Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “kW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Exciter switch

A new exciter switch assembly has been installed at the three DSN 64-m deep space stations. This assembly provides for switching Block III and Block IV exciters to either the high-power or 20-kW transmitters in either dual-carrier or single-carrier mode. In the dual-carrier mode, it provides for balancing the two drive signals from a single control panel located in the transmitter local control and remote control consoles. In addition to the improved switching capabilities, extensive monitoring of both the exciter switch assembly and Transmitter Subsystem is provided by the exciter switch monitor and display assemblies.

Mcpeak, W. L.↗

DSN research and technology support

The activities at the Venus Station (DSS 13) and the Microwave Test Facility, both operated by the Development Support Group, during the 6-month period ending October 15, 1975, were discussed and progress noted. Successful remote operation of the Venus Station from Pasadena during a pulsar observing track was described, along with significant tracking of the planet Venus in an interferometric planetary radar mode. Completion of the first phase of the demonstration of long-distance (1.6-km) transmission of microwave power was reported, with an RF-to-dc conversion efficiency of better than 80% and 30 kW of dc recovered. Routine transmission of clock synchronization signals to the overseas complexes with 64-m antenna stations was also discussed, and extensive analysis of a reported problem with the DSS 14 HV dc power supply which resulted in excessive ripple voltage interfering with transmitter operation was described.

E. B. Jackson↗

Microwave power transmission system studies. Volume 4: Sections 9 through 14 with appendices

The microwave rectifier technology, approaches to the receiving antenna, topology of rectenna circuits, assembly and construction, ROM cost estimates are discussed. Analyses and cost estimates for the equipment required to transmit the ground power to an external user. Noise and harmonic considerations are presented for both the amplitron and klystron and interference limits are identified and evaluated. The risk assessment discussion is discussed wherein technology risks are rated and ranked with regard to their importance in impacting the microwave power transmission system. The system analyses and evaluation are included of parametric studies of system relationships pertaining to geometry, materials, specific cost, specific weight, efficiency, converter packing, frequency selection, power distribution, power density, power output magnitude, power source, transportation and assembly. Capital costs per kW and energy costs as a function of rate of return, power source and transportation costs as well as build cycle time are presented. The critical technology and ground test program are discussed along with ROM costs and schedule. The orbital test program with associated critical technology and ground based program based on full implementation of the defined objectives is discussed.

Maynard, O. E.↗

Hot ion plasma production in HIP-1 using water-cooled hollow cathodes

A steady-state ExB plasma was formed by applying a strong radially inward dc electric field near the mirror throats. Most of the results were for hydrogen, but deuterium and helium plasmas were also studied. Three water-cooled hollow cathodes were operated in the hot-ion plasma mode with the following results: (1) thermally emitting cathodes were not required to achieve the hot-ion mode; (2) steady-state operation (several minutes) was attained; (3) input powers greater than 40 kW were achieved; (4) cathode outside diameters were increased from 1.2 cm (uncooled) to 4.4 cm (water-cooled); (5) steady-state hydrogen plasma with ion temperatures from 185 to 770 eV and electron temperatures from 5 to 21 eV were produced. Scaling relations were empirically obtained for discharge current, ion temperature, electron temperature, and relative ion density as a function of hydrogen gas feed rate, magnetic field, and cathode voltage. Neutrons were produced from deuterium plasma, but it was not established whether thay came from the plasma volume or from the electrode surfaces.

Reinmann, J. J.↗

Solid state remote power controllers for 120 Vdc power systems

Solid state Remote Power Controllers (RPCs) developed for use in any dc power system with voltage up to 120 Vdc and distributed power up to 3.6 kW per bus are described. The RPCs were demonstrated to be reliable, 99 percent efficient, comparatively simple, and potentially low in cost. Advantages of the RPCs include: contactless switching; controlled rates of current rise and fall; current limiting; and fast, well-defined, repeatable response to overloads and faults.

Sundberg, G. R.↗

Mechanical capacitor

A new energy storage system (the mechanical capacitor), using a spokeless magnetically levitated composite ring rotor, is described and design formulas for sizing the components are presented. This new system is configured around a permanent magnet (flux biased) suspension which has active servo control in the radial direction and passive control in the axial direction. The storage ring is used as a moving rotor and electronic commutation of the stationary armature coils is proposed. There is no mechanical contact with the rotating spokeless ring; therefore, long life and near zero rundown losses are projected. A 7-kW h system is sized to demonstrate feasibility. A literature review of flywheel energy storage systems is also presented and general formulas are developed for comparing rotor geometries.

