Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Development of pulsed processes for the manufacture of solar cells

Low-energy ion implantation processes for the automated production of silicon solar cells were investigated. Phosphorus ions at an energy of 10 keV and dose of 2 x 10 to the 15th power/sq cm were implanted in silicon solar cells to produce junctions, while boron ions at 25 keV and 5 x 10 to the 15th power were implanted in the cells to produce effective back surface fields. An ion implantation facility with a beam current up to 4 mA and a production throughput of 300 wafers per hour was designed and installed. A design was prepared for a 100 mA, automated implanter with a production capacity of 100 MW sub e/sq cm per year. Two process sequences were developed which employ ion implantation and furnace or pulse annealing. A computer program was used to determine costs for junction formation by ion implantation and various furnace annealing cycles to demonstrate cost effectiveness of these methods.

Minnucci, J. A.↗

Economy of precipitating agent application in municipal wastewater treatment facilities

Purification by precipitation in this study is not considered primarily as a means of phosphate removal but as a method for reduction of suspended solids BOD and COD. A dynamic calculation procedure is used to allow for exact determination of time dependent variation of costs. The results show that costs of wastewater treatment by precipitation may equal those of conventional primary clarification and secondary biological treatment, especially with low-cost iron-II-salts in simultaneous precipitation and in larger plants ( 20,000 PF). Cost advantages may be accrued in smaller plants by using the more expensive trivalent salts in pre-precipitation as compared to conventional low-load biological treatment. This is due mainly to better effluent quality and, consequently, lower wastewater fees (Wastewater Discharge Act). If the precipitant is dosed temporarily only during periods of highest pollution the savings can be about 5 to 10%.

Neis, U.↗

Monitoring and Modeling Astronaut Occupational Radiation Exposures in Space: Recent Advances

In 1982 astronauts were declared to be radiation workers by OSHA, and as such were subject to the rules and regulations applied to that group. NASA was already aware that space radiation was a hazard to crewmembers and had been studying and monitoring astronaut doses since 1962 at the Johnson Space Center. It was quickly realized NASA would not be able to accomplish all of its goals if the astronauts were subject to the ground based radiation worker limits, and thus received a waiver from OSHA to establish independent limits. As part of the stipulation attached to setting new limits, OSHA included a requirement to perform preflight dose projections for each crew and inform them of the associated risks. Additional requirements included measuring doses from various sources during the flight, making every effort to prevent a crewmember from exceeding the new limits, and keeping all exposures As Low As Reasonably Achievable (a.k.a. ALARA - a common health physics principle). The assembly of the International Space Station (ISS) and its initial manned operations will coincide with the 4-5 year period of high space weather activity at the next maximum in the solar cycle. For the first time in NASA's manned program, US astronauts will be in orbit continuously throughout a solar maximum period. During this period, crews are at risk of significantly increased radiation exposures due to solar particle events and trapped electron belt enhancements following geomagnetic storms. The problem of protecting crews is compounded by the difficulty of providing continuous real-time monitoring over a period of a decade in an era of tightly constrained budgets. In order to prepare for ISS radiological support needs, the NASA Space Radiation Analysis Group and the NOAA Space Environment Center have undertaken a multiyear effort to improve and automate ground-based space weather monitoring systems and real-time radiation analysis tools. These improvements include a coupled, automated space weather monitoring and alarm system--SPE exposure analysis system, an advanced space weather data distribution and display system, and a high-fidelity space weather simulation system. In addition, significant new real-time space weather data sets, which will enhance the forecasting and now-casting of near-Earth space environment conditions, are being made available through unique NASA-NOAA-USAF collaborations. These new data sets include coronal mass ejection monitoring by the Solar and Heliospheric Observatory (SOHO) and in-situ plasma and particle monitoring at the L1 libration point by the Solar Wind Monitor (SWIM) and Advanced Composition Explorer (ACE) spacecraft. Advanced real-time radiation monitoring data from charged particle telescopes and tissue equivalent proportional counters will also be available to assist crew and flight controllers in monitoring the external and intravehicular radiation environment.

