Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “integrated controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Fleet Algorithm Design for Pooled Rideshare: Integrating Human Factors, Simulation, and Optimization

This dissertation explores the study the integration of human factors modeling and rideshare fleet control algorithms. Pooled rideshare is a unique transportation mode offering that allows riders increased flexibility and accessibility over public transportation, and decreased cost relative to personal vehicles or traditional rideshare. Additionally, relative to personal vehicles, pooled rideshare offers reduced costs and options for those with difficulty obtaining transportation. Prior research in the space typically focused on modeling human behavior, or optimizing system performance, but a lack of integration of the concepts leads to unrealistic or underutilized outcomes. To tackle this problem, novel rideshare assignment, and repositioning strategies were designed and implemented in a simulation environment. Through a series of successive studies, improvements to current rideshare processes were identified, and beneficial outcomes for profitability, accessibility, and traffic were explored. Further, improved metrics to assess rideshare performance were designed and analyzed in the context of improved rideshare offerings. This research contributes to the field of transportation by tackling novel but pragmatic approaches to challenges facing the rideshare industry. Through the course of this dissertation, rideshares impacts on users, operators, and even regulators will be explored in detail. The justification behind the use of a simulation environment, a set of simulated regional models for testing, and the focus on realism and deployability is illustrated. The research identifies holes in potential markets for the use of both private, and public rideshare systems.

Paul, Joseph↗

Cold Trap Replacement Project Report

This report documents the replacement of the Mechanisms Engineering Test Loop (METL) cold trap. The work involved preparation of the facility to replace the cold trap, removal of the existing welded cold trap from the sodium purification circuit, installation of a new replacement cold trap, completion of associated welds and examinations, restoration of instrumentation and heaters, and controlled return of the cold trap circuit to service. The replacement represented a significant maintenance evolution because the cold trap is an integral welded component of the sodium system. As a result, the work required coordinated control of sodium chemistry, deliberate formation of freeze plugs, inert gas management, precision cutting and welding, and a staged reheating and refill sequence. The activity was executed using procedural controls intended to protect personnel, preserve system cleanliness, and maintain the integrity of the sodium boundary throughout the work. This report provides a narrative summary of the milestone, including the purpose of the work, the pre-job system condition, the major field activities performed, observations made during execution, and the resulting post-work condition of the METL cold trap circuit.

42 ENGINEERING↗

A Plug-and-Play Design Suite of Converters for the Electric Grid

Power electronic (PE) systems are increasingly being integrated into the electric grid in a distributed fashion. As the number of installations increases, the challenge of integration of these systems into the grid is also growing. Advanced control features of these systems are often overlooked or neglected due to the complex nature and novelty of these systems. This is also complicated from the vendor point of view as different converter topology integration is usually composed of single system designs with tight coupling and configurations. The presented work discusses a novel architecture for the integration of PE systems with other sources and loads to create a coordinated controllable resource for the grid. The presented work also describes a system level controller to coordinate these systems. 1 Testing results on a hardware in the loop (HIL) platform are provided to show the validity of the proposed architecture and framework.

Starke, Michael↗

1.2.4.404 - Data-Driven Approach for Hydropower Plant Controller Prototyping Using Remote Hardware in the Loop (DR-HIL)

Real-time prototyping of hydropower plant controls is important for reducing the cost and the risk of field deployment. This project will 1) collect design and operational data from actual hydro plants and 2) use a physics-informed machine learning approach for real-time emulation of hydropower plants, including hydro turbine and hydrodynamics. The data-driven models will be interfaced with digital real-time simulation at NREL’s Flatirons campus for hardware-in-the-loop (HIL) testing of the governor hardware device or controller-HIL (CHIL). The proposed approach will also establish the connectivity based remote CHIL testing capability using real-time data streams from an actual hydro plant. This integrated hydro-plant emulation with CHIL will be used to prototype hydro-governor controls and eventually provide an opportunity to test hydropower integrated with various technologies (e.g. conventional and renewable generation, energy conversion, etc.) as HIL.

controls prototyping↗

Support for Reactor Operators in Case of Cyber-Security Threats (NEUP Final Report)

