Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high resolution spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Irradiation-induced amorphization of UO 2 films prepared by spraying-assisted combustion synthesis

Spraying-assisted combustion synthesis with uranyl nitrate – acetylacetone – 2-methoxyethanol solutions was used to prepare UO 2 films on an aluminum alloy substrate. The tuning of the spraying parameters and annealing temperatures allowed the preparation of UO 2 films with thicknesses varying from 10–300 nm and 5–10 nm UO 2 grain size. High-resolution electron microscopy and X-ray photoelectron spectroscopy showed that increasing the annealing temperature promotes Mg diffusion from the substrate into the films. The incorporation of Mg reduced the overall crystallinity of the films. The irradiation with Ar 2+ ions (1.7 MeV energy and a fluence of 2 × 10 16 ions/cm 2 ) did not degrade the quality of the films. However, the Mg content significantly influenced the irradiation-induced restructuring of the UO 2 films. Irradiated films with low or no Mg content exhibit high crystallinity, and the UO 2 /Al interfacial layer becomes highly porous. Films with higher Mg content are mostly amorphized after irradiation. The origin of irradiation-induced amorphization was related to the formation of Mg y U 1-y O 2±x solid solutions. Chemically complex, pore-free, and amorphous Mg-Al-O film/substrate interfacial layers enable continuous Mg diffusion during irradiation. As a result, the gradual increase in Mg amounts triggers irradiation-induced precipitation of a crystalline MgO-rich phase within the amorphous films.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Balloon-borne three-meter telescope for far-infrared and submillimeter astronomy

Presented are scientific objectives, engineering analysis and design, and results of technology development for a Three-Meter Balloon-Borne Far-Infrared and Submillimeter Telescope. The scientific rationale is based on two crucial instrumental capabilities: high angular resolution which approaches eight arcseconds at one hundred micron wavelength, and high resolving power spectroscopy with good sensitivity throughout the telescope's 30-micron to 1-mm wavelength range. The high angular resolution will allow us to resolve and study in detail such objects as collapsing protostellar condensations in our own galaxy, clusters of protostars in the Magellanic clouds, giant molecular clouds in nearby galaxies, and spiral arms in distant galaxies. The large aperture of the telescope will permit sensitive spectral line measurements of molecules, atoms, and ions, which can be used to probe the physical, chemical, and dynamical conditions in a wide variety of objects.

Fazio, G. G.↗

Synthesis of Honeycomb-Structured Beryllium Oxide via Graphene Liquid Cells

Using high-resolution transmission electron microscopy and electron energy-loss spectroscopy, we demonstrate that beryllium oxide crystallizes in the planar hexagonal structure in a graphene liquid cell by a wet-chemistry approach. These liquid cells can feature van-der-Waals pressures up to 1 GPa, producing a miniaturized high-pressure container for the crystallization in solution. The thickness of as-received crystals is beyond the thermodynamic ultra-thin limit above which the wurtzite phase is energetically more favorable according to the theoretical prediction. The crystallization of the planar phase is ascribed to the near-free-standing condition afforded by the graphene surface. Our calculations show that the energy barrier of the phase transition is responsible for the observed thickness beyond the previously predicted limit. These findings open a new door for exploring aqueous-solution approaches of more metal-oxide semiconductors with exotic phase structures and properties in graphene-encapsulated confined cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The 2RE J0241-525: A Nearby Post T-Tauri Visual Binary System

We present high spatial resolution X-ray observations, photometry and spectroscopy of the two low mass, active stars proposed as optical counterparts to the extreme ultraviolet source 2RE J0241-525 (equal to EUVE J0241-530). It is confirmed that both stars, which are of types dK7e and dM3e and separated by 22 arcsecs, are sources of soft X-ray emission and exhibit substantial chromospheric activity. Radial velocity measurements indicate that the two components are physically associated and most probably single. The projected equatorial velocities are measured as (75 +/- 3) km/s and (11.7 +/- 0.7) km/s for the hotter and cooler components, respectively, and whilst the hotter component has a relatively high photospheric lithium abundance, log N(Li) equal to 1.5 +/- 0.2, we are unable to detect any lithium in the cooler star. Isochrone fitting to this 'mini-cluster' yields an age of (3-70) Myr and a distance of (19-60) pc. An empirical comparison of the lithium abundances with those for similar stars in young clusters and associations narrows this age range to (5-30) Myr and a corresponding distance of (26-50) pc. We conclude that this object is a nearby post T-Tauri system, but we cannot locate any possible birth site. It appears unlikely that the system can have been ejected from a nearby open cluster in a two or three body encounter.