Weyland, Mark↗

Passive dosimetry aboard the Mir Orbital Station: external measurements

This paper reports results from the first measurements made on the exterior of a LEO spacecraft of mean dose equivalent rate and average quality factor as functions of shielding depth for shielding less than 1 g/cm2 Al equivalent. Two sets of measurements were made on the outside of the Mir Orbital Station; one near solar maximum in June 1991 and one near solar minimum in 1997. Absorbed dose was measured using stacks of TLDs. LET spectrum from charged particles of LET infinity H2O > o r= 5keV/micrometers was measured using stacks of CR-39 PNTDs. Results from the TLD and PNTD measurements at a given shielding depth were combined to yield mean total dose rate, mean dose equivalent rate, and average quality factor. Measurements made near solar maximum tend to be greater than those made during solar minimum. Both mean dose rate and mean dose equivalent rate decrease by nearly four orders of magnitude within the first g/cm2 shielding illustrating the attenuation of both trapped electrons and low-energy trapped protons. In order to overcome problems with detector saturation after standard chemical processing, measurement of LET spectrum in the least shielded CR-39 PNTD layer (0.005 g/cm2 Al) was carried out using an atomic force microscope. c2002 Elsevier Science Ltd. All rights reserved.

manned↗

Induction of micronuclei in human fibroblasts across the Bragg curve of energetic heavy ions

The space environment consists of a varying field of radiation particles including high energy ions, with spacecraft shielding material providing the major protection to astronauts from harmful exposure. Unlike low-L or X-rays, the presence of shielding does not always reduce the radiation risks for energetic charged particle exposure. Although the dose delivered by the charged particle increases sharply as the particle approaches the Bragg peak, the Bragg curve does not necessarily represent the biological damage along the particle traversal. The "biological Bragg curve" is dependent on the energy and the type of the primary particle, and may vary for different biological endpoints. To investigate "biological Bragg curves", we analyzed micronuclei (MN) induction along the particle traversal of Si and Fe ions at incident energies of 300 MeV/nucleon and 1 GeV/nucleon. A quantitative biological response curve did not reveal an increased yield of MN at the location of the Bragg peak. However, the ratio of mono-to bi-nucleated cells, which indicates inhibition in cell progression, increased at the Bragg peak location. These results confirm the hypothesis that "over kill" at the Bragg peak will affect the outcome of other biological endpoints.

Hada, Megumi↗

Twenty Years of Radiation Measurements in Low-Earth Orbit - What Have We Learned Space Radiation Environment?

The advent of the Space Shuttle program has made possible space radiation environment measurements spanning a wide range of altitudes and orbital inclinations over multiple solar cycles. These measurements range from routine integral dose measurements with thermoluminescent dosimeters to particle energy spectra measurements made with a charged particle telescope. This paper will review the new understanding about the space radiation environment gained from this diverse data set. Major findings from these measurements include: estimations of the westward drift rate of the South Atlantic Anomaly (SAA) of 0.28-0.49/y; evidence for a northward component to the SAA drift of 0.08-0.12/y; observation of the formation and decay of the pseudo-stable additional radiation belt following the Mar 1991 SPE and geomagnetic storm with an estimated decay e-folding time of 9-10 months; observation of a local geomagnetic east-west trapped proton exposure anisotropy with an estimated magnitude of 1.6-3.3; demonstration that the trapped proton exposure in low-Earth orbit (LEO) can be reasonably modeled as a power law function of atmospheric density in the SAA region, with best correlations obtained when the exospheric temperature saturates at 938-975 K; the actual solar cycle modulation of trapped proton exposure in LEO is less than predicted by the AP8 model; and the testing and validation of GCR flux models, radiation transport codes, and dynamic geomagnetic cutoff models. Long-term, time-resolved proportional counter measurements made aboard the Mir during the same period provides further demonstration of the solar cycle modulation of the trapped protons at low altitudes - the observed modulation is also well described as power law function of atmospheric density. These data and findings have helped to improve the overall accuracy of pre-mission crew exposure projections using various semi-empirical space environment models, radiation transport codes, and spacecraft radiation shielding models. During the rise phase of solar cycle 22 (1987-1991), the RMS error between preflight exposure projections and measured crew exposure was 73%. For the rise phase of cycle 23 (1997-2001), the preflight exposure projection RMS error has decreased to 23%. The launch and assembly of the Space Station has begun a new era of long-term LEO space environment monitoring. The radiation environment at the Space Station will be monitored with three external charged particle telescopes oriented in the velocity vector, anti-velocity vector, and zenith directions. Data from the telescopes will provide charge, mass, energy, and arrival direction for incident particles with energy to mass ratios of 13- 450 MeV/amu and Z of 1-24. The external environment data will be complimented by measurements from a portable charged particle telescope and proportional counter located inside the vehicle.

