High‐Resolution Receiver Function Imaging Across the Cascadia Subduction Zone Using a Dense Nodal Array

Abstract In the summer of 2017, we deployed 174 nodal geophones in the Cascadia Subduction Zone forearc with the specific aim of conducting a high‐resolution receiver function study. The dense trench perpendicular line in central Oregon with 500‐m spacing recorded continuous data for approximately 40 days. Our plate tectonic‐scale imaging results show the same features as previous broadband seismic deployments including the top of the subducting Juan de Fuca Plate, the slab Moho, and the continental Moho. Although our deployment was limited to around 40 days, the dense station spacing allowed us to image the shallow Oregon forearc in remarkable detail. In our shallow results, we image a continuous positive arrival that we interpret as the top of the accreted Siletzia terrane. We suggest that hybrid nodal/broadband deployments could be used in conjunction with offshore seismic studies to image subduction zones in unprecedented detail.

Ward, K. M.↗

Mid-latitude ionospheric irregularity spectral density as determined by ground-based GPS receiver networks

In this paper, we present a new technique to experimentally measure the spatial spectrum of ionospheric disturbances in the spatial scale regime of 40 – 200 km. This technique produces a 2-dimensional (2-D) spectrum for each time snapshot over two dense GPS receiver networks (GEONET in Japan and PBO in the Western U.S.). Because this technique created the spectrum from an instantaneous time snapshot, no assumptions are needed about the speed of ionospheric irregularities. We examine spectra from three days: one with an intense geomagnetic storm, one with significant lightning activity, and one quiet day. Radial slices along the 2-D spectra provide 1-dimensional spectra that can be fit to a power law to quantify the steepness of the fall-off in the spatial scale sizes. Continuous data of this type in a stationary location allows monitoring the variability in the 2-D spectrum over the course of a day and comparing between days, as shown here, or even over a year or many years. We find that the spectra are highly variable over the course of a day and between the two selected regions of Japan and the Western U.S. When strong travelling ionospheric disturbances (TIDs) are present, the 2-D spectra provide information about the direction of propagation of the TIDs. We compare the TID propagation direction with horizontal wind directions from the Horizontal Wind Model. Finally, TID direction is correlated with the horizontal wind direction on all days, strongly indicating that the primary source of the TIDs measured by this technique is tropospheric.

79 ASTRONOMY AND ASTROPHYSICS↗

Elevation angle alignment of quasi optical receiver mirrors of collective Thomson scattering diagnostic by sawtooth measurements

Localized measurements of the fast ion velocity distribution function and the plasma composition measurements are of significant interest for the fusion community. Collective Thomson scattering (CTS) diagnostics allow such measurements with spatial and temporal resolution. Localized measurements require a good alignment of the optical path in the transmission line. Monitoring the alignment during the experiment greatly benefits the confidence in the CTS measurements. An in situ technique for the assessment of the elevation angle alignment of the receiver is developed. Using the CTS diagnostic on TEXTOR without a source of probing radiation in discharges with sawtooth oscillations, an elevation angle misalignment of 0.9 Degree-Sign was found with an accuracy of 0.25 Degree-Sign .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose received by occupationally exposed workers at a nuclear medicine department

Personal Dose Equivalent (PDE) values were determined for occupational exposed workers (OEW) at the Nuclear Medicine Department (NMD) of 'Instituto Nacional de Cancerologia' (INCan), Mexico, using TLD-100 thermoluminescent dosemeters. OEW at NMD, INCan make use of radiopharmaceuticals for diagnosis and treatment of diseases. Radionuclides associated to a pharmaceutical compound used at this Department are {sup 131}I, {sup 18}F, {sup 68}Ga, {sup 99m}Tc, {sup 111}In and {sup 11}C with main gamma emission energies between 140 and 511 keV. Dosemeter calibration was performed at the metrology department of 'Instituto Nacional de Investigaciones Nucleares' (ININ), Mexico. Every occupational worker used dark containers with three dosimeters which were replaced monthly for a total of 5 periods. Additionally, control dosemeters were also placed at a site free of radioactive sources in order to determine the background radiation. Results were adjusted to find PDE/day and estimating annual PDE values in the range between 2 mSv (background) and 9 mSv. The mean annual value is 3.51 mSv and the standard deviation SD is 0.78 mSv. Four of the 16 OEW received annual doses higher than the average +1 SD (4.29 mSv). Results depend on OEW daily activities and were consistent for each OEW for the 5 studied periods as well as with PDE values reported by the firm that performs the monthly service. All obtained values are well within the established annual OEW dose limit stated in the {sup R}eglamento General de Seguridad Radiologica{sup ,} Mexico (50 mSv), as well as within the lower limit recommended by the 'International Commission on Radiation Protection' (ICRP), report no.60 (20 mSv). These results verify the adequate compliance of the NMD at INCan, Mexico with the norms given by the national regulatory commission.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multi-fidelity uncertainty quantification strategies for large-scale multiphysics applications: PSAAP II particle-based solar energy receiver

