Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “parameter studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Enhancement of the superconducting gap by nesting in CaKFe 4 As 4 : A new high temperature superconductor

We use high resolution angle resolved photoemission spectroscopy and density functional theory with measured crystal structure parameters to study the electronic properties of CaKFe 4 As 4 . In contrast to the related CaFe 2 As 2 compounds, CaKFe 4 As 4 has a high T c of 35 K at stochiometric composition. This presents a unique opportunity to study the properties of high temperature superconductivity in the iron arsenides in the absence of doping or substitution. The Fermi surface consists of several hole and electron pockets that have a range of diameters. We find that the values of the superconducting gap are nearly isotropic (within the explored portions of the Brillouin zone), but are significantly different for each of the Fermi surface (FS) sheets. Most importantly, we find that the momentum dependence of the gap magnitude plotted across the entire Brillouin zone displays a strong deviation from the simple cos( k x )cos( k y ) functional form of the gap function, proposed by the scenario of Cooper pairing driven by a short range antiferromagnetic exchange interaction. Instead, the maximum value of the gap is observed on FS sheets that are closest to the ideal nesting condition, in contrast to previous observations in other ferropnictides. Finally, these results provide strong support for the multiband character of superconductivity in CaKFe 4 As 4 , in which Cooper pairing forms on the electron and the hole bands interacting via a dominant interband repulsive interaction, enhanced by band nesting.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Graphene-Based Interconnect Exploration for Large SRAM Caches for Ultrascaled Technology Nodes

Graphene-based interconnects are considered promising replacements for traditional copper (Cu) interconnect due to their great electric properties. In this article, an interconnect-memory co- design framework is developed to efficiently optimize various graphene-based interconnect technologies. Four interconnect materials and heterogeneous design schemes are benchmarked against their traditional Cu counterparts to optimize large cache-level SRAM performance in terms of delay and energy per access, energy-delay product (EDP), and energy-delay-area product (EDAP). Here, a large design space exploration is performed based on realistic subarray design and device technology. Various interconnect- and array-level design parameters are studied to quantify the true potential of graphene-based wires for optimal memory performance.

42 ENGINEERING↗

Water use of co‐occurring loblolly ( Pinus taeda ) and shortleaf ( Pinus echinata ) in a loblolly pine plantation in the Piedmont

Abstract Measuring water use in co‐occurring loblolly pine (Pinus taedaL.) and shortleaf pine (Pinus echinataMill.) enhances our understanding of their competitive water use and aids in refining watershed water budget model parameters. This study was conducted in a 12‐ha forested headwater catchment in the Piedmont of North Carolina, southeastern U.S., from 2018 to 2019 (pre‐thinning) to 2020 (post‐thinning). Sap flux density (J s ), species‐level transpiration (T s ), and watershed‐level transpiration (T w ) were quantified. Water use efficiency (WUE) in loblolly and shortleaf pines was compared, alongside an investigation into how both species'J s andT s responded to atmospheric vapor pressure deficit (VPD). Loblolly pine had 19%–36% higherJ s than shortleaf pine. DailyT s for loblolly pine ranged from 15.0 to 29.0 L/day whileT s in shortleaf pine ranged from 3.0 to 6.8 L/day. TheT s was significantly higher in loblolly pine when compared to shortleaf pine likely due to higher canopy position and higher growth rates of the former. WUE, defined by annual tree biomass growth per tree water use, was not significantly different between the two. DailyJ s andT s in both species responded nonlinearly to VPD, with loblolly pine being more sensitive and variable. Species‐specific water use should be considered when quantifyingT w and developing reliable models to predict the effects of forest management practices on water resources.

