Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Picosecond Pulsed Laser Ablation for the Surface Preparation of Epoxy Composites

As part of a technical challenge under the Advanced Composites Program, methods for improving pre-bond process control for aerospace composite surface treatments and inspections, in conjunction with Federal Aviation Administration guidelines, are under investigation. The overall goal is to demonstrate high fidelity, rapid and reproducible surface treatment and surface characterization methods to reduce uncertainty associated with the bonding process. The desired outcomes are reliable bonded airframe structure, and reduced timeline to certification. In this work, laser ablation was conducted using a q-switched Nd:YVO4 laser capable of nominal pulse durations of 8 picoseconds (ps). Aerospace structural carbon fiber reinforced composites with an epoxy resin matrix were laser treated, characterized, processed into bonded assemblies and mechanically tested. The characterization of ablated surfaces were conducted using scanning electron microscopy (SEM), water contact angle (WCA) goniometry, micro laser induced breakdown spectroscopy (uLIBS), and electron spin resonance (ESR). The bond performance was assessed using a double cantilever beam (DCB) test with an epoxy adhesive. The surface characteristics and bond performance obtained from picosecond ablated carbon fiber reinforced plastics (CFRPs) are presented herein.

Palmieri, Frank↗

Electron bunch energy and phase feed-forward stabilization system for the Mark V RF-linac free-electron laser

An amplitude and phase compensation system has been developed and tested at the University of Hawai'i for the optimization of the RF drive system to the Mark V free-electron laser. Temporal uniformity of the RF drive is essential to the generation of an electron beam suitable for optimal free-electron laser performance and the operation of an inverse Compton scattering x-ray source. The design of the RF measurement and compensation system is described in detail and the results of RF phase compensation are presented. Performance of the free-electron laser was evaluated by comparing the measured effects of phase compensation with the results of a computer simulation. Finally, preliminary results are presented for the effects of amplitude compensation on the performance of the complete system.

43 PARTICLE ACCELERATORS↗

Nondestructive Evaluation of Foam Insulation on the Space Shuttle External Tank

Foam loss on the External Tank (ET) during launch can be caused by a number of factors. Voids are the best understood mechanism of foam loss, although it is known that delaminations, cracks and crushed foam can also lead to liberation of foam. Shortly after the Columbia accident, work began on non-destructive evaluation of foam targeted at finding voids and delaminations. After several months of searching for candidate methods capable of inspecting ET foam, the five most promising techniques were taken through a blind test and narrowed down to two methods to develop and use for inspection of the ET. These methods were backscatter radiography and terahertz imaging. The backscatter radiography system measures a test part by detecting Compton backscattered x-ray energy generated by a collimated beam of x-rays directed at the test subject. This collimated beam is scanned across the subject, recording scatter intensity data one pixel at a time until the area of interest is covered. The resulting data can be used to generate an image similar to a radiograph. Some depth information can be gathered utilizing apertures or collimation on the detectors. The detectors are located around the collimated source, making this a single sided inspection. The void detection limit with the currently utilized system is around 0.5 inches in diameter by 0.2 inches high. The terahertz imaging system inspects a test part by utilizing a transceiver to emit a pulse focused at the aluminum skin of the ET, which reflects it back to the transceiver where it is analyzed. The transceiver is scanned across the area of interest until a measurement has been taken at every location. Amplitude, time delay and frequency content are examined to note any discontinuities which may be the result of a void or other type of defect. The pulse currently utilized is in the millimeter wave regime. The void detection limit with this system is around 0.5 inches in diameter by 0.2 inches high. With increased interest in other causes of foam loss following the flight of Discovery in July 2005, laser shearography was added to the techniques used for inspecting ET foam. The shearography method records a sheared image of a laser speckle pattern projected on a test part before And after some sort of excitation. The resultant fringe pattern allows the slope of the out of plane displacement to be measured. For crushed and delaminated foam applications, a non-contact air coupled acoustic force is used to excite the surface of the foam. Regions without defects tend to respond differently to the sound energy than do regions with defects, generating a map of the foam integrity. Foam crushed to a depth of about 0.1 inches is detectable with shearography even after it has relaxed to its original shape.

