Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “parameter sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Practical guide to understanding goodness-of-fit metrics used in chemical state modeling of x-ray photoelectron spectroscopy data by synthetic line shapes using nylon as an example

Chemical state analysis of a sample surface through fitting bell-shaped curves to x-ray photoelectron spectroscopic polymer data is reviewed using nylon to introduce and discuss aspects of data analysis. Different strategies for modeling chemistry in nylon spectra are presented and in so doing, a case is made to include in published science the design logic and implementation in terms of line shapes and optimization parameter constraints between components in a peak model. Imperfections in line shape relative to the true shape for photoemission lines, when compensated for using constraints to optimization parameters, are shown to provide chemical state information about a sample that justify, for peak models constructed with these limitations, metrics for goodness-of-fit different from those expected for pulse-counted data.

Materials Science↗

Methods for Quantitative Thermal Analysis of Lithium Solid-State and Beyond Battery Safety

The use of differential scanning calorimetry (DSC) to measure the thermal behavior of individual components and electrolyte/electrode combinations is common. However, here we focus on DSC tests on an anode, cathode, and electrolyte (ACE) component combination over a temperature range that includes many of the phase transitions and key reactions (i.e., to 500 °C) that contribute to thermal runaway. This method can help quantify the complex reaction network in a full cell, thereby informing potential safety issues. Here, we used DSC heat flow data from a solid-state Li 0.43 CoO 2 +C+PVDF | LLZO | Li metal ACE sample and its components to quantify key factors affecting results. We focused on three areas: (1) ACE sample preparation and assembly in DSC pans, (2) DSC measurement parameters, and (3) heat flow analysis. Key points include the choice of component ratios (e.g., commercially relevant N:P capacity ratio), the importance of conductive carbon and binder, type of pan used, DSC ramp rate, and integration method used when dealing with broad and overlapping exothermic peaks. This work deepens the scientific basis and best practices for obtaining heat flow data from ACE samples for early-stage evaluation of solid-state and beyond battery safety.

25 ENERGY STORAGE↗

Large Ensemble Diagnostic Evaluation of Hydrologic Parameter Uncertainty in the Community Land Model Version 5 (CLM5)

Abstract Land surface models such as the Community Land Model version 5 (CLM5) seek to enhance understanding of terrestrial hydrology and aid in the evaluation of anthropogenic and climate change impacts. However, the effects of parametric uncertainty on CLM5 hydrologic predictions across regions, timescales, and flow regimes have yet to be explored in detail. The common use of the default hydrologic model parameters in CLM5 risks generating streamflow predictions that may lead to incorrect inferences for important dynamics and/or extremes. In this study, we benchmark CLM5 streamflow predictions relative to the commonly employed default hydrologic parameters for 464 headwater basins over the conterminous United States (CONUS). We evaluate baseline CLM5 default parameter performance relative to a large (1,307) Latin Hypercube Sampling‐based diagnostic comparison of streamflow prediction skill using over 20 error measures. We provide a global sensitivity analysis that clarifies the significant spatial variations in parametric controls for CLM5 streamflow predictions across regions, temporal scales, and error metrics of interest. The baseline CLM5 shows relatively moderate to poor streamflow prediction skill in several CONUS regions, especially the arid Southwest and Central U.S. Hydrologic parameter uncertainty strongly affects CLM5 streamflow predictions, but its impacts vary in complex ways across U.S. regions, timescales, and flow regimes. Overall, CLM5's surface runoff and soil water parameters have the largest effects on simulated high flows, while canopy water and evaporation parameters have the most significant effects on the water balance.

54 ENVIRONMENTAL SCIENCES↗

Proportionality between Doppler noise and integrated signal path electron density validated by differenced S-X range

Observations of Viking differenced S-band/X-band (S-X) range are shown to correlate strongly with Viking Doppler noise. A ratio of proportionality between downlink S-band plasma-induced range error and two-way Doppler noise is calculated. A new parameter (similar to the parameter epsilon which defines the ratio of local electron density fluctuations to mean electron density) is defined as a function of observed data sample interval (Tau) where the time-scale of the observations is 15 Tau. This parameter is interpreted to yield the ratio of net observed phase (or electron density) fluctuations to integrated electron density (in RMS meters/meter). Using this parameter and the thin phase-changing screen approximation, a value for the scale size L is calculated. To be consistent with Doppler noise observations, it is seen necessary for L to be proportional to closest approach distance a, and a strong function of the observed data sample interval, and hence the time-scale of the observations.

