two plasmas are the same. The experimental results are compared directly to nonlinear gyrokinetic theory using synthetic diagnostics and the code GYRO [Candy and Waltz, J. Comput. Phys. 186, 545 (2003)]. We find good agreement with experimental ion heat flux, impurity particle transport, and trends in the fluctuation level ratio (T(tilde sign){sub e}/T{sub e})/(ñ{sub e}/n{sub e}), but underprediction of electron heat flux. We find that changes in momentum transport (rotation profiles changing from peaked to hollow) do not correlate with changes in particle transport, and also do not correlate with changes in linear mode dominance, e.g., Ion Temperature Gradient versus Trapped Electron Mode. The new C-Mod results suggest that the drives for momentum transport differ from drives for heat and particle transport. The experimental results are inconsistent with present quasilinear models, and the strong sensitivity of core rotation to density remains unexplained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal IR imaging system using a self-scanned HgCdTe/CCD detector array

It is likely that future high resolution earth observation imaging systems will utilize self-scanned IR detectors. In an initial step toward this goal, an IR imaging system operating in the 10 to 12 micron spectral region has been developed. This system uses a 9-element HgCdTe/CCD linear array operating in the photoconductive mode, nine pre-amplifiers and a silicon CCD multiplexer integrated into a focal plane assembly. Opto-mechanical techniques are used to scan the scene and images are produced in real time. The imaging performance of this system is described and measurements of noise, responsivity, specific detectivity, and detector sensitivity profiles are presented. The requirements for more advanced detector arrays for use in future NASA remote sensing missions are also discussed.

Husain-Abidi, A. S.↗

On Utilization of NEXRAD Scan Strategy Information to Infer Discrepancies Associated With Radar and Rain Gauge Surface Volumetric Rainfall Accumulations

To evaluate the Tropical Rainfall Measuring Mission (TRMM) monthly Ground Validation (GV) rain map, 42 quality controlled tipping bucket rain gauge data (1 minute interpolated rain rates) were utilized. We have compared the gauge data to the surface volumetric rainfall accumulation of NEXRAD reflectivity field, (converting to rain rates using a 0.5 dB resolution smooth Z-R table). The comparison was carried out from data collected at Melbourne, Florida during the month of July 98. GV operational level 3 (L3 monthly) accumulation algorithm was used to obtain surface volumetric accumulations for the radar. The gauge records were accumulated using the 1 minute interpolated rain rates while the radar Volume Scan (VOS) intervals remain less than or equal to 75 minutes. The correlation coefficient for the radar and gauge totals for the monthly time-scale remain at 0.93, however, a large difference was noted between the gauge and radar derived rain accumulation when the radar data interval is either 9 minute, or 10 minute. This difference in radar and gauge accumulation is being explained in terms of the radar scan strategy information. The discrepancy in terms of the Volume Coverage Pattern (VCP) of the NEXRAD is being reported where VCP mode is ascertained using the radar tilt angle information. Hourly radar and gauge accumulations have been computed using the present operational L3 method supplemented with a threshold period of +/- 5 minutes (based on a sensitivity analysis). These radar and gauge accumulations are subsequently improved using a radar hourly scan weighting factor (taking ratio of the radar scan frequency within a time bin to the 7436 total radar scans for the month). This GV procedure is further being improved by introducing a spatial smoothing method to yield reasonable bulk radar to gauge ratio for the hourly and daily scales.

Roy, Biswadev↗

Making maps of cosmic microwave background polarization for B-mode studies: the POLARBEAR example

