Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low-frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

AC Magnetic Field Frequency Dependence of Magnetoacoustic Emission

Our recent study has proved a strong correlation between the low-frequency AC applied magnetic field amplitude dependence of the asymmetry of the magnetoacoustic emission (MAE) burst and the strength of the domain wall-defect interaction in iron-base ferromagnets. For the present study the AC magnetic field frequency dependence of the asymmetry has been investigated in the range of 1 to 200 Hz. When represented by the third moment of the rectified acoustic emission pulses, the asymmetry becomes a bell-shaped function of frequency with its center located around 25 Hz. This experiment has been performed with low carbon, high yield stress steel specimens of three different levels of domain wall-defect interaction strength. The results show that the increase in the interaction strength causes a vertical down shift of the asymmetry in the entire frequency range investigated.

Namkung, M.↗

A dynamical model for reflex activated head movements in the horizontal plane

We present a controls systems model of horizontal-plane head movements during perturbations of the trunk, which for the first time interfaces a model of the human head with neural feedback controllers representing the vestibulocollic (VCR) and the cervicocollic (CCR) reflexes. This model is homeomorphic such that model structure and parameters are drawn directly from anthropomorphic, biomechanical and physiological studies. Using control theory we analyzed the system model in the time and frequency domains, simulating neck movement responses to input perturbations of the trunk. Without reflex control, the head and neck system produced a second-order underdamped response with a 5.2 dB resonant peak at 2.1 Hz. Adding the CCR component to the system dampened the response by approximately 7%. Adding the VCR component dampened head oscillations by 75%. The VCR also improved low-frequency compensation by increasing the gain and phase lag, creating a phase minimum at 0.1 Hz and a phase peak at 1.1 Hz. Combining all three components (mechanics, VCR and CCR) linearly in the head and neck system reduced the amplitude of the resonant peak to 1.1 dB and increased the resonant frequency to 2.9 Hz. The closed loop results closely fit human data, and explain quantitatively the characteristic phase peak often observed.

NASA Discipline Neuroscience↗

Fundamental relations between short-term RR interval and arterial pressure oscillations in humans

BACKGROUND: One of the principal explanations for respiratory sinus arrhythmia is that it reflects arterial baroreflex buffering of respiration-induced arterial pressure fluctuations. If this explanation is correct, then elimination of RR interval fluctuations should increase respiratory arterial pressure fluctuations. METHODS AND RESULTS: We measured RR interval and arterial pressure fluctuations during normal sinus rhythm and fixed-rate atrial pacing at 17.2+/-1.8 (SEM) beats per minute greater than the sinus rate in 16 healthy men and 4 healthy women, 20 to 34 years of age. Measurements were made during controlled-frequency breathing (15 breaths per minute or 0.25 Hz) with subjects in the supine and 40 degree head-up tilt positions. We characterized RR interval and arterial pressure variabilities in low-frequency (0.05 to 0.15 Hz) and respiratory-frequency (0.20 to 0.30 Hz) ranges with fast Fourier transform power spectra and used cross-spectral analysis to determine the phase relation between the two signals. As expected, cardiac pacing eliminated beat-to-beat RR interval variability. Against expectations, however, cardiac pacing in the supine position significantly reduced arterial pressure oscillations in the respiratory frequency (systolic, 6.8+/-1.8 to 2.9 +/-0.6 mm Hg2/Hz, P=.017). In contrast, cardiac pacing in the 40 degree tilt position increased arterial pressure variability (systolic, 8.0+/-1.8 to 10.8 +/-2.6, P=.027). Cross-spectral analysis showed that 40 degree tilt shifted the phase relation between systolic pressure and RR interval at the respiratory frequency from positive to negative (9 +/-7 degrees versus -17+/-11 degrees, P=.04); that is, in the supine position, RR interval changes appeared to lead arterial pressure changes, and in the upright position, RR interval changes appeared to follow arterial pressure changes. CONCLUSIONS: These results demonstrate that respiratory sinus arrhythmia can actually contribute to respiratory arterial pressure fluctuations. Therefore, respiratory sinus arrhythmia does not represent simple baroreflex buffering of arterial pressure.