Berman, A. L.↗

Orbit/attitude estimation with LANDSAT Landmark data

The use of LANDSAT landmark data for orbit/attitude and camera bias estimation was studied. The preliminary results of these investigations are presented. The Goddard Trajectory Determination System (GTDS) error analysis capability was used to perform error analysis studies. A number of questions were addressed including parameter observability and sensitivity, effects on the solve-for parameter errors of data span, density, and distribution an a priori covariance weighting. The use of the GTDS differential correction capability with acutal landmark data was examined. The rms line and element observation residuals were studied as a function of the solve-for parameter set, a priori covariance weighting, force model, attitude model and data characteristics. Sample results are presented. Finally, verfication and preliminary system evaluation of the LANDSAT NAVPAK system for sequential (extended Kalman Filter) estimation of orbit, and camera bias parameters is given.

Hall, D. L.↗

The new standard spacecraft timecode

Time is an important parameter for space-acquired measurements, in virtue of the basing of instrument analysis on a sampled sensor time series. In addition, time provides the most efficient linkage between instrument data and externally generated ancillary parameters. Attention is presently given to the rationale and form of the standard timecode structure developed by NASA, with emphasis on the important class of binary unsegmented codes. The structure provides a mechanism for the self-documentation of timecodes, so that data users can interpret time measurement in an unambiguous manner. The binary unsegmented codes are modular and easily machine-readable; they also feature expendable resolution and ambiguity periods.

Connell, E. B.↗

Magnetochemistry of the Apollo landing sites

A coherent magnetochemical picture of lunar samples is presented which was determined from a synthesis of available magnetic-property data and corresponding chemical and petrographic data for soils and rock samples collected at the Apollo landing sites. The magnetic properties of the samples are correlated with Al/Si ratio as well as with telescope spectral reflectivity curves, and magnetochemical diagrams based on composition-sensitive magnetic parameters describing the Fe metal and Fe(2+) contents are used to classify the samples. It is shown that the relative metal-fraction size distribution and magnetic stability for different rock types and soils of varying Al/Si values are reflected in a plot of the ratio of saturation isothermal remanence to saturation magnetization vs the ratio of remanent coercive force to coercive force. It is concluded that all the Apollo landing sites have distinct telescope curves correlated with petrology, chemistry, Al/Si values, and magnetic properties. The established correlations suggest the possibility of estimating the magnetic properties of the regolith from remote-sensing observations.

