Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample integrity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Search for contact interactions and large extra dimensions in dilepton events from p p collisions at s = 7 TeV with the ATLAS detector

CERN-LHC. Study of events with two isolated electrons or muons produced in proton-proton interactions at a centre-of-mass energy of 7 TeV. The data samples used, collected throughout 2011, have integrated luminsoities of 4.9 and 5.0 fb-1 in the electron and muon channels, respectively. The data are used in a search for non-resonant new phenomena, originating from either contact interactions or large extra spatial dimensions. The reader is referred to the text of the paper for more details.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for nonpointing photons in the diphoton and E T m i s s final state in s =7 TeV proton-proton collisions using the ATLAS detector

CERN-LHC. Study of events with a final state comprising two photons and missing transverse energy in proton-proton interactions at a centre-of-mass energy of 7 TeV using a data sample, collected in 2011, with an integrated luminosity of 4.8 fb-1. The analysis is focussed on a search for photons originating in the decay of neutral long-lived particles, exploiting the electromagnetic calorimeters ability to make measurements of the flight direction of the photons as well as excellent time resolution. Results are compared with Standard Model (SM ) expections as well as the predictions from GMSB models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deployment of ADTimePix3 areaDetector Driver at Neutron and X-ray User Facilities

TimePix3 is a 65k hybrid pixel readout chip with simultaneous Time-of-Arrival (ToA) and Time-over-Threshold (ToT) recording in each pixel*. The chip operates without a trigger signal with a sparse readout where only pixels containing events are read out. The flexible architecture allows 40 MHits/s/cm² readout throughput, using simultaneous readout and acquisition by sharing readout logic with transport logic of superpixel matrix formed using 2x4 structure. The chip ToA records 1.5625 ns time resolution. The X-ray and charged particle events are counted directly. However, indirect neutron counts use 6Li fission in a scintillator matrix, such as ZnS(Ag). The fission space-charge region is limited to 5-9 um. A photon from scintillator material excites a photocathode electron, which is further multiplied in dual-stack MCP. The neutron count event is a cluster of electron events at the chip. We report on the EPICS areaDetector** ADTimePix3 driver that controls Serval*** using json commands. The driver directs data to storage and to a real-time processing pipeline and configures the chip. The time-stamped data are stored in raw .tpx3 file format and passed through a socket where the clustering software identifies individual neutron events. The conventional 2D images are available as images for each exposure frame, and a preview is useful for sample alignment. The areaDetector driver allows integration of time-enhanced capabilities of this detector into SNS beamlines controls and unprecedented time resolution.

Gofron, Kaz↗

Development of Large-Area Photo-Detectors (Final Scientific/Technical Report)

This proposal requested ADR funds for two years to make measurements and detector proto-types in the context of planning a program in conjunction with Argonne National Laboratory to develop very large-area planar photodetectors. The proposed detectors have integrated transmission-line readout and sampling electronics able to achieve timing and position resolutions in the range of 1-50 psec and 1-10 mm, respectively. The capability for very precise time measurements is inherent in the design, and provides a third coordinate, orthogonal to the two in the plane, for the point of origin of photons or charged particles, allowing tomographic reconstruction in 3-dimensions inside a volume.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Post-Irradiation Examination of Zircaloy-4 Samples in Target Capsules and Initiation of Bending Fatigue Testing for Used Nuclear Fuel Vibration Integrity Investigations (FY 2013 Summary Report)

This report documents ongoing work performed at Oak Ridge National Laboratory (ORNL) for the Department of Energy, Office of Fuel Cycle Technology Used Fuel Disposition Campaign (UFDC), and satisfies the deliverable for milestone M2FT-13OR0805041, “Data Report on Hydrogen Doping and Irradiation in HFIR.” This work is conducted under WBS 1.02.08.05, Work Package FT-13OR080504 ST “Storage and Transportation-Experiments – ORNL.” The objectives of work packages that make up the S&T Experiments Control Account are to conduct the separate effects tests (SET) and small-scale tests that have been identified in the Used Nuclear Fuel Storage and Transportation Data Gap Prioritization (FCRD-USED-2012-000109). In FY 2013, the R&D focused on cladding and container issues and small-scale tests as identified in Sections A-2.9 and A-2.12 of the prioritization report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analytical Results from the Salt Batch 10 Routine DSSHT and SEHT Monthly Samples