Jeffries, R. D.↗

Operational characteristics of Wedge and Strip image readout systems

Application of the Wedge and Strip readout system in microchannel plate detectors for the Extreme Ultraviolet Explorer and FAUST space astronomy programs is discussed. Anode designs with high resolution (greater than 600 x 600 pixels) in imaging and spectroscopy applications have been developed. Extension of these designs to larger formats (100 mm) with higher resolution (3000 x 3000 pixels) are considered. It is shown that the resolution and imaging are highly stable, and that the flat field performance is essentially limited by photon statistics. Very high speed event response has also been achieved with output pulses having durations of less than 10 nanoseconds.

Siegmund, O. H. W.↗

Underlying simplicity of 5f unoccupied electronic structure

Using a simple empirical model based upon the bremsstrahlung isochromat spectroscopy of elemental Th, it is possible to explain the recent high energy resolution fluorescence detection measurements of UF 4 (n = 2) and UCd 11 (n = 3) as well as the new inverse photoelectron spectroscopy of Pu 2 O 3 (n = 5), where n is the 5f occupation number. Furthermore, a critical issue in this analysis is the assumption that the Th 5f states are essentially empty, which will be confirmed both experimentally and computationally. Thus, for 5f systems, this simple model provides a unified and consistent picture of 5f unoccupied density of states in simple, localized systems, as the 5f occupation varies in the early part of the series, for n = 0, 2, 3, and 5.

36 MATERIALS SCIENCE↗

Unveiling the parasitic-reaction-driven surface reconstruction in Ni-rich cathode and the electrochemical role of Li 2 CO 3

Nickel-rich transition-metal oxides are widely regarded as promising cathode materials for high-energy-density lithium-ion batteries for emerging electric vehicles. However, achieving high energy density in Ni-rich cathodes is accompanied by substantial safety and cycle-life obstacles. The major issues of Ni-rich cathodes at high working potentials are originated from the unstable cathode-electrolyte interface, while the underlying mechanism of parasitic reactions towards surface reconstructions of cathode materials is not well understood. In this work, we controlled the Li 2 CO 3 impurity content on LiNi 0.83 Mn 0.1 Co 0.07 O 2 cathodes using air, tank-air, and O 2 synthesis environments. Home-built high-precision leakage current and on-line electrochemical mass spectroscopy experiments verify that Li 2 CO 3 impurity is a significant promoter of parasitic reactions on Ni-rich cathodes. The rate of parasitic reactions is strongly correlated to Li 2 CO 3 content and severe performance deterioration of Ni83 cathodes. The post-mortem characterizations via high-resolution transition electron microscope and X-ray photoelectron spectroscopy depth profiles reveal that parasitic reactions promote more Ni reduction and O deficiency and even rock-salt phase transformation at the surface of cathode materials. Here, our observation suggests that surface reconstructions have a strong affiliation to parasitic reactions that create chemically acidic environment to etch away the lattice oxygen and offer the electrical charge to reduce the valence state of transition metal. Thus, this study advances our understanding on surface reconstructions of Ni-rich cathodes and prepares us for searching for rational strategies.

36 MATERIALS SCIENCE↗

The Composition of Comet C/2009 P1 (Garradd) from Infrared Spectroscopy: Evidence for an Oxygen-Rich Heritage?

Comets retain relatively primitive icy material remaining from the epoch of Solar System formation, however the extent to which their ices are modified remains a key question in cometary science. One way to address this is to measure the relative abundances of primary (parent) volatiles in comets (i.e., those ices native to the nucleus). High-resolution (lambda/delta lambda greater than 10(exp 4)) infrared spectroscopy is a powerful tool for measuring parent volatiles in comets through their vibrational emissions in the approximately 3-5 micrometer region. With modern instrumentation on world-class telescopes, we can quantify a multitude of species (e.g., H2O, C2H2, CH4, C2H6, CO, H2CO, CH3OH, HCN, NH3), even in comets with modest gas production. In space environments, compounds of keen interest to astrobiology could originate from HCN and NH3 (leading to amino acids), H2CO (leading to sugars), or C2H6, and CH4 (suggested precursors of ethyl- and methylamine). Measuring the abundances of these precursor molecules and their variability among comets contributes to understanding the synthesis of the more complex prebiotic compounds.