NASA Discipline Cardiopulmonary↗

Comparative transduction mechanisms of hair cells in the bullfrog utriculus. II. Sensitivity and response dynamics to hair bundle displacement

1. Hair cells in whole-mount in vitro preparations of the utricular macula of the bullfrog (Rana catesbeiana) were selected according to their macular location and hair bundle morphology. The sensitivity and response dynamics of selected hair cells to natural stimulation were examined by recording their voltage responses to step and sinusoidal hair bundle displacements applied to their longest stereocilia. 2. The voltage responses of 31 hair cells to sinusoidal hair bundle displacements were characterized by their gains and phases, taken with respect to peak hair bundle displacement. The gains of Type B and Type C cells at both 0.5 and 5.0 Hz were markedly lower than those of Type F and Type E cells. Phases, with the exception of Type C cells, lagged hair bundle displacement at 0.5 Hz. Type C cells had phase leads of 25-40 degrees. At 5.0 Hz, response phases in all cells were phase lagged with respect to those at 0.5 Hz. Type C cells had larger gains and smaller phase leads at 5.0 Hz than at 0.5 Hz, suggesting the presence of low-frequency adaptation. 3. Displacement-response curves, derived from the voltage responses to 5.0-Hz sinusoids, were sigmoidal in shape and asymmetrical, with the depolarizing response having a greater magnitude and saturating less abruptly than the hyperpolarizing response. When normalized to their largest displacement the linear ranges of these curves varied from < 0.5 to 1.25 microns and were largest in Type B and smallest in Type F and Type E cells. Sensitivity, defined as the slope of the normalized displacement-response curve, was inversely correlated with linear range. 4. The contribution of geometric factors associated with the hair bundle to linear range and sensitivity were predicted from realistic models of utricular hair bundles created using morphological data obtained from light and electron microscopy. Three factors, including 1) the inverse ratio of the lengths of the kinocilium and longest stereocilia, representing the lever arm between kinociliary and stereociliary displacement; 2) tip link extension/linear displacement, largely a function of stereociliary height and separation; and 3) stereociliary number, an estimate of the number of transduction channels, were considered in this analysis. The first of these factors was quantitatively more important than the latter two factors and their total contribution was largest in Type B and Type C cells. Theoretical models were also used to calculate the relation between rotary and linear displacement.(ABSTRACT TRUNCATED AT 400 WORDS).

Non-NASA Center↗

Important influence of respiration on human R-R interval power spectra is largely ignored

Frequency-domain analyses of R-R intervals are used widely to estimate levels of autonomic neural traffic to the human heart. Because respiration modulates autonomic activity, we determined for nine healthy subjects the influence of breathing frequency and tidal volume on R-R interval power spectra (fast-Fourier transform method). We also surveyed published literature to determine current practices in this burgeoning field of scientific inquiry. Supine subjects breathed at rates of 6, 7.5, 10, 15, 17.1, 20, and 24 breaths/min and with nominal tidal volumes of 1,000 and 1,500 ml. R-R interval power at respiratory and low (0.06-0.14 Hz) frequencies declined significantly as breathing frequency increased. R-R interval power at respiratory frequencies was significantly greater at a tidal volume of 1,500 than 1,000 ml. Neither breathing frequency nor tidal volume influenced average R-R intervals significantly. Our review of studies reporting human R-R interval power spectra showed that 51% of the studies controlled respiratory rate, 11% controlled tidal volume, and 11% controlled both respiratory rate and tidal volume. The major implications of our analyses are that breathing parameters strongly influence low-frequency as well as respiratory frequency R-R interval power spectra and that this influence is largely ignored in published research.

NASA Discipline Cardiopulmonary↗

Hemodynamic and autonomic nervous system responses to mixed meal ingestion in healthy young and old subjects and dysautonomic patients with postprandial hypotension

