Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rechargeable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Effects of Carbonate Solvents and Lithium Salts on Morphology and Coulombic Efficiency of Lithium Electrode

The application of lithium (Li) metal anode in rechargeable batteries is hindered by Li dendrite growth during Li deposition and low Li Coulombic efficiency (CE), where the nonaqueous electrolyte plays a critical role. In this work, the effects of different carbonate solvents and Li salts on Li deposition morphology and CE were systematically investigated. Typically cyclic carbonates are found to favor the formation of uniform Li film and improve Li CE than linear carbonates do. Several specific cyclic carbonates that are conventionally used as solid electrolyte interface formation additives in Li ion batteries can also improve the CE of Li anode. Furthermore, among the nine electrolyte salts studied, LiAsF6 and LiBOB lead to the highest CE for Li anode. LiBOB also leads to much smoother Li morphology than other salts do. Considering the better safety of LiBOB as compared to LiAsF6, LiBOB is a promising Li salt for rechargeable Li metal batteries with high CE. By combining the best electrolyte solvent/salt that can lead to high Li CE and novel electrolyte additives that can prevent dendrite formation, it is possible to find an electrolyte that not only prevents Li dendrite formation but also lead to high CE during Li deposition/stripping processes.

Environmental Molecular Sciences Laboratory↗

Modeling the Effects of Groundwater-fed Irrigation on Terrestrial Hydrology over the Conterminous United States

Human alteration of the land surface hydrologic cycle is substantial. Recent studies suggest that local water management practices including groundwater pumping and irrigation could significantly alter the quantity and distribution of water in the terrestrial system, with potential impacts on weather and climate through land-atmosphere feedbacks. In this study, we incorporated a groundwater withdrawal scheme into the Community Land Model version 4 (CLM4). To simulate the impact of irrigation realistically, we calibrated the CLM4 simulated irrigation amount against observations from agriculture census at the county scale over the conterminous United States (CONUS). The water used for irrigation was then removed from the surface runoff and groundwater aquifer according to a ratio determined from the county-level agricultural census data. Based on the simulations, the impact of groundwater withdrawals for irrigation on land surface and subsurface fluxes were investigated. Our results suggest that the impacts of irrigation on latent heat flux and potential recharge when water is withdrawn from surface water alone or from both surface and groundwater are comparable and local to the irrigation areas. However, when water is withdrawn from groundwater for irrigation, greater effects on the subsurface water balance were found, leading to significant depletion of groundwater storage in regions with low recharge rate and high groundwater exploitation rate. Our results underscore the importance of local hydrologic feedbacks in governing hydrologic response to anthropogenic change in CLM4 and the need to more realistically simulate the two-way interactions among surface water, groundwater, and atmosphere to better understand the impacts of groundwater pumping on irrigation efficiency and climate.

conterminous↗

Long-Term Drainage from the Riprap Side Slope of a Surface Barrier

Surface barriers designed to isolate underground nuclear waste in place are expected to function for at least 1000 years. To achieve this long design life, such barriers need to be protected with side slopes against wind- and water-induced erosion and damage by natural or human activities. However, the side slopes are usually constructed with materials coarser than the barrier. Their hydrological characteristics must be understood so that any drainage from them is considered in the barrier design and will not compromise the barrier function. The Prototype Hanford Barrier, an evapotranspiration-capillary (ETC) barrier, was constructed in 1994 at the Hanford Site in southeastern Washington state, with a gravel side slope and a riprap side slope. The soil water content in the gravel side slope and drainage from both side slopes have been monitored since the completion of construction. The monitoring results show that under natural precipitation the annual drainage rates from the two types of side slopes were very similar and about 5 times the typical recharge from local soil with natural vegetation and 40 times the barrier design criterion. The higher recharge from the side slopes results in some of the drainage migrating laterally to the region beneath the ETC barrier. This edge effect of the enhanced drainage was evaluated for a period of 1000 years by numerical simulation. The edge effect was quantified by the amount of water across the barrier edges and the affecting distance of the barrier edges. These results indicate that design features can be adjusted to reduce the edge effect when necessary.