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 10 have been analyzed for 238Pu, 90Sr, 137Cs, elemental constituents (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and in some cases anions (Ion Chromatography Anions - IC-A). The included tables contain the data. These samples are from Salt Batch 10 material recently introduced into the Modular Caustic-Side Solvent Extraction Unit (MCU) system. The DSSHT results are typical for this type of sample, although the dilution due to processing is lower than expected. The August sample is known to have incorporated large amounts of rain water and cannot be compared to other DSSHT samples. The SEHT sample results are typical except for the May sample which is known to have rain water and Contactor Drain Tank (CDT) material in it.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measuring calcium content in plants using NEXAFS spectroscopy

Calcium is important for the growth and development of plants. It serves crucial functions in cell wall and cell membrane structure and serves as a secondary messenger in signaling pathways relevant to nutrient and immunity responses. Thus, measuring calcium levels in plants is important for studies of plant biology and for technology development in food, agriculture, energy, and forest industries. Often, calcium in plants has been measured through techniques such as atomic absorption spectrophotometry (AAS), inductively coupled plasma–mass spectrometry (ICP-MS), and electrophysiology. These techniques, however, require large sample sizes, chemical extraction of samples or have limited spatial resolution. Here, we used near-edge X-ray absorption fine structure (NEXAFS) spectroscopy at the calcium L- and K-edges to measure the calcium to carbon mass ratio with spatial resolution in plant samples without requiring chemical extraction or large sample sizes. We demonstrate that the integrated absorbance at the calcium L-edge and the edge jump in the fluorescence yield at the calcium K-edge can be used to quantify the calcium content as the calcium mass fraction, and validate this approach with onion epidermal peels and ICP-MS. We also used NEXAFS to estimate the calcium mass ratio in hypocotyls of a model plant, Arabidopsis thaliana , which has a cell wall composition that is similar to that of onion epidermal peels. These results show that NEXAFS spectroscopy performed at the calcium edge provides an approach to quantify calcium levels within plants, which is crucial for understanding plant physiology and advancing plant-based materials.

59 BASIC BIOLOGICAL SCIENCES↗

The Chandra cosmos legacy survey: clustering of X-ray-selected AGNs at 2.9 ≤ z ≤ 5.5 using photometric redshift probability distribution functions

We present the measurement of the projected and redshift-space two-point correlation function (2pcf) of the new catalog of Chandra COSMOS-Legacy active galactic nucleus (AGN) at 2.9 ≤ z ≤ 5.5 (〈L{sub bol}〉 ∼ 10{sup 46} erg s{sup −1}) using the generalized clustering estimator based on phot-z probability distribution functions in addition to any available spec-z. We model the projected 2pcf, estimated using π {sub max} = 200 h{sup −1} Mpc with the two-halo term and we derive a bias at z ∼ 3.4 equal to b = 6.6{sub −0.55}{sup +0.60}, which corresponds to a typical mass of the hosting halos of log M {sub h} = 12.83{sub −0.11}{sup +0.12} h{sup −1} M {sub ⊙}. A similar bias is derived using the redshift-space 2pcf, modeled including the typical phot-z error σ {sub z} = 0.052 of our sample at z ≥ 2.9. Once we integrate the projected 2pcf up to π {sub max} = 200 h{sup −1} Mpc, the bias of XMM and Chandra COSMOS at z = 2.8 used in Allevato et al. is consistent with our results at higher redshifts. The results suggest only a slight increase of the bias factor of COSMOS AGNs at z ≳ 3 with the typical hosting halo mass of moderate-luminosity AGNs almost constant with redshift and equal to log M {sub h} = 12.92{sub −0.18}{sup +0.13} at z = 2.8 and log M {sub h} = 12.83{sub −0.11}{sup +0.12} at z ∼ 3.4, respectively. The observed redshift evolution of the bias of COSMOS AGNs implies that moderate-luminosity AGNs still inhabit group-sized halos at z ≳ 3, but slightly less massive than observed in different independent studies using X-ray AGNs at z ≤ 2.