Golightly, Michael J.↗

Radiation hard gallium oxide scintillators for high count rate radiation detection

Despite decades of materials research, the availability of appropriate crystalline radiation-hard scintillators with ultrafast decay times (~10ns) and high light yields (>2000 ph/MeV) are still limited. In this study, we demonstrate the potential of gallium oxide (β-Ga 2 O 3 ) based scintillators for high count rate applications. The low-cost rugged β-Ga 2 O 3 scintillators were grown using the optical float zone (FZ) technique. Several dopants and growth atmospheres were used to demonstrate the balance between ultrafast primary decay time and the light yield of the scintillators. Light yields as high as 6446 ± 716 ph/MeV were obtained with 18.3 ns decay time for 662 keV gamma rays. Decay times as fast as 12ns were obtained with a 3212 ± 357 ph/MeV light yield. An excellent 662 keV gamma energy resolution of 7% was obtained using the β-Ga 2 O 3 :Ce crystals. Even with these excellent scintillation properties, the gamma radiation hardness of β-Ga 2 O 3 crystals was better than the leading radiation-hard lead tungstate (PbWO 4 ) crystals. Twenty-six scintillators fabricated from the grown β-Ga 2 O 3 crystals were tested for radiation hardness with a 60 Co gamma irradiation rate of 14 krad/h with a total radiation dose of 2 Mrad. The scintillation properties of these crystals remained unaffected. To date, no other scintillator has demonstrated such high radiation resistance. Furthermore, these FZ-grown low-cost, non-hygroscopic, and high-density β-Ga 2 O 3 scintillators can replace the existing scintillators in many applications ranging from nuclear and high energy physics experiments to nuclear security.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo simulation of shielding designs for a cabinet form factor preclinical MV–energy photon FLASH radiotherapy system

Purpose: A preclinical MV-energy photon FLASH radiotherapy system is being designed at Stanford and SLAC National Accelerator Laboratory. Because of the higher energy and dose rate compared to conventional kV-energy photon laboratory-scale irradiators, adequate shielding in a stand-alone cabinet form factor is more challenging to achieve. We present a Monte Carlo simulation of multilayered shielding for a compact self-shielding system without the need for a radiation therapy vault. Methods: A multilayered shielding approach using multiple alternating layers of high-Z and low-Z materials is applied to the self-shielded cabinet to effectively mitigate the secondary radiation produced and to allow the device to be housed in a Controlled Radiation Area outside of a radiation vault. The multilayered shielding approach takes advantage of the properties of high-Z and low-Z radiation shielding materials such as density, cross-section, atomic number of the shielding elements, and products of radiation interactions within each layer. The Monte Carlo radiation transport code, FLUKA, is used to simulate the total effective dose produced by the operation. Results: The multilayered shielding designs proposed and simulated produced effective dose rates significantly lower than monolayer designs with the same total material thickness at the regulatory boundary; this is accomplished through the manipulation of the locations where secondary radiation is produced and reactions due to material properties such as neutron back reflection in hydrogen. Borated polyethylene at 5 wt% significantly increased the shielding performance as compared to regular polyethylene, with the magnitude of the reduction depending upon the order of the shielding material. Conclusions: The multilayered shielding provides a path for shielding preclinical FLASH systems that deliver MV-energy bremsstrahlung photons. Furthermore, this approach promises to be more efficient with respect to the shielding material mass and space claim as compared to shielded vaults typically required for clinical radiation therapy with MV photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving Efficacy and Safety of Pharmacological Treatment Through Precision Medicine and Pharmacogenomics for Human Deep Space Exploration

