Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mass”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Determination of the mass of globular cluster X-ray sources

The precise positions of the luminous X-ray sources in eight globular clusters have been measured with the Einstein X-Ray Observatory. When combined with similarly precise measurements of the dynamical centers and core radii of the globular clusters, the distribution of the X-ray source mass is determined to be in the range 0.9-1.9 solar mass. The X-ray source positions and the detailed optical studies indicate that (1) the sources are probably all of similar mass, (2) the gravitational potentials in these high-central density clusters are relatively smooth and isothermal, and (3) the X-ray sources are compact binaries and are probably formed by tidal capture.

Grindlay, J. E.↗

Satellite Masses in the Uranus and Neptune Systems

Satellite masses are derivation with emphasis on implications for bulk densities and albedos is reviewed. In the Uranian system the inner satellites have lower densities and/or higher albedos than the outer ones. However, uncertainties are great enough that all five satellites may have nearly equal densities. In such a case the albedo would decrease with semimajor axis. A more severe constraint is placed on Miranda's mass, and hence on its density and albedo. The recent radiometric value for Triton's diameter, combined with mass determinations, yields a density greater than 4 gm/cu cm.

Greenberg, R.↗

Mass analysis of neutral particles and ions released during electrical breakdowns on spacecraft surfaces

Charged-particle fluxes from breakdown events were studied. Methods to measure mass spectra and total emitted flux of neutral particles were developed. The design and construction of the specialized mass spectrometer was completed. Electrical breakdowns were initiated by a movable blunt contact touching the insulating surface. The contact discharge apparatus was used for final development of two different high-speed recording systems and for measurements of the composition of the materials given off by the discharge. It was shown that intense instantaneous fluxes of neutral particles were released from the sites of electrical breakdown events. A laser micropulse mass analyzer showed that visible discoloration at breakdown sites were correllated with the presence of iron on the polymer side of the film, presumably caused by punch-through to the Inconel backing. Kapton samples irradiated by an oxygen ion beam were tested. The irradiated samples were free of surface hydrocarbon contamination but otherwise behaved in the same way as the Kapton samples tested earlier. Only the two samples exposed to oxygen ion bombardment were relatively clean. This indicates an additional variable that should be considered when testing spacecraft materials in the laboratory.

Kendall, B. R. F.↗

Greenland Ice Sheet Mass Balance

Mass balance equation for glaciers; areal distribution and ice volumes; estimates of actual mass balance; loss by calving of icebergs; hydrological budget for Greenland; and temporal variations of Greenland mass balance are examined.

Reeh, N.↗

Research opportunities in loss of red blood cell mass in space flight

Decreases of red blood cell mass and plasma volume have been observed consistently following manned space flights. Losses of red cell mass by United States astronauts have averaged 10 to 15% (range: 2 to 21%). Based on postflight estimates of total hemoglobin, Soviet cosmonauts engaged in space missions lasting from 1 to 7 months have exhibited somewhat greater losses. Restoration of red cell mass requires from 4 to 6 weeks following return to Earth, regardless of the duration of space flight.

Talbot, J. M.↗

Mass spectrometry technology at the Jet Propulsion Laboratory (JPL)

Recent developments in the field of mass spectrometry taking place at the Caltech Jet Propulsion Laboratory are highlighted. The pertinent research and development is aimed at producing an ultrahigh sensitivity mass spectrograph for both spaceflight and terrestrial applications. The unique aspect of the JPL developed technology is an integrating focal plane ion detector that obviates the need for spectral scanning since all ions over a wide mass range are monitored simultaneously. The ion detector utilizes electro-optical technology and is therefore referred to as an Electro-Optical Ion Detector (EOID). A technical description of the JPL MS/EOID, some of the current applications, and its potential benefits for internal contamination analysis are discussed.

Giffin, C. E.↗

Brief search for low-mass objects

Observations of the nearby white dwarfs EG 5 (van Maanen 2) and EG 290 obtained in the J, H, K, L, L-prime, and M bands using an RC1 photometer at the Cassegrain focus of the 3.3-m IR telescope at Mauna Kea on Dec. 2, 1983 are reported. The L-band fluxes are analyzed to search for low-mass companion objects, but none is found. Upper limits of Te = 850 K and L = 5 x 10 to the -6th solar luminosity are established for the putative companions of both dwarfs, corresponding to a mass of 0.027 solar mass or less for an age of 3 Gyr.