Alternative Cover↗

Constraining Bedrock Groundwater Residence Times in a Mountain System with Environmental Tracer Observations and Bayesian Uncertainty Quantification: Modeling and Data Package

Groundwater residence times provide fundamental descriptions of hydrologic dynamics and mixing processes in mountainous watersheds. Yet, few observational datasets that can constrain groundwater residence times over broad timescales are available in high elevation mountain systems. Here we present field observations from May 2021 of dissolved noble gases (He, Ne, Ar, Kr, and Xe), Chloroflourcarbons (CFCs), Sulfurhexaflouride (SF6), and tritium (3H) sampled from the Pumphouse Lower Montane study site (wells PLM1, PLM6, and PLM7) within the East River Watershed, Colorado. The presented noble gas (PLM_noblegas_2021.csv) and environmental tracer (PLM_tracers_2021.csv) observation datasets, along with the associated modeling scripts, aide in quantifying groundwater residence times and recharge conditions in a high elevation mountain system. Furthermore, the modeling scripts quantify groundwater residence time and noble gas recharge condition uncertainties using a novel Markov-chain Monte Carlo approach. All data modeling scripts are written in the Python code.

54 ENVIRONMENTAL SCIENCES↗

Stabilizing the surface of lithium metal

Lithium metal is an ideal anode for the next generation of high capacity rechargeable batteries, including Li-air, Li-S, and other Li-based batteries using intercalation compounds. To enable the broad applications for lithium anodes, more fundamental studies need to be conducted to simultaneously address the two barriers discussed above. One of the key breakthroughs in this field may come from the development of new electrolytes (and additives) which can form a stable SEI layer with enough mechanical strength and flexibility. The ideal electrolyte may consist of only two components; one component inhibits dendrite growth, while another component forms a stable SEI layer to improve Coulombic efficiency. In this review, the status of three approaches at manipulating and controlling the lithium metal – electrolyte interface were discussed. While previous studies concentrated on coatings with minimal surface connectivity, the approaches discussed, namely a coating that forms and dissipates into the electrolyte based on charge density, a coating bonded to the termination layer of lithium, and a conformal carbonate coating formed at the interface, all highlight new research directions. Although there are still many obstacles to be overcome, we are optimistic that Li metal can be used as an anode in rechargeable batteries in the foreseeable future. This will enable wide

36 MATERIALS SCIENCE↗

R&D GREET Battery Carbon Footprint Calculator

The Battery Carbon Footprint (CF) Calculator was developed to help U.S. battery manufacturers meet the carbon footprint reporting requirements of the EU Battery Regulation (EU) 2023/1542. The calculator incorporates several major battery carbon footprint frameworks, including the Joint Research Centre's Rules for the Calculation of the Carbon Footprint of Electric Vehicle Batteries (CFB-EV), RECHARGE's Product Environmental Footprint Category Rules for High Specific Energy Rechargeable Batteries for Mobile Applications (PEFCR), the Catena-X Product Carbon Footprint Rulebook (CX-PCF Rules), Battery Pass's Battery Carbon Footprint: Rules for Calculating the Carbon Footprint of the "Distribution" and "End-of-Life and Recycling" Life Cycle Stages, the Global Battery Alliance's Greenhouse Gas Rulebook: Generic Rules, Version 2.1, and the Ministry of Economy, Trade and Industry's draft Carbon Footprint Calculation Method for Automotive Batteries. The tool pairs these frameworks with foreground data from Argonne's R&D GREET models and integrates user-supplied background data covering battery manufacturing and supply chain activities. By bringing multiple international methodologies together in a single platform, the calculator enables manufacturers to evaluate product carbon footprints, improve data consistency, and prepare for evolving regulatory compliance and global market reporting requirements.