Richter, Joel↗

Time-resolved measurements of the hot-electron population in ignition-scale experiments on the National Ignition Facility (invited)

In laser-driven inertial confinement fusion, hot electrons can preheat the fuel and prevent fusion-pellet compression to ignition conditions. Measuring the hot-electron population is key to designing an optimized ignition platform. The hot electrons in these high-intensity, laser-driven experiments, created via laser-plasma interactions, can be inferred from the bremsstrahlung generated by hot electrons interacting with the target. At the National Ignition Facility (NIF) [G. H. Miller, E. I. Moses, and C. R. Wuest, Opt. Eng. 43, 2841 (2004)], the filter-fluorescer x-ray (FFLEX) diagnostic–a multichannel, hard x-ray spectrometer operating in the 20–500 keV range–has been upgraded to provide fully time-resolved, absolute measurements of the bremsstrahlung spectrum with ∼300 ps resolution. Initial time-resolved data exhibited significant background and low signal-to-noise ratio, leading to a redesign of the FFLEX housing and enhanced shielding around the detector. The FFLEX x-ray sensitivity was characterized with an absolutely calibrated, energy-dispersive high-purity germanium detector using the high-energy x-ray source at NSTec Livermore Operations over a range of K-shell fluorescence energies up to 111 keV (U K{sub β}). The detectors impulse response function was measured in situ on NIF short-pulse (∼90 ps) experiments, and in off-line tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relative lateration across the Los Angeles basin using a satellite laser ranging system

In January of 1981 the Transportable Laser Ranging System (TLRS) developed for NASA by the University of Texas was used to conduct a four-day test of the relative lateration technique. The test evolved making repeated measurements of six lines over the Los Angeles basin varying in distance from 26 to 84 kilometers. Although the raw times-of-flight to the various targets changed typically by 5 parts in 10 to the 6th, their line ratios varied nearly an order of magnitude less. The test suggests that the TLRS or other pulsed laser ranging systems might be able to economically combine Lageos ranging and long baseline horizontal work to survey large areas for accumulating crustal strain.

Silverberg, E. C.↗

Progress in laser-spectroscopic techniques for aerodynamic measurements - An overview

An overview is given of the capabilities and recent progress in laser-spectroscopic measurement techniques for use in aerodynamic test facilities and flight research vehicles. It includes a survey of the literature which is centered on this application of laser spectroscopy. The intended reader is the specialist in experimental fluid dynamics who is not intimately familiar with the physics or applications of laser spectroscopy. Thus, some discussion is also included of the nature of each laser-spectroscopic technique and the practical aspects of its use for aerodynamic measurements. The specific techniques reviewed include laser absorption, laser-induced fluorescence, laser Rayleigh scattering, and laser Raman scattering including spontaneous and coherent processes.

Mckenzie, Robert L.↗

The detonation cylinder test: Determination of full wall velocity and shape from a single velocimetry probe with an arbitrary angle

Laser velocimetry probes are used for measuring wall velocity in cylinder test expansion experiments. Previously, a method was developed to determine the full wall velocity, angle and case shape from a single probe aligned with the initial cylinder wall normal (S.I. Jackson, Proc. Combust. Inst., Vol. 35, 2015, pg.1997-2004). However, probes are often positioned at arbitrary (non-normal) angles to optimize light return from the cylinder surface. This work extends the prior method to accommodate arbitrary probe angles and allows solution of the full cylinder wall motion and shape from a single probe, using only the assumption of steady flow in the shock frame. When used in conjunction with the prior method, it can also be used to approximate the detonation product isentrope analytically from a single velocimetry probe at any angle.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Airborne Instruments for the In Situ Detection of ClONO2, NO2, ClO, and BrO in the Stratosphere

Design and construction of an in situ sensor for the detection of stratospheric ClONO2, ClO, BrO, and NO2, was conceived as a two-year program. The experiment has two novel components: a resistive silicon thermal dissociation heater used to fragment ClONO2 into ClO and NO2 and a laser-induced fluorescence sensor for N02. These two new components are integrated into an experiment that uses technology developed in our labs for the ER-2 ClO and ER-2 HO(X) instruments. During the first year we reconstructed our laboratory prototypes for ClONO2 and NO2 detection and made substantial improvements in the calibration apparatus. Results from these laboratory experiments have been used to refine the design of the flight instrument. During this year we began the design of all of the long-lead items required to produce a flight instrument: including the design and fabrication of the air flow system used to direct stratospheric air to our halogen sensors, design and prototyping of an aircraft-compatible thermal dissociation heater, and development and test of a new high powered laser system. Finally, we have designed and released for fabrication several subsystems.