DiSanti, M. A.↗

The Composition of Comet C/2009 PI (Garradd) from Infrared Spectroscopy: Evidence for an Oxygen-Rich Heritage?

Comets retain relatively primitive icy material remaining from the epoch of Solar System for111ation, however the extent to which their ices are modified remains a key question in cometary science. One way to address this is to measure the relative abundances of primary (parent) volatiles in comets (i.e., those ices native to the nucleus). High-resolution (lambda/delta lambda greater than 10(exp 4)) infrared spectroscopy is a powerful tool for measuring parent volatiles in comets through their vibrational emissions in the ~ 3-5 micrometer region. With modern instrumentation on worldclass telescopes, we can quantify a multitude of species (e.g., H2O, C2H2, CH4, C2H6 CO, H2CO, CH3OH, HCN, NH3), even in comets with modest gas production. In space environments, compounds of keen interest to astrobiology could originate from HCN and NH3 (leading to amino acids), H2CO (leading to sugars), or C2H6 and CH4 (suggested precursors of ethyl- and methylamine). Measuring the abundances of these precursor molecules and their variability among comets contributes to understanding the synthesis of the more complex prebiotic compounds.

DiSanti, M. A.↗

Hybrid MBE Route to Adsorption-Controlled Growth of BaTiO 3 Membranes with Robust Polarization Switching

Freestanding ferroelectric membranes are promising for flexible electronics, nonvolatile memory, photonics, and spintronics, but their synthesis is challenged by the need for reproducibility with precise stoichiometric control. Here, we demonstrate the adsorption-controlled growth of single-crystalline, epitaxial BaTiO 3 films by hybrid molecular beam epitaxy (MBE) on a binary oxide sacrificial layer. Using a simple water-droplet lift-off method, we obtained submillimeter- to millimeter-sized membranes that retained crystallinity, as confirmed by high-resolution X-ray diffraction, and exhibited robust tetragonal symmetry, as verified by Raman spectroscopy. Impedance spectroscopy confirmed a high dielectric constant of ∼1340, reflecting the robust dielectric response of the membranes. Ferroelectric functionality was revealed by piezoresponse force microscopy (PFM) and further verified by polarization-electric field (P-E) loop measurements with Positive-Up-Negative-Down (PUND). The P-E loops exhibited a remnant polarization of ∼5 μC cm –2 and a coercive field of ∼63 kV cm –1 . Furthermore, these results were interpreted in relation to c- and a-domain configurations.

Raman spectroscopy↗

The Large UV/Optical/Infrared Surveyor (LUVOIR): Decadal Mission Concept Design Update

In preparation for the 2020 Astrophysics Decadal Survey, NASA has commissioned the study of four large mission concepts, including the Large Ultraviolet / Optical / Infrared (LUVOIR) Surveyor. The LUVOIR Science and Technology Definition Team (STDT) has identified a broad range of science objectives including the direct imaging and spectral characterization of habitable exoplanets around sun-like stars, the study of galaxy formation and evolution, the epoch of reionization, star and planet formation, and the remote sensing of Solar System bodies. NASA’s Goddard Space Flight Center (GSFC) is providing the design and engineering support to develop executable and feasible mission concepts that are capable of the identified science objectives. We present an update on the first of two architectures being studied: a 15-meter-diameter segmented-aperture telescope with a suite of serviceable instruments operating over a range of wavelengths between 100 nm to 2.5 microns. Four instruments are being developed for this architecture: an optical / near-infrared coronagraph capable of 10(exp -10) contrast at inner working angles as small as 2 lambda/D; the LUVOIR UV Multi-object Spectrograph (LUMOS), which will provide low- and medium-resolution UV (100 – 400 nm) multi-object imaging spectroscopy in addition to far-UV imaging; the High Definition Imager (HDI), a high-resolution wide-field-of-view NUV-Optical-IR imager; and a UV spectro-polarimeter being contributed by Centre National d’Etudes Spatiales (CNES). A fifth instrument, a multi-resolution optical-NIR spectrograph, is planned as part of a second architecture to be studied in late 2017.

