Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Experimental Study on Portable Air-Conditioning System with Enhanced PCM Condenser

A portable personal air-conditioning system with a vapor compression cycle (VCC), electrical battery, and thermal battery is an attractive option for localized cooling as compared with stationary air-conditioning systems. A phase change material (PCM) can be used for storing waste heat from the VCC condenser, thereby acting as a thermal battery. In the PCM condenser, copper tubes are submerged in the PCM container. Due to the low thermal conductivity of pure PCM, the overall heat transfer coefficient of the PCM condenser is limited resulting in high VCC condensing pressure and thus, low VCC coefficient of performance (COP). Therefore, it is necessary to improve VCC system performances by applying heat transfer augmentation in PCM. In this work, a portable air-conditioning system with heat transfer enhanced PCM that stores heat from condenser during VCC operation and is regenerated by a thermosyphon operation is proposed. The system also includes a receiver to address the charge difference between the thermosyphon and the VCC operation. The paper experimentally studies the effects of the following three types of enhanced PCM condensers on the system performance: (1) copper mesh enhanced PCM with helically coiled copper tube branches and large refrigerant distribution headers (CMPHX), (2) graphite matrix enhanced PCM with straight copper tube branches and small headers (GMPHX1), and (3) graphite matrix enhanced PCM with straight copper tube branches and large headers (GMPHX2). Results show that this system operates properly and effectively during both VCC and PCM regeneration operations. The system can provide four hours of continuous cooling, and the PCM can be fully regenerated after 7.4 hours by thermosyphon operation. The comparisons of three PCM condensers indicate that the system with GMPHX2 performs the best with the average VCC COP of 4.7. The VCC system with CMPHX has an average COP of 4.2, and GMPHX1 has an average COP of 3.1. GMPHX2 has the best heat transfer enhancement with an overall heat transfer coefficient of 632.1 W∙m-2∙K-1, which is more than twice of GMPHX1 and five times of CMPHX. Moreover, GMPHX2 can achieve more uniform refrigerant flows and PCM temperature distributions than GMPHX1. This leads to the higher utilization ratio of PCM latent heat. CMPHX is the second best but needs larger heat transfer surface area and inner volume as well as more refrigerant charge. In conclusion, the system design with GMPHX2 is recommended due to its small refrigerant charge, high VCC COP, and the use of good heat transfer enhancement material.

Qiao, Yiyuan↗

A Sub-grid Model for an Array of Immersed Cylinders in Coarse-grid Multiphase Flow Simulations of a Carbon Capture Device

A post-combustion carbon-capture system utilizing a bubbling fluidized bed of sorbent particles is currently being developed as a part of the Carbon Capture and Simulation Initiative (CCSI) efforts. Adsorption of carbon dioxide (CO2) by these amine based sorbent particles is exothermic and arrays of immersed cylindrical heat transfer tubes are often utilized to maintain the lower temperatures favorable for CO2 capture. In multiphase computational fluid dynamics (CFD) simulations of the full-scale devices, which can be up to 10 m in size, approximately 103 cells are required in each dimension to accurately resolve the cylindrical tubes, which are only a few centimeters in diameter. Since the tubes cannot be resolved explicitly in CFD simulations, alternate methods to account for the influence of these immersed objects need to be developed.

Sarkar, Avik↗

Development and Experimental Evaluation of Passive Fuel Cell Thermal Control

To provide uniform cooling for a fuel cell stack, a cooling plate concept was evaluated. This concept utilized thin cooling plates to extract heat from the interior of a fuel cell stack and move this heat to a cooling manifold where it can be transferred to an external cooling fluid. The advantages of this cooling approach include a reduced number of ancillary components and the ability to directly utilize an external cooling fluid loop for cooling the fuel cell stack. A number of different types of cooling plates and manifolds were developed. The cooling plates consisted of two main types; a plate based on thermopyrolytic graphite (TPG) and a planar (or flat plate) heat pipe. The plates, along with solid metal control samples, were tested for both thermal and electrical conductivity. To transfer heat from the cooling plates to the cooling fluid, a number of manifold designs utilizing various materials were devised, constructed, and tested. A key aspect of the manifold was that it had to be electrically nonconductive so it would not short out the fuel cell stack during operation. Different manifold and cooling plate configurations were tested in a vacuum chamber to minimize convective heat losses. Cooling plates were placed in the grooves within the manifolds and heated with surface-mounted electric pad heaters. The plate temperature and its thermal distribution were recorded for all tested combinations of manifold cooling flow rates and heater power loads. This testing simulated the performance of the cooling plates and manifold within an operational fuel cell stack. Different types of control valves and control schemes were tested and evaluated based on their ability to maintain a constant temperature of the cooling plates. The control valves regulated the cooling fluid flow through the manifold, thereby controlling the heat flow to the cooling fluid. Through this work, a cooling plate and manifold system was developed that could maintain the cooling plates within a minimal temperature band with negligible thermal gradients over power profiles that would be experienced within an operating fuel cell stack.

