At least 1,027 records · Page 57

High efficiency conical scanner for earth resources applications

A description is given of a six-arm conical scanner which was selected to provide a continuous line-of-sight scan. Two versions of the instrument are considered. The two versions differ in their weight. The weight of the heavy version is 600 lbs. A light weight design which employs beryllium and aluminum optical components weighs only 350 lbs. A multiplexer and analog-to-digital converter are to be incorporated into the design. Questions of instrument performance are also discussed.

Bates, J. C.↗

Propeller modulation effects on a scanning-beam microwave landing system

The results of a systems study and ground test of the effects of propeller modulation on a time-multiplexed, scanning-beam microwave landing system (MLS) are presented. Propeller modulation effects are analyzed in terms of spacing between receiving antenna and propeller, propeller blade width, and propeller speed. Principal study conclusions: (1) scanning beam MLS is susceptible to errors due to synchronous propeller modulation; (2) the number of synchronous interference multiples increases as the number of propeller blades increases and as the data rate decreases; (3) the probability of synchronous interference decreases at higher data rates; and (4) MLS receiver susceptibility to propeller modulation depends upon the dynamic response of the receiver automatic gain control and the respective tracking loops.

Pope, J. M.↗

A multichannel implantable telemetry system for flow, pressure, and ECG measurements

The design, principles of operation, and performance of an implantable miniaturized (48 cu cm in volume) multiplex telemetry system for simultaneous measurement of up to eight physiological parameters (including cardiovascular data) are described. Integrated circuits are used to reduce the size, complexity, and cost of fabrication. Power consumption is reduced using recently developed complementary MOS devices. PWM technique is selected as it is relatively easy to implement, lends itself to ICs, and provides an accurate means of transmitting data. The system is totally implantable within the chest of a test animal, with no wire penetrating through the skin. It is shown that the described system permits repeated measurement of the physiological effects of a variety of interventions in awake unanesthetized animals.

Fryer, T. B.↗

Unichromatic-carrier color-TV system

Optical system consists of two filter layers with each layer composed of transparent stripes alternating with dichroic color filter strips. System produces color multiplexed light signal by vertically orienting dichroic filter stripes perpendicular to scan lines of image tube.

Vorhaben, K. H.↗

Fast pressure-sensor system

Miniature silicon-diaphragm sensors and signal multiplexer are mounted to ganged zero-operate-calibrate pressure selector switches. Device allows in-situ calibration, can be computer controlled, and measures at approximately 10,000 readings per second.

Gross, C.↗

Possible methods for USSR-VLF navigation receivers

The U.S.S.R. has a VLF navigation system similar to OMEGA. Beukers has reported some information on the signal format, frequencies used, and the probable radiated power levels. From this data it appears possible to derive receiver operation modes and some implied reasons for the unique choice of the time-multiplexed frequency time base used. Of interest are receiver methods requiring processor gate complexity similar to a digital wristwatch including the use of mass-produced low frequency quartz crystal reference oscillators. The stability required of the local reference oscillator is probably much less critical than for other VLF receivers because of the signal format. One conclusion is that U.S.S.R.-VLF receivers might be fabricated at quite low cost making it possible for all persons in remote areas each to have his own private positioning aid. Further study of the actual transmitted signal format is warranted. While the nature of this memorandum is speculative because of the lack of confirming data, the receiver method proposed has evolved from related principles which have been applied to the operating OMEGA-VLF navigation system.

Burhans, R. W.↗

Apollo experience report: Real-time display system

The real time display system used in the Apollo Program is described; the systematic organization of the system, which resulted from hardware/software trade-offs and the establishment of system criteria, is emphasized. Each basic requirement of the real time display system was met by a separate subsystem. The computer input multiplexer subsystem, the plotting display subsystem, the digital display subsystem, and the digital television subsystem are described. Also described are the automated display design and the generation of precision photographic reference slides required for the three display subsystems.

Sullivan, C. J.↗

Integrated source and channel encoded digital communication system design study

The results of several studies Space Shuttle communication system are summarized. These tasks can be divided into the following categories: (1) phase multiplexing for two- and three-channel data transmission, (2) effects of phase noise on the performance of coherent communication links, (3) analysis of command system performance, (4) error correcting code tradeoffs, (5) signal detection and angular search procedure for the shuttle Ku-band communication system, and (6) false lock performance of Costas loop receivers.

Huth, G. K.↗

Evaluation of several navigation algorithms for application to general aviation

Using data obtained in flight, three position determining algorithms for use by general aviation aircraft were evaluated representing increasing software requirements. These were a DME only, DME/air data and blended DME/air data. Although each step represented additional software with resultant increase in position accuracy, all could be performed on a programmable electronic desk calculator. Results from the computation of aircraft position using the three algorithms are presented. The algorithms employed can be extended to accept VOR, TACAN bearing, ADF, or other NAVAID Data. To obtain the flight data an experimental system was configured and flown on a general aviation aircraft. Principal hardware elements (all with low-cost potential) were a programmable calculator, a single DME receiver (multiplexed for multiple DME use) and a low-cost air speed sensor (shed-vortex principle). The flight test demonstrated satisfactory performance of these principal elements.