Engineering↗

Application of PHADEC method for the decontamination of radioactive steam piping components

The dismantling of nuclear plants is a complex activity that originates often a large quantity of radioactive contaminated residue. In this paper the attention was focused on the PHADEC (Phosphoric Acid Decontamination) plant adopted for the clearance of Caorso NPP (in Italy) metallic systems and components contaminated by Co{sup 60} (produced by the neutron capture in the iron materials), like the main steam lines, moisture separator of the turbine buildings, etc.. The PHADEC plant consists in a chemical off line treatment: the crud, deposited along the steam piping during life plant as an example, is removed by means of acid attacks in ponds coupled to a high pressure water washing. Due to the fact that the removed contaminated layers, essentially, iron oxides of various chemical composition, depend on components geometry, type of contamination and time of treatment in the PHADEC plant, it becomes of meaningful importance to suggest a procedure capable to improve the control of the PHADEC process parameters. This study aimed thus at the prediction and optimization of the mentioned treatment time in order to improve the efficiency of the plant itself and to achieve, in turn, the minimization of produced wastes. To the purpose an experimental campaign was carried out by analysing several samples, i.e. taken along the main steam piping line. Smear tests as well as metallographic analyses were carried out in order to determine respectively the radioactivity distribution and the crud composition on the inner surface of the components. Moreover the radioactivity in the crud thickness was measured. These values allowed finally to correlate the residence time in the acid attack ponds to the level of the achieved decontamination. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Volumetric quantification of lung nodules in CT with iterative reconstruction (ASiR and MBIR)

Purpose: Volume quantifications of lung nodules with multidetector computed tomography (CT) images provide useful information for monitoring nodule developments. The accuracy and precision of the volume quantification, however, can be impacted by imaging and reconstruction parameters. This study aimed to investigate the impact of iterative reconstruction algorithms on the accuracy and precision of volume quantification with dose and slice thickness as additional variables.Methods: Repeated CT images were acquired from an anthropomorphic chest phantom with synthetic nodules (9.5 and 4.8 mm) at six dose levels, and reconstructed with three reconstruction algorithms [filtered backprojection (FBP), adaptive statistical iterative reconstruction (ASiR), and model based iterative reconstruction (MBIR)] into three slice thicknesses. The nodule volumes were measured with two clinical software (A: Lung VCAR, B: iNtuition), and analyzed for accuracy and precision.Results: Precision was found to be generally comparable between FBP and iterative reconstruction with no statistically significant difference noted for different dose levels, slice thickness, and segmentation software. Accuracy was found to be more variable. For large nodules, the accuracy was significantly different between ASiR and FBP for all slice thicknesses with both software, and significantly different between MBIR and FBP for 0.625 mm slice thickness with Software A and for all slice thicknesses with Software B. For small nodules, the accuracy was more similar between FBP and iterative reconstruction, with the exception of ASIR vs FBP at 1.25 mm with Software A and MBIR vs FBP at 0.625 mm with Software A.Conclusions: The systematic difference between the accuracy of FBP and iterative reconstructions highlights the importance of extending current segmentation software to accommodate the image characteristics of iterative reconstructions. In addition, a calibration process may help reduce the dependency of accuracy on reconstruction algorithms, such that volumes quantified from scans of different reconstruction algorithms can be compared. The little difference found between the precision of FBP and iterative reconstructions could be a result of both iterative reconstruction's diminished noise reduction at the edge of the nodules as well as the loss of resolution at high noise levels with iterative reconstruction. The findings do not rule out potential advantage of IR that might be evident in a study that uses a larger number of nodules or repeated scans.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-247: Multi-Leaf Collimator Model Adjustments Improve Small Field Dosimetry in VMAT Plans

Purpose: The Elekta beam modulator linac employs a 4-mm micro multileaf collimator (MLC) backed by a fixed jaw. Out-of-field dose discrepancies between treatment planning system (TPS) calculations and output water phantom measurements are caused by the 1-mm leaf gap required for all moving MLCs in a VMAT arc. In this study, MLC parameters are optimized to improve TPS out-of-field dose approximations. Methods: Static 2.4 cm square fields were created with a 1-mm leaf gap for MLCs that would normally park behind the jaw. Doses in the open field and leaf gap were measured with an A16 micro ion chamber and EDR2 film for comparison with corresponding point doses in the Pinnacle TPS. The MLC offset table and tip radius were adjusted until TPS point doses agreed with photon measurements. Improvements to the beam models were tested using static arcs consisting of square fields ranging from 1.6 to 14.0 cm, with 45° collimator rotation, and 1-mm leaf gap to replicate VMAT conditions. Gamma values for the 3-mm distance, 3% dose difference criteria were evaluated using standard QA procedures with a cylindrical detector array. Results: The best agreement in point doses within the leaf gap and open field was achieved by offsetting the default rounded leaf end table by 0.1 cm and adjusting the leaf tip radius to 13 cm. Improvements in TPS models for 6 and 10 MV photon beams were more significant for smaller field sizes 3.6 cm or less where the initial gamma factors progressively increased as field size decreased, i.e. for a 1.6cm field size, the Gamma increased from 56.1% to 98.8%. Conclusion: The MLC optimization techniques developed will achieve greater dosimetric accuracy in small field VMAT treatment plans for fixed jaw linear accelerators. Accurate predictions of dose to organs at risk may reduce adverse effects of radiotherapy.