Decadal Study; Astrophysics; LUVOIR↗

The Large UV/Optical/Infrared Surveyor (LUVOIR): Decadal Mission Study Update

NASA commissioned the study of four large mission concepts, including the Large Ultraviolet / Optical / Infrared (LUVOIR) Surveyor, to be evaluated by the 2020 Decadal Survey in Astrophysics. In response, the Science and Technology Definition Team (STDT) identified a broad range of science objectives for LUVOIR that include the direct imaging and spectral characterization of habitable exoplanets around sun-like stars, the study of galaxy formation and evolution, the exchange of matter between galaxies, star and planet formation, and the remote sensing of Solar System objects. To meet these objectives, the LUVOIR Study Office, located at NASA's Goddard Space Flight Center (GSFC), completed the first design iteration of a 15-m segmented-aperture observatory that would be launched by the Space Launch System (SLS) Block 2 configuration. The observatory includes four serviceable instruments: the Extreme Coronagraph for Living Planetary Systems (ECLIPS), an optical / near-infrared coronagraph capable of delivering 10(exp -10) contrast at inner working angles as small as 2 lambda/D; the LUVOIR UV Multi-object Spectrograph (LUMOS), which will provide low- and medium-resolution UV (100 - 400 nm) multi-object imaging spectroscopy in addition to far-UV imaging; the High Definition Imager (HDI), a high-resolution wide-field-of-view NUV-Optical-NIR imager; and Pollux, a high-resolution UV spectro-polarimeter being contributed by Centre National d'Etudes Spatiales (CNES). The study team has executed a second design iteration to further improve upon the 15-m concept, while simultaneously studying an 8-m concept. In these proceedings, we provide an update on these two architectures.

cosmic origins↗

The Large UV/Optical/Infrared Surveyor (LUVOIR): Decadal Mission Concept Study Update

In preparation for the 2020 Decadal Survey in Astronomy and Astrophysics, NASA commissioned the study of four large mission concepts: the Large UV/Optical/Infrared Surveyor (LUVOIR), the Habitable Exoplanet Imager (HabEx), the far-infrared surveyor Origins Space Telescope (OST), and the X-ray surveyor Lynx. The LUVOIR Science and Technology Definition Team (STDT) has identified a broad range of science objectives for LUVOIR that include the direct imaging and spectral characterization of habitable exoplanets around sun-like stars, the study of galaxy formation and evolution, the exchange of matter between galaxies, star and planet formation, and the remote sensing of Solar System objects. The LUVOIR Study Office, located at NASA's Goddard Space Flight Center (GSFC), is developing two mission concepts to achieve the science objectives. LUVOIR-A is a 15-meter segmented-aperture observatory that would be launched in an 8.4-m extended fairing on the Space Launch System (SLS) Block 2 configuration. LUVOIR-B is an 8-meter unobscured segmented aperture telescope that fits in a smaller, conventional 5-meter fairing, but still requires the lift capacity of the SLS Block 1B Cargo vehicle. Both concepts include a suite of serviceable instruments: the Extreme Coronagraph for Living Planetary Systems (ECLIPS), an optical/near-infrared coronagraph capable of delivering 10 (sup minus10) contrast at inner working angles as small as 2 lambda divided by D; the LUVOIR UV Multi-object Spectrograph (LUMOS), which will provide low- and medium-resolution UV (100-400 nanometer) multi-object imaging spectroscopy in addition to far-UV imaging; the High Definition Imager (HDI), a high-resolution wide-field-of-view NUV-Optical-NIR imager. LUVOIR-A also has a fourth instrument, Pollux, a high-resolution UV spectro-polarimeter being contributed by Centre National d'Etudes Spatiales (CNES). This paper provides an overview of the LUVIOR science objectives, design drivers, and mission concepts.