The study of complex systems is often based on computationally intensive, high-fidelity, simulations. To build confidence or improve the prediction accuracy of such simulations, the impact of uncertainties in model inputs, or even the structure of the models, on the quantities of interest must be measured. This, however, requires a computational budget that is a possibly large multiple of the cost of a single simulation, and thus may become infeasible for expensive simulation models featuring a large number of uncertain inputs and highly non-linear behavior. Therefore, this work explores multi-fidelity strategies to accelerate the estimation of the effect of uncertainties. The main idea behind multi-fidelity methods is to utilize cheaper, lower-fidelity models – than the intended high-fidelity, expensive model of the problem – to generate a baseline solution that together with relatively small number of high-fidelity simulations can lead to accurate predictions. The methods are briefly presented, and their performance assessed on an irradiated particle-laden turbulent flow case related to Stanford’s PSAAP II particle-based solar energy receiver.

Physics↗

LACK OF INFLATED RADII FOR KEPLER GIANT PLANET CANDIDATES RECEIVING MODEST STELLAR IRRADIATION

The most irradiated transiting hot Jupiters are characterized by anomalously inflated radii, sometimes exceeding Jupiter's size by more than 60%. While different theoretical explanations have been applied, none of them provide a universal resolution to this observation, despite significant progress in the past years. We refine the photometric transit light curve analysis of 115 Kepler giant planet candidates based on public Q0-Q2 photometry. We find that 14% of them are likely false positives, based on their secondary eclipse depth. We report on planet radii versus stellar flux. We find an increase in planet radii with increased stellar irradiation for the Kepler giant planet candidates, in good agreement with existing hot Jupiter systems. We find that in the case of modest irradiation received from the stellar host, giant planets do not have inflated radii, and appear to have radii independent of the host star incident flux. This finding suggests that the physical mechanisms inflating hot Jupiters become ineffective below a given orbit-averaged stellar irradiation level of {approx}2 Multiplication-Sign 10{sup 8} erg s{sup -1} cm{sup -2}.

79 ASTRONOMY AND ASTROPHYSICS↗

QTIA, a 2.5 or 10 Gbps 4-channel array optical receiver ASIC in a 65 nm CMOS technology

Here, the Quad transimpedance and limiting amplifier (QTIA) is a 4-channel array optical receiver ASIC, developed using a 65 nm CMOS process. It is configurable between the bit rate of 2.56 Gbps and 10 Gbps per channel. QTIA offers careful matching to both GaAs and InGaAs photodiodes. At this R&D stage, each channel has a different biasing scheme to the photodiode for optimal coupling. A charge pump is implemented in one channel to provide a higher reverse bias voltage, which is especially important to mitigate radiation effects on the photodiodes. The circuit functions of QTIA successfully passed the lab tests with GaAs photodiodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crustal and uppermost mantle structure in the Middle East: assessing constraints provided by jointly modelling Ps and Sp receiver functions and Rayleigh wave group velocity dispersion curves