Increasing use of digital technology in nuclear power plants (NPPs) poses cyber-security as a crucial threat to public safety and to continuous energy production. Cyber-security risks are comprised of complex known and unknown interactions between various entities, system vulnerabilities, network protocols, human users and malicious attacks. There is little understanding or research geared towards plant operators’ response under cyber-security threats and operational procedures to cope with such threats. This is particularly critical when a cyber-security event masquerades as a safety incident or an evolving accident. Instead of leading operators to the remediation of the accident, the masked cyber event may lead them to circumvent the safety mechanisms of the plant. Given these challenges, the objective of this project is to develop a tool to characterize abnormal NPP events as “cyber” or “safety” incidents, and to further develop this tool as a real-time operator aid to assist in response to the incident. This NEUP Final Report summarizes the research efforts towards the above goals and the results in the following three aspects. First, a methodology for classifying abnormal NPP events as cyber-attacks or safety incidents was developed. This provides the basis for responding to potential cyber-attacks. In this methodology, the causal relationships between various variables (i.e., physical variables, network variables, and control variables) for a nuclear system under consideration are modeled using dynamic Bayesian networks. Based on observations of certain variables (i.e., the evidence), inference is performed to identify the state of hidden variables, which helps indicate the occurrence of cyber-attacks or safety incidents. The proposed methodology was applied to the full scope NPP simulator system at The Ohio State University as a case study. The result shows that the proposed methodology is capable of distinguishing between cyber-attacks and safety incidents. Second, a game-theoretic approach for responding to cyber-attacks on nuclear power plants was developed. This is the second major goal of the project, and the method is used to recommend optimal responses to reactor operators in the case of cyber-attacks. We consider two cases in this research. In the first case, the interaction between the defender (i.e., the reactor operator) and the attacker is modeled as a two-player, nonzero-sum, Markov game with an infinite time horizon. In the second case, we consider a semi-Markov game between the defender and the attacker within a finite time horizon. The model in the second case enables us to consider the time sensitive response of the defender. In each case, the method for deriving the Nash equilibrium is developed. The Nash Equilibrium of the game provides the valid prediction of both players’ actions because no single player can benefit from unilaterally deviating from the equilibrium policy if the other player adheres to his/hers, hence it provides the best response of the defender to cyber-attacks. The proposed method in each case is demonstrated through a simplified benchmark digital feedwater control system. Third, a prototype display is developed to integrate the above information. The prototype display depicts the communication information to the operator and incorporates the cyber-security tool developed by the team into the interface. It consists of the regular display in current control rooms, as well as a panel used to indicate the occurrence of cyber-attacks or safety events and a panel used to guide the operator’s response to detected cyber-attacks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Network Security Challenges and Countermeasures for Software-Defined Smart Grids: A Survey

The rise of grid modernization has been prompted by the escalating demand for power, the deteriorating state of infrastructure, and the growing concern regarding the reliability of electric utilities. The smart grid encompasses recent advancements in electronics, technology, telecommunications, and computer capabilities. Smart grid telecommunication frameworks provide bidirectional communication to facilitate grid operations. Software-defined networking (SDN) is a proposed approach for monitoring and regulating telecommunication networks, which allows for enhanced visibility, control, and security in smart grid systems. Nevertheless, the integration of telecommunications infrastructure exposes smart grid networks to potential cyberattacks. Unauthorized individuals may exploit unauthorized access to intercept communications, introduce fabricated data into system measurements, overwhelm communication channels with false data packets, or attack centralized controllers to disable network control. An ongoing, thorough examination of cyber attacks and protection strategies for smart grid networks is essential due to the ever-changing nature of these threats. Previous surveys on smart grid security lack modern methodologies and, to the best of our knowledge, most, if not all, focus on only one sort of attack or protection. This survey examines the most recent security techniques, simultaneous multi-pronged cyber attacks, and defense utilities in order to address the challenges of future SDN smart grid research. The objective is to identify future research requirements, describe the existing security challenges, and highlight emerging threats and their potential impact on the deployment of software-defined smart grid (SD-SG).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Harnessing Virtual Power Plants Reliably: Enabling tools for increased observability, controllability, operation, and aggregation of distributed energy resources