Fuel Cells↗

Klickitat Valley Health Central Utility Plant Modernization

This project replaced legacy heating and cooling equipment at Klickitat Valley Health (KVH), a rural hospital in Goldendale, Washington. Work included constructing a new chiller building, installing modern hydronic piping systems, replacing the main Emergency Department air handler (Air Handlining Unit (AHU-1)), upgrading electrical systems, and converting the Emergency Department wing from electric reheat to hydronic heating and cooling. Commissioning, testing, adjusting, and balancing were completed under this grant. These upgrades improve energy efficiency, operational resilience, and system reliability while preparing the campus for future electrification and renewable energy integration. They also support growth in healthcare services for a rural population. The project directly reduces energy costs and provides a foundation for future decarbonization measures, including a FEMA-funded microgrid and a large-scale ground source heat pump (GSHP) project. These follow-on initiatives would not have been possible without the hydronic backbone built through this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phenomena Identification and Ranking Table (PIRT) for heat pipes

Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in heat pipes, including capillary, phase change, turbulence, and compressibility effects, there are high uncertainties in the predictability of their operational regimes and performance. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. Additional analyses and discussion are provided for phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics. The discussions included the recognizing challenges and proposing future research directions for both modeling and simulation and experimental efforts. Additionally, the report addresses phenomena with medium importance and low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geyser boiling, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. In conclusion, this comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Comparative thermal analysis of alternate Cryogenic Fluid Management Experiment (CFME) configurations

The Cryogenic Fluid Management Experiment (CFME) was analyzed to assess the feasibility and advisability of deleting the vapor cooled shield (VCS) from the baseline CFME insulation and pressure control system. Two alternate concepts of CFME insulation and pressure control, neither of which incorporated the VCS, were investigated. The first concept employed a thermodynamic vent system (TVS) to throttle the flow through an internal wall mounted heat exchanger (HX) within the pressure vessel to decrease boiloff and pressure rise rate, while the second concept utilized a TVS without an internal heat exchanger. Only the first concept was viable. Its performance was assessed for a seven day mission and found to be satisfactory. It was also concluded that VCS development costs would be greater than for an internal HX installation. Based upon the above comparisons, the HX was recommended as a replacement for the VCS.

Merino, F.↗

Heat Transfer Efficiency in Various Prandtl Number Turbulent Flows using DNS approach

Convective heat transfer in turbulent flows utilized in many nuclear reactor designs with various coolants. While the traditional light water reactors (LWR) rely on water coolant, some advanced next-generation designs propose to use gas, molten salt, liquid metal coolants. Due to large presence of LWRs, most of the convective heat transfer correlations are focused on fluids with properties similar to water. However, some of the next-generation reactor designs cannot directly apply those correlations to advanced coolants, such as liquid metal, which has very low Prandtl number. Direct Numerical Simulation (DNS) is one of the promising approaches to study the details of fluid flow and heat transfer using first principles. The advances of high performance computing (HPC) in recent years made it possible to apply DNS to a wide variety of flow conditions. Kim and Moin studied heat transfer in fully developed turbulent channel flow using DNS. Kawamura et al. investigated the turbulent heat transfer in channel flow with low to medium-high Prandtl number fluid (ranging between 0.025 and 5.0). They take Reynolds number effects into consideration as well. However, most of these studies focus on medium and high Prandtl number. Low Prandtl number flow (like liquid metal) DNS studies are very limited. In the presented research the effect of low Prandtl number is studied in the turbulent channel flow. The second-order accurate spatial and time discretization is used for the flow solver in the presented work. The instantaneous velocity and temperature fields are visualized in the simulation. The effect of Prandtl number on the heat transfer is investigated by comparing different turbulent flow cases. In the same hydrodynamic conditions, the heat conduction enhances as the Prandtl number decreases in the low Prandtl number range. The behavior of the thermal boundary layer follows the empirical correlation. As the Prandtl number decreases, the conductive sublayer region becomes wider, where is out of the range of the empirical correlation. In the future work, we plan to estimate the Nusselt number as well to compare the total heat transfer rate with respect to different Prandtl number flow, especially the very low Prandtl number cases.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Phenomena Identification and Ranking Table (PIRT) for Heat Pipes