Analysis of cosmic microwave background (CMB) datasets typically requires some filtering of the raw time-ordered data. For instance, in the context of ground-based observations, filtering is frequently used to minimize the impact of low frequency noise, atmospheric contributions and/or scan synchronous signals on the resulting maps. In this paper, we have explicitly constructed a general filtering operator, which can unambiguously remove any set of unwanted modes in the data, and then amend the map-making procedure in order to incorporate and correct for it. We show that such an approach is mathematically equivalent to the solution of a problem in which the sky signal and unwanted modes are estimated simultaneously and the latter are marginalized over. We investigated the conditions under which this amended map-making procedure can render an unbiased estimate of the sky signal in realistic circumstances. We then discuss the potential implications of these observations on the choice of map-making and power spectrum estimation approaches in the context of B-mode polarization studies. Specifically, we have studied the effects of time-domain filtering on the noise correlation structure in the map domain, as well as impact it may haveon the performance of the popular pseudo-spectrum estimators. We conclude that although maps produced by the proposed estimators arguably provide the most faithful representation of the sky possible given the data, they may not straightforwardly lead to the best constraints on the power spectra of the underlying sky signal and special care may need to be taken to ensure this is the case. By contrast, simplified map-makers which do not explicitly correct for time-domain filtering, but leave it to subsequent steps in the data analysis, may perform equally well and be easier and faster to implement. We focused on polarization-sensitive measurements targeting the B-mode component of the CMB signal and apply the proposed methods to realistic simulations based on characteristics of an actual CMB polarization experiment, POLARBEAR. Finally, our analysis and conclusions are however more generally applicable.

79 ASTRONOMY AND ASTROPHYSICS↗

Correlated whistler and electron plasma oscillation bursts detected on ISEE-3

The ISEE-3 plasma wave instrument detects associated bursts of electron plasma oscillations and whistler mode waves at an average rate of event one every two days. The plasma wave measurements give the electron number density, and simultaneously measured E and B amplitudes are used to deduce an index of refraction consistent with whistler mode propagation for the measured number density and magnetic field. Burst durations are a few minutes, with some trains of bursts lasting up to an hour. Individual spectral scans (two per second) reveal that the whistler and plasma wave amplitude-time profiles differ within a burst. Peak plasma wave amplitudes are near one mV/m, and the peak whistler mode energy density exceeds that of the plasma oscillations by about a factor 100. The frequency of the whistler mode wave observed in one well diagnosed event agrees with the predictions of the heat flux whistler instability theory. The associated plasma wave instability probably requires a bump-on-tail feature in the heat flux electron component, possibly due to impulsive heating elsewhere on the field-line connecting to ISEE-3.

Kennel, C. F.↗

Thermal imaging of plasma with a phased array antenna in QUEST

A thermal imaging system to measure plasma Electron Bernstein Emission (EBE) emanating from the mode conversion region in overdense plasma is discussed. Unlike conventional ECE/EBE imaging, this diagnostics does not employ any active mechanical scanning mirrors or focusing optics to scan for the emission cones in plasma. Instead, a standard 3 × 3 waveguide array antenna is used as a passive receiver to collect emission from plasma and imaging reconstruction is done by accurate measurements of phase and intensity of these signals by heterodyne detection technique. A broadband noise source simulating the EBE, is installed near the expected mode conversion region and its position is successfully reconstructed using phase array technique which is done in post processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PFPO plasma scenarios for exploration of long pulse operation in ITER

Long Pulse Scenarios (LPS) in ITER foreseen during the Pre-Fusion Power Operation (PFPO) phase of the ITER Research Plan (IRP) are assessed using 1.5D transport simulations within the ASTRA framework. Such assessment is required to predict the operational space for LPS operation in PFPO, as well as to evaluate which physics processes for LPS operation during Fusion Power Operation (FPO) could be studied during PFPO. An important aspect in the development of LPSs in PFPO is to minimize lifetime consumption of the Central Solenoid (CS) for these scenarios. The maximum pulse length achievable for LPSs in PFPO with no consumption of CS lifetime (currents in CS coils $⩽$30 kA per turn) has been assessed for a range of heating schemes and heating mixes, confinement regimes (L-mode and H-mode) and for helium and hydrogen plasmas. The operational space of LPS and pulse length has been explored through density scans with the Heating and Current Drive mix required for the FPO Q $⩾$ 5 steady-state plasma scenario (namely Neutral Beam Injection and Electron Cyclotron Heating) including acceptable shine through losses on the first wall for both helium and hydrogen plasmas. Fast particle physics aspects that are common between FPO plasmas and LPS PFPO H-mode plasmas at low densities are studied including MHD stability analysis with the KINX code and non-perturbative critical gradient model based on high-n Toroidal Alfven Eigenmodes (TAE) stability kinetic ballooning code HINST calculations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing multi-modal, non-axisymmetric plasma response metrics with additional coil rows on DIII-D