INTRODUCTION: Future spaceflight will require increased crew medical autonomy as exploration class missions expanding duration and distance from Earth, especially for Mars missions. As mission duration increases, it will be even more essential to have appropriate amounts of effective medication to ensure the maintenance of crew health and performance. Conversely, mass and volume constraints will become more severe as future spaceflight expands beyond low Earth orbit, where resupply is difficult or becomes impossible. These constraints thus convey an urgency to further tailor medications included in the spacecraft formulary and increased examination of appropriate dosing regimens. BACKGROUND: Precision Health is an exciting area of cutting-edge research and medicine focused on maintaining an individual’s health and performance through in-depth understanding of an individual’s unique factors and molecular profiles. This approach can be adapted to better predict, monitor, and address physiological responses to the spaceflight environment. One example is the field of pharmacogenomics (PGX),the study of how the expressed genome impacts drug responses with the goal of prescribing the right dose of the right drug at the right time. Specifically, PGX testing provides valuable information on an individual’s precise allelic variations to guide physicians in making informed decisions on pharmaceutical choice and dosing to avoid adverse drug events and maximize pharmacological efficacy. The goal of this study was to evaluate which drugs in the current space pharmacy could be evaluated using PGX testing and to understand the potential impact on the health and wellness of the astronaut population. Additionally, we sought to evaluate clinically available FDA-approved PGX testing solutions to better understand its applicability. METHODS: A complete list of drugs onboard the International Space Station (ISS) was analyzed for risk and likelihood of drug failure and PGX actionability. This analysis encompassed both personal astronaut medications, including supplements and over the counter drugs (n=151) and ISS MedKit formulary medications (n=95). Duplicate medications and different formulations were removed, which resulted in 157 total drugs used in the subsequent analysis. A 5x5 risk assessment table was produced by examining the likelihood of drug failure compared to the consequence of drug failure. Likelihood of individual drug failure was defined by whether existing processes are sufficient to prevent adverse events, as ranked from 1 (very low, can easily be prevented) to 5 (very high, cannot be prevented) during a Mars mission. In contrast, the consequence of drug failure was defined by impact to safety, schedule, cost or technical and ranked from 1 (very low) to 5 (very high).A comprehensive assessment of commercially available PGX solutions is currently underway to evaluate specimen requirements, cost/benefit analysis (cost vs. number of alleles assessed), utility of variant analysis, relevance to inflight medication usage, quality of reporting in enabling clinical application, and ease of integration into electronic medical records. RESULTS: Risk assessments(LxC 5x5 table) indicated29medicationswere in the yellow or red zone driven predominantly by drug failure or safety concerns, with the remainder(n=128)of the medications in the green zone where risk is acceptable. We found that current PGX testing results could impact 21% of the total medications in the ISS MedKit and IMAK; of these, 9 medications currently have direct clinically actionable guidance available. Results of the clinical PGX solution evaluations as related to these medications will be presented. CONCLUSION: PGX testing has demonstrated clear benefits in terrestrial medicine and clinical environments for the selection of proper medications, avoiding adverse drug reactions, and maximizing drug efficacy. We propose that similar benefits would be bestowed on the astronaut and commercial spaceflight passenger population by performing preemptive pre-flight PGX testing to reduce risk of mission failure due to ineffective or toxic medications, improve targeting drug efficacy and safety, and further open the door to countermeasure research exploring PGX-related allelic variants. For example, PGX results could allow tailoring of specific medications at optimal doses more precisely to each individual astronaut, particularly in areas of space motion sickness, sleep aids, and analgesics. An additional benefit is that PGX results could provide information for better planning of the components of a space pharmacy for deep space missions to be more cost effective and more efficient in the utilization of limited pharmaceutical resources. Finally, while PGX testing of the astronaut corps is not currently conducted, this approach could provide immediate impact in support of mission success by reducing risks, optimizing astronaut performance, and providing valuable insights into long-term astronaut health. Such advancements in clinical decision making are important next steps in building dynamic individual risk profiles for astronauts, increasing crew autonomy and providing tailored countermeasures

Alice R W Tang↗

Calibration and Initial Results of Space Radiation Dosimetry Using the iMESA-R

The integrated Miniaturized Electrostatic Analyzer-Reflight (iMESA-R) is a space weather instrument designed to measure plasma density, temperature, and spacecraft charging, along with total ionizing dose and dose rate. A constellation consisting of five nearly identical instruments has been designed and developed to act as science payloads hosted on-board Department of Defense satellites operating in low-Earth orbit. To validate the dosimetry component of the iMESA-R, a radiation test study was performed to calibrate the dosimeter and ascertain the attenuation due to the instrument aluminum housing. An 80 curie Cobalt-60 radioisotope source emitting beta, X-ray, and gamma ray radiation decay products was used to calibrate the dosimeter response as a function of distance and instrument shielding. We present results of the calibration study along with initial on-orbit data presented from the first operational iMESA-R hosted on-board Space Test Program Satellite 5 in a polar Earth orbit. The initial on-orbit data demonstrate the ability to map the radiation environment, particularly the South Atlantic Anomaly and the auroral regions using total ionizing dose rate due to electrons of E > 1.5 MeV and protons of E > 25 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Understanding the Dissolution and Passivation of an Aluminum Electrode during Electrocoagulation of Groundwater Using Neutron and X-ray Reflectometry

