Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

The NASA-UC-UH Eta-Earth program. IV. A low-mass planet orbiting an M dwarf 3.6 PC from Earth

We report the discovery of a low-mass planet orbiting Gl 15 A based on radial velocities from the Eta-Earth Survey using HIRES at Keck Observatory. Gl 15 Ab is a planet with minimum mass Msin i = 5.35 ± 0.75 M {sub ⊕}, orbital period P = 11.4433 ± 0.0016 days, and an orbit that is consistent with circular. We characterize the host star using a variety of techniques. Photometric observations at Fairborn Observatory show no evidence for rotational modulation of spots at the orbital period to a limit of ∼0.1 mmag, thus supporting the existence of the planet. We detect a second RV signal with a period of 44 days that we attribute to rotational modulation of stellar surface features, as confirmed by optical photometry and the Ca II H and K activity indicator. Using infrared spectroscopy from Palomar-TripleSpec, we measure an M2 V spectral type and a sub-solar metallicity ([M/H] = –0.22, [Fe/H] = –0.32). We measure a stellar radius of 0.3863 ± 0.0021 R {sub ☉} based on interferometry from CHARA.

79 ASTRONOMY AND ASTROPHYSICS↗

DOE SCGSR Final Report - Project Accomplishments and Additional Materials

The major accomplishments of my project were successfully developing and testing the laser interferometry diagnostic on the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). This diagnostic helped advance my research by providing a simpler way to obtain electron density measurements of magnetized plasmas compared to other electron density diagnostics such as triple Langmuir probes. The laser used was a 561 nm continuous wave (CW) diode-pumped solid state (DPSS) laser. The PLX laser interferometry diagnostic consists of two parts. These include the launching and receiving sides of the laser diagnostic. The launching side consists of the main laser beam from the DPSS laser being split into five chords(probe beams) and a reference beam which are then directed with fiber optic couplers into fiber optic cables which transmit the probe beamsto the PLX vacuum chamber. The probe beams then pass through the plasma in the chamber and into the receiving side optics where they are again directed through fiber optic cables to be combined with the reference beam. The combined beams are transmitted via multi-mode fiber optic cables to photodiodes to convert the light signals into electrical signals. Before the electrical signals get digitized, they pass through bandpass and low pass filters to eliminate electromagnetic noise and unwanted frequencies. The electrical signals are then processed by IQ demodulators to determine phase angle difference between the probe and reference beams for each chord in order to calculate line-integrated electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Resolution X-ray Imaging

Improved image quality is of central importance to the future of X ray astronomy. We show that the optical tolerances necessary to push the quality of grazing incidence telescopes well beyond their current one arcsecond limit, are achievable. We also discuss a new approach to X ray optics that has been under development and is already showing resolution as high a 0.1 arcseconds. We argue that diffraction limited resolution should be considered as a viable goal for a new start among the next generation observatories, and follow the line of reasoning into X ray interferometry as a long term goal.

Cash, Webster↗

SIM Narrow and wide angle astrometric demonstration on the MAM testbed.

The Space Interferometry Mission (SIM) requires fringe measurements to the level of picometers in order to produce astrometric data at the micro-arc-second level. To be more specific, it is necessary to measure both the position of the starlight central fringe and the change in the internal optical path of the interferometer to tens of picometers. The internal path is measured with a small heterodyne metrology beam, whereas the starlight fringe position is estimated with a CCD sampling a large concentric annular beam. One major challenge for SIM is to align the metrology beam with the starlight beam to keep the consistency between these two sensors at the system level while articulating the instrument optics over the field of regard. The Micro-Arcsecond Metrology testbed (MAM), developed at the Jet Propulsion Laboratory, features an optical interferometer with a white light source, all major optical components of a stellar interferometer and heterodyne metrology sensors. The setup is installed inside a large vacuum chamber in order to mitigate the atmospheric and thermal disturbances. Astrometric observations are simulated by articulating the optics over the 15 degrees field of regard to generate multiple artificial stars. Recent data show agreement between the metrology and starlight paths to 20pm in the narrow angle field and to 350pm in the full wide angle field of regard of SIM. This paper describes the MAM optical setup, the observation process, the current data and how the performance relates to SIM.