Zhang, Jingyi↗

Influence of Clastic Dikes on Vertical Migration of Contaminants at the Hanford Site

Clastic dikes are subvertical sedimentary features that cut through horizontally layered sediments, and they are common at the Hanford Site. Because of their cross-cutting relationship with the surrounding matrix, they have been proposed as potential fast paths from former contaminant discharge sites at the surface to the water table. However, little was known of the detailed hydrogeologic properties of the dikes and detailed modeling of flow and transport through the dikes had not been performed. We excavated a 2 m wide clastic dike at the Hanford Site and characterized it using an air minipermeameter, infrared imagery, and grain size analyses. Field injection experiments were also used to characterize the system. The resulting data were used to prepare a detailed numerical model of the clastic dike and surrounding matrix for a portion of the excavation. Unsaturated flow and transport through the system were modeled for several recharge rates. The highly heterogeneous nature of the system led to complex behavior, with the relative flux rates in the matrix and clastic dike being highly dependent on the recharge rates that were imposed on the system. The study suggests that the potential role of clastic dikes in vertical transport at the Hanford Site would depend on the leakage rate, and that areas of contaminant deposition formed at high flow rates might become isolated at low flow rates, and vice-versa. The results may also help explain the occurrence of complex breakthrough patterns of contaminants at the water table.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Deep Vadose Zone Respiration Contributions to Carbon Dioxide Fluxes from a Semiarid Floodplain

Core Ideas A significant fraction of CO 2 fluxes from a semiarid floodplain originates from below the root zone. Measured and calculated field CO 2 fluxes are consistent. Laboratory‐measured respiration rates are consistent with field results. Although CO 2 fluxes from soils are often assumed to originate within shallow soil horizons (<1‐m depth), relatively little is known about respiration rates at greater depths. We compared measured and calculated CO 2 fluxes at the Rifle floodplain along the Colorado River and measured CO 2 production rates of floodplain sediments to determine the relative importance of deeper vadose zone respiration. Calculations based on measured CO 2 gradients and estimated effective diffusion coefficients yielded fluxes that are generally consistent with measurements obtained at the soil surface (326 g C m −2 yr −1 ). Carbon dioxide production from the 2.0‐ to 3.5‐m depth interval was calculated to contribute 17% of the total floodplain respiration, with rates that were larger than some parts of the shallower vadose zone and underlying aquifer. Microbial respiration rates determined from laboratory incubation tests of the sediments support this conclusion. The deeper unsaturated zone typically maintains intermediate water and air saturations, lacks extreme temperatures and salinities, and is annually resupplied with organic carbon from snowmelt‐driven recharge and by water table decline. This combination of favorable conditions supports deeper unsaturated zone microbial respiration throughout the year.

Tokunaga, Tetsu K.↗

The Application of Radon for Mapping Open Fracture Networks in a Thin Vadose Zone

The use of naturally occurring tracers to elucidate subsurface flow and transport of water and gasses through fractured vadose zones represents a powerful and inexpensive methodology for understanding geologic systems. Our study was conducted at Sheply’s Hill, a highly fractured granite highland at the old Fort Devens military base. This study evaluates the applicability of using cheap, readily available passive radon detectors to identify conductive structures (e.g., fractures and fracture networks) in fracture-dominated vadose zones. Radon data from this study provides strong evidence that, even within an intensively fractured system, a relatively smaller subset of the fractures is responsible for the majority of the vertical migration of gas and water that recharges contaminated groundwater sites. Our study found that zones of high recharge potential associated with open fracture networks could be identified based on the 222 Rn flux within the highly fractured Shepley’s Hill. Based on the results of this study, 222 Rn is an environmental tracer capable of efficiently detecting major bedrock fracture sets in the vadose zone responsible for water infiltration into contaminated aquifers. Results from the Shepley’s Hill study show a clear spatial correlation of elevated 222 Rn concentrations emanating from fracture zones previously identified by independent geologic studies. At Shepley’s Hill, the 222 Rn concentrations measured from detector locations directly above the major bedrock fractures, located within the Disc Golf Fracture Zone (DGFZ) and the Nona-Shep Fracture Zone (NSFZ), were almost exclusively the highest values measured in the study. Conversely, probes located above areas of less-fractured bedrock, although highly fractured, showed relatively low 222 Rn concentrations. Furthermore, these two observations provide strong supporting evidence that not all fractures are equal when it comes to their ability to transmit gas or water into and out of the subsurface.