The expansion of the DIII-D tokamak operational space via the addition of new non-axisymmetric coil rows is investigated using the linear MHD plasma response code MARS-F. The plasma response to magnetic perturbations imposed by five distinct low- and high-field side coil geometries is modeled for toroidal mode numbers up to n = 6. A set of linear (~δB^2: resonant, kink mode amplitude) and quadratic (~δB: core and edge integrated NTV torque) plasma metrics are defined and compared directly for the various coil geometries. Coil size is also scanned as a secondary optimization variable. An in-vessel coil located at the low-field side midplane is identified as the most efficient plasma response actuator across all metrics and toroidal mode numbers. The multi-row combination of this new midplane (M) coil with the existing DIII-D non-axisymmetric coil set is considered in numerical optimization studies to quantify the impact of this new coil on modeled plasma response metrics. The addition of the M coil is shown to significantly increase the actuator efficiency in maximizing individual plasma response metrics as well as maximizing multi-modal ratios of response metrics, e.g. maximizing resonant modes or edge NTV torque while minimizing kink modes or core NTV torque. The ex-vessel midplane (C) coil is also observed to have an outsize effect on multi-modal optimization due to its uniquely narrow poloidal spectra, and the expansion of optimization space due to the combined use of the two existing in-vessel coil rows with both the M and C coils is notably larger than either coil's individual contribution even though both share similar poloidal locations. This four-row system is expected to greatly extend abilities to understand and optimize the control of transients and rotation on the DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical design of an imaging spectral radiometer for earth resources applications.

Description of the optics, thermal compensation measures, and calibration procedures for a scanning imaging spectroradiometer to be used in earth resources sensing applications. The spectral range covered extends from 4000 to 8500 A. Two possible modes of operation include (1) a high-spatial-resolution terrestrial survey mode with moderate spectral resolution, and (2) a high-spectral-resolution ocean survey mode with decreased spatial resolution. Two high-aperture f/1.4 objective lenses (providing fields of view of 10 and 25 deg) are interchangeable to give added flexibility in planning experiments with this instrument. A diffraction grating disperses the spectrum which is then scanned by the image sensor.

Harris, T. I.↗

Compositional dependence of the nonlinear refractive index of new germanium-based chalcogenide glasses

In this paper, we report results of n{sub 2} measurements of new chalcogenide glasses in the Ge-Sb-S-Se system using a modified Z-Scan technique. Measurements were made with picosecond pulses emitted by a 10 Hz Q-switched mode-locked Nd-YAG laser at 1064 nm under conditions suitable to characterize ultrafast nonlinearities. The nonlinear index increases up to 500 times the n{sub 2} of fused silica with an increase in the Ge/Se ratio and a decrease with an increase of the Ge/Sb ratio. We confirmed, using Raman spectroscopy, that the nonlinear refractive index depends on the number of Ge-S(Se) and Sb-S(Se) bonds in the glass network. Sulfide glasses were shown to have a nonlinear FOM near or <1, at 1064 nm. - Graphical abstract: In this paper, we report results of n{sub 2} measurements of new chalcogenide glasses in the Ge-Sb-S-Se system using a modified Z-Scan technique. n{sub 2} is found to increase with an increase of normalized photon energy, regardless of chalcogen type, but does not depend on the concentration of lone pair electron.

