Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hyperspectral”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

An assessment of the impact of system spectral response parameters on spectral shape and algal bloom detection for the GeoXO ocean color instrument (OCX)

NOAA’s Geostationary Extended Observations (GeoXO) program is planning to include a hyperspectral ocean color instrument (OCX) in geostationary orbit slated for operations by the early 2030s. Shared international focus has led to a diverse legacy of space-based remote sensing ocean color missions that have and will continue to provide ocean color products into the future at a variety of spatial, temporal, and spectral resolutions. This work reports on an investigation of the impacts of system spectral response parameters on spectral shape and algal bloom detection for the planned OCX instrument. A large dataset in-situ spectra, from a variety of locations and water cases collected with an above water spectrometer, was used to simulate OCX observations of varying system spectral response parameters. The OCX Performance Operational Requirements Document (PORD) level spectral resolution and sampling are varied concurrently and the location of band centers is varied independently. The impacts to the spectral shape using hyperspectral signature analysis, as well as the impacts to two heritage multispectral algal bloom detection algorithms – red band difference (RBD) and Karenia brevis bloom index (KBBI) – are assessed considering both changes in resolution/sampling and band center location. This work provides a quantitative assessment of the impacts of system spectral response requirements on both the spectral shape of observations as well as the algal bloom detection to provide insight on how various instrument performance parameters influence science and operational utility of OCX.

Monica Cook↗

An Initial Assessment of the Impact of System Spectral Response Parameters on Driving Ocean Color Applications for the GeoXO Ocean Color Instrument (OCX)

NOAA’s Geostationary Extended Observations (GeoXO) program is planning to include a hyperspectral ocean color instrument (OCX) in geostationary orbit slated for operations by the early 2030s. Shared international focus has led to a diverse legacy of space-based remote sensing ocean color missions that have and will continue to provide ocean color products into the future at a variety of spatial, temporal, and spectral resolutions. This work reports on an investigation of the impacts of system spectral response parameters on spectral shape and algal bloom detection for the planned OCX instrument. A dataset of high resolution (1 nm spectral sampling) in-situ spectra of red tide collected with an above water spectrometer, and associated K. brevis cell concentrations, were used to simulate OCX observations of varying system spectral response parameters. The OCX Performance Operational Requirements Document (PORD) level spectral resolution and sampling are varied concurrently and the location of band centers is varied independently. The impacts to the spectral shape using hyperspectral signature analysis, as well as the impacts to two heritage multispectral algal bloom detection algorithms – red band difference (RBD) and Karenia brevis bloom index (KBBI) – are assessed considering both changes in resolution/sampling and band center location. This work provides a quantitative assessment of the impacts of system spectral response requirements on both the spectral shape of observations as well as the algal bloom detection to provide insight on how various instrument performance parameters influence science and operational utility of OCX. Future work will seek to expand this analysis to include a larger dataset that considers additional water cases.

M. Cook↗

Reference Intercalibration for the Climate Observing System

Reference Intercalibration is critical in supporting the construction of climate data records, which, given their necessary longevity, must consist of measurements from multiple instruments. Reference intercalibration enables placing multiple instruments on the same radiometric scale, reducing calibration-based biases in climate data records. Measurements that have characteristics of a climate benchmark make excellent in-orbit intercalibration references. Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) consists of a reflected solar (RS) spectrometer (350-2300 nm) that will take hyperspectral Earth reflectance measurements with unprecedented SI-traceable accuracy (0.3%, 1-sigma) from the International Space Station (ISS). CPF measurements will have several characteristics of climate benchmark measurements and will demonstrate its capability as a rigorous in-orbit intercalibration reference with Clouds and Earth’s Radiant Energy System (CERES) and Visible Infrared Imaging Radiometer Suite (VIIRS). The methodologies that have been developed to support CPF-CERES and CPF-VIIRS intercalibration can readily be extended to other Low Earth Orbit and Geostationary instrument targets. With its highly accurate hyperspectral observations, CPF measurements can also be used to improve the characterization of targets widely used for satellite instrument vicarious calibration including Earth land surface pseudo-invariant calibration sites, deep convective clouds, and the Moon. We will discuss the importance of climate benchmark measurement attributes for intercalibration and considerations for the associated intercalibration data analysis to support building and maintaining climate data records.

