Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

A Short-Range Distance Sensor with Exceptional Linearity

A sensor has been demonstrated that can measure distance over a total range of about 300 microns to an accuracy of about 0.1 nm (resolution of about 0.01 nm). This represents an exceptionally large dynamic range of operation - over 1,000,000. The sensor is optical in nature, and requires the attachment of a mirror to the object whose distance is being measured. This work resulted from actively developing a white light interferometric system to be used to measure the depths of defects in the Space Shuttle Orbiter windows. The concept was then applied to measuring distance. The concept later expanded to include spectrometer calibration. In summary, broadband (i.e., white) light is launched into a Michelson interferometer, one mirror of which is fixed and one of which is attached to the object whose distance is to be measured. The light emerging from the interferometer has traveled one of two distances: either the distance to the fixed mirror and back, or the distance to the moving mirror and back. These two light beams mix and produce an interference pattern where some wavelengths interfere constructively and some destructively. Sending this light into a spectrometer allows this interference pattern to be analyzed, yielding the net distance difference between the two paths. The unique feature of this distance sensor is its ability to measure accurately distance over a dynamic range of more than one million, the ratio of its range (about 300 microns) to its accuracy (about 0.1 nanometer). Such a large linear operating range is rare and arises here because both amplitude and phase-matching algorithms contribute to the performance. The sensor is limited by the need to attach a mirror of some kind to the object being tracked, and by the fairly small total range, but the exceptional dynamic range should make it of interest.

Simmons, Steven↗

Throughput of the Composite Infrared Spectrometer (CIRS) Mid Infrared (MIR) Channel for the Cassini Mission to Saturn

The Composite Infrared Spectrometer (CIRS) of the Cassini mission to Saturn has two interferometers covering the far infrared and mid infrared wavelength region. The instrument was aligned at ambient temperature, but operates at 170 Kelvin and has challenging interferometric alignment tolerances. Cryogenic alignment tests of the instrument indicate that it should suffer minimal degradation due to the cooldown from ambient to operational temperature. System level tests performed by the calibration team indicated a lower than expected signal level on the MIR channel, while providing ambiguous optical throughput data. Therefore it became imperative to develop a metric that could be used to determine the instrument performance at both the instrument and system levels, at ambient and cryogenic temperature. Modulation efficiency and throughput measurements were performed and new analytical models developed to evaluate the status of the instrument. Empirical and analytical data were eventually reconciled and deviations from the design values explained.

Hagopian, John G.↗

Khayyam; Progress and Prospects of Coupling a Spatial Heterodyne Spectrometer (SHS) to a Cassegrain Telescope for Optical Interferometry

In the temporal study of faint, extended sources at high resolving power, Spatial Heterodyne Spectrometer (SHS) can offer significant advantages about conventional dispersive grating spectrometers. We describe here a four-year continuous progress in Mt. Hamilton, Lick Observatory, toward development of a prototype reflective Spacial Heterodyne Spectrometer, Khayyam, instrument-telescope configuration to combine all of the capabilities necessary to obtain high resolving power visible band spectra of diffuse targets from small aperture on-axis telescopes where significant observing time can be obtained. We will discuss the design considerations going into this new system, installation, testing of the interferometer-telescope combination, the technical challenges and procedures moving forward.

extended targets↗

Adaptive Nulling: A New Enabling Technology for Interferometric Exoplanet

Deep, stable nulling of starlight requires careful control of the amplitudes and phases of the beams that are being combined. The detection of earth-like planets using the interferometer architectures currently being considered for the Terrestrial Planet Finder mission require that the E-field amplitudes are balanced at the level of approx. 0.1%, and the phases are controlled at the level of 1 mrad (corresponding to approx.1.5 nm for a wavelength of 10 microns). These conditions must be met simultaneously at all wavelengths across the science band, and for both polarization states, imposing unrealistic tolerances on the symmetry between the optical beamtrains. We introduce the concept of a compensator that is inserted into the beamtrain, which can adaptively correct for the mismatches across the spectrum, enabling deep nulls with realistic, imperfect optics. The design presented uses a deformable mirror to adjust the amplitude and phase of each beam as an arbitrary function of wavelength and polarization. A proof-of-concept experiment will be conducted at visible/near-IR wavelengths, followed by a system operating in the Mid-IR band.

planet detection↗

Metrology of IXO Mirror Segments

For future x-ray astrophysics mission that demands optics with large throughput and excellent angular resolution, many telescope concepts build around assembling thin mirror segments in a Wolter I geometry, such as that originally proposed for the International X-ray Observatory. The arc-second resolution requirement posts unique challenges not just for fabrication, mounting but also for metrology of these mirror segments. In this paper, we shall discuss the metrology of these segments using normal incidence metrological method with interferometers and null lenses. We present results of the calibration of the metrology systems we are currently using, discuss their accuracy and address the precision in measuring near-cylindrical mirror segments and the stability of the measurements.