07 ISOTOPE AND RADIATION SOURCES↗

Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging

Purpose: The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-ray detector based on a silicon (Si) strip sensor used in an edge-on geometry with an application specific integrated circuit to record the number of x-rays and their energies at high flux and fast frame rates. The investigated detector was integrated with a dedicated breast spectral computed tomography (CT) system to make use of the detector's high spatial and energy resolution and low noise performance under conditions suitable for clinical breast imaging. The aim of this article is to investigate the intrinsic characteristics of the detector, in terms of maximum output count rate, spatial and energy resolution, and noise performance of the imaging system. Methods: The maximum output count rate was obtained with a 50 W x-ray tube with a maximum continuous output of 50 kVp at 1.0 mA. A{sup 109}Cd source, with a characteristic x-ray peak at 22 keV from Ag, was used to measure the energy resolution of the detector. The axial plane modulation transfer function (MTF) was measured using a 67 μm diameter tungsten wire. The two-dimensional (2D) noise power spectrum (NPS) was measured using flat field images and noise equivalent quanta (NEQ) were calculated using the MTF and NPS results. The image quality parameters were studied as a function of various radiation doses and reconstruction filters. The one-dimensional (1D) NPS was used to investigate the effect of electronic noise elimination by varying the minimum energy threshold. Results: A maximum output count rate of 100 million counts per second per square millimeter (cps/mm{sup 2}) has been obtained (1 million cps per 100 × 100 μm pixel). The electrical noise floor was less than 4 keV. The energy resolution measured with the 22 keV photons from a {sup 109}Cd source was less than 9%. A reduction of image noise was shown in all the spatial frequencies in 1D NPS as a result of the elimination of the electronic noise. The spatial resolution was measured just above 5 line pairs per mm (lp/mm) where 10% of MTF corresponded to 5.4 mm{sup −1}. The 2D NPS and NEQ shows a low noise floor and a linear dependence on dose. The reconstruction filter choice affected both of the MTF and NPS results, but had a weak effect on the NEQ. Conclusions: The prototype energy resolved photon counting Si strip detector can offer superior imaging performance for dedicated breast CT as compared to a conventional energy-integrating detector due to its high output count rate, high spatial and energy resolution, and low noise characteristics, which are essential characteristics for spectral breast CT imaging.

60 APPLIED LIFE SCIENCES↗

Thermal regulation of tightly packed solid-state photodetectors in a 1 mm{sup 3} resolution clinical PET system