This Phenomena Identification and Ranking Table (PIRT) report provides an evaluation of key phenomena affecting the performance and operational regimes of heat pipes, particularly in the context of heat pipe microreactors (HPMRs). Heat pipes are advanced passive thermal management devices that utilize phase change and capillary action to achieve efficient heat transfer. However, due to the complexity of the phenomena coupled in the heat pipe, including phase change, turbulent transition, and compressibility effects, among others, there is high uncertainty in identifying and ranking the important phenomena affecting the operation of heat pipes and the current knowledge for their modeling and simulation and experimental measurements and instrumentation. This PIRT exercise, conducted as a collaborative effort involving the Department of Energy (DOE) Microreactor Program (MRP), the Nuclear Regulatory Commission (NRC), and university partners systematically identifies, reviews, and prioritizes critical phenomena affecting the operation of heat pipes based on their importance and knowledge levels. The report analyzes phenomena with high importance and low knowledge, such as wick de-wetting, critical heat flux, contact angles, and pressure dynamics, discussing challenges and future research directions for improving their modeling and simulation and experimental measurements. Additionally, the report addresses phenomena with low knowledge that could impact heat pipe operation during non-normal or transient operation, including frozen startup, laminar to turbulent transition, geysering, wick priming, underfilling conditions, surface roughness of the wick, NCGs trapped in the wick, and the timescales of startup and shutdown. This comprehensive evaluation serves as a valuable resource for guiding future research and development efforts, supporting the successful integration of heat pipes into critical applications such as nuclear reactors, and contributing to the advancement of heat pipe technologies in safety-critical industries.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Appalachian Basin Play Fairway Analysis: Revised 2016 Combined Risk Factor Analysis

This submission contains information used to compute the combined risk factors for deep geothermal energy opportunities in the Appalachian Basin, in the context of a the Play Fairway Analysis project. The risk factors are sedimentary rock reservoir quality, thermal resource quality, potential for induced seismicity, and utilization for direct-use heating of neighborhoods. The methods used to combine the risk factors included taking the average, the geometric mean, and the minimum of the four risk factors. Combined risk maps are provided for three different sedimentary rock reservoir metrics. Combined risk maps are also provided for the three geologic risk factors alone (thermal, reservoir, and seismic), and for the three risk factors that exclude reservoir quality (utilization, seismicity, and thermal qualities). The 2015 data submission should be visited to obtain associated shapefiles, which include: 1) definition of the High and Medium priority play fairways (Inner_Fairway, and Outer_Fairway), 2) definition of the US Census Places (usCensusPlaces), 3) places (cities) of interest in the region (Places_of_Interest) identified as geothermal play fairways, 4) the point centers of the raster cells (Raster_Center_Locations), and 5) locations of industries and special-use communities (e.g., colleges and military bases) identified as low temperature heat users (Industries). The 2015 submission also includes: 1) a methodology memo that explains how the risk factors were combined (GPFA-AB_combining_risk_factors.pdf), 2) the earthquake-based seismic risk map, and 3) supporting information with details of the calculations or processing used in generating these data files. More details on each file are given in the spreadsheet "list_of_contents.xlsx" in the folder "Supporting_Information". Code used to calculate values is available at https://github.com/calvinwhealton/geothermal_pfa under the folder "combining_metrics". Note that the 2016 code is currently under the branch named "combining_metrics_2016" in the folder called "combining_metrics". This branch may be merged with the master branch in the future. Many files contained within this submission update and replace the indicated files contained in: Cornell University. (2015). Risk Factor Analysis in Low-Temperature Geothermal Play Fairway Analysis for the Appalachian Basin (GPFA-AB) [data set]. Retrieved from https://gdr.openei.org/submissions/622. doi:10.15121/1261942