58 GEOSCIENCES↗

Experimental calibration of an Fe3+/Fe2+-in-amphibole oxybarometer and its application to shallow magmatic processes at Shiveluch Volcano, Kamchatka

Abstract Oxygen fugacity is an important but difficult parameter to constrain for primitive arc magmas. In this study, the partitioning behavior of Fe3+/Fe2+ between amphibole and glass synthesized in piston-cylinder and cold-seal apparatus experiments is developed as an oxybarometer, applicable to magmas ranging from basaltic to dacitic composition. The partitioning of Fe2+ is strongly dependent on melt polymerization; the relative compatibility of Fe2+ in amphibole decreases with increasing polymerization. The Fe2+/Mg distribution coefficient between amphibole and melt is a relatively constant value across all compositions and is, on average, 0.27. The amphibole oxybarometer is applied to amphibole in mafic enclaves, cumulates, and basaltic tephra erupted from Shiveluch volcano in Kamchatka with measured Fe3+/FeTotal. An average Fe3+/Fe2+ amphibole-glass distribution coefficient for basalt is used to convert the Fe3+/FeTotal of amphibole in samples from Shiveluch to magmatic oxygen fugacity relative to NNO. The fO2 of primitive melts at the volcano is approximately NNO+2 and is faithfully recorded in amphibole from an amphibole-rich cumulate and the basaltic tephra. Apparently, higher fO2 recorded by amphibole in mafic enclaves likely results from partial dehydrogenation of amphibole during residence in a shallow andesite storage region. We identify three pulses of mafic magma recharge within two weeks of, a month before, and two to three months before the eruption and find that, at each of these times, the host andesite was recharged by at least two magmas at varying stages of differentiation. Application of the amphibole oxybarometer not only gives insight into magmatic fO2 but also potentially details of shallow magmatic processes.

Geochemistry & Geophysics↗

Catalyzed Nano-Framework Stablized High Density Reversible Hydrogen Storage Systems

A wide range of high capacity on-board rechargeable material candidates have exhibited non-ideal behavior related to irreversible hydrogen discharge / recharge behavior, and kinetic instability or retardation. This project addresses these issues by incorporating solvated and other forms of complex metal hydrides, with an emphasis on borohydrides, into nano-scale frameworks of low density, high surface area skeleton materials to stabilize, catalyze, and control desorption product formation associated with such complex metal hydrides. A variety of framework chemistries and hydride / framework combinations were investigated to make a relatively broad assessment of the method's potential. In this project, the hydride / framework interactions were tuned to decrease desorption temperatures for highly stable compounds or increase desorption temperatures for unstable high capacity compounds, and to influence desorption product formation for improved reversibility. First principle modeling was used to explore heterogeneous catalysis of hydride reversibility by modeling H 2 dissociation, hydrogen migration, and rehydrogenation. Atomic modeling also demonstrated enhanced NaTi(BH 4 ) 4 stabilization at nano-framework surfaces modified with multi-functional agents. Amine multi-functional agents were found to have more balanced interactions with nano-framework and hydride clusters than other functional groups investigated. Experimentation demonstrated that incorporation of Ca(BH 4 ) 2 and Mg(BH 4 ) 2 in aerogels enhanced hydride desorption kinetics. Carbon aerogels were identified as the most suitable nano-frameworks for hydride kinetic enhancement and high hydride loading. High loading of NaTi(BH 4 ) 4 ligand complex in SiO 2 aerogel was achieved and hydride stability was improved with the aerogel. Although improvements of desorption kinetics was observed, the incorporation of Ca(BH 4 ) 2 and Mg(BH 4 ) 2 in nano-frameworks did not improve their H 2 absorption due to the formation of stable alkaline earth B 12 H 12 intermediates upon rehydrogenation. This project primarily investigated the effect of nano-framework surface chemistry on hydride properties, while the effect of pore size is the focus area of other efforts (e.g., HRL, Sandia National Laboratories (SNL) etc.) within the Metal Hydride Center of Excellence (MHCoE). The projects were complementary in gaining an overall understanding of the influence of nano-frameworks on hydride behavior.