BACKGROUND. Although postprandial hypotension is a common cause of falls and syncope in elderly persons and in patients with autonomic insufficiency, the pathophysiology of this disorder remains unknown. METHODS AND RESULTS. We examined the hemodynamic, splanchnic blood pool, plasma norepinephrine (NE), and heart rate (HR) power spectra responses to a standardized 400-kcal mixed meal in 11 healthy young (age, 26 +/- 5 years) and nine healthy elderly (age, 80 +/- 5 years) subjects and 10 dysautonomic patients with symptomatic postprandial hypotension (age, 65 +/- 16 years). Cardiac and splanchnic blood pools were determined noninvasively by radionuclide scans, and forearm vascular resistance was determined using venous occlusion plethysmography. In healthy young and old subjects, splanchnic blood volume increased, but supine blood pressure remained unchanged after the meal. In both groups, HR increased and systemic vascular resistance remained stable. Forearm vascular resistance and cardiac index increased after the meal in elderly subjects, whereas these responses were highly variable and of smaller magnitude in the young. Young subjects demonstrated postprandial increases in low-frequency HR spectral power, representing cardiac sympatho-excitation, but plasma NE remained unchanged. In elderly subjects, plasma NE increased after the meal but without changes in the HR power spectrum. Patients with dysautonomia had a large postprandial decline in blood pressure associated with no change in forearm vascular resistance, a fall in systemic vascular resistance, and reduction in left ventricular end diastolic volume index. HR increased in these patients but without changes in plasma NE or the HR power spectrum. CONCLUSIONS. 1) In healthy elderly subjects, the maintenance of blood pressure homeostasis after food ingestion is associated with an increase in HR, forearm vascular resistance, cardiac index, and plasma NE. In both young and old, systemic vascular resistance is maintained. 2) Dysautonomic patients with postprandial hypotension fail to maintain systemic vascular resistance after a meal. This impairment in vascular response to meal ingestion may underlie the development of postprandial hypotension. 3) The measurement of mean HR or plasma NE does not adequately characterize autonomic cardiac control. Power spectral analysis suggests an impairment in the postprandial autonomic modulation of HR in healthy elderly and dysautonomic subjects, possibly predisposing to hypotension when vascular compensation is inadequate.

Non-NASA Center↗

In vivo assessment of forearm bone mass and ulnar bending stiffness in healthy men

The cross-sectional bending stiffness EI of the ulna was measured in vivo by mechanical resistance tissue analysis (MRTA) in 90 men aged 19-89 years. MRTA measures the impedance response of low-frequency vibrations to determine EI, which is a reflection of elastic modulus E and moment of inertia I for the whole ulna. EI was compared to conventional estimates of bone mineral content (BMC), bone width (BW), and BMC/BW, which were all measured by single-photon absorptiometry. Results obtained from the nondominant ulna indicate that BW increases (r = 0.27, p = 0.01) and ulnar BMC/BW decreases (r = -0.31, p < or = 0.005) with age. Neither BMC nor EI declined with age. The single best predictor of EI was BW (r2 = 0.47, p = 0.0001), and further small but significant contributions were made by BMC (r2 = 0.53, p = 0.0001) and grip strength (r2 = 0.55, p = 0.0001). These results suggest that the resistance of older men to forearm fracture is related to age-associated changes in the moment of inertia achieved by redistributing bone mineral farther from the bending axis. We conclude that the in vivo assessment of bone geometry offers important insights to the comprehensive evaluation of bone strength.

NASA Center ARC↗

A new technique for simultaneous monitoring of electrocardiogram and walking cadence

A new technique for simultaneously recording continuous electrocardiographic (ECG) data and walking step rate (cadence) is described. The ECG and gait signals are recorded on 2 channels of an ambulatory Holter monitor. Footfall is detected using ultrathin, force-sensitive foot switches and is frequency modulated. The footfall signal provides an indication of the subject's activity (walking or standing), as well as the instantaneous walking rate. Twenty-three young and elderly subjects were studied to demonstrate the use of this ECG and gait recorder. High-quality gait signals were obtained in all subjects, and the effects of walking on the electrocardiogram were assessed. Initial investigation revealed the following findings: (1) Although walking rates were similar in young and elderly subjects, the elderly had both decreased heart rate (HR) variability (p < 0.005) and increased cadence variability (p < 0.0001). (2) Overall, there was an inverse relation between HR and cadence variability (r = -0.73). Three elderly subjects with no known cardiac disease had HR and cadence variability similar to those of the young, whereas elderly subjects with history of congestive heart failure were among those with the lowest HR variability and the highest cadence variability. (3) Low-frequency (approximately equal to 0.1 Hz) HR oscillations (frequently observed during standing) persisted during walking in all young subjects. (4) In some subjects, both step rate and HR oscillated at the same low frequency (approximately equal to 0.1 Hz) previously identified with autonomic control of the baroreflex.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Cardiopulmonary↗

Electrophysiology of the mammillary complex in vitro. II. Medial mammillary neurons