Catanzarite, Joseph H.↗

Microgravity research applications of interferometry to heat and mass transfer

Major space flight experiments which have used interferometric measurement as a major support system are described together with similar ground-based research. Space experiments include those flown on Spacelab 3 ad on the D-1 mission. Included in the ground-based experiments are aircraft studies, Spacelab 3 data reduction and evaluation, and supportive laboratory hardware development. It is shown that optical measurement techniques are crucial to microgravity research.

Owen, Robert B.↗

Kite: Status of the External Metrology Testbed for SIM

Kite is a system level testbed for the External Metrology system of the Space Interferometry Mission (SIM). The External Metrology System is used to track the fiducial that are located at the centers of the interferometer's siderostats. The relative changes in their positions needs to be tracked to tens of picometers in order to correct for thermal measurements, the Kite testbed was build to test both the metrology gauges and out ability to optically model the system at these levels. The Kite testbed is an over-constraint system where 6 lengths are measured, but only 5 are needed to determine the system. The agreement in the over-constrained length needs to be on the order of 140 pm for the SIM Wide-Angle observing scenario and 8 pm for the Narrow-Angle observing scenario. We demonstrate that we have met the Wide-Angle goal with our current setup. For the Narrow-Angle case, we have only reached the goal for on-axis observations. We describe the testbed improvements that have been made since our initial results, and outline the future Kite changes that will add further effects that SIM faces in order to make the testbed more SIM like.

metrology↗

Measurement of the configuration of a concave surface by the interference of reflected light

A method whereby a concave surface is irradiated with coherent light and the resulting interference fringes yield information on the concave surface is described. This method can be applied to a surface which satisfies the following conditions: (1) the concave face has a mirror surface; (2) the profile of the face is expressed by a mathematical function with a point of inflection. In this interferometry, multilight waves reflected from the concave surface interfere and make fringes wherever the reflected light propagates. Interference fringe orders. Photographs of the fringe patterns for a uniformly loaded thin silicon plate clamped at the edge are shown experimentally. The experimental and the theoretical values of the maximum optical path difference show good agreement. This simple method can be applied to obtain accurate information on concave surfaces.

Kumazawa, T.↗

Improved Skin Friction Interferometer

An improved system for measuring aerodynamic skin friction which uses a dual-laser-beam oil-film interferometer was developed. Improvements in the optical hardware provided equal signal characteristics for each beam and reduced the cost and complexity of the system by replacing polarization rotation by a mirrored prism for separation of the two signals. An automated, objective, data-reduction procedure was implemented to eliminate tedious manual manipulation of the interferometry data records. The present system was intended for use in two-dimensional, incompressible flows over a smooth, level surface without pressure gradient, but the improvements discussed are not limited to this application.

Westphal, R. V.↗

A Comparison of Three Methods for Measuring Distortion in Optical Windows

It's important that imagery seen through large-area windows, such as those used on space vehicles, not be substantially distorted. Many approaches are described in the literature for measuring the distortion of an optical window, but most suffer from either poor resolution or processing difficulties. In this paper a new definition of distortion is presented, allowing accurate measurement using an optical interferometer. This new definition is shown to be equivalent to the definitions provided by the military and the standards organizations. In order to determine the advantages and disadvantages of this new approach, the distortion of an acrylic window is measured using three different methods: image comparison, moiré interferometry, and phase-shifting interferometry.

Interferometry↗

Segmented mirror coarse phasing with white light interferometry: modeling and experiment on NGST's wavefront control testbed

A method of coarse phasing segmented mirrors using white light interferometry (WLI) has been developed for Next Generation Space Telescope (NGST) wavefront sensing and control. Using the broadband point spread function (PSF) of the segmented mirrors taken during a segment piston scan, the WLI can accurately detect small residual piston errors. WLI does not rely on any extra optics and uses only the final imaging camera. With its high sensitivity to small segment piston error WLI can be used as a complementary phasing algorithm to the dispersed fringe sensor (DFS) for NGST. The paper will present the results from modeling and experiment on the NGST's Wavefront Control Testbed (WCT).