Yolanda Shea↗

Fast Radiative Transfer Model and Retrieval Algorithm Development for Satellite Remote Sensing Applications

The radiative transfer model (RTM) has a wide range of applications in satellite remote sensing and atmospheric radiation studies. For example, it can be used as a forward model for an inversion algorithm and a satellite data assimilation system, or as a L1 data simulator for pre-launch end-to-end satellite sensor performance studies. However, millions of line-by-line (LBL) radiative transfer calculations at fine monochromatic frequencies are needed in order to properly calculate spectral contributions of water vapor and trace gases in the atmosphere in infrared and solar spectral regions. Therefore, fast, and accurate radiative transfer models are needed. A Principal Component-based radiative transfer model (PCRTM) was developed at NASA Langley to fulfil this need. The PCRTM can simulate the top-of-atmosphere (TOA) radiance or reflectance spectra from 250 nm to 2000 micrometers with several orders of magnitude faster speed as compared to a LBL RTM. It is also extremely accurate compared to LBL RTM benchmarks. The PCRTM model has been developed for hyperspectral sensors such as AIRS, CrIS, IASI, NAST-I, SHIS, CPF, TEMPO, EMIT, OMI, and SCIAMACHY. By using the PCRTM as forward model for an inversion algorithm, one can reduce the data dimension significantly while maintaining original information content by compressing the TOA radiance spectrum into PC-scores. The PCRTM can directly compute the PC-scores and their derivatives with respect to retrieved parameters. Examples of using various PCRTM inversion algorithms to retrieve atmospheric temperature, water vapor, and trace gas profiles, as well as cloud and surface properties from satellite hyperspectral remote sensors will be given. Some of the algorithms have been transitioned to NASA's Goddard Earth Sciences Data and Information Services Center (GES DISC) for public access of high-quality L2 and L3 data.

Xu Liu↗

Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC): A Payload Designed for Exploration of Terrestrial Planetary Bodies

Geological materials (indeed, all solid objects) are characterized by their crystal structure, elemental composition, and morphology. The Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC) instrument suite quantifies all three. These measurements address fundamental science questions (e.g., the origin and evolution of planetary bodies) and support the human exploration of space (e.g., the characterization of regolith for ISRU and the constraint of its geotechnical properties). METRIC comprises an X-ray Diffraction/X-ray Fluorescence instrument (XRD: mineral structure and XRF: elemental composition), an X-ray micro-Computed Tomography instrument (XCT: 3D internal micromorphology), and a hyperspectral imaging infrared spectrometer (IRS) to provide local/regional mineralogic context for these measurements. METRIC XRD/F draws heritage from the highly successful Mars Science Laboratory CheMin instrument. The METRIC XRD/F employs two separate sample cells, one optimized for XRD and one for XRF, resulting in more rapid XRD analysis (tens of minutes vs. tens of hours for CheMin) and an orders-of-magnitude improvement in XRF detection. XCT has not been deployed in space, so the METRIC XCT represents a new capability for solar system exploration. The XCT uses the same basic high-TRL components as METRIC XRD/F, decreasing its development cost for flight. The METRIC IRS is a derivative of the NASA Earth Science Technology Office funded Hyperspectral Thermal Imager instrument and utilizes the NASA Technology Transfer Program to incorporate a commercial-of-the-shelf infrared camera ruggedized for space by NASA Marshall Space Flight Center. The IRS spectral range (8–14 µm) and resolution (10.8 cm -1 ) are tailored to quantify mineralogy in rocks using their characteristic Reststrahlen bands and to characterize mineralogy of soils using the position of the Christensen Feature. The METRIC payload is currently designed for deployment to the Moon on a Commercial Lunar Payload Services (CLPS) mission, where the XRD/F and XCT would be located on a lander and the IRS would be on deployed on a companion rover to evaluate the mineralogical diversity of the landing site. A pneumatic drill designed by Honeybee Robotics would excavate regolith up to 50 cm below the lander and deliver multiple aliquots of regolith to the XRD/F and XCT. The METRIC payload could also be deployed on a rover. In this case, a sample handling system on a robotic arm could scoop regolith and/or drill rocks and deliver powder to the XRD/F and XCT located in the rover’s interior. Alternatively, METRIC instruments could be used singly or in combination on human space missions. The XRD/F and XCT could be used to characterize samples in a rover or in a science laboratory within a habitat. These data could help astronauts identify resource-enriched rocks and regolith and triage geologic samples to return samples of high interest for analysis in terrestrial laboratories. The IRS could be attached to a human-navigated rover to collect mineralogical data along a traverse and identify high-priority science samples.