79 ASTRONOMY AND ASTROPHYSICS↗

Radial Profiles of the Binary Fraction in Elliptical Galaxies

The radial profile of the binary fraction may vary with environment and is of significant importance for studying the formation mechanisms of binary stars and their dynamical evolution within globular clusters and galaxies. However, existing studies remain limited to the Milky Way and its neighboring galaxies. Leveraging the method proposed by Zhang et al. for estimating the variation in the binary fraction from integrated spectral features, we analyze a sample of 513 elliptical galaxies drawn from the Mapping Nearby Galaxies at Apache Point Observatory survey to measure their radial binary fraction profiles. Our results show that after accounting for the effect induced by radial variations in the stellar population (SP), the median SP-subtracted binary fraction, $r^{\textrm{med}}_{\textrm{b,sub}}$, becomes approximately flat. For nearly all elliptical galaxies in our sample, the variation in the binary fraction relative to the galaxy center at 1R e is less than 5%. No clear correlation is found between the ​​​​​gradient of the binary fraction and the gradients of the SP properties. Moreover, we also compare differences between ultraviolet (UV) upturn and non-UV upturn galaxies. The overall binary fraction profiles and the SP properties of the non-UV upturn galaxies in our sample are comparable to those of the UV upturn galaxies. This similarity may arise from the presence of residual star formation in the non-UV upturn systems.

Li, Xiejin [Chinese Academy of Sciences; Universit↗

New Composite Membranes for High Throughput Solid-Liquid Separations at the Savannah River Site

New Composite Membranes for High Throughput Solid-Liquid Separations at the Savannah River Site R. Bhave (Oak Ridge National Laboratory. Oak Ridge, TN) and M. R. Poirier* (Savannah River National Laboratory, Aiken SC) Solid-liquid separation is the limiting step for many waste treatment processes at the Savannah River Site. SRNL researchers have identified the rotary microfilter as a technology to improve the rate of solid-liquid separation processes. SRNL is currently developing the rotary microfilter for radioactive service and plans to deploy the technology as part of the small column ion exchange process. The rotary microfilter can utilize any filter media that is available as a flat sheet. The current baseline membrane is a 0.5 micron (nominal) porous metal filter (Pall PMM050). Previous testing with tubular filters showed that filters composed of a ceramic membrane on top of a stainless steel support produce higher flux than filters composed only of porous metal. The authors are working to develop flat sheet filter media composed of a ceramic membrane and/or ceramic-metal composite on top of a porous stainless steel support that can be used with the rotary microfilter to substantially increase filter flux resulting in a more compact, energy efficient and cost-effective high level radioactive waste treatment system. Composite membranes with precisely controlled pore size distribution were fabricated on porous metal supports. High quality uniform porous metal (316SS) supports were fabricated to achieve high water permeability. Separative layers of several different materials such as ultrafine metal particles and ceramic oxides were used to fabricate composite membranes. The fabrication process involved several high temperature heat treatments followed by characterization of gas and liquid permeability measurements and membrane integrity analysis. The fabricated composite membrane samples were evaluated in a static test cell manufactured by SpinTek. The composite membranes were evaluated on several feed slurries: 1 wt. % strontium carbonate in deionized water, 1 wt. % monosodium titanate in simulated salt solution, and 1 wt. % simulated sludge in simulated salt solution and deionized water. Flux as a function of feed flow rate and transmembrane pressure was measured for each of the above described feed slurries. The authors will discuss the new membrane development efforts, waste slurry filtration performance evaluations and scale-up considerations.