Conrad, B.↗

Hadamard transform imager and imaging spectrometer

An imager and a spectrometric imager, which achieve multiplexing by the use of binary optical encoding masks, have been built and tested. The masks are based on orthogonal, pseudorandom digital codes derived from Hadamard matrices. The spatial (and/or spectral) data are therefore obtained in the form of a Hadamard transform of the spatial (and/or spectral) scene. Computer algorithms are used to decode the data and reconstruct images of the original scene. The hardware, algorithms processing and display facility are described. A number of spatial and spatial/spectral images, obtained in the laboratory, are presented.

Swift, R. D.↗

The geostationary operational environmental satellite /GOES/ imaging communication system

The SMS/GOES Satellite obtains day and night weather information from synchronous geostationary orbit by means of (1) earth imaging, (2) collection of environmental data from ground based sensors, platforms, and (3) monitoring of the space environment. SMS-1 and SMS-2 have been in orbit for 17 months and 8 months, respectively, and are presently taking full earth disk images in the visible and infrared every 30 minutes. SMS-1 is positioned to cover the eastern portion of the U.S. while SMS-2 is positioned to cover the western portion. This paper provides a general overview of the imaging communication portions of the SMS/GOES, related to the image data encoding and transmission as well as the method of the data time multiplexing and the manner in which the scan line to line synchronization is achieved.

Baker, W. L.↗

Contribution of the Spacelab data management system to lower cost space research

This paper reviews the design and operation of the Spacelab data management system as it has evolved. Significant improvements and extensions of the original baseline system have been incorporated and will be discussed. They include the capability for the remote control of Spacelab subsystems, improved remote data acquisition units, a high-rate digital data multiplexer, and an improved high-rate digital recorder. Emphasis will be placed on the overall system aspects, including considerations on the use of minicomputers as an adjunct to the basic Spacelab data system. The approach for experiment related software production and integration will be addressed as well. The paper focuses on the contributions of the data management system in reducing the cost of research in Spacelab.

Burger, J. J.↗

Multichannel implantable telemetry system

Multiplexed biotelemetry system for animal research combines several power-saving features. Implantable sensor measures up to eight parameters simultaneously, including blood flow. Microamp transistors, switching circuits, and CMOS technology are used to lower power requirements. However, when blood flow is monitored, these measures are insufficient to reduce power enough for long-term operation from implantable primary battery.

Fryer, T. B.↗

Twisted shield-pair transmission line

Lightweight cable forms balanced transmission line and replaces costlier coaxial cables for multiplex-signal transmission. Cable is fabricated with carefully-controlled electrical characteristics and functions without tuning networks at frequencies up to 10 MHz.

Lind, W. N.↗

A CCD integrated circuit for transient recorders

A 50 MHz CCD integrated circuit is described that was developed for use in transient analog signal recorders to sample and time expand transient signals. The integrated circuit achieves an effective 200 MHz sample rate by using four 32 stage peristaltic CCDs to sample the transient signal four times each clock period. Dual frequency, 4 phi clocking is used to sample and time expand the sampled data. The output signals of the four CCDs are multiplexed on chip into a single low frequency output data line. When operated with 50 MHz/165 KHz 4 phi clocks, this circuit has a 200 MHz sample rate, a record length of 640 nanoseconds, a time expansion factor of 303, and overall signal to noise ratio of 40:1. The signal to noise ratio is limited by fixed pattern noise of the four CCDs.

Balch, J. W.↗

A CCD scanned (Hg, Cd)Te array for earth viewing applications

A 9 channel demonstration of 10 micrometer photoconductive mercury cadmium telluride detector array, bipolar preamplifiers, and a Si CCD multiplexer, integrated into a focal plane assembly and operating at 105 K and at 17 Hz is reported. The result of a direct coupling experiment between a 5-micrometer photovoltaic mercury cadmium telluride photodiode and a CCD is revealed. No appreciable degradation in the signal-to-noise ratio was experienced.

Iwasa, S.↗

Study to investigate and evaluate means of optimizing the Ku-band communication function for the space shuttle

The forward link of the overall Ku-band communication system consists of the ground- TDRS-orbiter communication path. Because the last segment of the link is directed towards a relatively low orbiting shuttle, a PN code is used to reduce the spectral density. A method is presented for incorporating code acquisition and tracking functions into the orbiter's Ku-band receiver. Optimization of a three channel multiplexing technique is described. The importance of Costas loop parameters to provide false lock immunity for the receiver, and the advantage of using a sinusoidal subcarrier waveform, rather than square wave, are discussed.

Simon, M. K.↗