E. B. Rampe↗

Numerical Weather Prediction Impact of GEO and LEO IR Sounders in an OSSE Framework

Low Earth Orbit (LEO) hyperspectral radiances from instruments such as CrIS, AIRS, and IASI are essential to NWP (among many other applications!), providing high vertical resolution T and humidity information. The United States is considering launching a hyperspectral sounder into a Geostationary Orbit (GEO) in the 2030s, creating a global ring with international partners. The combination of sounders in LEO and GEO provide both global coverage and high temporal resolution regional observations with the capability to dwell on high impact weather events.

Erica McGrath-Spangler↗

PACE OCI Lunar Calibration: Initial Results

Launched in February 2024, the Ocean Color Instrument (OCI) onboard NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission has started performing its monthly lunar calibrations at ±7degreeslunar phase angle in March 2024. In this paper, we will describe the OCI lunar calibration methodology and show the results of lunar calibration events during the initial months of PACE/OCI operation. A key difference of OCI lunar calibration from heritage sensors is that the lunar disk integrated irradiance is computed from lunar pixel radiance and sampling distance instead of the instrument’s IFOV. PACE provided a near constant sweep rate during lunar calibration allowing accurate determination of OCI pixel sampling extent. OCI performs lunar calibration in baseline science mode with 282 hyperspectral bands from 315 –895 nm and 7 shortwave infrared bands(940 -2260 nm). For each OCI band, we compute the integrated lunar disk irradiance, and compare the result with a lunar irradiance model (ROLO)prediction. The early results presented here clearly show that OCI’s lunar image acquisition is working as intended and will provide accurate data for OCI’s on-orbit radiometric characterization. The hyperspectral lunar irradiances provided by OCI are expected to become a valuable data set for the evaluation of lunar irradiance models.

calibration↗

Pre-Launch Analysis and Test of the Ocean Color Instrument Modulation Transfer Function

Launched in February 2024, the Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. The Ocean Color Instrument (OCI) is the primary instrument supporting PACE by collecting accurate radiometric data of the Earth by observing the top of atmosphere reflectance and is a combination hyperspectral (ultra-violet to near infrared) / multiband imager (shortwave infrared). An important aspect of the radiometry is the ability of OCI to resolve contrast from scene to scene to achieve data accuracy requirements. This paper reviews the analysis that was performed to verify the modulation transfer function requirement levied against the instrument and presents the supportive test data collected during pre-launch instrument testing to supplement the analysis. The requirements levied against OCI drove to a 1.2 km2 ground resolution leading to a Nyquist period of 2.4 km (0.417 cycles / km). The analysis is comprehensive with incorporation of as many contributors as practical to provide the clearest possible picture of the margin against requirements. The analysis provided input for additional design trade studies and insight into the aspects of the design that required the most attention during the implementation phase. We describe four separate MTF contributor networks based on the instrument design and mutual exclusivity of contributing factors. The various networks represent the hyperspectral and multiband detection systems separately as well as the along track and cross track imaging dimensions. Ground-test was performed against the MTF primary contributors and the results were used to validate the analysis as will be presented here.

OCI↗

Overview of NASA's Ocean Color Instrument Solar Calibration Architecture, Pre-Launch Tests and Preliminary On-Orbit Results