Kirk, J. A.↗

Characteristics of the NASA Lewis bumpy-torus plasma generated with positive applied potentials

Experimental observations were made during steady-state operation of a bumpy-torus plasma at input powers up to 150 kW in deuterium and helium gas and with positive potentials applied to the midplane electrodes. In this steady-state ion heating method a modified Penning discharge is operated such that the plasma is acted upon by a combination of strong electric and magnetic fields. Experimental investigation of a deuterium plasma revealed electron temperatures from 14 to 140 eV and ion kinetic temperatures from 160 to 1785 eV. At least two distinct modes of operation exist. Experimental data shows that the average ion residence time in the plasma is virtually independent of the magnetic field strength. Data was taken when all 12 anode rings were at high voltage, and in other symmetric configurations in which the toroidal plasma was generated by applying positive potentials to six anode rings, three anode rings, and a single anode ring.

Roth, J. R.↗

Development of a solar powered residential air conditioner (General optimization)

A commercially available 3-ton residential Lithium Bromide (LiBr) absorption air conditioner was modified for use with lower temperature solar heated water. The modification included removal of components such as the generator, concentration control chamber, liquid trap, and separator; and the addition of a Chrysler designed generator, an off-the-shelf LiBr-solution pump. The design goal of the modified unit was to operate with water as the heat-transfer fluid at a target temperature of 85 C (185 F), 29.4 C (85 F) cooling water inlet, producing 10.5 kW (3 tons) of cooling. Tests were performed on the system before and after modification to provide comparative data. At elevated temperatures (96 C, 205 F), the test results show that Lithium Bromide was carried into the condenser due to the extremely violent boiling and degraded the evaporator performance.

Lowen, D. J.↗

DSN research and technology support

Continuing testing and refinement of the remote controlled, unattended automated pulsar observing station is noted, along with routine pulsar observations of 22 pulsars. Radar observations of geostationary satellite are discussed. Current status of the 400-kW X-band radar is reported along with routine automatic testing of the stability-reliability of the DSS 13 maser-receiver noise adding radiometer combination. A failure in the Faraday rotation receiving system is noted along with discussion in some detail of the activities of the high power transmitter maintenance facility. Continuation of receiver phase stability testing, specifically the effects of temperature on coaxial cables, is discussed and results reported. A demonstration at full power of the microwave power transmission facility is noted and routine support of the planetary radio astronomy experiment is discussed. Transmission of master clock synchronization signals to overseas DSN stations is also reported.

Jackson, E. B.↗

The NASA high power carbon dioxide laser: A versatile tool for laser applications

A closed-cycle, continuous wave, carbon dioxide high power laser has been designed and fabricated to support research for the identification and evaluation of possible high power laser applications. The device is designed to generate up to 70 kW of laser power in annular shape beams from 1 to 9 cm in diameter. Electric discharge, either self sustained or electron beam sustained, is used for excitation. This laser facility provides a versatile tool on which research can be performed to advance the state-of-the-art technology of high power CO2 lasers in such areas as electric excitation, laser chemistry, and quality of output beams. The facility provides a well defined, continuous wave beam for various application experiments, such as propulsion, power conversion, and materials processing.

Lancashire, R. B.↗

Laboratory-scale uranium RF plasma confinement experiments

An experimental investigation was conducted using 80 kW and 1.2 MW RF induction heater facilities to aid in developing the technology necessary for designing a self-critical fissioning uranium plasma core reactor. Pure uranium hexafluoride (UF6) was injected into argon-confined, steady-state, RF-heated plasmas in different uranium plasma confinement tests to investigate the characteristics of plamas core nuclear reactors. The objectives were: (1) to confine as high a density of uranium vapor as possible within the plasma while simultaneously minimizing the uranium compound wall deposition; (2) to develop and test materials and handling techniques suitable for use with high-temperature, high-pressure gaseous UF6; and (3) to develop complementary diagnostic instrumentation and measurement techniques to characterize the uranium plasma and residue deposited on the test chamber components. In all tests, the plasma was a fluid-mechanically-confined vortex-type contained within a fused-silica cylindrical test chamber. The test chamber peripheral wall was 5.7 cm ID by 10 cm long.

Roman, W. C.↗

Tower and rotor blade vibration test results for a 100-kilowatt wind turbine

The predominant natural frequencies and mode shapes for the tower and the rotor blades of the ERDA-NASA 100-kW wind turbine were determined. The tests on the tower and the blades were conducted both before and after the rotor blades and the rotating machinery were installed on top of the tower. The tower and each blade were instrumented with an accelerometer and impacted by an instrumented mass. The tower and blade structure was analyzed by means of NASTRAN, and computed values agree with the test data.