15 GEOTHERMAL ENERGY↗

Driftless Area Initiative Biomass Energy Project

The Driftless Area Initiative Biomass Energy Project evaluated the potential for biomass energy production and utilization throughout the Driftless Region of Illinois, Iowa, Minnesota and Wisconsin. The research and demonstration aspect of the project specifically focused on biomass energy feedstock availability and production potential in the region, as well as utilization potential of biomass feedstocks for heat, electrical energy production, or combined heat and power operations. The Driftless Region was evaluated because the topography of the area offers more acres of marginal soils on steep slopes, wooded areas, and riparian corridors than the surrounding “Corn Belt”. These regional land characteristics were identified as potentially providing opportunity for biomass feedstock production that could compete with traditional agriculture commodity crops economically. The project researched establishment methods and costs for growing switchgrass on marginal agricultural lands to determine the economic and quantitative feasibility of switchgrass production for biomass energy purposes. The project was successful in identifying the best management and establishment practices for switchgrass in the Driftless Area, but also demonstrated that simple economic payback versus commodity crops could not be achieved at the time of the research. The project also analyzed the availability of woody biomass and production potential for growing woody biomass for large scale biomass energy production in the Driftless Area. Analysis determined that significant resources exist, but costs to harvest and deliver to the site were roughly 60% greater than that of natural gas at the time of the study. The project contributed significantly to identifying both production potential of biomass energy crops and existing feedstock availability in the Driftless Area. The project also analyzed the economic feasibility of dedicated energy crops in the Driftless Area. High commodity crop prices and land values coupled with low fossil fuel prices, particularly natural gas, hampered the likelihood of widespread production and/or utilization of for large scale heating or electrical generation at the time of the study.

09 BIOMASS FUELS↗

Assessment of U.S. Urban Surface Temperature Using GOES-16 and GOES-17 Data: Urban Heat Island and Temperature Inequality

Abstract This study utilizes hourly land surface temperature (LST) data from the Geostationary Operational Environmental Satellite (GOES) to analyze the seasonal and diurnal characteristics of surface urban heat island intensity (SUHII) across 120 largest U.S. cities and their surroundings. Distinct patterns emerge in the classification of seasonal daytime SUHII and nighttime SUHII. Specifically, the enhanced vegetation index (EVI) and albedo (ALB) play pivotal roles in influencing these temperature variations. The diurnal cycle of SUHII further reveals different trends, suggesting that climate conditions, urban and nonurban land covers, and anthropogenic activities during nighttime hours affect SUHII peaks. Exploring intracity LST dynamics, the study reveals a significant correlation between urban intensity (UI) and LST, with LST rising as UI increases. Notably, populations identified as more vulnerable by the social vulnerability index (SVI) are found in high UI regions. This results in discernible LST inequality, where the more vulnerable communities are under higher LST conditions, possibly leading to higher heat exposure. This comprehensive study accentuates the significance of tailoring city-specific climate change mitigation strategies, illuminating LST variations and their intertwined societal implications.