An aluminum (Al)-based electrocoagulation (EC) system can effectively remove dissolved silica and hardness in groundwater. The effectiveness of Al-EC in terms of pollutant removal, Faradaic efficiency, and energy consumption depends on the interfacial electrolysis or passivation of the electrode in water. Thus, understanding the electrolysis reaction at the liquid/electrode interface during operation is important for sustainable EC deployment. Here, a continuous flow-through Al-EC system was tested with various groundwater simulants, i.e., chloride (Cl – )-based, sulfate (SO 4 2– )-based, and mixed solutions. High pollutant removal with low energy consumption was observed in Cl – -based groundwater treatment, while low pollutant removal with high energy consumption was observed in SO 4 2– -based groundwater. For example, the required energy per unit mass of Al dosing in SO 4 2– -based groundwater is three times higher than that in Cl – -based groundwater at 10 mA/cm 2 . However, increasing the Cl – concentration significantly reduces this energy demand. In SO 4 2– -based groundwater, the silicate removal efficiency drops from 85.1% to 24.0% compared to that for Cl – -based groundwater, while Mg 2+ and Ca 2+ removal efficiencies decrease to 0.6% from 15.8% and 5.7% from 44.8%, respectively. To better understand this EC performance, we used in situ neutron reflectometry (NR) to examine the interfacial dynamics of Al dissolution and passivation at a 100 nm scale occurring on the surface of the sacrificial Al electrodes during EC. Ex situ X-ray reflectometry (XRR) was also used to support the in situ NR results. Both NR and XRR results revealed that Al dissolution is influenced by the presence of Cl – in the simulants, while a passivating layer forms on the electrode in a SO 4 2– -based solution. In the Cl – -based solution, anodic Al dissolution occurred locally and inhomogeneously across the surface of the Al anode film, resulting in a localized thickness reduction over time. In the SO 4 2– -based solution, no apparent dissolution of the Al anode was identified. Instead, Al underwent oxidation, forming an amorphous Al 2 O 3 surface layer within the Al electrode film that increased in thickness over time. In the mixed solution, both anodic Al dissolution and surface Al 2 O 3 layer formation occurred, indicating that Al dissolution and surface Al 2 O 3 layer formation are attributable to the Cl – and SO 4 2– ions, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation-induced segregation in dilute Fe–Cr: A rate-theory framework for the Cr enrichment–depletion transition at the grain boundary

Radiation-induced segregation (RIS) poses a significant challenge for ferritic Fe–Cr alloys under irradiation, as it can compromise mechanical integrity and increase susceptibility to intergranular corrosion. Yet, the mechanisms governing Cr segregation remain incompletely understood. Here, in this study, we present a physics-based rate-theory model parameterized using self-consistent mean field theory-based Onsager transport coefficients to investigate RIS at the grain boundary in dilute Fe-(0.1 at. %) Cr. Under equal production rates of vacancies and self-interstitial atoms (SIA), and their equal absorption rates by bulk dislocations, the model simulates the experimentally observed transition from Cr enrichment at low temperatures to depletion at higher temperatures. Under these unbiased conditions, systematic investigation reveals that while temperature-dependent transport properties dictate the segregation direction, dose rate, grain size, and dislocation density only influence the magnitude and spatial extent of Cr segregation. However, under more realistic conditions of preferential vacancy production within damage cascade and/or preferential SIA absorption by bulk dislocations, the enrichment-to-depletion transition shifts to lower temperatures. Our findings demonstrate that RIS predictions based solely on transport coefficients are valid only under symmetric point defect flux conditions, and that biases in defect production and absorption must be considered for accurate predictions. This work provides a mechanistic framework for understanding RIS in ferritic alloys and informs alloy design for advanced nuclear systems.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of Electron Irradiation on Candidate Materials for Target Window in Accelerator-Driven Mo-99 Production