Chan, Kai-Wing↗

Phase-Array Approach to Optical Whispering Gallery Modulators

This technology leverages the well-defined orbital number of a whispering gallery modulator (WGM) to expand the range of applications for such resonators. This property rigidly connects the phase variation of the field in this mode with the azimuthal angle between the coupling locations. A WGM with orbital momentum L has exactly L instant nodes around the circumference of the WGM resonator supporting such a mode. Therefore, in two locations separated by the arc alpha, the phase difference of such a field will be equal to phi= alpha L. Coupling the field out of such locations, and into a balanced interferometer, once can observe a complete constructive or distractive interference (or have any situation in between) depending on the angle alpha. Similarly, a mode L + delta L will pick up the phase phi + alpha delta L. In all applications of a WGM resonator as a modulator, the orbital numbers for the carrier and sidebands are different, and their differences delta L are known (usually, but not necessarily, delta L = 1). Therefore, the choice of the angle alpha, and of the interferometer arms difference, allows one to control the relative phase between different modes and to perform the conversion, separation, and filtering tasks necessary.

Strekalov, Dmitry↗

Design and fabrication of a brassboard optical bench structure for space interferometry mission

The Space Interferometry Mission (SIM), consisting of an orbiting pair of telescopes, will be used for characterization of extrasolar planetary systems and for associated astrophysics research. To maximize the capabilities of this instrument, extensive technology development has been performed, much of it to understand and verify the performance of precision structures.

dimensional stability↗

Far-infrared spectra of W51-IRS 2 and W49 NW

Measurements of the far-infrared spectra of the powerful H II regions W51-IRS 2 and W49 NW from 65 to 345 per cm with about 9 per cm resolution were obtained by using an airborne Michelson interferometer. The most remarkable feature of the far-infrared spectra of the two regions is the smoothness of the continuum; no evidence is found in the spectra for features of H2O ice at 45 and 62 microns. The spectrum of W51 is well fitted by a 70 K blackbody with a diameter of 14 arc sec, but the spectrum of W49 NW is narrower than a blackbody. The implications of the apparently high peak optical depths of these sources are discussed.

Erickson, E. F.↗

Using scripting languages in optical interferometry

We discuss client-side CORBA scripts implemented in Tcl, Perl, and Python. These are all technologies that are either currently being used on testbeds at JPL or being evaluated for future use. Finally, a Python example demonstrating implementation of a simple CORBA server is presented.

CORBA↗

Lock-In Imaging System for Detecting Disturbances in Fluid

A lock-in imaging system is configured for detecting a disturbance in air. The system includes an airplane, an interferometer, and a telescopic imaging camera. The airplane includes a fuselage and a pair of wings. The airplane is configured for flight in air. The interferometer is operatively disposed on the airplane and configured for producing an interference pattern by splitting a beam of light into two beams along two paths and recombining the two beams at a junction point in a front flight path of the airplane during flight. The telescopic imaging camera is configured for capturing an image of the beams at the junction point. The telescopic imaging camera is configured for detecting the disturbance in air in an optical path, based on an index of refraction of the image, as detected at the junction point.

Park, Yeonjoon↗

Interferometer with Continuously Varying Path Length Measured in Wavelengths to the Reference Mirror

An interferometer in which the path length of the reference beam, measured in wavelengths, is continuously changing in sinusoidal fashion and the interference signal created by combining the measurement beam and the reference beam is processed in real time to obtain the physical distance along the measurement beam between the measured surface and a spatial reference frame such as the beam splitter. The processing involves analyzing the Fourier series of the intensity signal at one or more optical detectors in real time and using the time-domain multi-frequency harmonic signals to extract the phase information independently at each pixel position of one or more optical detectors and converting the phase information to distance information.

Ohara, Tetsuo↗

The far-infrared spectrum of the core of Sagittarius B2

A Michelson interferometer aboard NASA's Kuiper Airborne Observatory has been used to measure the spectrum of Sgr B2 from 40 to 200 kaysers with 5-kayser resolution in a 1.4-arcmin beam. The measured spectrum is smooth and featureless with a broad maximum at about 85 kaysers. The data can be fitted analytically with a model corresponding to thermal emission by a uniform sla of dust filling the beam, with an average temperature of approximately 32 K, an optical depth at 100 microns of about 1.6, and a spectral index of the dust emissivity about 1.5. The absence of features implies either that the source is optically thick or that the emission spectrum of the individual grains is smooth in the passband. The possible physical significance of this model is discussed.