Wasilewski, P. J.↗

Sample Processor for Life on Icy Worlds (SPLIce): Design and Test Results

We report the design, development, and testing of the Sample Processor for Life on Icy Worlds (SPLIce) system, a microfluidic sample processor to enable autonomous detection of signatures of life and measurements of habitability parameters in Ocean Worlds. This monolithic fluid processing-and-handling system (Figure 1; mass 0.5 kg) retrieves a 50-L-volume sample and prepares it to supply a suite of detection instruments, each with unique preparation needs. SPLIce has potential applications in orbiter missions that sample ocean plumes, such as found in Saturns icy moon Enceladus, or landed missions on the surface of icy satellites, such as Jupiters moon Europa. Answering the question Are we alone in the universe? is captivating and exceptionally challenging. Even general criteria that define life very broadly include a significant role for water [1,2]. Searches for extinct or extant life therefore prioritize locations of abundant water whether in ancient (Mars), or present (Europa and Enceladus) times. Only two previous planetary missions had onboard fluid processing: the Viking Biology Experiments [3] and Phoenixs Wet Chemistry Laboratory (WCL) [4]. SPLIce differs crucially from those systems, including its capability to process and distribute L-volume samples and the integration autonomous control of a wide range of fluidic functions, including: 1) retrieval of fluid samples from an evacuated sample chamber; 2) onboard multi-year storage of dehydrated reagents; 3) integrated pressure, pH, and conductivity measurement; 4) filtration and retention of insoluble particles for microscopy; 5) dilution or vacuum-driven concentration of samples to accommodate instrument working ranges; 6) removal of gas bubbles from sample aliquots; 7) unidirectional flow (check valves); 8) active flow-path selection (solenoid-actuated valves); 9) metered pumping in 100 nL volume increments. The SPLIce manifold, made of three thermally fused layers of precision-machined cyclo-olefin polymer, supports all fluidic components (Figure 1) and integrated microchannels (125 x 250 m). Fluid is pumped by a stepper-motor-driven pump (Lee Co.). The functionality of the integrated MEMS pressure sensor (Honeywell) and passive check valves (Figure 2) were tested in conjunction with our newly designed integral bubble traps (Figure 3) and hydrophobic membrane-based concentrator (Figure 4). The concentrator (initially tested as a standalone component) demonstrated 5-fold vacuum-evaporative concentration. Polyethylene fused bead beds (PEFBBs; 50 porosity) store drylyophilized buffers, calibrants, and fluorescent dyes, and also promote mixing of sample with calibrant, dye, or H2O. Software-controlled automated tests demonstrated successful 1) fluid delivery to each component 2) valve and pump synchronization 3) sample aliquot delivery to instrument interface ports, and 4) rehydration of vacuum-dried fluorescent dye. In Figure 5, fluorescein on PEFBBs was rehydrated for 15 min using a pump-delivered water aliquot; it is displaced as H2O enters the bottom of the channel and pushes the dye into a check valve. Ultimately, SPLIce will fluorescently label amino acids in the sample for microchip-based electrophoretic (MCE) chiral separation and detection to seek and quantify key organic bio-signatures [5]; it will also deliver sample to a microfluidic version of WCL (mWCL) to measure soluble ions and redox-active species.

Life detection↗

Ferroic phase transitions and magnetoelectric coupling in cobalt doped BaTiO 3

Magnetoelectric (ME) materials exhibit interesting physics with cross coupling between ferroelectric and magnetic order parameters and thus strong potential to be utilized in memory, spintronics and other multifunctional electronic/magnetic devices. Doping of suitable transition metals in ferroelectrics can induce magnetism and ME coupling and modify the physical properties. Here, we report the structural, electronic, magnetic and ME coupling of 3.5, 5 and 7.5 mol% cobalt doped BaTiO 3 (BTO) ceramics. X-ray diffraction and Raman spectroscopy indicate that the samples are single phase having a tetragonal crystal structure with P4mm symmetry. The tetragonality ratio is found to decrease with increasing cobalt content. We observed a Fano-like asymmetric peak in the [A 1 (LO 1 )] Raman mode at ~173 cm -1 in all the cobalt doped BTO samples. The cobalt dopants are shown to be uniformly distributed throughout the surface of the samples. We observed a lowering of the ferroelectric transition temperature and increasing diffusivity parameter with increasing cobalt concentration. The electrical properties of all the samples have been investigated in detail by impedance spectroscopy and ac conductivity studies before and after the ferroelectric phase transitions. All the samples show hysteretic ferroelectric behavior with a clear saturation state that decreases with increasing cobalt content. The observed ferroelectricity in these samples is intrinsic in nature. The 3.5% cobalt doped BTO sample exhibits paramagnetic behavior whereas the 5 and 7.5% cobalt doped BTO samples show ferromagnetic ordering below 43 K. The 7.5% cobalt doped BTO samples show significant ME coupling.