08 HYDROGEN↗

Long-Term Colloid Mobilization and Colloid-Facilitated Transport of Radionuclides in a Semi-Arid Vadose Zone

The main purpose of this project was to improve the fundamental mechanistic understanding and quantification of long-term colloid mobilization and colloid-facilitated transport of radionuclides in the vadose zone, with special emphasis on the semi-arid Hanford site. While we focused some of the experiments on hydrogeological and geochemical conditions of the Hanford site, many of our results apply to colloid and colloid-facilitated transport in general. Specific objectives were (1) to determine the mechanisms of colloid mobilization and colloid-facilitated radionuclide transport in undisturbed Hanford sediments under unsaturated flow, (2) to quantify in situ colloid mobilization and colloid-facilitated radionuclide transport from Hanford sediments under field conditions, and (3) to develop a field-scale conceptual and numerical model for colloid mobilization and transport at the Hanford vadose zone, and use that model to predict long-term colloid and colloid- facilitated radionuclide transport. To achieve these goals and objectives, we have used a combination of experimental, theoretical, and numerical methods at different spatial scales, ranging from microscopic investigations of single particle attachment and detachment to larger-scale field experiments using outdoor lysimeters at the Hanford site. Microscopic and single particle investigations provided fundamental insight into mechanisms of colloid interactions with the air-water interface. We could show that a moving air water interface (such as a moving water front during infiltration and drainage) is very effective in removing and mobilizing particles from a stationary surface. We further demonstrated that it is particularly the advancing air-water interface which is mainly responsible for colloid mobilization. Forces acting on the colloids calculated from theory corroborated our experimental results, and confirm that the detachment forces (surface tension forces) during the advancing air-water interface movement were stronger than during the receding movement. Theory indicates that, for hydrophilic colloids, the advancing interface movement generally exerts a stronger detachment force than the receding, except when the hysteresis of the colloid-air-water contact angle is small. These results of our study are particularly relevant for colloid mobilization and transport related to three process in the vadose zone at Hanford: (1) water infiltration into sediments during rainfall or snowmelt events, (2) groundwater fluctuations as caused by river stage fluctuations, and (3) steady-state, low-flow recharge in deep vadose zone sediments. Transient water flow, like during infiltration or groundwater level fluctuations, are most conducive for colloid mobilization, but even during steady-state, low-flow recharge, colloids can be mobile, although to a much lesser extent. The results of this project have led to a comprehensive and fundamental understanding of colloid transport and mobilization under unsaturated flow conditions at the Hanford site.

58 GEOSCIENCES↗

The CUNY Energy Institute Electrical Energy Storage Development for Grid Applications (Final report)

1. Project Objectives: The objectives of the project are to elucidate science issues intrinsic to high energy density electricity storage (battery) systems for smart-grid applications, research improvements in such systems to enable scale-up to grid-scale and demonstrate a large 200 kWh battery to facilitate transfer of the technology to industry. 2. Background: Complex and difficult to control interfacial phenomena are intrinsic to high energy density electrical energy storage systems, since they are typically operated far from equilibrium. One example of such phenomena is the formation of dendrites. Such dendrites occur on battery electrodes as they cycle, and can lead to internal short circuits, reducing cycle life. An improved understanding of the formation of dendrites and their control can improve the cycle life and safety of many energy storage systems, including rechargeable lithium and zinc batteries. Another area where improved understanding is desirable is the application of ionic liquids as electrolytes in energy storage systems. An ionic liquid is typically thought of as a material that is fully ionized (consisting only of anions and cations) and is fluid at or near room temperature. Some features of ionic liquids include a generally high thermal stability (up to 450°C), a high electrochemical window (up to 6 V) and relatively high intrinsic conductivities. Such features make them attractive as battery or capacitor electrolytes, and may enable batteries which are safer (due to the good thermal stability) and of much higher energy density (due to the higher voltage electrode materials which may be employed) than state of the art secondary (rechargeable) batteries. Of particular interest is the use of such liquids as electrolytes in metal air batteries, where energy densities on the order of 1-2,000 Wh/kg are possible; this is 5-10 times that of existing state of the art lithium battery technology. The Energy Institute has been engaged in the development of flow-assisted nickel zinc battery technology. This technology has the promise of enabling low-cost (<$250/kWh) energy storage, while overcoming the historical poor cycle-life drawback. To date, the results have been promising, with a cycle life of 1,500 cycles demonstrated in small laboratory cells – an improvement of approximately 400%. Prior state of the art nickel zinc batteries have only demonstrated about 400 cycles to failure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Radiochemically-Supported Microbial Communities: A Potential Mechanism for Biocolloid Production of Importance to Actinide Transport