Seismic velocity models are found, along with uncertainty estimates, for 11 sites in the Middle East by jointly modelling Ps and Sp receiver functions and surface (Rayleigh) wave group velocity dispersion. The approach performs a search for models that satisfy goodness-of-fit criteria guided by a variant of simulated annealing and uses statistical tools to assess these products of searches. These tools, a parameter correlation matrix and marginal posterior probability density (PPD) function, allow us to evaluate quantitatively the constraints that each data type imposes on model parameters and to identify portions of each model that are well-constrained relative to other portions. This joint modelling technique, which we call ‘multi-objective optimization for seismology’, does not require a good starting solution, although such a model can be incorporated easily, if available, and can reduce the computation time significantly. Applying the process described above to broadband seismic data reveals that crustal thickness varies from 15 km beneath Djibouti (station ATD) to 45 km beneath Saudi Arabia (station RAYN). A pronounced low velocity zone for both Vp and Vs is present at a depth of ~12 km beneath station KIV located in northern part of greater Caucasus, which may be due to the presence of a relatively young volcano. Similarly, we also noticed a 6-km-thick low velocity zone for Vp beginning at 20 km depth beneath seismic station AGIN, on the Anatolian plateau, while positive velocity gradients prevail elsewhere in eastern Turkey. Beneath station CSS, located in Cyprus, an anomalously slow layer is found in the uppermost mantle, which may indicate the presence of altered lithospheric material. Crustal P- and S-wave velocities beneath station D2, located in the northeastern portion of central Zagros, range between 5.2–6.2 and 3.2–3.8 km s -1 , respectively. Finally, in Oman, we find a Moho depth of 34.0 ± 1.0 km and 25.0 ± 1.0 to 30.0 ± 1.0 km beneath stations S02 and S04, respectively.

58 GEOSCIENCES↗

Accelerated Over-The-Air Neural Receiver Training Using Self-Contrastive Learning

Self-contrastive learning (SCL), a self-supervised learning method, has been shown to improve image and signal classifier accuracies and reduce the training time for neural communications receivers. In particular, prior work has shown that SCL applied as a pre-training step can improve simulated performance of OFDM in 3GPP TDL channel models by reducing the training time of the downstream classification task (demodulation and demapping). In this work a practical implementation demonstrating SCL pre-training using software defined radios (SDRs) is proposed.

Cooke, Corey [ORNL] (ORCID:0000000234263672)↗

A Pixel Pitch-Matched Ultrasound Receiver for 3-D Photoacoustic Imaging With Integrated Delta-Sigma Beamformer in 28-nm UTBB FD-SOI

This study presents a pixel pitch-matched readout chip for 3-D photoacoustic (PA) imaging, featuring a dedicated signal conditioning and delta-sigma modulation integrated within a pixel area of 250 μm by 250 μm. The proof-of-concept receiver was implemented in an STMicroelectronics's 28-nm Fully Depleted Silicon On Insulator technology, and interfaces to a 4 × 4 subarray of capacitive micromachined ultrasound transducers (CMUTs). The front-end signal conditioning in each pixel employs a coarse/fine gain tuning architecture to fulfill the 90-dB dynamic range requirement of the application. The employed delta-sigma beamforming architecture obviates the need for area-consuming Nyquist ADCs and thereby enables an efficient in-pixel A/D conversion. The per-pixel switched-capacitor ΔΣ modulator leverages slewing-dominated and area-optimized inverter-based amplifiers. It occupies only 1/4th of the pixel, and its area compares favorably with state-of-the-art designs that offer the same SNR and bandwidth. The modulator's measured peak signal-to-noise-and-distortion ratio is 59.9 dB for a 10-MHz input bandwidth, and it consumes 6.65 mW from a 1V supply. The overall subarray beamforming approach improves the area per channel by 7.4 times and the single-channel SNR by 8 dB compared to prior art with similar delay resolution and power dissipation. Finally, the functionality of the designed chip was evaluated within a PA imaging experiment, employing a flip-chip bonded 2-D CMUT array.