36 MATERIALS SCIENCE↗

A combined experimental and crystal plasticity study of grain size effects in magnesium alloys

This work presents a method to incorporate the micro Hall-Petch equation into the crystal plasticity finite element (CPFE) framework accounting for the microstructural features to understand the coupling between grain size, texture, and loading direction in magnesium alloys. The effect of grain size and texture is accounted for by modifying the slip resistances of individual basal and prismatic systems based on the micro Hall-Petch equation. The modification based on the micro Hall-Petch equation endows every slip system at each microstructural point with a slip system-level grain size and maximum compatibility factor, which are in turn used to modify the slip resistance. While the slip-system level grain size is a measure of the grain size, the maximum compatibility factor encodes the effect of the grain boundary on the slip system resistance modification and is computed based on the Luster-Morris factor. The model is calibrated using experimental stress-strain curves of Mg-4Al samples with three different grain sizes from which the Hall-Petch coefficients are extracted and compared with Hall-Petch coefficients predicted using original parameters from previous work. The predictability of the model is then evaluated for a Mg-4Al sample with different texture and three grain sizes subjected to loading in different directions. The calibrated parameters are then used for some parametric studies to investigate the variation of Hall-Petch slope for different degrees of simulated spread in basal texture, variation of Hall-Petch slope with loading direction relative to basal poles for a microstructure with strong basal texture, and variation of yield strength with change in grain morphology. The proposed approach to incorporate the micro Hall-Petch equation into the CPFE framework provides a foundation to quantitatively model more complicated scenarios of coupling between grain size, texture and loading direction in the plasticity of Mg alloys.

Crystal plasticity↗

A Trade Study and Metric for Penetration and Sampling Devices for Possible Use on the NASA 2003 and 2005 Mars Sample Return Missions

The scientific exploration of Mars will require the collection and return of subterranean samples to Earth for examination. This necessitates the use of some type of device or devices that possesses the ability to effectively penetrate the Martian surface, collect suitable samples and return them to the surface in a manner consistent with imposed scientific constraints. The first opportunity for such a device will occur on the 2003 and 2005 Mars Sample Return missions, being performed by NASA. This paper reviews the work completed on the compilation of a database containing viable penetrating and sampling devices, the performance of a system level trade study comparing selected devices to a set of prescribed parameters and the employment of a metric for the evaluation and ranking of the traded penetration and sampling devices, with respect to possible usage on the 03 and 05 sample return missions. The trade study performed is based on a select set of scientific, engineering, programmatic and socio-political criterion. The use of a metric for the various penetration and sampling devices will act to expedite current and future device selection.

McConnell, Joshua B.↗

A Uniform Search for Nearby Planetary Companions to Hot Jupiters in TESS Data Reveals Hot Jupiters Are Still Lonely

We present the results of a uniform search for additional planets around all stars with confirmed hot Jupiters observed by the Transiting Exoplanet Survey Satellite (TESS) in its Cycle 1 survey of the southern ecliptic hemisphere. Our search comprises 184 total planetary systems with confirmed hot Jupiters with Rp > 8 R⊕ and orbital period <10 days. The Transit Least Squares algorithm was utilized to search for periodic signals that may have been missed by other planet search pipelines. While we recovered 169 of these confirmed hot Jupiters, our search yielded no new statistically validated planetary candidates in the parameter space searched (P < 14 days). A lack of planet candidates nearby hot Jupiters in the TESS data supports results from previous transit searches of each individual system, now down to the photometric precision of TESS. This is consistent with expectations from a high-eccentricity migration formation scenario, but additional formation indicators are needed for definitive confirmation. We injected transit signals into the light curves of the hot Jupiter sample to probe the pipeline's sensitivity to the target parameter space, finding a dependence proportional to ${R}_{p}^{2.32}{P}^{-0.88}$ for planets within 0.3 ≤ Rp ≤ 4 R⊕ and 1 ≤ P ≤ 14 days. A statistical analysis accounting for this sensitivity provides a median and 90% confidence interval of ${7.3}_{-7.3}^{+15.2} \% $ for the rate of hot Jupiters with nearby companions in this target parameter space. This study demonstrates how TESS uniquely enables comprehensive searches for nearby planetary companions to nearly all the known hot Jupiters.