Anderson, James G.↗

Nonlinear Thomson scattering of a relativistically strong tightly focused ultrashort laser pulse

The problem of nonlinear Thomson scattering of a relativistically strong linearly polarized ultrashort laser pulse tightly focused into a spot with a diameter of D{sub F} ≳ λ (where λ is the laser wavelength) is solved. The energy, spectral, and angular distributions of radiation generated due to Thomson scattering from test electrons located in the focal region are found. The characteristics of scattered radiation are studied as functions of the tightness of laser focusing and the initial position of test particles relative to the center of the focal region for a given laser pulse energy. It is demonstrated that the ultratight focusing is not optimal for obtaining the brightest and hardest source of secondary electromagnetic radiation. The hardest and shortest radiation pulse is generated when the beam waist diameter is ≃10λ.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Corrosion Inhibition of Cold-rolled Low Carbon Steel with Pulse Fiber Laser Ablation in Water

This study aims at the use of a fiber laser for modifying the surface properties of cold-rolled low carbon steel via a pulse laser ablation technique in water. The effect on the corrosion behavior of the fiber laser-treated metal surface was investigated in NaCl and HCl environments. Electrochemical tests showed significant improvement in the corrosion resistance of the laser-treated sample in NaCl, with an increase in open-circuit potential (OCP) from − 0.65 to − 0.60 V and an inhibition efficiency of 89.22% as obtained from the impedance study. Such improvement was less significant in an acidic environment. Lower corrosion rates of 20.9 mpy and 5.819 × 10{sup 3} mpy were obtained for the laser-treated samples in neutral and acidic electrolytes, respectively, than the corrosion rates obtained for the as-received samples (33.2 mpy and 11.98 × 10{sup 3} mpy). Morphological analysis indicated a passive film built by spherical grains of regular size on the metal surface after laser treatment. The corrosion inhibition effects in NaCl were evident by the nonexistence of the common corrosion products of lepidocrocite and crystalline structures that were seen on as-received samples; only polyhedral crystals with micrograins grown on them were seen covering the laser-treated surface. Therefore, the laser treatment using a fiber laser source improved the corrosion resistance of cold-rolled low carbon steel.

36 MATERIALS SCIENCE↗

Defect Characterization Using Positron Annihilation Spectroscopy on Laser-Ablated Surfaces

In recent years, short, pulsed laser ablation has been gaining popularity for machining small-scale test geometries from bulk samples and for efficient serial sectioning. These laser-based techniques are being added to the toolbox in material science, which makes it necessary to understand the changes in the material that occur from the laser–material interaction. Positron annihilation spectroscopy is a unique, nondestructive technique to investigate small defects in materials difficult to investigate by other tools. In this work, Doppler broadening and positron lifetime annihilation spectroscopy are utilized to help quantify the damage in materials treated with short, pulsed lasers. Using a femtosecond laser on single crystal silicon, this manuscript shows that clusters of vacancy-like defects and small voids increase systematically with laser power. Lastly, the damage induced by the laser can also reach to micrometer depths.

36 MATERIALS SCIENCE↗

Laser Angioplasty

The principal method of dealing with coronary artery blockage is bypass surgery. A non-surgical alternative available to some patients is balloon angioplasty. For several years, medical researchers have been exploring another alternative that would help a wider circle of patients than the balloon treatment and entail less risk than bypass surgery. A research group is on the verge of an exciting development: laser angioplasty with a 'cool' type of laser, called an excimer laser, that does not damage blood vessel walls and offers non-surgical cleansing of clogged arteries with extraordinary precision. The system is the Dymer 200+ Excimer Laser Angioplasty System, developed by Advanced Intraventional Systems. Used in human clinical tests since 1987, the system is the first fully integrated 'cool' laser capable of generating the requisite laser energy and delivering the energy to target arteries. Thirteen research hospitals in the U.S. have purchased Dymer 200+ systems and used them in clinical trials in 121 peripheral and 555 coronary artery cases. The success rate in opening blocked coronary arteries is 85 percent, with fewer complications than in balloon angioplasty. Food and Drug Administration approval for the system is hoped for in the latter part of 1990. * Advanced Intraventional Systems became Spectranetics in 1994 and discontinued the product.

Source record↗

Laser Interferometry for Gravitational Wave Observation: LISA and LISA Pathfinder

The Laser Interferometer Space Antenna (LISA) is a planned NASA-ESA gravitational wave observatory in the frequency range of 0.1mHz-100mHz. This observation band is inaccessible to ground-based detectors due to the large ground motions of the Earth. Gravitational wave sources for LISA include galactic binaries, mergers of supermasive black-hole binaries, extreme-mass-ratio inspirals, and possibly from as yet unimagined sources. LISA is a constellation of three spacecraft separated by 5 million km in an equilateral triangle, whose center follows the Earth in a heliocentric orbit with an orbital phase offset oF 20 degrees. Challenging technology is required to ensure pure geodetic trajectories of the six onboard test masses, whose distance fluctuations will be measured by interspacecraft laser interferometers with picometer accuracy. LISA Pathfinder is an ESA-launched technology demonstration mission of key LISA subsystems such us spacecraft control with micro-newton thrusters, test mass drag-free control, and precision laser interferometry between free-flying test masses. Ground testing of flight hardware of the Gravitational Reference Sensor and Optical Metrology subsystems of LISA Pathfinder is currently ongoing. An introduction to laser interferometric gravitational wave detection, ground-based observatories, and a detailed description of the two missions together with an overview of current investigations conducted by the community will bc discussed. The current status in development and implementation of LISA Pathfinder pre-flight systems and latest results of the ongoing ground testing efforts will also be presented