3-D photoacoustic (PA) imaging↗

Numerical Study of Solar Receiver Tube With Modified Surface Roughness for Enhanced and Selective Absorptivity in Concentrated Solar Power Tower

Abstract Concentrated solar power (CSP) is a reliable renewable energy source that is progressively lowering its cost of energy. However, the heat loss due to reflected and emitted radiation hinders the maximum achievable thermal efficiency for solar receiver tubes on the solar tower. Current solar selective coatings cannot withstand the high temperatures that come with state-of-the-art CSP towers often needing to be recoated soon after initial operation. We intend to use Inconel 718 with different additive manufacturing (AM) practices to construct surfaces that allow for more light-trapping to occur. By adjusting printing parameters, we can tailor a surface to allow for more absorption while diminishing emitted radiation heat loss. By using COMSOL Multiphysics, we can generate these theoretical surfaces to emulate a printed surface, and using the coupled Multiphysics we can simulate how the surface dictates radiation properties. Our results show that by having a rougher surface we can enhance the absorptivity of Inconel 718 (IN718) by 38.8%. We expect this work to transform how solar absorber tubes are manufactured without using selective coatings and supplement the US Department of Energy (DOE) 2030 SunShot Initiative.

14 SOLAR ENERGY↗

Optical Flow Diagnostics of Counter Fluidization of Gravity-Driven Moving Packed Bed for a CSP Receiver Section Featuring Staggered Array of Cylindrical Pins

Particle fluidized beds have the potential to improve the efficiency of heat transfer in concentrated solar receiver furnace for use in next generation concentrated solar power (CSP) plants. This study presents an experimental investigation on the flow characterization of vertically downward moving packed bed with counter fluidization through an array of jets. To control the bubble size and its distribution in the bubbling fluidized bed, an array of cylindrical pin fins was arranged uniformly across the test article. The flow visualization was performed on the surface of transparent glass coated with electrically conductive materials for electrostatic dissipation purposes. The image acquisition was carried out via high-speed camera at a frequency of ~ 1kHz. The acquired images were analyzed in pairs with the help of a modern optical flow algorithm capable of calculating the movement of dense particle flow in the fluidized bed by tracking the light intensity of each predefined window of the frames. A comparison of fluidized beds with plane and pin-finned channels revealed distinct bubble behavior. Pin-finned channels were found to produce a larger number of small-sized bubbles, while plane channels generated fewer but larger bubbles at any given instant. The presence of pin fins was observed to reduce bubble size by preventing bubble merging and splitting larger bubbles when they encountered a pin.

concentrating solar power↗

Development of a specific methodology to assess suitable sites to receive a repository for L/ILW waste in the Portuguese territory

Portugal does not have nuclear power plants but records an increasing production of radioactive waste from medical, industrial and research applications of radioactive materials in the form of sealed and unsealed sources; the country totals include also the spent fuel of one nuclear reactor for research purposes. Since radioactive waste management policies and practices in Portugal will have to comply with the Council Directive 2011/70/Euratom and the IAEA Joint Convention, the search for scientific and technological solutions to deal with radioactive wastes produced in the country started some years ago. The research carried out recently under the scope of a national funded project (KADRWaste, PTDC/CTEGEX/ 82678/2006) represents a firm step in this commitment. Indeed, the transfer of methodologies tested and validated in this project allowed for improvement to a procedure to assess suitable sites to receive a near-surface repository for 'Low and Intermediate Level Waste, Short Live and Long Live' (LILWSL, LL) wastes in Portugal mainland. Although the main stages of the procedure can be of universal usage, details were designed according to the intrinsic geological, geomorphic and meteorological features of previously selected target-areas. All the requirements exhaustively listed in many reports of the IAEA were fulfilled and, in addition, the application of mineralogical, geochemical and textural criteria is strongly advised. The proposed procedure is based on a 5 key-steps approach preceded by clarification of the boundary conditions to be imposed, which are crucial to the inventory of various compulsory technical requirements. This analysis requires the adoption of stringent criteria, many of them of multidisciplinary nature, including tests of vulnerability and assessment of uncertainty, besides the environmental impact risk. As a result, priority targets that are not excluded will integrate different classes and, depending on the existing knowledge, it will be possible to select locations suitable for the repository installation, taking into account also the political, social and administrative dimensions behind this decision. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

As-Received, Ozone Cleaned and Ar+ Sputtered Surfaces of Hafnium Oxide Grown by Atomic Layer Deposition and Studied by XPS