Benjamin J Hord↗

Application of remote sensing in the determination of water quality in Nebraska reservoirs

In June, July, and August, 1975, ground truth was collected from Lake McConaughy, a 35,000 acre reservoir in western Nebraska, coincident with the overflights of LANDSAT. Water samples were collected on six different dates and analyzed for turbidity, suspended solids, and chlorophyll, parameters which had correlated well with CCT reflectances. The correlations and regressions reported were derived from data obtained on only three of the six sampling dates. The radiance values from each of the four spectral bands were printed out in the form of a map of Lake McConaughy. Reflectances in the various bands were then obtained from the map at the appropriate sampling sites. The dependent variables chlorophyll, suspended solids, and turbidity were compared to the independent variables - reflectances in the four bands - by regression analysis. Both multiple and univariate regressions were examined. It is concluded that CCT's from LANDSAT can be used to detect and quantify the water quality parameters suspended solids, turbidity, and chlorophyll.

Hergenrader, G. L.↗

Resonant Acoustic Determination of Complex Elastic Moduli

A simple, inexpensive, yet accurate method for measuring the dynamic complex modulus of elasticity is described. Using a 'free-free' bar selectively excited in three independent vibrational modes, the shear modulus is obtained by measuring the frequency of the torsional resonant mode and the Young's modulus is determined from measurement of either the longitudinal or flexural mode. The damping properties are obtained by measuring the quality factor (Q) for each mode. The Q is inversely proportional to the loss tangent. The viscoelastic behavior of the sample can be obtained by tracking a particular resonant mode (and thus a particular modulus) using a phase locked loop (PLL) and by changing the temperature of the sample. The change in the damping properties is obtained by measuring the in-phase amplitude of the PLL which is proportional to the Q of the material. The real and imaginary parts or the complex modulus can be obtained continuously as a function of parameters such as temperature, pressure, or humidity. For homogeneous and isotropic samples only two independent moduli are needed in order to characterize the complete set of elastic constants, thus, values can be obtained for the dynamic Poisson's ratio, bulk modulus, Lame constants, etc.

Brown, David A.↗

Molecular configuration and pyrolysis reactions of phenolic-novolaks.

Description of a statistical method for characterizing the structure of an average phenolic-novolak prepolymer molecule in terms of the total number of phenolic nuclei that compose the molecule and the number of these nuclei that are pendent. It is only necessary to resort to experimental pyrolysis to evaluate the thermokinetic parameters for pyrolysis for the ablator. In addition, the fraction of phenolic involved in the major pyrolysis reactions can be estimated in terms of the parameters previously evaluated. It is shown that the overlapping reactions which occur during pyrolysis of a phenolic-novolak can be resolved by pyrolyzing samples with different extents of cure. It is then possible to determine the kinetic parameters for pyrolysis for the major reactions by well-known methods which often fail when reactions are not well resolved.

Winkler, E. L.↗

Calibration and Uncertainty Estimation Using the Ensemble Kalman Filter with a Large Subsurface Flow and Transport Model - 20321

At routinely monitored groundwater contamination sites, periodically measured environmental conditions such as groundwater levels and contaminant concentrations are used to inform and confirm a conceptual site model (CSM) and guide the development and calibration of a numerical groundwater flow and transport model. The calibration of groundwater flow and transport models after each measurement (sampling) event can illuminate deficiencies in a CSM, identify areas where additional monitoring is warranted, and predict the behavior of the system to guide decision making. However, manual and automated (e.g. PEST) model calibration tools can be time-consuming and computationally expensive to implement after each sampling event. Perhaps as a result, such calibration tools generally utilize all available monitoring data simultaneously rather than sequentially assimilating monitoring data one sampling event at a time as the results from sampling become available. A more real-time data assimilation approach may reduce parameter uncertainty, quantify the value of additional monitoring data, and produce a usable model more quickly and with less effort. To mitigate the potential time-consuming aspects of manual and widely applied automated calibration techniques, a data assimilation algorithm called the ensemble Kalman filter (EnKF) was evaluated as a relatively efficient method of model calibration and uncertainty assessment via the sequential integration of monitoring data into a model. The EnKF was able to successfully and efficiently assimilate monitoring and modeling data to calibrate a complex flow and transport model at a real-world site with significant subsurface heterogeneity, uncertainty, and 12 years of monitoring data (over 4,000 individual measurements of groundwater levels and over 2,500 measurements of contaminant concentrations). Starting with an uncalibrated model data from annual sampling events were sequentially assimilated, and the resultant predication errors and estimated parameter uncertainties were tracked. After all monitoring data were assimilated, both flow and transport residuals at the end of the EnKF process were comparable to those produced via a concurrent PEST calibration effort but required fewer model simulations. Both uncertainty and prediction errors decreased over time. In a real-time application, the adequacy of the model could be assessed after each sampling event. The benefits of such a real-time approach to utilizing monitoring data include reduced costs (in the form of model updates or site characterization efforts), early flagging of possible errors in the CSM, and a reduced risk of overfitting and corresponding increased confidence in model predictions. This tool may be particularly useful compared to other calibration techniques (e.g. manual, PEST) when model runtimes are long, calibration parameters are many, or parameter uncertainty is large. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EXCHANGE Campaign 1: A Community-Driven Baseline Characterization of Soils, Sediments, and Water Across Coastal Gradients