36 MATERIALS SCIENCE↗

Process-microstructure relationship of laser processed thermoelectric material Bi2Te3

Additive manufacturing allows fabrication of custom-shaped thermoelectric materials while minimizing waste, reducing processing steps, and maximizing integration compared to conventional methods. Establishing the process-structure-property relationship of laser additive manufactured thermoelectric materials facilitates enhanced process control and thermoelectric performance. This research focuses on laser processing of bismuth telluride (Bi 2 Te 3 ), a well-established thermoelectric material for low temperature applications. Single melt tracks under various parameters (laser power, scan speed and number of scans) were processed on Bi 2 Te 3 powder compacts. A detailed analysis of the transition in the melting mode, grain growth, balling formation, and elemental composition is provided. Rapid melting and solidification of Bi 2 Te 3 resulted in fine-grained microstructure with preferential grain growth along the direction of the temperature gradient. Experimental results were corroborated with simulations for melt pool dimensions as well as grain morphology transitions resulting from the relationship between temperature gradient and solidification rate. Samples processed at 25 W, 350 mm/s with 5 scans resulted in minimized balling and porosity, along with columnar grains having a high density of dislocations.

Oztan, Cagri↗

Xanthorrhizol induced DNA fragmentation in HepG2 cells involving Bcl-2 family proteins

Highlights: Black-Right-Pointing-Pointer We isolated xanthorrhizol, a sesquiterpenoid compound from Curcuma xanthorrhiza. Black-Right-Pointing-Pointer Xanthorrhizol induced apoptosis in HepG2 cells as observed using SEM. Black-Right-Pointing-Pointer Apoptosis in xanthorrhizol-treated HepG2 cells involved Bcl-2 family proteins. Black-Right-Pointing-Pointer DNA fragmentation was observed in xanthorrhizol-treated HepG2 cells. Black-Right-Pointing-Pointer DNA fragmentation maybe due to cleavage of PARP and DFF45/ICAD proteins. -- Abstract: Xanthorrhizol is a plant-derived pharmacologically active sesquiterpenoid compound isolated from Curcuma xanthorrhiza. Previously, we have reported that xanthorrhizol inhibited the proliferation of HepG2 human hepatoma cells by inducing apoptotic cell death via caspase activation. Here, we attempt to further elucidate the mode of action of xanthorrhizol. Apoptosis in xanthorrhizol-treated HepG2 cells as observed by scanning electron microscopy was accompanied by truncation of BID; reduction of both anti-apoptotic Bcl-2 and Bcl-X{sub L} expression; cleavage of PARP and DFF45/ICAD proteins and DNA fragmentation. Taken together, these results suggest xanthorrhizol as a potent antiproliferative agent on HepG2 cells by inducing apoptosis via Bcl-2 family members. Hence we proposed that xanthorrhizol could be used as an anti-liver cancer drug for future studies.

60 APPLIED LIFE SCIENCES↗

Molecular-Scale Insights into the Heterogeneous Interactions between an m -Terphenyl Isocyanide Ligand and Noble Metal Nanoparticles

The structural and chemical properties of metal nanoparticles are often dictated by their interactions with molecular ligand shells. These interactions are highly material-specific and can vary significantly even among elements within the same group or materials with similar crystal structure. In this study, we surveyed the heterogeneous interactions between an m-terphenyl isocyanide ligand and Au and Ag nanoparticles (NPs) at the single-molecule limit. Specifically, we found that the ligation behavior with this molecule differs significantly between that of Au and AgNPs. Surface-enhanced Raman spectroscopy measurements revealed unique enhancement factors for two molecular vibrational modes between two metal surfaces, indicating different ligand binding geometries. Molecular-level characterization using scanning tunneling microscopy allowed us to directly visualize these variations between Ag and Au surfaces, which we assign as two distinct binding mechanisms. This molecular-scale visualization provides clear insights into the different ligand–metal interactions as well as the chemical behavior and spectroscopic characteristics of isocyanide-functionalized NPs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Acceleration of non-relativistic electrons at a dielectric grating structure: Status report

We report on an experiment aiming at a proof-of-concept of a non-relativistic direct laser accelerator. The system is based on a fused-silica transmission grating illuminated by Titanium:sapphire femtosecond pulses in order to excite evanescent spatial modes, which propagate synchronously with 28 keV electrons originating from an electron column of a scanning electron microscope. The grating period is 750 nm, and we use the third spatial harmonic to continuously accelerate the non-relativistic electrons. With a laser pulse energy of about 150 nJ numerical simulations show expected accelerating gradients of up to 60 MeV/m and an energy gain of around 300 eV at a distance of 100 nm away from the grating surface. The current status of the experiment is reported.