In this study, X-ray photoelectron spectroscopy (XPS) characterization was performed on 47 nm thick hafnium oxide (HfO{sub 2}) films grown by atomic layer deposition using TEMA-Hf/H{sub 2}O at 250 C substrate temperature. HfO{sub 2} is currently being studied as a possible replacement for Silicon Oxide (SiO{sub 2}) as a gate dielectric in electronics transistors. XPS spectra were collected on a Physical Electronics Quantum 2000 Scanning ESCA Microprobe using a monochromatic Al K{sub a} X-ray (1486.7 eV) excitation source. The sample was analyzed under the following conditions: as received, after UV irradiation for five minutes, and after sputter cleaning with 2 kV Ar{sup +} ions for 180 seconds. Survey scans showed carbon, oxygen, and hafnium as the major species in the film, while the only minor species of argon and carbide was detected after sputtering. Adventitious carbon initially composed approximately 18.6 AT% of the surface, but after UV cleaning it was reduced to 2.4 AT%. This demonstrated that that the majority of carbon was due to adventitious carbon. However, after 2 kV Ar{sup +} sputtering there was still only trace amounts of carbon at {approx}1 AT%, Some of this trace carbon is now in the form of a carbide due to the interaction with Ar{sup +} used for sputter cleaning. Furthermore, the stoiciometric ratio of oxygen and hafnium is consistent with a high quality HfO{sub 2} film.

36 MATERIALS SCIENCE↗

Sci—Thur AM: YIS - 02: Radiogenomic Modeling of Normal Tissue Toxicities in Prostate Cancer Patients Receiving Hypofractionated Radiotherapy

Inter-patient radiation sensitivity variability has recently been shown to have a genetic component. This genetic component may play a key role in explaining the fluctuating rates of radiation-induced toxicities (RITs). Single nucleotide polymorphisms (SNPs) have thus far yielded inconsistent results in delineating RITs while copy number variations (CNVs) have not yet been investigated for such purposes. We explore a radiogenomic modeling approach to investigate the association of CNVs and SNPs, along with clinical and dosimetric variables, in radiation induced rectal bleeding (RB) and erectile dysfunction (ED) in prostate cancer patients treated with curative hypofractionated irradiation. A cohort of 62 prostate cancer patients who underwent hypofractionated radiotherapy (66 Gy in 22 fractions) between 2002 to 2010 were retrospectively genotyped for CNV and SNP rs5489 in the xrcc1 DNA repair gene. Late toxicity rates for RB grade 2 and 3 and grade 3 alone were 29.0% and 12.9%, respectively. ED toxicity was found to be 62.9%. Radiogenomic model performance was evaluated using receiver operating characteristic area under the curve (AUC) and resampling by cross-validation. Binary variables were evaluated using Chi-squared contingency table analysis and multivariate models by Spearman's rank correlation coefficient (rs). Ten patients were found to have three copies of xrcc1 CNV (RB: χ{sup 2}=14.6, p<0.001 and ED: χ{sup 2}=4.88, p=0.0272) and twelve had heterozygous rs25489 SNP (RB: χ{sup 2}=0.278, p=0.599 and ED: χ{sup 2}=0.112, p=0.732). Radiogenomic modeling yielded significant, cross-validated NTCP models for RB (AUC=0.665) and ED (AUC=0.754). These results indicate that CNVs may be potential predictive biomarkers of both late ED and RB.

60 APPLIED LIFE SCIENCES↗

SU-E-T-209: Comparison of Plan Quality Between Arm Avoidance (AA) Vs. Non Arm Avoidance VMAT Planning Techniques for Breast Cancer Patients with Bilateral Implant Reconstructions Receiving Postmastectomy Radiation