Room-temperature (RT) axial tensile tests were conducted in 2018 and 2021 with flat, sub-sized, dog-boned samples of non-irradiated and irradiated Inconel 718 and irradiated beryllium (Be). The sample gauge length was 7.62 mm. Tensile properties of interest are the engineering yield stress (YS), ultimate tensile stress (UTS), uniform elongation (UE) and total elongation (TE). The electron dose of the 2021 samples was ≈2 times the dose of samples tested in 2018. Relative dose rates of 0, 1 (2018), and 2 (2021) are assigned to these samples. The 2021 electron-irradiated Be samples were brittle with a low failure stress of 338±64 MPa based on two samples. The failures occurred in the gauge section. The 2018 results for electron-irradiated Be indicated a slight decrease in ductility and strength for the one electron-irradiated sample that failed in the gauge section.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

CA Special Studies: Updates to the Groundwater Pathway Radiological Dose

This environmental calculation file (ECF) summarizes the groundwater pathway exposure assumptions and methodologies used to revise radionuclide specific unit dose factors (UDFs) published in CP-64491, Hanford Site Composite Analysis Data Package – Exposure Scenarios and Radionuclide Specific Dose Conversion Factors. Specifically, this ECF describes the updated exposure-related parameters used to calculate radionuclide specific UDFs based on recommendations from the Low-Level Waste Disposal Facility Federal Review Group (LFRG) and updates to Adult External DCFs included in EPA 402-R-93-081, External Exposure to Radionuclides in Air, Water, and Soil hereinafter called Federal Guidance Report [FGR]).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

HZETRN: neutron and proton production in quasi-elastic scattering of GCR heavy-ions

The development of transport models for radiation shielding design and evaluation has provided a series of deterministic computer codes that describe galactic cosmic radiation (GCR), solar particle events, and experimental beams at particle accelerators. These codes continue to be modified to accommodate new theory and improvements to the particle interaction database (Cucinotta et al., 1994, NASA Technical Paper 3472, US Government Printing Office, Washington DC). The solution employed by the heavy-ion transport code HZETRN was derived with the assumption that nuclear fragments are emitted with the same velocity as the incident ion through velocity conserving nuclear interactions. This paper presents a version of the HZETRN transport code that provides a more realistic distribution of the energy of protons and neutrons emitted from GCR interactions in shields. This study shows that the expected GCR dose equivalent is lower than previously calculated for water shields that are less than 110 g cm-2 thick. Calculations of neutron energy spectra in low Earth orbit indicate substantial contributions from relativistic neutrons. c2001 Elsevier Science Ltd. All rights reseved.

NASA Center LaRC↗

Induction of Micronuclei in Human Fibroblasts across the Bragg Curve of Energetic Si and Fe Ions

The space environment consists of a varying field of radiation particles including high-energy ions, with spacecraft shielding material providing the major protection to astronauts from harmful exposure. Unlike low-LET gamma or X-rays, the presence of shielding does not always reduce the radiation risks for energetic charged particle exposure. Since the dose delivered by the charged particle increases sharply as the particle approaches the end of its range, a position known as the Bragg peak, the Bragg curve does not necessarily represent the biological damage along the particle traversal since biological effects are influenced by the track structure of both primary and secondary particles. Therefore, the biological Bragg curve is dependent on the energy and the type of the primary particle, and may vary for different biological endpoints. We studied micronuclei (MN) induction across the Bragg curve of Si and Fe ions at incident energies of 300 MeV/nucleon and 1 GeV/nucleon. A quantitative biological response curve did not reveal an increased yield of MN at the location of the Bragg peak. However, the ratio of mono- to bi-nucleated cells, which indicates inhibition in cell progression, increased at the Bragg peak location. These results confirm the hypothesis that severely damaged cells at the Bragg peak are likely to go through reproduction death.