Harnessing virtual power plants enhances the integration of distributed energy resources into utility grids for a sustainable energy future. Virtual power plants (VPPs) aggregate DERs to enhance resource adequacy and reduce emissions. U.S. utilities are exploring various technologies to manage DERs effectively. FERC Order 2222 allows DERs to participate in both wholesale and retail markets. Enhancing observability and controllability of behind-the-meter (BTM) DERs is essential for reliable grid operations. A hierarchical control architecture can improve coordination among residential energy resources. Field tests showed nearly 20% energy savings and 30% peak power reduction during grid events. Effective management of DERs requires enhanced situational awareness to prevent grid congestion. Integrating DER management systems (DERMS) with existing planning tools can improve operational security. Near-real-time grid models can validate optimal resource set points against resource uncertainty. Traditional uninterruptible power supplies (UPS) can be upgraded to support grid services and become part of VPPs. Upgrading UPS systems can reduce costs by 75% and unlock significant battery capacity. New battery management systems and grid-aware controllers are essential for optimizing UPS performance. Continued research and development are necessary to address challenges in integrating DERs into utility grids. Encouraging customer participation in pilot programs is vital for the evolution of VPPs. Here, the shift towards price-responsive DERs and VPPs is expected to enhance energy distribution efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modified Andronov-Hopf Oscillator-Based Grid-Forming Converter with Emulated Virtual Cable for Enhanced Power Sharing Performance

Nonlinear oscillator-based grid-forming converters offer superior dynamic and steady-state performance, making them an attractive solution for interconnecting renewable resources. This paper proposes a novel modified Andronov-Hopf oscillator to enhance the operating spectrum and facilitate the integration of renewable energy sources. An inner loop controller based on the Lyapunov energy function is implemented to achieve robust stability and performance, while a virtual cable emulation strategy enables seamless parallel operation. Comprehensive modeling and simulation studies validate the effectiveness of the proposed system, demonstrating its capabilities in addressing diverse operating scenarios, including grid faults, renewable energy fluctuations, and parallel operation. The proposed solution exhibits fast transient response, robust stability, and flexible operation, making it a valuable contribution to the field of renewable energy integration. The results of this study can be used to inform the design and implementation of next-generation grid-forming converters, enabling a more sustainable and reliable energy future. Additionally, the proposed system's ability to operate in both grid-connected and islanded modes makes it an ideal candidate for remote and off-grid renewable energy applications. The proposed solution's scalability and modularity also make it suitable for large-scale renewable energy integration. The proposed system is verified through MATLAB/Simulink and PLECS simulations, demonstrating its effectiveness in ensuring robust and efficient operation.

Andronov-Hopf Oscillator (AHO)↗

Three-dimensional electronic scaffolds for monitoring and regulation of multifunctional hybrid tissues

Recently, the integration of electronic elements with cellular scaffolds has brought forth the ability to monitor and control tissue function actively by using flexible free-standing two-dimensional (2D) systems. Capabilities for electrically probing complex, physicochemical and biological three-dimensional (3D) microenvironments demand, however, 3D electronic scaffolds with well-controlled geometries and functional-component distributions. This work presents the development of flexible 3D electronic scaffolds with precisely defined dimensions and microelectrode configurations formed using a process that relies on geometric transformation of 2D precursors by compressive buckling. It demonstrates a capability to fabricate these constructs in diverse 3D architectures and/or electrode distributions aimed at achieving an enhanced level of control and regulation of tissue function relatively to that of other approaches. In addition, this work presents the integration of these 3D electronic scaffolds within engineered 3D cardiac tissues, for monitoring of tissue function, controlling tissue contraction through electrical stimulation, and initiating on-demand, local release of drugs, each through well-defined volumetric spaces. These ideas provide opportunities in fields ranging from in vitro drug development to in vivo tissue repair and many others.

3D electronic scaffolds↗

Autonomous Inverter Controls for Resilient and Secure Grid Operation: Vector Control Design for Grid Forming

The project addresses both fundamental and practical challenges of GFM/GFL inverter control for the power grids with high inverter based resources (IBRs) penetration. A data- driven modeling technique is applied to accurately model dynamics of PWM inverters, including electromagnetic-transient (EMT). Systematic and integrative designs of grid- forming (GFM) and grid-following (GFL) primary controls are developed to guarantee system performance under either normal or abnormal operating conditions without violating constraints. This modeling and control framework provides black-start capability in case of an outage without relying on rotating generators, and its secondary control is also shown to enhance resilience against cyber-physical attacks.