Space↗

The epsilon Eridani system resolved by millimeter interferometry

We present observations of ϵ Eridani from the Submillimeter Array (SMA) at 1.3 mm and from the Australia Telescope Compact Array at 7 mm that reach an angular resolution of ∼4″ (13 AU). These first millimeter interferometer observations of ϵ Eridani, which hosts the closest debris disk to the Sun, reveal two distinct emission components: (1) the well-known outer dust belt, which, although patchy, is clearly resolved in the radial direction, and (2) an unresolved source coincident with the position of the star. We use direct model-fitting of the millimeter visibilities to constrain the basic properties of these two components. A simple Gaussian shape for the outer belt fit to the SMA data results in a radial location of 64.4{sub −3.0}{sup +2.4} AU and FWHM of 20.2{sub −8.2}{sup +6.0} AU (fractional width ΔR/R = 0.3). Similar results are obtained taking a power law radial emission profile for the belt, though the power law index cannot be usefully constrained. Within the noise obtained (0.2 mJy beam{sup −1}), these data are consistent with an axisymmetric belt model and show no significant azimuthal structure that might be introduced by unseen planets in the system. These data also limit any stellocentric offset of the belt to <9 AU, which disfavors the presence of giant planets on highly eccentric (>0.1) and wide (10's of AU) orbits. The flux density of the unresolved central component exceeds predictions for the stellar photosphere at these long wavelengths, by a marginally significant amount at 1.3 mm but by a factor of a few at 7 mm (with brightness temperature 13000 ± 1600 K for a source size of the optical stellar radius). We attribute this excess emission to ionized plasma from a stellar corona or chromosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical instrumentation engineering in science, technology and society; Proceedings of the Sixteenth Annual Technical Meeting, San Mateo, Calif., October 16-18, 1972

Visual tracking performance in instrumentation is discussed together with photographic pyrometry in an aeroballistic range, optical characteristics of spherical vapor bubbles in liquids, and the automatic detection and control of surface roughness by coherent diffraction patterns. Other subjects explored are related to instruments, sensors, systems, holography, and pattern recognition. Questions of data handling are also investigated, taking into account minicomputer image storage for holographic interferometry analysis, the design of a video amplifier for a 90 MHz bandwidth, and autostereoscopic screens. Individual items are announced in this issue.

Katz, Y. H.↗

Step Bunch Evolution on Vicinal Faces of KDP

For in-situ studies of the formation and evolution of step patterns in solution growth, we have assembled an experimental setup based on Michelson interferometry with the growing crystal surface as one of the reflective surfaces. The device allows data collection over a relatively large area (approximately 4 sq. mm) in situ and in real time during growth. The depth resolution is improved over traditional interferometry using phase-shifted images combining by a suitable algorithm. We achieve a depth resolution of approximately 50 Angstroms. Lateral resolution, dependent on the degree of magnification, is around 0.3 to 5 microns. The crystal chosen as a model in this work is potassium dihydrogen phosphate (KDP), the optically non-linear material widely used in frequency doubling applications. Kinetics of KDP crystallization is well studied so that KDP can serve as a benchmark for our investigations. We present quantitative results on the onset, initial stages and development of instabilities in moving step trains on vicinal crystal surfaces at varying supersaturation, flow rate, and flow direction. The kinetics data suggest that at low supersaturations, step bunching is caused by impurity retardation of the steps, while at higher supersaturations, we link the non-linearity during growth to interdependence of the velocity and density of the steps evidenced in independent experiments. The behavior on the surface is very dynamic, small bunches both merge and split from larger bunches as they travel across the facet. We present evidence that despite these dynamics, under steady conditions there exists a limiting value to step bunch height. This height is reached at distances between 600 and 1000 microns from the step source. In our experiments, we observed the retention of this step bunch height limit up to the path of 1500 microns.