Decadal Study↗

The Large UV/Optical/Infrared Surveyor (LUVOIR): Decadal Mission Concept Study Update

In preparation for the 2020 Decadal Survey in Astronomy and Astrophysics, NASA commissioned the study of four large mission concepts: the Large UV/Optical/Infrared Surveyor (LUVOIR), the Habitable Exoplanet Imager (HabEx), the far-infrared surveyor Origins Space Telescope (OST), and the X-ray surveyor Lynx. The LUVOIR Science and Technology Definition Team (STDT) has identified a broad range of science objectives for LUVOIR that include the direct imaging and spectral characterization of habitable exoplanets around sun-like stars, the study of galaxy formation and evolution, the exchange of matter between galaxies, star and planet formation, and the remote sensing of Solar System objects. The LUVOIR Study Office, located at NASA's Goddard Space Flight Center (GSFC), is developing two mission concepts to achieve the science objectives. LUVOIR-A is a 15-meter segmented-aperture observatory that would be launched in an 8.4-meter extended fairing on the Space Launch System (SLS) Block 2 configuration. LUVOIR-B is an 8-meter unobscured segmented aperture telescope that fits in a smaller, conventional 5-meter fairing, but still requires the lift capacity of the SLS Block 1B Cargo vehicle. Both concepts include a suite of serviceable instruments: the Extreme Coronagraph for Living Planetary Systems (ECLIPS), an optical/near-infrared coronagraph capable of delivering 10 (sup minus 10) contrast at inner working angles as small as 2 lambda divided by D; the LUVOIR UV Multi-object Spectrograph (LUMOS), which will provide low- and medium-resolution UV (100-400 nanometer) multi-object imaging spectroscopy in addition to far-UV imaging; the High Definition Imager (HDI), a high-resolution wide-field-of-view NUV-Optical-NIR imager. LUVOIR-A also has a fourth instrument, Pollux, a high-resolution UV spectro-polarimeter being contributed by Centre National d'Etudes Spatiales (CNES). This paper provides an overview of the LUVIOR science objectives, design drivers, and mission concepts.

Decadal Study↗

The Large UV/Optical/Infrared Surveyor (LUVOIR): Decadal Mission Study Update

NASA commissioned the study of four large mission concepts, including the Large Ultraviolet / Optical / Infrared (LUVOIR) Surveyor, to be evaluated by the 2020 Decadal Survey in Astrophysics. In response, the Science and Technology Definition Team (STDT) identified a broad range of science objectives for LUVOIR that include the direct imaging and spectral characterization of habitable exoplanets around sun-like stars, the study of galaxy formation and evolution, the exchange of matter between galaxies, star and planet formation, and the remote sensing of Solar System objects. To meet these objectives, the LUVOIR Study Office, located at NASA’s Goddard Space Flight Center (GSFC), completed the first design iteration of a 15-m segmented-aperture observatory that would be launched by the Space Launch System (SLS) Block 2 configuration. The observatory includes four serviceable instruments: the Extreme Coronagraph for Living Planetary Systems (ECLIPS), an optical / near-infrared coronagraph capable of delivering 10^-10contrast at inner working angles as small as 2 O/D; the LUVOIR UV Multi-object Spectrograph (LUMOS), which will provide low- and medium-resolution UV (100 – 400 nm) multi-object imaging spectroscopy in addition to far-UV imaging; the High Definition Imager (HDI), a high-resolution wide-field-of-view NUV-Optical-NIR imager; and Pollux, a high-resolution UV spectro-polarimeter being contributed by Centre National d’Etudes Spatiales (CNES).The study team has executed a second design iteration to further improve upon the 15-m concept, while simultaneously studying an 8-m concept. In these proceedings, we provide an update on these two architectures.

space telescopes↗

High Resolution, Non-Dispersive X-Ray Calorimeter Spectrometers on EBITs and Orbiting Observatories