14 SOLAR ENERGY↗

Hardware-Based Randomized Encoding for Sensor Authentication in Power Grid SCADA Systems

Supervisory Control and Data Acquisition (SCADA) systems are utilized extensively in critical power grid infrastructures. Modern SCADA systems have been proven to be susceptible to cyber-security attacks and require improved security primitives in order to prevent unwanted influence from an adversarial party. One section of weakness in the SCADA system is the integrity of field level sensors providing essential data for control decisions at a master station. In this paper we propose a lightweight hardware scheme providing inferred authentication for SCADA sensors by combining an analog to digital converter and a permutation generator as a single integrated circuit. Through this method we encode critical sensor data at the time of sensing, so that unencoded data is never stored in memory, increasing the difficulty of software attacks. We show through experimentation how our design stops both software and hardware false data injection attacks occurring at the field level of SCADA systems.

42 ENGINEERING↗

A data-driven network optimisation approach to coordinated control of distributed photovoltaic systems and smart buildings in distribution systems

The increasing integration of distributed energy resources, including demand-side resources and distributed photovoltaics (PVs), into distribution systems has resulted in more complicated power system operation. A data-driven network optimisation approach is proposed to coordinate the control of distributed PVs and smart buildings in distribution networks considering the uncertainties of solar power, outdoor temperature and heat gain associated with building thermal dynamics. These uncertain parameters have a significant impact on the operation and control of distributed PVs and smart buildings, bringing challenges to the distribution system operation. In the proposed data-driven distributionally robust optimisation (DRO) approach, the Wasserstein ball is used to construct an ambiguity set for the uncertain parameters, which does not require the probability distributions to be known. Furthermore, a conditional value-at-risk is incorporated into the Wasserstein-based DRO model and converted into a computationally tractable mixed-integer convex optimisation problem. Benchmarked with robust optimisation and chance-constrained programming, the proposed data-driven model can give a less conservative robust solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Observation of solid-state bidirectional thermal conductivity switching in antiferroelectric lead zirconate (PbZrO 3 )

Materials with tunable thermal properties enable on-demand control of temperature and heat flow, which is an integral component in the development of solid-state refrigeration, energy scavenging, and thermal circuits. Although gap-based and liquid-based thermal switches that work on the basis of mechanical movements have been an effective approach to control the flow of heat in the devices, their complex mechanisms impose considerable costs in latency, expense, and power consumption. As a consequence, materials that have multiple solid-state phases with distinct thermal properties are appealing for thermal management due to their simplicity, fast switching, and compactness. Thus, an ideal thermal switch should operate near or above room temperature, have a simple trigger mechanism, and offer a quick and large on/off switching ratio. In this study, we experimentally demonstrate that manipulating phonon scattering rates can switch the thermal conductivity of antiferroelectric PbZrO 3 bidirectionally by –10% and +25% upon applying electrical and thermal excitation, respectively. Our approach takes advantage of two separate phase transformations in PbZrO 3 that alter the phonon scattering rate in different manners. In this study, we demonstrate that PbZrO 3 can serve as a fast (<1 second), repeatable, simple trigger, and reliable thermal switch with a net switching ratio of nearly 38% from ~1.20 to ~1.65 W m –1 K –1 .

25 ENERGY STORAGE↗

Feed-Forward Compensation for Model Predictive Control in Tri-port Current-Source Medium-Voltage String Inverters for PV-Plus-Storage Farms

The novel tri-port current-source medium-voltage string inverter (TCS-MVSI) is a promising candidate for large-scale PV-plus-storage (PVS) farms owing to its galvanic isolation, easy storage integration, soft-switching capability across entire load range, controlled low dv/dt and EMI, benign fault tolerance, etc. Due to its low inertia feature, traditional PI-based control cannot manage large transients effectively. Instead, a model-based predictive control (MPC) is proposed to achieve robust and stable operation. As is well known, the control performance of MPC is compromised by the sampling and computational delay during implementation significantly, if not well addressed. This paper analyzed and quantified these delays and then proposes feed-forward compensation (FFC) for the MPC method to compensate the delays and the large parameter variations due to the low-inertia nature. In addition, this method also compensates for the high dc-link ripple within each switching cycle, a unique issue for low-inertia converters. Here, the proposed method requires low computational effort, allowing it to be extended for multiple ports. The effectiveness of the proposed method has been validated in experiments. In 10 kW test, the proposed method decreases the average dc-link current by 17%, leading to ~20% conduction losses and ~0.5% increase in converter efficiency. In addition, the peak dc-link current also decreases by 15%, resulting in reduced transformer size. As a result, an increased power density can be achieved with the proposed method. Similar improvements have been observed across the power range from 2 kW to 10 kW.