Wu, H.↗

Bragg Curve, Biological Bragg Curve and Biological Issues in Space Radiation Protection with Shielding

The space environment consists of a varying field of radiation particles including high-energy ions, with spacecraft shielding material providing the major protection to astronauts from harmful exposure. Unlike low-LET gamma or X-rays, the presence of shielding does not always reduce the radiation risks for energetic charged particle exposure. Since the dose delivered by the charged particle increases sharply as the particle approaches the end of its range, a position known as the Bragg peak, the Bragg curve does not necessarily represent the biological damage along the particle traversal since biological effects are influenced by the track structure of both primary and secondary particles. Therefore, the biological Bragg curve is dependent on the energy and the type of the primary particle, and may vary for different biological endpoints. To achieve a Bragg curve distribution, we exposed cells to energetic heavy ions with the beam geometry parallel to a monolayer of fibroblasts. Qualitative analyses of gamma-H2AX fluorescence, a known marker of DSBs, indicated increased clustering of DNA damage before the Bragg peak, enhanced homogenous distribution at the peak, and provided visual evidence of high linear energy transfer (LET) particle traversal of cells beyond the Bragg peak. A quantitative biological response curve generated for micronuclei (MN) induction across the Bragg curve did not reveal an increased yield of MN at the location of the Bragg peak. However, the ratio of mono-to bi-nucleated cells, which indicates inhibition in cell progression, increased at the Bragg peak location. These results, along with other biological concerns, show that space radiation protection with shielding can be a complicated issue.

Honglu, Wu↗

NASA Tech Briefs, August 2011

Topics covered include: Miniature, Variable-Speed Control Moment Gyroscope; NBL Pistol Grip Tool for Underwater Training of Astronauts; HEXPANDO Expanding Head for Fastener-Retention Hexagonal Wrench; Diagonal-Axes Stage for Pointing an Optical Communications Transceiver; Improvements in Speed and Functionality of a 670-GHz Imaging Radar; IONAC-Lite; Large Ka-Band Slot Array for Digital Beam-Forming Applications; Development of a 150-GHz MMIC Module Prototype for Large-Scale CMB Radiation; Coupling Between Waveguide-Fed Slot Arrays; PCB-Based Break-Out Box; Multiple-Beam Detection of Fast Transient Radio Sources; Router Agent Technology for Policy-Based Network Management; Remote Asynchronous Message Service Gateway; Automatic Tie Pointer for In-Situ Pointing Correction; Jitter Correction; MSLICE Sequencing; EOS MLS Level 2 Data Processing Software Version 3; DspaceOgre 3D Graphics Visualization Tool; Metallization for Yb14MnSb11-Based Thermoelectric Materials; Solvent/Non-Solvent Sintering To Make Microsphere Scaffolds; Enhanced Fuel-Optimal Trajectory-Generation Algorithm for Planetary Pinpoint Landing; Self-Cleaning Coatings and Materials for Decontaminating Field-Deployable Land and Water-Based Optical Systems; Separation of Single-Walled Carbon Nanotubes with DEP-FFF; Li Anode Technology for Improved Performance; Post-Fragmentation Whole Genome Amplification-Based Method; Microwave Tissue Soldering for Immediate Wound Closure; Principles, Techniques, and Applications of Tissue Microfluidics; Robotic Scaffolds for Tissue Engineering and Organ Growth; Stress-Driven Selection of Novel Phenotypes; Method for Accurately Calibrating a Spectrometer Using Broadband Light; Catalytic Microtube Rocket Igniter; Stage Cylindrical Immersive Display; Vacuum Camera Cooler; Atomic Oxygen Fluence Monitor; Thermal Management Tools for Propulsion System Trade Studies and Analysis; Introduction to Physical Intelligence; Technique for Solving Electrically Small to Large Structures for Broadband Applications; Accelerated Adaptive MGS Phase Retrieval; Large Eddy Simulation Study for Fluid Disintegration and Mixing; Tropospheric Correction for InSAR Using Interpolated ECMWF Data and GPS Zenith Total Delay; Technique for Calculating Solution Derivatives With Respect to Geometry Parameters in a CFD Code; Acute Radiation Risk and BRYNTRN Organ Dose Projection Graphical User Interface; Probabilistic Path Planning of Montgolfier Balloons in Strong, Uncertain Wind Fields; Flight Simulation of ARES in the Mars Environment; Low-Outgassing Photogrammetry Targets for Use in Outer Space; Planning the FUSE Mission Using the SOVA Algorithm; Monitoring Spacecraft Telemetry Via Optical or RF Link; and Robust Thermal Control of Propulsion Lines for Space Missions.

Source record↗