Launched in February 2024, the PACE mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. Like its predecessors, OCI will provide two day global coverage of TOA radiances. Unlike its predecessors, OCI will cover a spectral range from 340nm to 2260nm. Below 900nm, OCI will include two spectrometers that continuously span the ultraviolet to 600nm and 600nm to near-infrared spectral regions to provide hyperspectral radiances sampled every 2.5 nm, with a bandwidth of 5 nm for each channel. Wavelengths above 900nm are measured in seven discrete multispectral bands of varying bandwidths, six of which are at similar wavelengths to those on heritage missions to support both atmospheric and ocean color applications. Nominal spatial resolution is similar to the SeaWiFS instrument with 1050 m at nadir. As for SeaWiFS, the pixel size increases due to a ~20 degree tilt and as a function of scan angle. Variations in the radiometric sensitivity of each OCI channel over time will be monitored by solar diffuser measurements for short term instrument gain adjustments and independent lunar measurements for trend adjustments of long time periods, similar to the approach employed for the VIIRS instrument [4]. The OCI flight-unit was built at NASA’s Goddard Space Flight Center. At the time of this writing, OCI has completed on-orbit commissioning activities and normal science operations have begun. A key aspect of the OCI architecture is the capability to trend absolute and relative calibration changes over the course of mission life with solar calibration. Every 24 hours, the PACE spacecraft performs an inertial hold as the ground track nears the North Pole which orients a Quasi-Volume Diffuser (QVD) mounted on OCI towards the sun. By knowing the irradiance of the sun and the reflectivity of the target, the absolute radiance at the input to the OCI aperture can be computed as OCI scans the target. The allowable absolute uncertainty budget for each solar calibration measurement is 1.6% 1-sigma below 900nm at beginning of life (BOL) and the allowable relative uncertainty budget is ~0.26% 1-sigma. The Solar Calibration Assembly (SCA) consists of three targets selectable via a single mechanism which also opens a door. The targets consist of a Daily Bright Target (DBT), Monthly Bright Target (MBT), and Daily Dim Target (DDT). The bright targets are quartz QVDs with the monthly target being used to track the degradation of the daily target. The dim target is used to track CCD linearity using Progressive Time-Delay Integration (PTDI). A composite baffle is attached to the SCA housing aperture to block Earth shine and stray light from the spacecraft. The SCA assembly is mounted to a view port ~90° from OCI nadir. This paper provides an overview of driving solar calibration requirements, error-budgets and early trade studies which drove the solar calibration assembly (SCA) architecture and on-orbit maneuver. Measurements of the diffuser Bidirectional Reflectance Distribution Function (BRDF) at TNO, Netherlands and GSFC are briefly described. Optical modelling and test results at the sub-system and instrument level are included. Finally, preliminary measurements on-orbit are compared to pre-launch predictions.

Joseph J Knuble↗

Enabling the Assimilation of CrIS Shortwave Infrared Observations in Global NWP at NOAA. Part II: OSEs and Results

The assimilation of data from hyperspectral infrared sounders in global data assimilation systems has historically been focused on observations in the longwave infrared (LWIR) region of the spectrum (650-1100 cm−1), despite the often concurrent availability of measurements from the shortwave infrared (SWIR) region of the spectrum (2150-2550 cm−1), because issues (like solar effects) have generally prevented the assimilation of SWIR observations. Recent advances in radiative transfer models have worked to address some of the previous challenges in simulating SWIR observations, and the assimilation of SWIR data (e.g. from potential future small-satellites) is now a feasible prospect. Still, a better understanding of how these observations perform in a data assimilation system and impact resulting analyses and NWP forecasts is necessary. In this study, the value of SWIR observations in global NWP is assessed by assimilating SWIR observations from the Cross-track Infrared Sounder (CrIS) in NOAA’s Global Data Assimilation System (GDAS). The methodologies used to enable the assimilation of these observations, including the implementation of a scene-dependent observation error and the enhancement of quality control procedures, are discussed, as are the results of Observing System Experiments (OSEs) conducted to evaluate the impact of assimilating SWIR observations on forecast skill. The overall results show that SWIR assimilation produces similar forecast impacts to LWIR assimilation. The ability to demonstrate that the assimilation or SWIR observations in NWP is a realistic prospect may help to shape future constellations of small-satellites to serve as a beneficial complement to the current constellation if hyperspectral IR sounders.

Erin Jones↗

Pre-Launch Analysis and Test of the Ocean Color Instrument Modulation Transfer Function

Launched in February 2024, the Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. The Ocean Color Instrument (OCI) is the primary instrument supporting PACE by collecting accurate radiometric data of the Earth by observing the top of atmosphere reflectance and is a combination hyperspectral (ultra-violet to near infrared) / multiband imager (shortwave infrared). An important aspect of the radiometry is the ability of OCI to resolve contrast from scene to scene to achieve data accuracy requirements. This paper reviews the analysis that was performed to verify the modulation transfer function requirement levied against the instrument and presents the supportive test data collected during pre-launch instrument testing to supplement the analysis. The requirements levied against OCI drove to a 1.2 km2 ground resolution leading to a Nyquist period of 2.4 km (0.417 cycles / km). The analysis is comprehensive with incorporation of as many contributors as practical to provide the clearest possible picture of the margin against requirements. The analysis provided input for additional design trade studies and insight into the aspects of the design that required the most attention during the implementation phase. We describe four separate MTF contributor networks based on the instrument design and mutual exclusivity of contributing factors. The various networks represent the hyperspectral and multiband detection systems separately as well as the along track and cross track imaging dimensions. Ground-test was performed against the MTF primary contributors and the results were used to validate the analysis as will be presented here.