Purpose: Breast cancer patients with bilateral implant reconstructions who require postmastectomy radiotherapy can pose unique treatment planning challenges. The use of VMAT may provide advantages over conventional tangent or multi-beam IMRT techniques. Moreover, daily setup uncertainly of the arm position, however, could have significant impact on accurate dose delivery. This study compares the plan qualities between non-AA and AA VMAT techniques. Methods: Three breast cancer patients receiving left chest wall and regional nodal irradiation with bilateral implant reconstructions were studied. PTV included chest wall and IMNs (PTV-CW), and supraclavicular and axillary lymph nodes (PTV-SCV). For each patient, one non-AA VMAT plan (VMAT-S) with 4 partial arcs encompassing the ipsilateral arm and three AA VMAT plans where no arcs were entering or existing through the ipsilateral arm were generated. VMAT-AA1 uses 2 arcs for PTV-CW and 2 arcs for PTV-SCV. VMAT-AA2 used two static fields for PTV-SCV with 2 arcs for PTV-CW. VMAT-AA3 used 2 narrow arcs for PTV-CW and 2 long arcs for all PTVs. Prescription dose (PD) was 50 Gy (25 fractions). All plans were normalized to have 95% of PD to 95 % of PTV. PTV dose inhomogeneity and dose to the heart, left lung, right thyroid dose and left humerus were evaluated. Results: For VMAT-S, VMAT-AA1, VMAT-AA2 and VMAT-AA3, respectively, the average and standard deviation (in Gy unless specified otherwise) of PTV D05 are 54.7±0.9, 55.9±0.4, 56.7±0.7 and 55.7±0.4; mean Heart dose: 7.1±0.7, 7.2±0.8, 7.3±0.9 and 6.9±1.0; left lung V20Gy (in %): 28.1±1.0, 28.8+2.2, 32.2±4.1 and 27.8±2.0; mean right thyroid dose: 8.1±0.6, 5.1±2.1, 2.1±0.4 and 5.0±2.0; mean left humerus dose: 20.0±4.4,15.6±4.4, 15.2±8.2 and 15.3±4.6. Conclusion: AA VMAT can produce acceptable clinical plans while eliminating dosimetric impact related to arm setup uncertainty. These data require validation in larger planning studies prior to routine clinical implantation.

60 APPLIED LIFE SCIENCES↗

An Experimental Cell for a Radio Light Receiver

The problem of creating a receiver for incoherent microwave radiation from sources realized on the basis of ultra-wideband oscillators of chaotic oscillations and objects and surfaces “illuminated” by these sources has been considered. The structure of the device is proposed, the experimental sample is described, and its ability to register sources of incoherent microwave radiation with an integrated output power of ~2 mW at a distance of more than 100 m is shown.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Meiotic susceptibility for induction of sperm with chromosomal aberrations in patients receiving combination chemotherapy for Hodgkin lymphoma

Improvements in survival rates with gonad-sparing protocols for childhood and adolescence cancer have increased the optimism of survivors to become parents after treatment. Findings in rodents indicate that chromosomal aberrations can be induced in male germ cells by genotoxic exposures and transmitted to offspring and future generations with effects on development, fertility and health. Thus, there is a need for effective technologies to identify human sperm carrying chromosomal aberrations to assess the germ-line risks, especially for cancer survivors who have received genotoxic therapies. The time-dependent changes in the burden of sperm carrying structural chromosomal aberrations were assessed for the first time in a cancer setting, using the AM8 sperm FISH protocol which simultaneously detects abnormalities in chromosomal structure and number in sperm. Nine Hodgkin lymphoma (HL) patients provided 20 semen samples before, during, and after NOVP therapy (Novantrone, Oncovin, Velban and Prednisone) and radiation therapy that produced scattered gonadal doses from <0.05 to 0.6 Gy. Late meiosis was found to be the most sensitive to NOVP treatment for the production of sperm with chromosomal abnormalities, both in structure and number. Earlier stages of spermatogenesis were less sensitive and there was no evidence that therapy-exposed stem cells resulted in increased frequencies of sperm with abnormalities in chromosomal structure or number. This indicates that NOVP therapy may increase the risks for paternal transmission of chromosomal structural aberrations for sperm produced 32 to 45 days after a treatment with these drugs and implies that there are no excess risks for pregnancies conceived more than 6 months after this therapy. This clinical evaluation of the AM8 sperm FISH protocol indicates that it is a promising tool for assessing an individual’s burden of sperm carrying chromosomal structural aberrations as well as aneuploidies after cancer therapy, with broad applications in other clinical and environmental situations that may pose aneugenic or clastogenic risks to human spermatogenesis.

60 APPLIED LIFE SCIENCES↗