The EXploration of Coastal Hydrobiogeochemistry Across a Network of Gradients and Experiments (EXCHANGE) program is a consortium of scientists working together to improve our understanding of how the two-way exchange of water between estuaries or large lake lacustuaries and the terrestrial landscape influence the state and function of ecosystems across the coastal interface. EXCHANGE Campaign 1 (EC1) focuses on the spatial variation in biogeochemical structure and function at the coastal terrestrial-aquatic interface (TAI). In the Fall of 2021, the EXCHANGE Consortium gathered samples from 52 TAIs. Samples collected from EC1 were analyzed for bulk geochemical parameters, bulk physicochemical parameters, organic matter characteristics, and redox-sensitive elements.Please download ec1_README.pdf for a complete list of available data in each .zip folder, package version history, and detailed information about the project. This README will serve as the central place for EC1 Data Package updates. Experimental setup and v1 methods are documented in Myers-Pigg and Pennington et al., 2023 (https://doi.org/10.1038/s41597-023-02548-7).EC1 Data Package Structure:ec1_README.pdfec1_methods.pdfec1_metadata_v3.zip...ec1_dd.csv...ec1_flmd.csv...ec1_sample_catalog.csv...ec1_metadata_kitlevel.csv...ec1_metadata_collectionlevel.csv...ec1_data_collectionlevel.csv...ec1_igsn_metadata.csvec1_soil_v3.zipec1_sediment_v3.zipec1_water_v3.zipec1_processingscripts_v3.zipThis data package is on v3 and was originally published May 2023 (v1). Subsequent updates will be published here with new version numbers. Please see the Change History section in ec1_README.pdf for detailed changes.---Acknowledging EXCHANGE: General Support and Data Product UseWe ask that users of EXCHANGE data add the following acknowledgement when publishing data in scholarly articles and data repositories:"This research is based on work supported by COMPASS-FME, a multi-institutional project supported by the U.S. Department of Energy, Office of Science, Biological and Environmental Research as part of the Environmental System Science Program."

54 ENVIRONMENTAL SCIENCES↗

Estimation of Bare Surface Soil Moisture and Surface Roughness Parameter Using L-Band SAR Image Data

An algorithm based on a fit of the single-scattering Integral Equation Method (IEM) was developed to provide estimation of soil moisture and surface roughness parameter (a combination of rms roughness height and surface power spectrum) from quasi-polarized synthetic aperture radar (SAR) measurements. This algorithm was applied to a series of measurements acquired at L-band (1.25 GHz) from both AIRSAR (Airborne Synthetic Aperture Radar operated by Jet Propulsion Laboratory) and SIR-C (Spaceborne Imaging Radar-C) over a well-managed watershed in southwest Oklahoma. It was found that the two co-polarized backscattering coefficients and their combinations would provide the best input to the algorithm for estimation of soil moisture and roughness parameter. Application of the inversion algorithm to the co-polarized measurements of both AIRSAR and SIR-C resulted in estimated values of soil moisture and roughness parameter for bare and short-vegetated fields that compared favorably with those sampled on the ground. The root-mean-square (rms) errors of the comparison were found to be 3.4% and 1.9 dB for soil moisture and surface roughness parameter, respectively.

Shi, Jian-Cheng↗