Booth, N. A.↗

Optical metrology for testing an all-composite 2-meter diameter mirror

The Herschel Space Observatory (formerly known as FIRST) consists of a 3.5 m space telescope designed for use in the long IR and sub-milimeter wavebands. To demonstrate the viability of a carbon fiber composite telescope for this application, Composite Optics Incorporated (COI) manufactured a fast (f/1), large (2 m), lightweight (10.1 kg/m squared) demonstration mirror. A key challenge in demonstrating the performance of this novel mirror was to characterize the surface accuracy at cryogenic (70 K) temperatures. A wide variety of optical metrology techniques were investigated and a brief survey of empirical test results and limitations of the various techniques will be presented in this paper. Two complementary infrared (IR)techniques operating at a wavelength of 10.6 microns were chosen for further development: (1) IR Twyman-Green Phase Shifting Interferometry (IR PSI) and (2) IR Shack-Hartmann (IR SH) Wavefront Sensing. Innovative design modifications made to an existing IR PSI to achieve high-resolution, scannable, infrared measurements of the composite mirror are described. The modified interferometer was capable of measuring surface gradients larger than 350 microradians. The design and results of measurements made with a custom-built IR SH Wavefrong Sensor operating at 10.6 microns are also presented. A compact experimental setup permitting simultaneous operation of both the IR PSI and IR SH tools is shown. The advantages and the limitations of the two key IR metrology tools are discussed.

IR metrology phase shifting interferometry Shack-H↗

SIM spectral characteristics and accuracy analysis

The Space Interferometry Mission (SIM) will perform global astrometry (full sky), local wide-angle (15 degree) and narrow-angle (1 degree) observations to search extra-solar planets, and can calibrate stellar and galactic evolution theories. The astrometric accuracy of the SIM mission depends on spectral characteristics of the optics, detectors and targets. This paper will discuss the photometric throughput of the SIM instrument, and analyze effects of wavefront errors, optical mismatches and control biases as a function of wavelength. The color dependence models of the instrument optics including mirrors, lenses, field-stop and beam-splitter are presented. The performances of different detectors with a variety of coatings are compared. A model of the SIM fringe spectrometer is created. For early and late types of stars, brightness dependency errors are analyzed for different combinations of optics and detectors. Visibility loss due to imperfect optics is investigated in detail. Based on the models of instrument and estimated visibilities, the astrometric accuracies for various kinds of stars are evaluated. It is important to emphasize that not only light sources, mirrors, lenses, field stop and detectors are all wavelength dependent, but also fringe visibility loss, wavefront error, optics control error, etc. are all a function of wavelengths. For the first time the estimate of SIM performance is based on spectral analysis of all factors above, rather than monochromatic approximations of detected fringes, or simply adopted constants. This paper summarizes the astrometric accuracies for a wide range of stars and various combinations of optical design and detector configurations. It has been verified that SIM has astrometric accuracy of about 4 μas for targets with different spectra.

Shao, Michael↗

Combinations of Earth Orientation Measurements: SPACE2005, COMB2005, and POLE2005

Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, by very long baseline interferometry, and by the Global Positioning System have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2005, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28, 1976, to January 7, 2006, at daily intervals and is available in versions whose epochs are given at either midnight or noon. The space-geodetic measurements used to generate SPACE2005 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2005, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20, 1962, to January 7, 2006, at daily intervals and which is also available in versions whose epochs are given at either midnight or noon; and (2) POLE2005, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900, to December 21, 2005, at 30.4375-day intervals.

laser ranging↗

Diffusivity Measured as a Function of Concentration

Optical diagnostic techniques have become an integral part of many measurements in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used to measure optical wave fronts for lens testing and combustion and fluid flow diagnostics. One such instrument is the point diffraction interferometer (PDI), which is considered to be robust because it has a common-path design. However, the PDI is difficult to align and has limited measurement range for liquid phase applications. Interferometry and schlieren techniques have been widely used for many years for gas flow visualization.

Rashidnia, Nasser↗