Krishna Kumar, C.↗

Particle erosion mechanisms and mass redistribution in Saturn's rings

A variety of physical processes can erode the surfaces of planetary ring particles. According to current estimates, the most efficient of these over the bulk of Saturn's rings is hypervelocity impact by 100 microns to one centimeter radius meteoroids. The atoms, molecules, and fragments ejected from ring particles by erosion arc across the rings along elliptical orbits to produce a tenuous halo of solid ejecta and an extensive gaseous atmosphere. Continuous exchange of ejecta between different ring regions can lead to net radial transport of mass and angular momentum. The equations governing this ballistic transport process are presented and discussed. Both numerical and analytic studies of idealized ring systems illustrate that ballistic transport can cause significant mass redistribution in the rings, especially near regions of high density contrast, such as the inner edges of the A and B rings. Ejecta exchanges can also alter local particle sizes and compositions and may produce pulverized regoliths at least several centimeters deep. The meteoroid erosion rate is so high that significant global torques and mass loss are possible on times shorter than a solar system life time.

Durisen, R. H.↗

Satellite measurement of aerosol mass over land

The estimation of aerosol optical thickness and mass from satellite observations over land is demonstrated using data from the GOES Visible/IR Spin-Scan Radiometer for the eastern U.S. The post-launch calibration technique is described; the algorithm used to derive optical thickness from the radiance of scattered sunlight (by means of a radiative-transfer model in which the optical characteristics of the aerosol are assumed) is presented; and data on aerosol S for July 31, 1980 are analyzed. The results are presented in a series of graphs and maps and compared with ground-based data. The errors in the optical thickness and columnar mass are estimated as 15 and 40 percent, respectively, and the need for independent-data-set validation of satellite-based mass, transport, and divergence values is indicated.

Fraser, R. S.↗

The non-mass-dependent oxygen isotope effect in the electrodissociation of carbon dioxide - A step toward understanding NoMaD chemistry

A non-mass dependent (NoMaD) oxygen isotope effect is demonstrated in the dissociation of CO2 similar to that observed in the electrosynthesis of ozone. The molecular oxygen produced carries the signature of two separate isotopic fractionation processes; a mass-dependent fractionation probably due to CO2 + O isotopic exchange, and a secondary NoMaD fractionation (delta O-17 = 0.97 + or - 0.09 delta O-18, with the O2 depleted in O-17 and O-18). It is suggested that the effect is due to either the formation or relaxation of ozone in an excited electronic state. This represents the latest advance in the understanding of chemical NoMaD effects which may be essential to the explanation of non-mass-dependent fractionations observed in meteorites.

Heidenreich, J. E., III↗

Coronal mass ejections - 1979-1981

An overview of observations of coronal mass ejections (CMEs) during the interval March 28, 1979 through December 31, 1981 is presented. An introduction is first provided to the instrument used in the observations, the method of identifying CMEs, the concepts of CME structural classes, CME importance categories, and the distribution of mass ejections among these classes and categories. The properties of CMEs are given for all mass ejections regardless of their structural classes or importance categories, and then for each class and category. After a brief discussion of the instrument duty cycle, the occurrence rate is presented for all CMEs and for major CMEs, for fast CMEs only, and finally for equatorial CMEs only. The results are compared to those obtained previously.

Howard, R. A.↗

Wave speeds in the corona and the dynamics of mass ejections

A disturbance or coronal mass ejection being advected by the solar wind will expand at the fastest local characteristic speed - typically approximately the fast-mode speed. To estimate this characteristic wave speed and the velocity field in the ambient corona, it is necessary to know the magnetic field, temperature, and density. Only the density is known from coronal observations. The temperature, magnetic field, and velocity are not yet directly measured in the outer corona and must be estimated from a model. In this study, it is estimated that the magnetic field, solar wind velocity, and characteristic speeds use the MHD model of coronal expansion between 1 and 5 solar radii (R solar radii) with a dipole magnetic field at the base. This model, for a field strength of about 2 gauss at the base, gives flow speeds at low latitudes (near the heliospheric current sheet) of 250 km/s at 5 R solar radii and, 50 km/s at 2 solar radii, and fast-mode speeds to 400 to 500 km/s everywhere between 2 and 5 solar radii. This suggests that the outer edge of a velocity of mass ejection reported by MacQueen and Fisher (1983) and implies that the acceleration mechanism for coronal mass ejections is other than simple entrainment in the solar wind.

Suess, S. T.↗

Application of an atmospheric pressure sampling mass spectrometer to chlorination reactions

An atmospheric pressure mass spectrometric sampling system, based on a free jet expansion was used to study certain M-Cl-O reactions at high temperatures. The apparatus enables the volatile species from a 1-atm chemical process to be directly identified with a mass spectrometer which operates at approx. 10 to the minus 8th power torr. Studies for both pure metals and alloys are discussed. It is shown that this mass spectrometer system aids in identifying the volatile species, and provides fundamental information on the reaction mechanism.