OCI↗

Using Polarized PCRTM-Solar Model to Validate EMIT Surface Reflectance L2A Product

Using the vector linearized discrete ordinate radiative transfer model (VLIDORT), a multiple-scattering multi-layer scattering code, coupled with a fast principal component (PC) radiative transfer model (PCRTM), we can simulate hyperspectral radiation fields from visible to shortwave infrared (VSWIR), i.e., 250 nm to 2500 nm. Since only limited accurate line-by-line calculation using VLIDORT is needed, this coupled PCRTM-VLIDORT approach is very efficient for simulating hyperspectral VSWIR spectra. These simulations incorporate accurately defined optical properties (gas absorptions, molecular and aerosol/cloud particle scattering) and detailed surface reflectance inputs. In this study we used the current L2A products of the Earth Surface Mineral Dust Source Investigation (EMIT) imaging spectrometer as the inputs to PCRTM-VLIDORT to simulate EMIT spectra. Comparing the simulated spectra with EMIT measurements provides an efficient method to validate the current EMIT product.

Xiaozhen Xiong↗

Standoff imaging of chemicals using IR spectroscopy

Here we report on a standoff spectroscopic technique for identifying chemical residues on surfaces. A hand-held infrared camera was used in conjunction with a wavelength tunable mid-IR quantum cascade laser (QCL) to create hyperspectral image arrays of a target with an explosive residue on its surface. Spectral signatures of the explosive residue (RDX) were extracted from the hyperspectral image arrays and compared with a reference spectrum. Identification of RDX was achieved for residue concentrations of 20 g per cm2 at a distance of 1.5 m, and for 5 g per cm2 at a distance of 15 cm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Joint spatio-spectral based edge detection for multispectral infrared imagery.

Image segmentation is one of the most important and difficult tasks in digital image processing. It represents a key stage of automated image analysis and interpretation. Segmentation algorithms for gray-scale images utilize basic properties of intensity values such as discontinuity and similarity. However, it is possible to enhance edge-detection capability by means of using spectral information provided by multispectral (MS) or hyperspectral (HS) imagery. In this paper we consider image segmentation algorithms for multispectral images with particular emphasis on detection of multi-color or multispectral edges. More specifically, we report on an algorithm for joint spatio-spectral (JSS) edge detection. By joint we mean simultaneous utilization of spatial and spectral characteristics of a given MS or HS image. The JSS-based edge-detection approach, termed Spectral Ratio Contrast (SRC) edge-detection algorithm, utilizes the novel concept of matching edge signatures. The edge signature represents a combination of spectral ratios calculated using bands that enhance the spectral contrast between the two materials. In conjunction with a spatial mask, the edge signature give rise to a multispectral operator that can be viewed as a three-dimensional extension of the mask. In the extended mask, the third (spectral) dimension of each hyper-pixel can be chosen independently. The SRC is verified using MS and HS imagery from a quantum-dot in a well infrared (IR) focal plane array, and the Airborne Hyperspectral Imager.

99 GENERAL AND MISCELLANEOUS↗

imageMCR

imageMCR is a user friendly software package that consists of a variety inputs to preprocess and analyze the hyperspectral image data using multivariate algorithms such as Multivariate Curve Resolution (MCR), Principle Component Analysis (PCA), Classical Least Squares (CLS) and Parallel Factor Analysis (PARAFAC). MCR provides a relative quantitative analysis of the hyperspectral image data without the need for standards, and it discovers all the emitting species (spectral pure components) present in an image, even those in which there is no a priori information. Once the spectral components are discovered, these spectral components can be used for future MCR analyses or used with CLS algorithms to quickly extract concentration image maps for each component within spectral image data sets.