Due to the legacy of Cold War nuclear weapons testing, the Nevada National Security Site (NNSS, formerly known as the Nevada Test Site (NTS)) contains millions of Curies of radioactive contamination. Presented here is a summary of the results of the first comprehensive study of subsurface microbial communities of radioactive and nonradioactive aquifers at this site. To achieve the objectives of this project, cooperative actions between the Desert Research Institute (DRI), the Nevada Field Office of the National Nuclear Security Administration (NNSA), the Underground Test Area Activity (UGTA), and contractors such as Navarro-Interra (NI), were required. Ultimately, fluids from 17 boreholes and two water-filled tunnels were sampled (sometimes on multiple occasions and from multiple depths) from the NNSS, the adjacent Nevada Test and Training Range (NTTR), and a reference hole in the Amargosa Valley near Death Valley. The sites sampled ranged from highly-radioactive nuclear device test cavities to uncontaminated perched and regional aquifers. Specific areas sampled included recharge, intermediate, and discharge zones of a 100,000-km2 internally-draining province, known as the Death Valley Regional Flow System (DVRFS), which encompasses the entirety of the NNSS/NTTR and surrounding areas. Specific geological features sampled included: West Pahute and Ranier Mesas (recharge zone), Yucca and Frenchman Flats (transitional zone), and the Western edge of the Amargosa Valley near Death Valley (discharge zone). The original overarching question underlying the proposal supporting this work was stated as: Can radiochemically-produced substrates support indigenous microbial communities and subsequently stimulate biocolloid formation that can affect radionuclides in NNSS subsurface nuclear test/detonation sites? Radioactive and non-radioactive groundwater samples were thus characterized for physical parameters, aqueous geochemistry, and microbial communities using both DNA- and cultivation-based tools in an effort to understand the drivers of microbial community structure (including radioactivity) and microbial interactions with select radionuclides and other factors across the range of habitats surveyed.

54 ENVIRONMENTAL SCIENCES↗

Manufacturing of Protected Lithium Electrodes for Advanced Lithium-Air, Lithium-Water & Lithium-Sulfur Batteries

The global demand for rechargeable batteries is large and growing rapidly. Assuming the adoption of electric vehicles continues to increase, the need for smaller, lighter, and less expensive batteries will become even more pressing. In this vein, PolyPlus Battery Company has developed ultra-light high performance batteries based on its proprietary protected lithium electrode (PLE) technology. The Company’s Lithium-Air and Lithium-Seawater batteries have already demonstrated world record performance (verified by third party testing), and we are developing advanced lithium-sulfur batteries which have the potential deliver high performance at low cost. In this program PolyPlus Battery Company teamed with Corning Incorporated to transition the PLE technology from bench top fabrication using manual tooling to a pre- commercial semi-automated pilot line. At the inception of this program PolyPlus worked with a Tier 1 battery manufacturing engineering firm to design and build the first-of-its-kind pilot line for PLE production. The pilot line was shipped and installed in Berkeley, California several months after the start of the program. PolyPlus spent the next two years working with and optimizing the pilot line and now produces all of its PLEs on this line. The optimization process successfully increased the yield, throughput, and quality of PLEs produced on the pilot line. The Corning team focused on fabrication and scale-up of the ceramic membranes that are key to the PLE technology. PolyPlus next demonstrated that it could take Corning membranes through the pilot line process to produce state-of-the-art protected lithium electrodes. In the latter part of the program the Corning team developed alternative membranes targeted for the large rechargeable battery market. PolyPlus is now in discussions with several potential customers for its advanced PLE-enabled batteries, and is building relationships and infrastructure for the transition into manufacturing. It is likely that the next step will be accomplished through a combination of joint venture partnering and licensing of the technology.

