Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “respirable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

A cardiovascular system model for lower-body negative pressure response

Mathematical models used to study complex physiological control systems are discussed. Efforts were made to modify a model of the cardiovascular system for use in studying lower body negative pressure. A computer program was written which allows orderly, straightforward expansion to include exercise, metabolism (thermal stress), respiration, and other body functions.

Mitchell, B. A., Jr.↗

Digital automatic data reduction techniques used in a 1000-flight biomedical study

Techniques developed to automatically process a large quantity of physiological data obtained during a 1000-flight study are described. To reduce this data reliably, a study program was conducted using physiological data from X-15 flights as a data source for experimenting with signal enhancement and noise elimination techniques. The techniques include an automatic means for counting heart rates, averaging electrocardiogram waveforms, plotting histograms of heart rate versus frequency, and counting respiration rates. These techniques were used to reduce more than 2000 hours of physiological data recorded in flight.

Carpenter, R.↗

Development of techniques for measuring pilot workload

An objective method of assessing information workload based on physiological measurements was developed. Information workload, or reserve capacity, was measured using a visual discrimination secondary task and subjective rating of task difficulty. The primary task was two axis (pitch and roll) tracking, and the independent variables in this study were aircraft pitch dynamics and wind gust disturbances. The study was structured to provide: (1) a sensitive, nonloading measure of reserve capacity, and (2) an unencumbering reliable measurement of the psychophysiological state. From these, a measured workload index (MWI) and physiological workload index (PWI) were extracted. An important measure of the success of this study was the degree to which the MWI and PWI agreed across the 243 randomly-presented, four-minute trials (9 subjects X 9 tasks X 3 replications). The electrophysiological data collected included vectorcardiogaram, respiration, electromyogram, skin impedance, and electroencephalogram. Special computer programs were created for the analysis of each physiological variable. The digital data base then consisted of 82 physiological features for each of the 243 trials. A prediction of workload based on physiological observations was formulated as a simultaneous least-squares prediction problem. A best subset of 10 features was chosen to predict the three measures of reserve capacity. The cannonical correlation coefficient was .754 with a chi squared value of 91.3 which allows rejection of the null hypothesis with p of .995.

Spyker, D. A.↗

Potato respirometer experiment SO61

The design and manufacture of a respirometer for measuring the oxygen consumption rate of a respiring potato sprout in a Skylab experiment is reported. The device monitors low gravity effects on the biorhythmicity of organisms during space flight. Several experimental runs using bench mounted flight hardware units were inconclusive due to room temperature induced artifacts.

Taudvin, P. C.↗

Metabolic, respiratory, and cardiological measurements during exercise and rest

Low concentration effects of CO2 on metabolic respiration and circulation were measured during work and at rest. The relationship between heart rate and metabolic rate is examined, as well as calibration procedures, and rate measurement during submaximal and standard exercise tests. Alterations in acid base and electrolytes were found during exhaustive exercise, including changes in ECG and metabolic alkalosis effects.

Source record↗

Vacuum distillation: vapor filtered-catalytic oxidation water reclamation system utilizing radioisotopes

The development of a functional model water reclamation system is discussed. The system produces potable water by distillation from the urine and respiration-perspiration condensate at the normal rate generated by four men. Basic processes employed are vacuum distillation, vapor filtration, vapor phase catalytic oxidation, and condensation. The system is designed to use four 75-watt isotope heaters for distillation thermal input, and one 45-watt isotope for the catalytic oxidation unit. The system is capable of collecting and storing urine, and provides for stabilizing the urine by chemical pretreatment. The functional model system is designed for operation in a weightless condition with liquid-vapor phase separators for the evaporator still, and centrifugal separators for urine collection and vapor condensation. The system provides for storing and dispensing reclaimed potable water. The system operates in a batch mode for 40 days, with urine residues accumulating in the evaporator. The evaporator still and residue are removed to storage and replaced with a fresh still for the next 40-day period.

Honegger, R. J.↗

Operation and testing of Mark 10 Mod 3 underwater breathing apparatus

Performance tests on a closed circuit, mixed gas underwater breathing apparatus are reported. The equipment is designed to provide a minimum diving duration of four hours at 1500 ft below sea surface; it senses oxygen partial pressure in the breathing gas mix and controls oxygen content of the breathing gas within narrow limits about a preset value. The breathing circuit subsystem provides respirable gas to the diver and removes carbon dioxide and moisture from the expired gas. Test results indicate undesirable variations in oxygen partial pressure with oxygen addition and insufficient carbon dioxide absorption.

Milwee, W. I., Jr.↗

The study of human venous system dynamics using hybrid computer modeling

A computer-based model of the cardiovascular system was created emphasizing effects on the systemic venous system. Certain physiological aspects were emphasized: effects of heart rate, tilting, changes in respiration, and leg muscular contractions. The results from the model showed close correlation with findings previously reported in the literature.