Guzman, Felipe↗

Optimization of Diode Laser System to Treat Benign Prostate Hyperplasia Final Report CRADA No. TSB-1154-95

Benign prostate hyperplasia (BPH) is a pervasive condition of enlargement of the male prostate gland which leads to several urinary difficulties ranging from hesitancy to incontinence to kidney dysfunction in severe cases. Currently the most common therapy is transurethral resection of the prostate (TURP) utilizing an electrosurgical device. Although TURP is largely successful, new BPH therapy methods are desired to reduce the cost and recovery time, improve the success rate, and reduce side effects. Recently, lasers have been introduced for this purpose. Indigo Medical Inc. is currently engaged in the development, testing, and preparation for sales of a new diode laser based BPH therapy system. The development is based on laboratory experiments, animal studies, and a limited FDA-approved clinical trial in the US and in other countries. The addition of sophisticated numerical modeling, of the sort that has been highly developed at Lawrence Livermore National Laboratory, can greatly aid in the design of the system and treatment protocol. The benefits to DOE include the maintenance and advancement of numerical modeling expertise in radiation-matter interactions of the sort essential for the stockpile stewardship, inertial confinement fusion, and advanced manufacturing, and the push on advanced scientific computational methods, ultimately in areas such as 3-D transport.

42 ENGINEERING↗

The role of SLR and LLR in relativity

While General Relativity has been adopted as the standard theory of relativity, there are alternative theories, with important implications for gravitational physics, which can only be discounted with tests of sufficient accuracy. In addition to its contributions to lunar and solar system dynamics, Lunar Laser Ranging, in combination with other solar system data continues to refine some important limits. Satellite laser ranging tracking of geodetic satellites can provide similar tests, but the accuracy is usually limited by gravitational and nongravitational perturbations.

Ries, John C.↗

9.3 Microns: Toward a Next-Generation CO2 Laser for Particle Accelerators

We present realistic theoretical predictions of the performance of the next-generation long-wave infrared (LWIR) laser for advanced particle acceleration research at the Accelerator Test Facility (ATF) of Brookhaven National Laboratory. Two upgrades are planned for the present ATF CO2 laser, which currently produces up to 5 TW peak power in 2 ps pulses at 9.2 μm. For the first upgrade, the deployment of a ten-millijoule solid-state seed laser at 9.3 μm will reduce the pulse duration 4 times, to 500 fs, and increase the peak power to 15 TW. The second upgrade will be the implementation of the postcompression of this pulse. This will reduce the pulse duration to three optical cycles (100 fs) and increase the usable peak power to 25 TW.

43 PARTICLE ACCELERATORS↗

Vibration characteristics of a laser heterodyne spectrometer tunable diode laser system using a mechanical cooler platform

The Langley Research Center redesigned the cooler test bed hardware for the refrigerator for the purpose of isolating the tunable diode laser (TDL) from the cold tip in a laser heterodyne spectrometer system. Deflection in the lateral and vertical directions were managed on the cold tip and on the TDL. Measurements were analyzed over the frequency range of 0.100 Hz. The results show that the TDL responds approximately one order of magnitude less than that of the cold tip. The redesign of the system provided for adequately isolating the TDL for future operation.

Catherines, J. J.↗

Oxygen ingress study of 3D printed gaseous radiation detector enclosures

As part of our ongoing studies into the potential application of 3D printing techniques to gaseous radiation detectors, we have studied the ability of 3D printed enclosures to resist environmental oxygen ingress. A set of cuboid and hexagonal prism shaped enclosures with wall thicknesses of 4 mm, 6 mm, 8 mm and 10 mm were designed and printed in nylon using a EOSINT P 730 Selective Laser Sintering 3D printer system These test enclosures provide a comparison of different environmental gas ingress for different 3D printing techniques. The rate of change of oxygen concentration was found to be linear, decreasing as the wall thickness increases. It was also found that the hexagonal prism geometry produced a lower rate of change of oxygen concentration compared with the cuboid shaped enclosures. Possible reasons as to why these results were obtained are discussed The implications for the this study for deployable systems are also discussed (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