Linscott, B. S.↗

Hot ion plasma production in HIP-1 using water-cooled hollow cathodes

The paper reports on hot-ion plasma experiments conducted in a magnetic mirror facility. A steady-state E x B plasma was formed by applying a strong radially inward dc electric field near the mirror throats. Most of the results were for hydrogen, but deuterium and helium plasmas were also studied. Three water-cooled hollow cathodes were operated in the hot-ion plasma mode with the following results: (1) thermally emitting cathodes were not required to achieve the hot-ion mode; (2) steady-state operation (several minutes) was attained; (3) input powers greater than 40 kW were achieved; (4) cathode outside diameters were increased from 1.2 cm (uncooled) to 4.4 cm (water-cooled); (5) steady-state hydrogen plasmas with ion temperatures from 185 to 770 eV and electron temperatures from 5 to 21 eV were produced. Scaling relations were empirically obtained for discharge current, ion temperature, electron temperature, and relative ion density as a function of hydrogen gas feed rate, magnetic field, and cathode voltage.

Reinmann, J. J.↗

Photovoltaic Test and Demonstration Project

The Photovoltaic Test and Demonstration Project was initiated by NASA in June, 1975, to develop economically feasible photovoltaic power systems suitable for a variety of terrestrial applications. Objectives include the determination of operating characteristic and lifetimes of a variety of solar cell systems and components and development of methodology and techniques for accurate measurements of solar cell and array performance and diagnostic measurements for solar power systems. Initial work will be concerned with residential applications, with testing of the first prototype system scheduled for June, 1976. An outdoor 10 kW array for testing solar power systems is under construction.

Forestieri, A. F.↗

Evaluation of the flat-plate solar collector system for electric power generation

This evaluation of the flat-plate collector system was designed to determine the number of flat-plate collectors required to generate a given amount of electricity with optimum efficiency. Variable parameters are the temperature of the heat-transport fluid, both to and from the collector field. In the analysis, the efficiency of the flat-plate collectors was coupled to the efficiency of the thermal cycle to calculate optimal overall system efficiencies. Overall system efficiencies for the system are on the order of 3.5 per cent or less. Over two million 4 ft-by-4 ft collectors would be required to produce 100,000 kW(e). Based on the results, it can be shown that the limiting factor in the use of the flat-plate collector system for electric power generation is the efficiency of the collectors. An increase in the overall system efficiency can occur only if the collector efficiency can be increased at higher surface temperatures.

Athey, R. E.↗

Characteristics of the NASA Lewis Bumpy Torus plasma generated with positive applied potentials

Experimental observations have been made during steady-state operation of the NASA Lewis Bumpy Torus experiment at input powers up to 150 kW in deuterium and helium gas, and with positive potentials applied to the midplane electrodes. This steady-state ion heating method utilizes a modified Penning discharge operated in a bumpy torus confinement geometry such that the plasma is acted upon by a combination of strong electric and magnetic fields. Experimental investigation of a deuterium plasma revealed electron temperatures from 14 to 140 eV and ion kinetic temperatures from 160 to 1785 eV. At least two distinct modes of operation exist, each of which is associated with a characteristic range of background pressure and electron temperature. Experimental data show that the average ion residence time in the plasma is virtually independent of the magnetic field strength.

Roth, J. R.↗

Microwave power tubes for space applications

Feasibility evaluations of klystron amplifiers for conversion of solar power in synchronous orbit into microwave power at 2.4 GHz and transmission to earth were carried out. It was found that amplitrons and klystrons, using a depressed collector augmentation, can achieve efficiencies in excess of 80% if the power output is kept higher than 50 kW. Body wound selenoid provides the needed beam-focusing field. Narrow bandwidth requirements permit a low cathode loading density of 0.5 A/sq cm produced at approximately 850 centigrades. Emission tests indicate a potential life expectancy of 20 to 40 years.

Kosmahl, H.↗

Laser-heated rocket studies

CW laser heated rocket propulsion was investigated in both the flowing core and stationary core configurations. The laser radiation considered was 10.6 micrometers, and the working gas was unseeded hydrogen. The areas investigated included initiation of a hydrogen plasma capable of absorbing laser radiation, the radiation emission properties of hot, ionized hydrogen, the flow of hot hydrogen while absorbing and radiating, the heat losses from the gas and the rocket performance. The stationary core configuration was investigated qualitatively and semi-quantitatively. It was found that the flowing core rockets can have specific impulses between 1,500 and 3,300 sec. They are small devices, whose heating zone is only a millimeter to a few centimeters long, and millimeters to centimeters in radius, for laser power levels varying from 10 to 5,000 kW, and pressure levels of 3 to 10 atm. Heat protection of the walls is a vital necessity, though the fraction of laser power lost to the walls can be as low as 10% for larger powers, making the rockets thermally efficient.

Kemp, N. H.↗