Purpose: Silicon photodetectors are of significant interest for use in positron emission tomography (PET) systems due to their compact size, insensitivity to magnetic fields, and high quantum efficiency. However, one of their main disadvantages is fluctuations in temperature cause strong shifts in gain of the devices. PET system designs with high photodetector density suffer both increased thermal density and constrained options for thermally regulating the devices. This paper proposes a method of thermally regulating densely packed silicon photodetectors in the context of a 1 mm{sup 3} resolution, high-sensitivity PET camera dedicated to breast imaging. Methods: The PET camera under construction consists of 2304 units, each containing two 8 × 8 arrays of 1 mm{sup 3} LYSO crystals coupled to two position sensitive avalanche photodiodes (PSAPD). A subsection of the proposed camera with 512 PSAPDs has been constructed. The proposed thermal regulation design uses water-cooled heat sinks, thermoelectric elements, and thermistors to measure and regulate the temperature of the PSAPDs in a novel manner. Active cooling elements, placed at the edge of the detector stack due to limited access, are controlled based on collective leakage current and temperature measurements in order to keep all the PSAPDs at a consistent temperature. This thermal regulation design is characterized for the temperature profile across the camera and for the time required for cooling changes to propagate across the camera. These properties guide the implementation of a software-based, cascaded proportional-integral-derivative control loop that controls the current through the Peltier elements by monitoring thermistor temperature and leakage current. The stability of leakage current, temperature within the system using this control loop is tested over a period of 14 h. The energy resolution is then measured over a period of 8.66 h. Finally, the consistency of PSAPD gain between independent operations of the camera over 10 days is tested. Results: The PET camera maintains a temperature of 18.00 ± 0.05 °C over the course of 12 h while the ambient temperature varied 0.61 °C, from 22.83 to 23.44 °C. The 511 keV photopeak energy resolution over a period of 8.66 h is measured to be 11.3% FWHM with a maximum photopeak fluctuation of 4 keV. Between measurements of PSAPD gain separated by at least 2 day, the maximum photopeak shift was 6 keV. Conclusions: The proposed thermal regulation scheme for tightly packed silicon photodetectors provides for stable operation of the constructed subsection of a PET camera over long durations of time. The energy resolution of the system is not degraded despite shifts in ambient temperature and photodetector heat generation. The thermal regulation scheme also provides a consistent operating environment between separate runs of the camera over different days. Inter-run consistency allows for reuse of system calibration parameters from study to study, reducing the time required to calibrate the system and hence to obtain a reconstructed image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Note: Study of the electron transport parameters used in PENELOPE for the Monte Carlo simulation of Linac targets

Purpose: The Monte Carlo simulation of electron transport in Linac targets using the condensed history technique is known to be problematic owing to a potential dependence of absorbed dose distributions on the electron step length. In the PENELOPE code, the step length is partially determined by the transport parameters C1 and C2. The authors have investigated the effect on the absorbed dose distribution of the values given to these parameters in the target. Methods: A monoenergetic 6.26 MeV electron pencil beam from a point source was simulated impinging normally on a cylindrical tungsten target. Electrons leaving the tungsten were discarded. Radial absorbed dose profiles were obtained at 1.5 cm of depth in a water phantom located at 100 cm for values of C1 and C2 in the target both equal to 0.1, 0.01, or 0.001. A detailed simulation case was also considered and taken as the reference. Additionally, lateral dose profiles were estimated and compared with experimental measurements for a 6 MV photon beam of a Varian Clinac 2100 for the cases of C1 and C2 both set to 0.1 or 0.001 in the target. Results: On the central axis, the dose obtained for the case C1 = C2 = 0.1 shows a deviation of (17.2% ± 1.2%) with respect to the detailed simulation. This difference decreases to (3.7% ± 1.2%) for the case C1 = C2 = 0.01. The case C1 = C2 = 0.001 produces a radial dose profile that is equivalent to that of the detailed simulation within the reached statistical uncertainty of 1%. The effect is also appreciable in the crossline dose profiles estimated for the realistic geometry of the Linac. In another simulation, it was shown that the error made by choosing inappropriate transport parameters can be masked by tuning the energy and focal spot size of the initial beam. Conclusions: The use of large path lengths for the condensed simulation of electrons in a Linac target with PENELOPE conducts to deviations of the dose in the patient or phantom. Based on the results obtained in this work, values of C1 and C2 larger than 0.001 should not be used in Linac targets without further investigation.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-473: Evaluation of Off-Axis And Peripheral Dose Using Different Detectors