25 ENERGY STORAGE↗

Spark Plasma Sintering of Ultracapacitors

A solid-state ultracapacitor module to replace standard electrochemical batteries would achieve major performance gains and mass/volume reduction. This report summarizes a project to evaluate an alternative sintering process to produce a solid-state ultracapacitor to overcome the limitations of both the electrochemical batteries presently in use on spacecraft and of currently available electrochemical ultracapacitors. It will provide a robust energy storage device with higher reliability, wider working temperature range, longer lifetime, and less weight and volume than electrochemical batteries. As modern electronics decrease in size, more efficient and robust remote power is needed. Current state-of-the-art rechargeable batteries cannot be rapidly charged, contain harmful chemicals, and suffer from early wear-out mechanisms. Solid-state ultracapacitors are recyclable energy storage devices that offer the promise of higher power and a greater number of charge/discharge cycles than current rechargeable batteries. In addition, the theoretical energy density when compared to current electrochemical batteries indicates that a significant weight savings is possible. This is a project to develop a very high density solid-state ultracapacitor with giant permittivity and acceptable dielectric loss to overcome the energy-density barrier such that it will be a suitable replacement for batteries.

25 ENERGY STORAGE↗

Enabling Fast Charging: A Technology Gap Assessment

The transportation sector accounts for the largest percentage of energy use in the United States. Decreasing energy consumption across this sector, especially in commercial light duty transportation, is essential for the U.S. to gain energy independence. Recently, powertrain electrification with plug-in electric vehicles (PEVs) have gained traction as an alternative due to their inherent efficiency advantages compared to the traditional internal combustion engine vehicle (ICEV). Accounting for 500,000 vehicle on the road today, these PEVs will reduce oil imported into the U.S. by five billion gallons and save two billion dollars in fuel costs to consumers over their useful life. Though there are many different classes of PEV, the intent of this study is to focus on non-hybrid powertrains, or battery electric vehicles (BEVs). Despite rapid drops in cost within the BEV powertrain of over 4x in the last 10 years, the PEV market still only accounts for approximately 1% of new light duty vehicle sales annually. Though BEV powertrain costs are not quite at parity with the ICEV, another gap to wider adoption of BEVs that have been identified is the ability to refuel quickly, or to fast charge. Though the majority of recharging BEVs is done at home, having access to fast charge stations has a big impact on BEV utility from a consumer perspective. To address the fast charge barrier, charging at 350 kW, or extreme fast charging (XFC), has been proposed and will serve as the basis for discussion in this report. Studies have shown that in areas where drivers have access to 50 kW or 120 kW fast charge stations, annual electric vehicle miles traveled (eVMT) increased by over 25%, even in cases where fast charging was used for 1-5% of total charging events [1, 2]. Having access to these fast charge stations can help alleviate the “range anxiety” that is cited as a common reason for consumers to hesitate to buy a BEV. Though, to be truly competitive to the ICEV refueling experience, even higher power stations are necessary. These extreme fast charge stations (XFC) should be able to recharge a BEV in less than 10 minutes and provide approximately 175 additional miles of driving. However, this introduces a host of new challenges that need to be addressed. As a result, it is expected that packs designed to meet XFC will be significantly more expensive initially than BEVs optimized for range that can reach 140kW with current technology. From the battery cell to the power grid to which these 350 kW chargers are connected, this study will discuss the issues that need to be addressed at each level in order to implement a 350 kW charging network. Although this report is U.S.-focused, the findings should be applicable to other countries with mature automotive infrastructures.

25 ENERGY STORAGE↗

Characterize the Demand and Energy Characteristics of Residential Electric Vehicle Supply Equipment

The EV Project enrolled over 8,000 residential participants. These participants purchased or leased a Nissan Leaf or Chevrolet Volt. The EV Project provided and installed Blink Electric Vehicle Supply Equipment (EVSE), used to recharge their PEV, in exchange for their agreement to allow project analysts to evaluate data collected from charging their PEV at their residence and away from home. The power required to recharge a PEV can be a significant contributor to the electrical load a residence places on the electric grid. What insight can The EV Project data provide in characterizing this contribution in terms of power demand and energy consumption to assist electric utilities in PEV adoption planning?

33 ADVANCED PROPULSION SYSTEMS↗