X-ray spectroscopy is the primary tool for performing atomic physics with Electron beam ion trap (EBITs). X-ray instruments have generally fallen into two general categories, 1) dispersive instruments with very high spectral resolving powers but limited spectral range, limited count rates, and require an entrance slit, generally, for EBITs, defined by the electron beam itself, and 2) non-dispersive solid-state detectors with much lower spectral resolving powers but that have a broad dynamic range, high count rate ability and do not require a slit. Both of these approaches have compromises that limit the type and efficiency of measurements that can be performed. In 1984 NASA initiated a program to produce a non-dispersive instrument with high spectral resolving power for x-ray astrophysics based on the cryogenic x-ray calorimeter. This program produced the XRS non-dispersive spectrometers on the Astro-E, Astro-E2 (Suzaku) orbiting observatories, the SXS instrument on the Astro-H observatory, and the planned XMS instrument on the International X-ray Observatory. Complimenting these spaceflight programs, a permanent high-resolution x-ray calorimeter spectrometer, the XRS/EBIT, was installed on the LLNL EBIT in 2000. This unique instrument was upgraded to a spectral resolving power of 1000 at 6 keV in 2003 and replaced by a nearly autonomous production-class spectrometer, the EBIT Calorimeter Spectrometer (ECS), in 2007. The ECS spectrometer has a simultaneous bandpass from 0.07 to over 100 keV with a spectral resolving power of 1300 at 6 keV with unit quantum efficiency, and 1900 at 60 keV with a quantum efficiency of 30%. X-ray calorimeters are event based, single photon spectrometers with event time tagging to better than 10 us. We are currently developing a follow-on instrument based on a newer generation of x-ray calorimeters with a spectral resolving power of 3000 at 6 keV, and improved timing and measurement cadence. The unique capabilities of the x-ray calorimeter spectrometer, coupled with higher spectral resolution dispersive spectrometers to resolve line blends, has enabled many science investigations, to date mostly in our x-ray laboratory astrophysics program. These include measurements of absolute cross sections for Land K shell emission from Fe and Ni, charge exchange measurements in many astrophysically abundant elements, lifetime measurements, line ratios, and wavelength measurements. In addition, we have performed many additional measurements in nuclear physics, and in support of diagnostics for laser fusion, for example. In this presentation we will give a detailed overview of x-ray calorimeter instruments in general and in our EBIT laboratory astrophysics program in particular. We will also discuss the science yield of our measurements at EBIT over the last decade) prospects for future science enabled by the current generation of spectrometers and that will be expanded in the near future by the next generation of spectrometers starting in 2611.

Porter, Frederick S.↗

Hyperfine structure and isotope shifts of xenon measured for near-infrared transitions with Doppler-free saturated absorption spectroscopy

Hyperfine structure and isotope shifts of Xe were investigated with Doppler-free saturated absorption spectroscopy for all transitions in the 820-841 nm spectral interval. The Xe samples were commercial gases of natural isotopic abundances. The measurements were performed by employing a widely tunable narrow line Ti:sapphire laser. The hyperfine structures for 129 Xe and 131 Xe were well resolved. For the transitions with the wavelengths in vacuum near 820.860 nm and 841.150 nm also isotope shifts of the even isotopes were clearly observed. The modeling of the shapes of the observed absorption lines qualitatively reproduces experimental spectral profiles. The measured absorption peaks of the hyperfine structure and isotope shifts of Xe isotopes present characteristic spectral fingerprints for their identification. Eventually, quantitative spectral analysis will provide isotopic abundances of natural, as well as radioactive Xe gas samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Altered post-fracture systemic bone loss in a mouse model of osteocyte dysfunction

Femur fracture leads to loss of bone at uninjured skeletal sites, which may increase risk of subsequent fracture. Osteocytes, the most abundant bone cells, can directly resorb bone matrix and regulate osteoclast and osteoblast activity, but their role in systemic bone loss after fracture remains poorly understood. In this study we used a transgenic (TG+) mouse model that overexpresses human B-cell lymphoma 2 (BCL-2) in osteoblasts and osteocytes. This causes enhanced osteoblast proliferation, followed by disruption in lacunar-canalicular connectivity and massive osteocyte death by 10 wk of age. We hypothesized that reduced viable osteocyte density would decrease the magnitude of systemic bone loss after femur fracture, reduce perilacunar remodeling, and alter callus formation. Bone remodeling was assessed using serum biomarkers of bone formation and resorption at 5 d post-fracture. We used micro-computed tomography, high resolution x-ray microscopy, mechanical testing, and Raman spectroscopy to quantify the magnitude of systemic bone loss, as well as changes in osteocyte lacunar volume, bone strength, and bone composition 2 wk post-fracture. Fracture was associated with a reduction in circulating markers of bone resorption in non-transgenic (TG-) animals. TG+ mice exhibited high bone mass in the limbs, greater cortical elastic modulus and reduced post-yield displacement. After fracture, TG+ mice lost less trabecular bone than TG- mice, but conversely TG+ mice exhibited trends toward a lower yield point and reduced femoral cortical thickness after fracture, though these were not statistically significant. Lacunar density was greater in TG+ mice, but fracture did not alter lacunar volume in TG+ or TG- mice. These findings suggest that osteocytes potentially play a significant role in the post-traumatic systemic response to fracture, though the effects differ between trabecular and cortical bone.

60 APPLIED LIFE SCIENCES↗