Purpose: In radiation therapy, measurement of off-axis and peripheral dose is a tedious task. The dose distribution along the beam central axis give only part of the information required for an accurate dose description inside the patient. Dose distributions in 2-D and 3-D are determined with central axis data in conjunction with off-axis dose profiles. Combining a central axis dose distribution with off-axis data results in volume dose matrix that provides 2-D and 3-D information on dose distribution. By considering the importance of these two parameters this study investigates and compares the off axis and peripheral dose measurement using Ionization chamber, MOSFET, Radiochromic film and EDR2 film. Methods: In the measurement of off-axis and peripheral doses 0.6cc farmer type chamber, EDR-2 film, MD-55 radiochromic film and MOSFET detectors were used for both 6MV and 15MV beams. The off-axis and peripheral dose was measured at every 1 cm interval by changing the position of the couch without disturbing the other experimental setup in particular, the phantom with detector position. Results: Readings were obtained for both 6MV and 15MV photon beams at SSD technique for various field size using MOSFET, Ionization chamber and Radiochromic film. The results shows the percentage difference between various detectors for various field sizes. For Peripheral dose measurement were taken from the edge of the field size and for off axis it is measured form central axis dose. Conclusion: In conclusion, our study shows that no detector is ideal and only a comparison between different detectors highlights the weaknesses of each detector. MOSFET provides adequate dose assessment in off-axis and peripheral regions in 6MV and 15MV photon beams. Film dosimetry in general a convenient method to generate one- and two-dimensional dose distributions. The result of this indicates that MOSFET is flexible tool for relative dosimetry as films.

07 ISOTOPE AND RADIATION SOURCES↗

In-process volumetric sensing of defects in multiple parts during powder bed fusion using ultrasound

This letter reports on the integration of eight ultrasonic transducers into a build substrate for individual in-process monitoring of eight parts fabricated using powder bed fusion additive manufacturing. Ultrasound is shown to be able to sense poor fusion of parts to the substrate and also sensitivity to porosity. This technique demonstrates the utility of ultrasound as one of a few techniques able to interrogate the volume of additively manufactured parts during the process. Additionally, the ability to measure several parts during a single build can be used for efficient process parameter development studies, as the ultrasonic measurements can offer rapid information about part quality and integrity.

Kizer, Nathan J.↗

Features of Construction of the Fluorescent Microscope for the Study of Epithelial-Mesenchymal Transition of Cells in Vitro

An optical luminescent microscope has been developed to monitor the behavior of tumor cells that were modified by GFP and RFP fluorescent proteins and to monitor the formation of metastases in biochips. Images of cells in the light of GFP and RFP fluorescence proteins, as well as in the photography mode, are recorded in the microscope by an noncooled CMOS matrix at the excitation of luminescence by blue and green LEDs and illumination of cells with white LEDs, respectively. The obtained fluorescent images and photos in white light are recorded by the matrix in the same coordinate system and do not require additional processing for combination. The power of irradiation of cells with LEDs does not exceed 50 μW/mm{sup 2} at an exposure time of 1 s, which is an order of magnitude lower than the radiation power causing photodestruction and phototoxicity of cells during long-term studies. Relative parameters of the optical channel of the luminescent microscope have been introduced that allow comparing the sensitivity of the recording system and the minimum power level of the radiation that excites luminescence for optical elements with different spectral characteristics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dependence of the critical temperature of high-temperature cuprate superconductors on hoppings and spin correlations between CuO{sub 2} planes

The influence of interlayer hoppings on the superconducting transition temperature (T{sub c}) in bilayer cuprates has been studied. The parameter of hopping between layers is expressed as t{sub Up-Tack }(k) = t{sub Up-Tack }(cos(k{sub x}) - cos(k{sub y})){sup 2} and treated as a small perturbation for the states of two CuO{sub 2} planes described by the t-t Prime -t Double-Prime -J* model. In the generalized mean field approximation for d{sub x}{sup 2} - y{sup 2} symmetry of the superconducting gap, neither the interlayer hopping or exchange interaction, nor the pair hopping between CuO{sub 2} layers provides an additional mechanism of Cooper pair formation or an increase in T{sub c}. In the concentration dependence of T{sub c}, the bilayer splitting of the upper Hubbard band of quasi-holes is manifested as two peaks with temperatures slightly lower than the maximum T{sub c} for a single-layer cuprate. Interlayer antiferromagnetic spin correlations suppress bilayer splitting.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermonuclear targets for direct-drive ignition by a megajoule laser pulse