Bhave, Ramesh R↗

PNEUMATIC MICROVALVE FOR ELECTROKINETIC SAMPLE PRECONCENTRATION AND CAPILLARY ELECTROPHORESIS INJECTION

Here we show that a closed pneumatic microvalve on a PDMS chip can serve as a semipermeable membrane under an applied potential, enabling current to pass through while blocking the passage of charged analytes. Enrichment of both anionic and cationic species has been demonstrated, and concentration factors of ~70 have been achieved in just 8 s. Once analytes are concentrated, the valve is briefly opened and the sample is hydrodynamically injected onto an integrated microchip or capillary electrophoresis (CE) column. In contrast to existing preconcentration approaches, the membrane-based method described here enables both rapid analyte concentration as well as high resolution separations.

Environmental Molecular Sciences Laboratory↗

Challenges and Practical Solutions for Conducting Structural MARSSIM Surveys in Elevated Radon Environments - 20413

The Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) [1] provides comprehensive guidance for the development and implementation of radiological surveys conducted to demonstrate compliance with a dose- or risk-based cleanup goal during final status survey. The MARSSIM methodology follows an integrated strategy combining direct measurements and sampling to assess uniform residual contamination, and scanning surveys to identify localized areas of elevated activity. Building surveys assessing residual surface contamination present unique challenges from reliance on field measurements that may be subject to less than ideal environmental conditions. Additionally, limited characterization and excessive conservatism incorporated into the conceptual site model may result in derived concentration guideline levels (DCGL) and, as a consequence of relatively inefficient field instrumentation, corresponding attributable count rates generally comparable to background. The presence of elevated ambient radon concentrations and associated progeny deposition both exacerbate these intrinsic survey challenges and introduce a series of technical, logistic, and administrative obstacles that can wreak havoc on the statistical legitimacy of each component of the MARSSIM process. Short-lived radon progeny including polonium-218, lead-214, bismuth-214, and polonium-214 produce excessive alpha and beta radiation that may decrease instrument sensitivity through an increase in background count rates, and, at worst, may result in incorrect survey unit failure through the simulation of residual surface activity. Aside from the obvious solution of exhaustive radon mitigation, the primary objectives are to distinguish between radon progeny deposition and actual surface activity, and collect sufficient defensible data. The following is a technical discussion of the consequences of performing building MARSSIM surveys in the presence of elevated ambient radon atmospheres, conceptual examples, and an overview of practical strategies to minimize the effects of radon interference while collecting sufficient defensible data to complete the survey. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

D0 SUSY/BSM searches

We report on D0 searches for supersymmetry (SUSY) at the TEVATRON Run II. Analyses with data samples in the following range of integrated luminosities 1 < {integral} Ldt < 2.1 fb{sup -1} are summarized. These searches look for different production processes and decay channels in gravity and gauge mediated SUSY breaking models. No excess of observed events is found with respect to the Standard Model (SM) predictions, therefore a series of exclusion limits at the 95% confidence level (C.L.) are drawn.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the tt production cross section in 2 fb{sup -1} of pp collisions at {radical}(s)=1.96 TeV using lepton plus jets events with soft muon b tagging

We present a measurement of the tt production cross section in pp collisions at {radical}(s)=1.96 TeV using events containing a high transverse momentum electron or muon, three or more jets, and missing transverse energy. Events consistent with tt decay are found by identifying jets containing candidate heavy-flavor semileptonic decays to muons. The measurement uses a CDF run II data sample corresponding to 2 fb{sup -1} of integrated luminosity. Based on 248 candidate events with three or more jets and an expected background of 79.5{+-}5.3 events, we measure a production cross section of 9.1{+-}1.6 pb.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of double parton interactions in diphoton + dijet events in $p\bar{p}$ collisions at $\sqrt{s} = 1.96$ TeV