1. The electrophysiological properties of guinea pig medial mammillary body (MMB) neurons were studied using an in vitro slice preparation. 2. The neurons (n = 80) had an average resting potential of -57 +/- 5.5 (SD) mV, an input resistance of 176 +/- 83 M omega, and a spike amplitude of 58 +/- 15.7 mV. Most of the neurons were silent at rest (n = 52), but some fired spontaneous single spikes (n = 16) or spike bursts (n = 14). 3. The main electrophysiological characteristic of MMB neurons was the ability to generate Ca(2+)-dependent regenerative events, which resulted in very robust burst responses. However, this regenerative event was not the same for all neurons, ranging from typical low-threshold Ca2+ spikes (LTSs) to intermediate-threshold plateau potentials (ITPs). 4. The ITPs were distinct from the LTSs in that they lasted > or = 100 ms and were not inactivated at membrane potentials at or positive to -55 mV. 5. Some cells with a prominent ITP and no LTS (n = 36) displayed repetitive, usually rhythmic, bursting (n = 14). This ITP could be powerful enough to maintain rhythmic membrane potential oscillations after pharmacological block of Na+ conductances. 6. A group of 32 MMB neurons displayed complex bursting that was generated by activation of both LTSs and ITPs. This was established on the basis of their distinct time- and voltage-dependent characteristics. In a group of neurons (n = 14), the burst responses were exclusively generated by an LTS; however, a Ca(2+)-dependent plateau potential contributed to the generation of rebound-triggered oscillatory firing. 7. In addition to the Ca(2+)-dependent LTS and/or ITP, MMB neurons always displayed high-threshold Ca2+ spikes after reduction of K+ conductances with tetraethylammonium. 8. MMB neurons display one of the richer varieties of voltage-dependent Ca2+ conductances so far encountered in mammalian CNS. We propose that the very prominent endogenous bursting and oscillatory properties of MB neurons allow this nuclear complex to function as an oscillatory relay for the transmission of low-frequency rhythmic activities throughout the limbic circuit.

NASA Discipline Neuroscience↗

Gravitational Wave Search with the Clock Mission (abstract)

Doppler tracking of distant spacecraft is the only method currently available for search for gravitational waves in the low-frequency band. Experiments to date and those planned for the near future all involve.

clocks gravitational waves doppler frequency stand↗

Thermal Stability Analysis for a Heliocentric Gravitational Radiation Detection Mission

The Laser Interferometer Space Antenna (LISA) mission is designed for detailed studies of low-frequency gravitational radiation. The mission is currently a candidate for ESA's post-Horizon 2000 program. Thermal noise affects the measurement in at least two ways. Thermal variation of the length of the optical cavity to which the lasers are stabilized introduces phase variations in the interferometer signal, which have to be corrected for by using data from the two arms separately.

Laser Interferometer Space Antenna LISA gravitatio↗

(abstract) Spacecraft Doppler Tracking with the Deep Space Network in the Search for Gravitational Waves

The Deep Space Network generates accurate radio science data observables for investigators who use radio links between spacecraft and the Earth to examine small changes in the phase and/or amplitude of the signal to study a wide variety of structures and phenomena in space. Several such studies are directed at aspects of the theory of general relativity such as gravitational redshift and gravitational waves. A gravitational wave is a propagating, polarized gravitational field, a ripple in the curvature of space-time. In Einstein's theory of general relativity, the waves are propagating solutions of the Einstein field equations. Their amplitudes are dimensionless strain amplitudes that change the fractional difference in distance between test masses and the rates at which separated clocks keep time. Predicted by all relativistic theories of gravity, they are extremely weak (the ratio of gravitational forces to electrical forces is about 10(sup -40)) and are generated at detectable levels only by astrophysical sources - very massive sources under violent dynamical conditions. The waves have never been detected but searches in the low-frequency band using Doppler tracking of many spacecraft have been conducted and others are being planned. Upper limits have been placed on the gravitational wave strength with the best sensitivities to date are for periodic waves being 7 x 10(sup -15).

gravitational waves theory of general relativity D↗

Interplanetary Scintillation

Interplanetary scintillation (IPS) has been used as a diagnostic of solar wind speed and interplanetary plasma turbulence, allowing inference of speed and electron density power spectrum close to the Sun and out of the ecliptic. In that context, IPS is 'signal' and provides scientifically interesting data. IPS is also of interest because amplitude and phase perturbations imposed on radio waves are 'noise' for telemetry and precision Doppler tracking of deep space probes and for some radio astronomical observations. This paper briefly reviews the connection between scattering observables and the electron density power spectrum. Interplanetary phase scintillation on time scales of 100 to 10 000 seconds is an important noise in mass determinations of small solar system bodies during space-probe fly-bys and in searches for low-frequency gravitational radiation.

waves deep space probes electron density power spe↗

(abstract) System Performance of the Joint Galileo/Mars Observer/Ulysses 1993 Gravitational Wave Experiment