Jacobson, N. S.↗

Radionuclide measurements by accelerator mass spectrometry at Arizona

Over the past years, Tandem Accelerator Mass Spectrometry (TAMS) has become established as an important method for radionuclide analysis. In the Arizona system the accelerator is operated at a thermal voltage of 1.8MV for C-14 analysis, and 1.6 to 2MV for Be-10. Samples are inserted into a cesium sputter ion source in solid form. Negative ions sputtered from the target are accelerated to about 25kV, and the injection magnet selects ions of a particular mass. Ions of the 3+ charge state, having an energy of about 9MeV are selected by an electrostatic deflector, surviving ions pass through two magnets, where only ions of the desired mass-energy product are selected. The final detector is a combination ionization chamber to measure energy loss (and hence, Z), and a silicon surface-barrier detector which measures residual energy. After counting the trace iosotope for a fixed time, the injected ions are switched to the major isotope used for normalization. These ions are deflected into a Faraday cup after the first high-energy magnet. Repeated measurements of the isotope ratio of both sample and standards results in a measurement of the concentration of the radionuclide. Recent improvements in sample preparation for C-14 make preparation of high-beam current graphite targets directly from CO2 feasible. Except for some measurements of standards and backgrounds for Be-10 measurements to date have been on C-14. Although most results have been in archaeology and quaternary geology, studies have been expanded to include cosmogenic C-14 in meteorites. The data obtained so far tend to confirm the antiquity of Antarctic meteorites from the Allan Hills site. Data on three samples of Yamato meteorites gave terrestrial ages of between about 3 and 22 thousand years.

Jull, A. J. T.↗

Resonance ionization mass spectrometry for isotopic abundance measurements

Resonance ionization mass spectrometry (RIMS) is a relatively new laser-based technique for the determination of isotopic abundances. The resonance ionization process depends upon the stepwise absorption of photons from the laser, promoting atoms of the element of interest through progressively higher electronic states until an ion is formed. Sensitivity arises from the efficiency of the resonant absorption process when coupled with the power available from commercial laser sources. Selectivity derives naturally from the distinct electronic structure of different elements. This isobaric discrimination has provided the major impetus for development of the technique. Resonance ionization mass spectrometry was used for analysis of the isotopic abundances of the rare earth lutetium. Isobaric interferences from ytterbium severely effect the ability to measure small amounts of the neutron-deficient Lu isotopes by conventional mass spectrometric techniques. Resonance ionization for lutetium is performed using a continuous-wave laser operating at 452 nm, through a sequential two-photon process, with one photon exciting the intermediate resonance and the second photon causing ionization. Ion yields for microgram-sized quantities of lutetium lie between 10(6) and 10(7) ions per second, at overall ionization efficiencies approaching 10(-4). Discrimination factors against ytterbium greater than 10(6) have been measured. Resonance ionization for technetium is also being explored, again in response to an isobaric interference, molybdenum. Because of the relatively high ionization potential for Tc, three-photon, two-color RIMS processes are being developed.

Miller, C. M.↗

The Giotto ion mass spectrometer

The Giotto Ion Mass Spectrometer (IMS) consists of two sensors: one optimized for the outer and the other for the inner coma, with each obtaining complementary information in the region for which it is not optimized. The outer coma is characterized by the interaction between solar wind and comentary plasmas, the inner coma by the outflow of cometary neutrals and their ionization products. Both sensors feature mass imaging characteristics, permitting simultaneous measurements of several ion species by multidetector arrays. Resultant mass-per-charge resolution is greater than or = 20. Energy per charge, and the elevation and aximuth of incident ions are measured. Calibration and in-flight solar-wind data show that the IMS will meet its scientific goals for the Halley encounter.

Balsiger, H.↗

The X-ray signature of solar coronal mass

The coronal response to six solar X-ray flares has been investigated. At a time coincident with the projected onset of the white-light coronal mass ejection associated with each flare, there is a small, discrete soft X-ray enhancement. These enhancements (precursors) precede by typically about 20 m the impulsive phase of the solar flare which is dominant by the time the coronal mass ejection has reached an altitude above 0.5 solar radii. Motions of hot X-ray emitting plasma, during the precursors, which may well be a signature of the mass ejection onsets, are identified. Further investigations have also revealed a second class of X-ray coronal transient, during the main phase of the flare. These appear to be associated with magnetic reconnection above post-flare loop systems.

Harrison, R. A.↗

Mass-loading and the formation of the Venus tail

Despite its lack of intrinsic magnetic field Venus has a well defined magnetotail, containing about 3 megawebers of magnetic flux in a tail about 4 Venus radii across with perhaps a slightly elliptical cross section. This tail arises through the mass-loading of magnetic flux tubes passing by the planet. Mass-loading can occur due to charge exchange and photoionization as well as from the diffusion of magnetic field into the ionosphere. Various evidence exists for the mass-loading process, including the direct observation of the picked up ions with both the Venera and Pioneer Venus plasma analyzers.

Russell, C. T.↗