Erickson, E. F.↗

Fabry-Perot Based Radiometers for Precise Measurement of Greenhouse Gases

Differential radiometers based upon the Fabry-Perot interferometer have been developed and demonstrated that exhibit very great sensitivity to changes in the atmospheric column of carbon dioxide, oxygen, and water vapor. These instruments employ a solid Fabry-Perot etalon that is tuned to the proper wavelength by changing the temperature. By choosing the thickness of the etalon its multiple pass bands can be made to align with regularly space absorption features of the molecule under investigation. Use of multiple absorption features improves the optical throughput of the instrument and improves the stability of the instrument response with respect to environmental changes. Efforts are underway at Goddard to extend this technique to the carbon 13 isotope of carbon dioxide and to methane. These instruments are intrinsically rugged and can be made rather small and inexpensively. They therefore hold promise for widespread use in ground based networks for calibration of satellite instruments such as OCO and GOSAT. Results will be presented for ground based and airborne operations for these systems. The effects of atmospheric scattering, pointing errors, pressure broadening and temperature effects will be discussed with regard to achieving precision better than .5% required for validation of carbon dioxide column measured from space. Designs permitting the extension of the technique to an even larger number of atmospheric species will be discussed along with theoretical analysis of potential system performance.

Heaps, William S.↗

A shock tube study of line broadening in a temperature range of 6100 to 8300 K

Line widths of the Ca(II) 3968 A and Na(I) 5890 A resonance lines broadened by electric microfields in a plasma were measured. A pressure-driven shock tube was used as the light source. Radiation from the equilibrium region behind the reflected shock wave was studied using a rapid scanning Fabry-Perot interferometer. Electron and argon atom densities of about 8 x 10 to the 16th and 1 x 10 to the 19th/cu cm, respectively, were achieved at the relatively low temperature of around 7500 K by vaporizing a cesium powder that had been added to the shock tube as a solid aerosol in argon gas. The measured line widths were predominantly Stark broadened by the electrons and ions in the plasma, although Doppler, van der Waals, instrument function and optical depth effects had to be taken into account.

Baur, J. F.↗

Optical design of the ATMOS Fourier transform spectrometer

The optical system design of the ATMOS Fourier transform spectrometer to be operated from Spacelab for the measurement of stratospheric trace molecules is described. The design contains features which can achieve the required fringe contrast of 80% and spectral resolution of 0.02/cm over a spectral range of 2-16 microns. In particular, the design is based on the following features which alleviate the usual requirements for alignment precision: (1) 'cat's eye' mirror configuration in the two arms of the interferometer for retroreflection stability, (2) tilt-compensated system of beamsplitter, compensator, and fold mirrors for wavefront directional stability, (3) paraboloidal 'cat's eye' primary mirror for wavefront stability against shear, (4) rotatable compensator for matching chromatic dispersion, and (5) wedged refractive components to avoid channel spectra due to the Fabry-Perot effect.

Abel, I. R.↗

Solid state laser systems for space application

Since the last report several things have happened to effect the research effort. In laser metrology, measurements using Michelson type interferometers with an FM modulated diode laser source have been performed. The discrete Fourier transform technique has been implemented. Problems associated with this technique as well as the overall FM scheme were identified. The accuracy of the technique is not at the level we would expect at this point. We are now investigating the effect of various types of noise on the accuracy as well as making changes to the system. One problem can be addressed by modifying the original optical layout. Our research effort was also expanded to include the assembly and testing of a diode pumped\Nd:YAG laser pumped\Ti sapphire laser for possible use in sounding rocket applications. At this stage, the diode pumped Nd:YAG laser has been assembled and made operational.

Kay, Richard B.↗

Dynamic interferometer alignment and its utility in UV Fourier transform spectrometer systems

Dynamic alignment has been demonstrated as a practical approach to alignment maintenance for systems in the infrared region of the spectrum. On the basis of work done by OPTRA, this technique was introduced in commercial Fourier transform spectrometer systems in 1982 and in various forms is now available from a number of manufacturers. This paper reports on work by OPTRA to extend the basic technique to systems operating in the ultraviolet. In addition, this paper reports the preliminary results of the development of an alignment system using a laser diode in place of a gas laser normally found in dynamic alignment systems. A unique optical system and spatial heterodyne technique allows for achievement of a metrology system with characteristics that fully satisfy the requirements of an ultraviolet spectrometer system.

Dorval, Rick K.↗

The Primordial Inflation Explorer (PIXIE): A Nulling Polarimeter for Cosmic Microwave Background Observations

The Primordial Inflation Explorer (PIXIE) is a concept for an Explorer-class mission to measure the gravity-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background. The instrument consists of a polarizing Michelson interferometer configured as a nulling polarimeter to measure the difference spectrum between orthogonal linear polarizations from two co-aligned beams. Either input can view the sky or a temperature-controlled absolute reference blackbody calibrator. Rhe proposed instrument can map the absolute intensity and linear polarization (Stokes I, Q, and U parameters) over the full sky in 400 spectral channels spanning 2.5 decades in frequency from 30 GHz to 6 THz (1 cm to 50 micron wavelength). Multi-moded optics provide background-limited sensitivity using only 4 detectors, while the highly symmetric design and multiple signal modulations provide robust rejection of potential systematic errors. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r < 10..3 at 5 standard deviations. The rich PIXIE data set can also constrain physical processes ranging from Big Bang cosmology to the nature of the first stars to physical conditions within the interstellar medium of the Galaxy.

Kogut, Alan J.↗