Snyder, M. F.↗

The development of spectro-signature indicators of root disease impacts on forest stands

A field research program was begun in 1969 and intensified in 1970 on the physiology and biophysical responses of second-growth Douglas fir infected with root rot fungus. A double tramway system was suspended between three 100-foot instrument towers to carry sensors for measuring the energy response from above both healthy and infected trees. Processing and analysis was completed of airborne multispectral scanner imagery collected over the Wind River research area in 1969. Likelihood ratio processing of three-channel infrared data and Euclidean distance analysis of ten-channel spectrometer data did not identify incipient root rot infection outside the training sets. In all cases infected fir was misclassified as healthy fir. It was concluded from careful examination of physiological data that Poria root rot infection has little effect on water metabolism and energy exchange. What was identified was a low-grade stress that affects respiration and metabolism over long periods of time. This led to minor changes in the external physical symptoms of Poria-infected trees which was revealed only in the shortwave reflectance data.

Weber, F. P.↗

Rare-gas effects on metabolism and inert gas narcosis

The detailed examination is reported of the theory that narcosis results from expansion of the cell membrane under high partial pressures. The research is partially based on the hypothesis that, like oxygen toxicity, the mechanism of metabolic effects of rare gases may be similar at both low and high pressures and are simply more observable at high pressures. Using adult female goats, the parameters measured include oxygen consumption, CO2 production, respiration rate, heart rate, rectal and skin temperatures and the analysis of electroencephalograms and evoked response. Additionally, the specific activity is measured of plasma glucose subsequent to injection of glucose-UL-C-14, intravenous infusion, specific activity of expired CO2, unesterified fatty acid levels and whole blood lactate-to-pyruvate ratios. Also studied were the effects of acetylsalicylic acid, vitamin E and cationic detergents (which alleviate narcosis) upon metabolic changes induced by high pressure narcosis.

Source record↗

Breathing metabolic simulator.

Description of a device for simulation of the human breathing and metabolic parameters required for the evaluation of respiratory diagnostic, monitoring, support and resuscitation equipment. The remotely controlled device allows wide variations in breathing rate and depth, breath velocity contour, oxygen uptake and carbon dioxide release to simulate conditions from sleep to hard work, with respiration exchange ratios ranging from hypoventilation to hyperventilation. It also reduces the cost of prolonged testing when simulation chambers with human subjects require three shifts of crews and standby physicians. Several block diagrams of the device and subsystems are given.

Bartlett, R. G., Jr.↗

Biomedical transducers.

Examples are given of some of the sensors and attachment techniques that have been developed during the last few years at the NASA centers for use in the space program. A detailed description is first given of the successive development of ECG electrodes, starting from their original simple form, that eventually resulted in the novel technology of spray-on electrodes. Finally, features of a new telemetering system under development, which is suitable for the recovery of ECG, respiration, body core temperature, and surface temperature, are outlined.

Stuart, J. L.↗

Evidence for a metabolic limitation of survival in hypothermic hamsters.

The underlying factors limiting survival in the hypothermic state are studied. Hamsters of both sexes, clipped and unclipped, were inducted into profound hypothermia by the helium cold method until they reached a temperature between 7 and 10 C. It appears that the primary cause of death is failure of respiration due to the depletion of carbohydrate energy supplies and may explain why survival time in hypothermia is shorter than the normal hibernation time of the hamster.

Prewitt, R. L.↗

Regeneration of oxygen from carbon dioxide and water.

In a closed ecological system it is necessary to reclaim most of the oxygen required for breathing from respired carbon dioxide and the remainder from waste water. One of the advanced physicochemical systems being developed for generating oxygen in manned spacecraft is the solid electrolyte-electrolysis system. The solid electrolyte system consists of two basic units, an electrolyzer and a carbon monoxide disproportionator. The electrolyzer can reclaim oxygen from both carbon dioxide and water. Electrolyzer preparation and assembly are discussed together with questions of reactor design and electrolyzer performance data.

Weissbart, J.↗

Effects of stress upon psychophysiological responses and performance following sleep deprivation

The usefulness of psychological and physiological variables in predicting performance under stress of 48 hours of sleep deprivation was investigated. Performance tests, with subjects of different ego strength personalities, in concept acquisition, reading comprehension, word association, word memory, and anagrams were conducted, and physiological measurements of (1) the phasic and tonic electrodermal, (2) galvanic skin response, (3) thermal skin resistance, (4) heart rate, (5) respiration, and (6) plethysmographic finger pulse volumn were recorded. It was found that the changes in the pattern of performance were the result of testing subjects at times when they would normally be sleeping, and that sleep deprivation longer than 48 hours must be maintained to produce changes in simple or well learned tasks.

Roessler, R.↗

Biomedical technology transfer applications of NASA science and technology

The identification and solution of research and clinical problems in cardiovascular medicine which were investigated by means of biomedical data transfer are reported. The following are sample areas that were focused upon by the Stanford University Biomedical Technology Transfer Team: electrodes for hemiplegia research; vectorcardiogram computer analysis; respiration and phonation electrodes; radiotelemetry of intracranial pressure; and audiotransformation of the electrocardiographic signal. It is concluded that this biomedical technology transfer is significantly aiding present research in cardiovascular medicine.

Source record↗

The Automated Primate Research Laboratory (APRL)

A description is given of a self-contained automated primate research laboratory to study the effects of weightlessness on subhuman primates. Physiological parameters such as hemodynamics, respiration, blood constituents, waste, and diet and nutrition are analyzed for abnormalities in the simulated space environment. The Southeast Asian pig-tailed monkey (Macaca nemistrina) was selected for the experiments owing to its relative intelligence and learning capacity. The objective of the program is to demonstrate the feasibility of a man-tended primate space flight experiment.

Pace, N.↗