From March 21 to April 11, 1993, the Galileo, Mars Observer, and Ulysses spacecraft were tracked almost continuously in a coincidence experiment to search for low-frequency (~millihertz) gravitational radiation. We report here a first statistical assessment of the noise characteristics of the data, with particular attention to the performance of the radio science instrumentation itself.

gravitational waves radio science noise Doppler ef↗

Airflow sensing system

Disclosed is an airflow sensing system for determining the type of airflow flowing over a flight surface. A hot film sensor is driven by a constant voltage feedback circuit that maintains the voltage across the sensor at a predetermined level. A signal processing circuit receives an output signal of the feedback circuit and determines whether the output signal is indicative of laminar, transitional or turbulent airflow. Transitional airflow is distinguished from turbulent airflow by a signal having significant energy in a low-frequency passband from 50-80 Hz. The signal processing circuit drives a three-color LED display to provide a visual indication of the type of airflow being sensed.

Gelbach, Herman R.↗

Fermilab PIP II machine protection system digitized data noise elimination scheme and its FPGA implementation

In Fermilab's PIP-II machine protection system, beam loss signals from various detectors are digitized at 125 MS/s. Noise from both high-frequency sources and low-frequency 60 Hz AC power equipment can contaminate the data. To suppress noise across these ranges especially 60 Hz and its harmonics, which overlap with beam loss signal frequencies advanced digital processing beyond standard filtering is required. Several real-time functional blocks were simulated and tested on an FPGA: (1) a dual time-constant discharging integrator filter, (2) a de-ripple baseline extraction and storage block, and (3) a fast-recovery discharging integrator. The nonlinear IIR integrator filter removes high-frequency noise and feeds into the baseline extractor. Upon detecting abrupt beam loss, it switches to a longer time constant to prevent baseline distortion. The de-ripple block calculates a valid baseline by averaging over multiple 60 Hz periods, storing results in a 4096-word FPGA RAM. This baseline is subtracted from raw data before integration by the fast-recovery block, which resets quickly after use. All blocks achieved expected performance.

Wu, J. [Fermilab] (ORCID:0000000344329521)↗

A stable potential-based time-domain method for wideband elec- tromagnetic analysis

In previous research, the frequency-domain A-ϕ formulation has been validated using the finite element method for electromagnetic simulations of low-frequency and multi- scale problems, demonstrating excellent numerical accuracy, good matrix condition, and high computational efficiency. Time- domain simulations provide significant advantages for modeling wideband problems and are crucial for multiphysics applications. In this paper, the frequency-domain A-ϕ formulation is extended to the time domain. The central difference scheme is employed for temporal discretization to ensure both accuracy and stability. A numerical example is presented to demonstrate the capability of the proposed time-domain method in wideband electromagnetic analysis.

Mekonnen, Minyichil↗

Strong-Drive Limits in Josephson Circuits: From Chaos to an Unbound-Resonance Threshold

Strong microwave drives enable fast measurement and parametric control in superconducting circuits but can induce transitions out of the intended low-energy manifold. We develop a unified description of strong-drive limits in flux- and charge-driven Josephson circuits across drive frequency and dc flux bias. Using classical phase-space analysis and Floquet--Markov simulations, we identify distinct low- and high-frequency mechanisms. At low frequency, we characterize bound-state resonances and separatrix chaos and find that the flux-drive chaos threshold depends strongly on dc flux bias. At high frequency, these mechanisms are suppressed, and the dissipative steady state transfers from the central bound-state sector to outer resonances formed by above-barrier running trajectories. The resulting unbound-resonance threshold is nearly independent of drive frequency and circuit parameters over the regime studied and is controlled primarily by dc flux bias. Coherent simulations show that parametric operation persists beyond this threshold, but at a reduced rate, setting an effective upper bound on the achievable operation speed. We derive analytical criteria for both thresholds, validate them numerically, and experimentally confirm the predicted dc-bias dependence of the low-frequency threshold in a flux-driven SQUID. We also determine the timescales for transfer into the unbound-resonance regime and relaxation back to the bound-state manifold after the drive is removed. Finally, we relate the stability limits to a complementary picture based on the junction critical current and extend the framework to multitone drives and inductively shunted circuits. Together, these results identify the mechanisms limiting strong driving and suggest routes to extend the stable operating range of Josephson circuits.

You, Xinyuan [Fermilab] (ORCID:0000000291789419)↗