Source record↗

HyperMic

HyperMic is the control software for the Hyperspectral Confocal Microscope, and is required for the use of the microscope. It interfaces with, and controls the main subsystems of the microscope including the EMCCD detector, the video camera, the XYZ stage system, the optical shutters, the filter wheels, and the illumination sources. It allows the user to select regions to image, and acquire and save hyperspectral images. HyperMic is capable of acquiring single (2-dimensional) image frames or full 3-dimensional image stacks.

Sinclair, Michael 8↗

Raman Microscopy Analysis of Wyoming CarbonSAFE Pilot Well Thin Sections for Mineralogy and Organic Matter Characterization

Scanning confocal Raman microspectroscopy (RMS) was used to analyze thin sections for inorganic mineral content and for evaluation of organic material (OM). Thin sections were selected from a stratigraphic test well core in the Powder River Basin, Wyoming under the Wyoming CarbonSAFE project. The well was analyzed with a variety of rock and fluid characterization techniques to determine the feasibility of a commercial-scale CO2 storage site. RMS complements other analyses, including traditional petrography, SEM, porosity and permeability, and XRD For this aspect of the study, RMS is especially important in the evaluation of OM in sealing lithologies. At prospective geologic CO2 storage sites, it is imperative to assess the unconventional oil and gas potential of seals to ensure that any future development would not compromise the integrity of the seals. Whole-slide mineralogical surveys were performed on thin sections from various shale and sandstone formations. Surveys were analyzed with Direct Classical Least Squares to identify and quantify minerals. The location and concentration of minerals was color-coded and overlaid on optical images for visualization of the distribution of minerals. Dense hyperspectral Raman mapping of OM was performed on five thin sections. Eleven spectral parameters diagnostic of organic type and thermal maturity were used to train a Partial Least Squares (PLS) calibration against a set of artificially matured samples spanning the pre- to mid-oil window. The PLS was applied to the study set and a post-mature set. Additionally, the PLS was applied to each point in hyperspectral maps for visualization of trends in maturity across sample sets and discrimination of organic matter types within a given map. In inorganic surveys on thin sections, a total of 14 unique inorganic minerals were identified in Raman spectra including quartz, dolomite, calcite, hematite and anhydrite. Shale thin sections tended to be dominated by organic material. OM was often observed mixed with inorganic minerals. Sand- and mudstones were dominated by inorganic minerals. The PLS extrapolated the post-mature set to reflectances >1.2%. The study set ranged from very immature to postmature in the median of map fit-peak parameters. However, point maturity maps indicate that matrix OM in all study samples is immature and that discreet organic particles selected for mapping, which may be inertinites, bias medians towards more-mature. The work demonstrates the capabilities of RMS to perform both whole-slide mineralogy and OM analysis with applications to formation evaluation in oil & gas, carbon sequestration and mining. Here, analysis of sealing formations in the well indicates high levels of immature organic matter that would not be a viable target for future oil production that could compromise the CO2 storage site. The work brings together diverse disciplines from geology and petrography to analytical chemistry, big data and microscopy.

Myers, Grant↗

In-line, High-Throughput Quality Monitoring for Fuel Cell and Electrolyzer Components Based on Transmission and Reflection Imaging

During the manufacturing of fuel cell and electrolyzer membranes and membrane electrode assemblies (MEAs), real-time, in-line, high-throughput optical-based quality monitoring methods are essential for detecting defects and monitoring thickness variations, thus improving the performance and increasing the durability of fuel cell and electrolyzer in the hydrogen industry. For the MEAs with very opaque coatings, optical transmission-based imaging has been developed and applied in the Roll-to-Roll system using a flashlight and a high-sensitivity CCD camera. We observed high signal-to-noise ratio images while the Roll-to-Roll system ran at 5 ft/min. The entire sample image could quickly be recovered from the discrete frames using customized Python codes for automatic frame cropping and stitching. We detected significant non-uniformities in our experimental MEAs specimen. For fuel cell and low-temperature electrolysis (LTE) transparent membranes, we used optical reflectance hyperspectral imaging with interference fringe-based thickness mapping. We set up a hyperspectral camera to measure various rolls of commercial membranes. The measurement results are analyzed to find the thickness distribution of each roll and to check for defects. Transmission and reflection imaging-based quality monitoring techniques demonstrated in this project can be widely used in the mass production environment to improve the production yield and performance of hydrogen devices.

DIRECT ENERGY CONVERSION,ENGINEERING↗