We use a sample of diphoton+dijet events to measure the effective cross section of double parton interactions, which characterizes the area containing the interacting partons in proton-antiproton collisions, and find it to be σeff=19.3±1.4(stat)±7.8(syst) mb. The sample was collected by the D0 detector at the Fermilab Tevatron collider in pp¯ collisions at s=1.96 TeV and corresponds to an integrated luminosity of 8.7 fb-1.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uncertainty Quantification of a Light Water Pulsed-Neutron Die-Away Experiment to Thermal Neutron Scattering Laws

Thermal neutron scattering laws are important nuclear data for many nuclear science and engineering applications. Validation helps to ensure that a thermal neutron scattering law has a high quality and often employs critical benchmarks as integral experiments. Recently, pulsed-neutron die-away benchmarks have been used as an experiment to validate thermal neutron scattering laws. Herein, we evidence how this alternative integral experiment has a high sensitivity to these nuclear data by performing an uncertainty quantification analysis. The analysis randomly sampled the nuclear model parameters associated with hydrogen bound in light water thermal neutron scattering law and sampled other nuclear data that influenced the experiment’s integral parameter (e.g., elastic scattering, absorption in hydrogen and oxygen) from their respective covariance matrices. The thermal neutron scattering law caused an uncertainty in the integral parameter that reached 2.67%, which exceeds by an order of magnitude the uncertainties induced in commonly used thermal solution critical benchmarks. The validation performed here, although limited due to a poor description of the historical experiment, indicated that the ENDF/B-VIII.0 thermal neutron scattering law well predicted the integral parameter. These results motivate further benchmark and validation efforts using pulsed-neutron die-away experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A measurement of the CP asymmetry difference between Λ c + → pK – K + and pπ – π + decays

The difference between the CP asymmetries in the decays Λ c + → pK – K + and Λ c + → pπ – π + is presented. Proton-proton collision data taken at centre-of-mass energies of 7 and 8 TeV collected by the LHCb detector in 2011 and 2012 are used, corresponding to an integrated luminosity of 3 fb –1 . The Λ c + candidates are reconstructed as part of the Λ b o → Λ c + μ – X decay chain. In order to maximize the cancellation of production and detection asymmetries in the difference, the final-state kinematic distributions of the two samples are aligned by applying phase-space-dependent weights to the Λ c + → pπ – π + sample. This alters the definition of the integrated CP asymmetry to A CP wgt (pπ – π + ).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Top Quark Mass Simultaneously in Dilepton and Lepton + Jets Decay Channels

The authors present the first measurement of the top quark mass using simultaneously data from two decay channels. They use a data sample of √s = 1.96 TeV collisions with integrated luminosity of 1.9 fb -1 collected by the CDF II detector. They select dilepton and lepton + jets channel decays of t$\bar{t}$ pairs and reconstruct two observables in each topology. They use non-parametric techniques to derive probability density functions from simulated signal and background samples. The observables are the reconstructed top quark mass and the scalar sum of transverse energy of the event in the dilepton topology and the reconstructed top quark mass and the invariant mass of jets from the W boson decay in lepton + jets channel. They perform a simultaneous fit for the top quark mass and the jet energy scale which is constrained in situ by the hadronic W boson resonance from the lepton + jets channel. Using 144 dilepton candidate events and 332 lepton + jets candidate events they measure: M top = 171.9 ± 1.7 (stat. + JES) ± 1.1 (other sys.) GeV/c 2 = 171.9 ± 2.0 GeV/c 2 . The measurement features a robust treatment of the systematic uncertainties, correlated between the two channels and develops techniques for a future top quark mass measurement simultaneously in all decay channels. Measurements of the W boson mass and the top quark mass provide a constraint on the mass of the yet unobserved Higgs boson. The Higgs boson mass implied by measurement presented here is higher than Higgs boson mass implied by previously published, most precise CDF measurements of the top quark mass in lepton + jets and dilepton channels separately.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