Central ignition of a thin two-layer-shell fusion target that is directly driven by a 2-MJ profiled pulse of Nd laser second-harmonic radiation has been studied. The parameters of the target were selected so as to provide effective acceleration of the shell toward the center, which was sufficient for the onset of ignition under conditions of increased hydrodynamic stability of the ablator acceleration and compression. The aspect ratio of the inner deuterium-tritium layer of the shell does not exceed 15, provided that a major part (above 75%) of the outer layer (plastic ablator) is evaporated by the instant of maximum compression. The investigation is based on two series of numerical calculations that were performed using one-dimensional (1D) hydrodynamic codes. The first 1D code was used to calculate the absorption of the profiled laser-radiation pulse (including calculation of the total absorption coefficient with allowance for the inverse bremsstrahlung and resonance mechanisms) and the spatial distribution of target heating for a real geometry of irradiation using 192 laser beams in a scheme of focusing with a cubo-octahedral symmetry. The second 1D code was used for simulating the total cycle of target evolution under the action of absorbed laser radiation and for determining the thermonuclear gain that was achieved with a given target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy dependence and systematics of level-density parameters in nuclei of mass number in the range of A = 20–60

Existing direct and indirect experimental data on level densities in excited nuclei of mass and charge number in the ranges of A = 20–60 and Z = 11–27, respectively, were compiled and analyzed. Contradictions between values extracted from the results of measurements performed by different methods were revealed. Consistent input data were selected, and a systematics of level-density parameters was created on this basis within the generalized model of superfluid nuclei. The effect of the first discrete vibrational levels on extracted parameters was studied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beam discharge excited by distributed virtual cathode

A new type of beam discharge, i.e., beam discharge with a distributed virtual cathode (VC) is proposed and considered by numerical simulation. The discharge is established during counter motion of high-current electron beams in a gas-filled equipotential cavity and is characterized by a state of hot dense electron plasma of primary electrons. The discharge temporal dynamics is studied. It is shown that the VC lifetime depends linearly from this sum in a wide range of the sum of beam currents, from the boundary current of two-beam instability to the critical current of Pierce instability. Generation of nonlinear electrostatic structures shaped as phase bubbles in the discharge is detected, and their dynamics is studied. The parameters are determined, at which the multiple coexistence of phase bubbles and their coalescence during collisions is observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diode lasers emitting at 1220 nm with a highly strained GaInAs quantum well and GaAsP compensating layers MOCVD-grown on a GaAs substrate

Heterostructures with an active region containing a Ga{sub 0.59}In{sub 0.41}As quantum well located between GaAs{sub 1-y}P{sub y} compensating layers were studied using photoluminescence spectroscopy. It was shown that an increase in the phosphorus content in compensating layers makes it possible to obtain unrelaxed heterostructures with wider Ga{sub 0.59}In{sub 0.41}As quantum wells. On the basis of photoluminescence studies, the parameters of such a composite active region were chosen with a view to attaining the longest lasing wavelength possible. Laser heterostructures with a composite active region consisting of a highly strained Ga{sub 0.59}In{sub 0.41}As quantum well located between GaAs{sub 0.85}P{sub 0.15} compensating layers were grown on GaAs substrates by metalloorganic chemical vapor deposition. Stripe mesa-structure laser diodes of 100-{mu}m aperture emitting at 1220 nm were fabricated. The highest emission power of these laser diodes in the continuous-wave regime amounted to 2 W per output mirror.

36 MATERIALS SCIENCE↗

Mobility of the Two-Dimensional Electron Gas in DA-pHEMT Heterostructures with Various δ–n-Layer Profile Widths

The effect of the silicon-atom distribution profile in donor δ-layers of AlGaAs/InGaAs/AlGaAs heterostructures with donor–acceptor doping on the mobility of the two-dimensional electron gas is studied. The parameters of the δ-layer profiles are determined using the normal approximation of the spatial distributions of silicon atoms, measured by secondary-ion mass spectroscopy. It is shown that the standard deviation σ of the δ-layer profile can be reduced from 3.4 to 2.5 nm by the proper selection of growth conditions. Measurements of the magnetic-field dependences of the Hall effect and conductivity show that such a decrease in σ allowed an increase in the mobility of the two-dimensional electron gas in heterostructures by 4000 cm{sup 2}/(V s) at 77 K and 600 cm{sup 2}/(V s) at 300 K. The mobility calculation taking into account filling of the first two size-quantization subbands shows that an increase in the mobility is well explained by a reduction in the Coulomb scattering at ionized donors due to an increase in the effective thickness of the spacer layer with decreasing σ of the δ-layer profile.

36 MATERIALS SCIENCE↗