30 DIRECT ENERGY CONVERSION↗

DSP Implementation of a Novel Recurrent Neural Network Controller into a TI Solar Microinverter

Single-phase grid-tied inverters are widely used to integrate small-scale renewable energy sources and distributed generations to the utility grid. A novel Recurrent Neural Network (RNN) current controller is introduced to solve the resonant problem associated with LCL based inverters. The well-trained RNN controller was validated through a Texas Instruments (TI) LCL filter based solar microinverter kit that contains a C2000 TI microcontroller. The inverter closed current loop test without the grid connection was conducted in a laboratory setup to verify the RNN contoller functionality. The laboratory waveform results verified that the RNN current controller produced the strong tracking of the measured inverter AC current to its reference value even at a low sampling frequency of 5KHz. The proposed RNN current controller also proved to perform better than the built-in three-pole-three-zero (3P3Z) current controller provided by TI and produce lower values of Total Harmonic Distortion (THD).

digital signal processor↗

Decentralized Voltage Control with Peer-to-peer Energy Trading in a Distribution Network

Utilizing distributed renewable and energy storage resources via peer-to-peer (P2P) energy trading has long been touted as a solution to improve energy system’s resilience and sustainability. Consumers and prosumers (those who have energy generation resources), however, do not have expertise to engage in repeated P2P trading, and the zero-marginal costs of renewables present challenges in determining fair market prices. To address these issues, we propose a multi-agent reinforcement learning (MARL) framework to help automate consumers’ bidding and management of their solar PV and energy storage resources, under a specific P2P clearing mechanism that utilizes the so-called supply-demand ratio. In addition, we show how the MARL framework can integrate physical network constraints to realize decentralized voltage control, hence ensuring physical feasibility of the P2P energy trading and paving ways for real-world implementations.

Feng, Chen↗

The NREL Sensor Laboratory Detection of Hydrogen Emissions

The development of a functional hydrogen detection system is a multifaceted process that integrates hardware, deployments strategies, and analytics which can be supported by the NREL Sensor Laboratory: 1. Support of the design, validation and optimization of sensing prototypes; 2. Guide optimized sensing element development, including control electronics; 3. Laboratory testing to validate/optimize metrological performance (measurement range, detection limit, etc.); 4. Provide test sites for field deployments representative of real-world scenarios with controlled hydrogen releases; 5. Develop sensor placement and operation guidance; 6. Provide guidance on electronics to accommodate facility integration; 7. Electrical safety designs to allow for operation within restricted zones; 8. Integration into facility monitoring and control systems; 9. Guide incorporation of cyber security elements to protect facilities from malicious attacks; 10. Modeling and application of advanced analytics to detect and quantify emissions; 11. Higher Order dispersion models to guide sensor placement for reliable detection; 12. Advanced analytics for improved metrological performances, and to inform inverse modeling; 13. Market support and commercialization (national and international markets); 14. Commercial deployments in H2@SCALE markets (e.g., HUBs and other large-scale hydrogen markets); and 15. Leverage off international collaborations/partnerships (e.g., NREL is on the advisory board for the European initiative "pre-Normative Research on Hydrogen Releases Assessment"-NHyRA).

08 HYDROGEN↗

Evaluating Function-as-a-Service (FaaS) frameworks for the Accelerator Control System

As particle accelerator control systems evolve in complexity and scale, the need for responsive, scalable, and cost-effective computational infrastructure becomes increasingly critical. Function-as-a-Service (FaaS) offers an alternative to traditional monolithic architecture by enabling event-driven execution, automatic scaling, and fine-grained resource utilization. This paper explores the applicability and performance of FaaS frameworks in the context of a modern particle accelerator control system, with the objective of evaluating their suitability for short lived and triggered workloads. In this paper, we evaluate prominent open-source FaaS platforms in executing functional logic, triggers, and diagnostics routines. Evaluation metrics consist of cold-start latency, scalability, performance, integration with other open-source tools like Kafka. Experimental workloads were designed to simulate real-world control tasks when implemented as stateless FaaS functions. These workloads were benchmarked under various invocation loads and network conditions. Self-hosted FaaS platforms, when deployed within accelerator networks, offer greater control over execution environment, better integration with legacy systems, and support for real-time guarantees when paired with message queues. Based on lessons learned and evaluation metrics, this paper describes reliability of the FaaS framework for the Accelerator Control Systems (ACS).

Jaikar, A. [Fermilab] (ORCID:0000000332046217)↗