43 PARTICLE ACCELERATORS↗

Electron-cyclotron-resonance heating in Wendelstein 7-X: A versatile heating and current-drive method and a tool for in-depth physics studies

For stellarators, which need no or only small amounts of current drive, electron-cyclotron-resonance heating (ECRH) is a promising heating method even for the envisaged application in a fusion power plant. Wendelstein 7-X (W7-X) is equipped with a steady-state capable ECRH system, operating at 140 GHz, which corresponds to the 2nd cyclotron harmonic of the electrons at a magnetic field of 2.5 T. Ten gyrotrons are operational and already delivered 7 MW to W7-X plasmas. Combined with pellet injection, the highest triple product (0.68 × 10 20 keV m –3 s), observed up to now in stellarators, was achieved. For the first time, W7-X plasmas were sustained by 2nd harmonic O-mode heating, approaching the collisionality regime for which W7-X was optimized. Power deposition scans did not show any indication of electron temperature profile resilience. In low-density, low-power plasmas a compensation of the bootstrap current with electron-cyclotron current drive (ECCD) was demonstrated. Furthermore, sufficiently strong ECCD close to the plasma centre produced periodic internal plasma-crash events, which coincide with the appearance of low order rationals of the rotational transform.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutrino mixing and mass hierarchy in Gaussian landscapes

The flavor structure of the standard model may arise from random selection on a landscape. In a class of simple models, called ''Gaussian landscapes,'' Yukawa couplings derive from overlap integrals of Gaussian zero-mode wave functions on an extra-dimensional space. Statistics of vacua are generated by scanning the peak positions of these wave functions, giving probability distributions for all flavor observables. Gaussian landscapes can account for all of the major features of flavor, including both the small electroweak mixing in the quark sector and the large mixing observed in the lepton sector. We find that large lepton mixing stems directly from lepton doublets having broad wave functions on the internal manifold. Assuming the seesaw mechanism, we find the mass hierarchy among neutrinos is sensitive to the number of right-handed neutrinos and can provide a good fit to neutrino oscillation measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CZT detectors used in different irradiation geometries: Simulations and experimental results

The purpose of this work was to evaluate potential advantages and limitations of CZT detectors used in surface-on, edge-on, and tilted angle irradiation geometries. Simulations and experimental investigations of the energy spectrum measured by a CZT detector have been performed using different irradiation geometries of the CZT. Experiments were performed using a CZT detector with 10x10 mm{sup 2} size and 3 mm thickness. The detector was irradiated with collimated photon beams from Am-241 (59.5 keV) and Co-57 (122 keV). The edge-scan method was used to measure the detector response function in edge-on illumination mode. The tilted angle mode was investigated with the radiation beam directed to the detector surface at angles of 90 degree sign , 15 degree sign , and 10 degree sign . The Hecht formalism was used to simulate theoretical energy spectra. The parameters used for simulations were matched to experiment to compare experimental and theoretical results. The tilted angle CZT detector suppressed the tailing of the spectrum and provided an increase in peak-to-total ratio from 38% at 90 degree sign to 83% at 10 degree sign tilt angle for 122 keV radiation. The corresponding increase for 59 keV radiation was from 60% at 90 degree sign to 85% at 10 degree sign tilt angle. The edge-on CZT detector provided high energy resolution when the beam thickness was much smaller than the thickness of CZT. The FWHM resolution in edge-on illumination mode was 4.2% for 122 keV beam with 0.3 mm thickness, and rapidly deteriorated when the thickness of the beam was increased. The energy resolution of surface-on geometry suffered from strong tailing effect at photon energies higher than 60 keV. It is concluded that tilted angle CZT provides high energy resolution but it is limited to a 1D linear array configuration. The surface-on CZT provides 2D pixel arrays but suffers from tailing effect and charge build up. The edge-on CZT is considered suboptimal as it requires small beam thickness and also suffers from charge buildup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