Environmental Sciences & Ecology↗

Thermal Energy Corporation Combined Heat and Power Project

To meet the planned heating and cooling load growth at the Texas Medical Center (TMC), Thermal Energy Corporation (TECO) implemented Phase 1 of a Master Plan to install an additional 32,000 tons of chilled water capacity, a 75,000 ton-hour (8.8 million gallon) Thermal Energy Storage (TES) tank, and a 48 MW Combined Heat and Power (CHP) system. The Department of Energy selected TMC for a $10 million grant award as part of the Financial Assistance Funding Opportunity Announcement, U.S. Department of Energy National Energy Technology, Recovery Act: Deployment of Combined Heat and Power (CHP) Systems, District Energy Systems, Waste Energy Recovery Systems, and Efficiency Industrial Equipment Funding Opportunity Number: DE-FOA-0000044 to support the installation of a new 48 MW CHP system at the TMC located just outside downtown Houston. As the largest medical center in the world, TMC is home to many of the nation's best hospitals, physicians, researchers, educational institutions, and health care providers. TMC provides care to approximately six million patients each year, and medical instruction to over 71,000 students. A medical center the size of TMC has enormous electricity and thermal energy demands to help it carry out its mission. Reliable, high-quality steam and chilled water are of utmost importance to the operations of its many facilities. For example, advanced medical equipment, laboratories, laundry facilities, space heating and cooling all rely on the generation of heat and power. As result of this project TECO provides this mission critical heating and cooling to TMC utilizing a system that is both energy-efficient and reliable since it provides the capability to run on power independent of the already strained regional electric grid. This allows the medical center to focus on its primary mission providing top quality medical care and instruction without worrying about excessive energy costs or the loss of heating and cooling due to the risk of power outages. TECO's operation is the largest Chilled Water District Energy System in the United States. The company used DOE's funding to help install a new high efficiency CHP system consisting of a Combustion Turbine and a Heat Recovery Steam Generator. This CHP installation was just part of a larger project undertaken by TECO to ensure that it can continue to meet TMC's growing needs. The complete efficiency overhaul that TECO undertook supported more than 1,000 direct and indirect jobs in manufacturing, engineering, and construction, with approximately 400 of those being jobs directly associated with construction of the combined heat and power plant. This showcase industrial scale CHP project, serving a critical component of the nation's healthcare infrastructure, directly and immediately supported the energy efficiency and job creation goals established by ARRA and DOE. It also provided an unsurpassed model of a district energy CHP application that can be replicated within other energy intensive applications in the industrial, institutional and commercial sectors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intestinal transport of hexoses in the rat following chronic heat exposure

The study examines intestinal transport of sugars (D-glucose and D-galactose) in vitro and assesses organ maintenance in chronically heat-exposed rats. The results suggest that the response of intestinal absorption to heat exposure in the rat involves changes in intestinal weight and in glucose utilization. Despite the reduction in total intestinal weight, the ability of intestinal tissue to transport hexose per unit weight remains stable. Differences in intestinal weight and glucose utilization between pair-fed and heat-exposed animals suggest that the intestinal response to chronic heat exposure is not solely a function of the amount of food consumed. Alterations of hexose transport appear to be related to altered glucose metabolism and not altered transport capacity.

Carpenter, M.↗

Breadboard CO2 and humidity control system

A regenerable CO2 and humidity control system is being developed for potential use on shuttle as an alternate to the baseline lithium hydroxide (LiOH)/condensing heat exchanger system. The system utilizes a sorbent material, designated HS-C, to adsorb CO2 and water vapor from the cabin atmosphere. The material is regenerated by exposing it to space vacuum. A half-size breadboard system, utilizing a flight representative HS-C canister, was designed, built, and performance tested to shuttle requirements for total CO2 and total humidity removal. The use of a new chemical matrix material allowed significant optimization of the system design by packing the HS-C chemical into the core of a heat exchanger which is manifolded to form two separate and distinct beds. Breadboard system performance was proven by parametric testing and simulated mission testing over the full range of shuttle crew sizes and metabolic loadings. Vacuum desorption testing demonstrated considerable savings in previously projected shuttle vacuum duct sizing.

Boehm, A. M.↗

Fabrication of glass-ceramics containing spin-chain compound SrCuO{sub 2} and its high thermal conductivity

High thermal conductivity materials are in great demand for heat-flow control and heat dissipation in electronic devices. In this study, we have produced a glass-ceramics that contains spin-chain compound SrCuO{sub 2} and have found that the glass-ceramics yields high thermal conductivity of ∼5 W K{sup −1} m{sup −1} even at room temperature. The glass-ceramics is fabricated through crystallization of inhomogeneous melt-quenched oxides made from SrCO{sub 3}, CuO, Li{sub 2}CO{sub 3}, Ga{sub 2}O{sub 3}, and Al{sub 2}O{sub 3}. Transmission electron microscopy and X-ray and electron diffraction reveal that SrCuO{sub 2} crystallites with a size of 100–200 nm are precipitated in the glass-ceramics. The highness of the thermal conductivity is attributable to two sources: one is elongation of phonon mean free path due to the crystallization of the inhomogeneous structure or structural ordering. The other is emergence of the heat carriers, spinons, in the SrCuO{sub 2}. This highly thermal conductive glass-ceramics is expected to be utilized as base materials for heat-flow control devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Proposed Revision of the Decay Heat Standard ANSI/ANS-5.1-2005

The ANSI/ANS-5.1 [1] standard on decay heat in light water reactors is one of the most widely used standards for reactor design and safety analysis. The standard was last revised and issued in 2005. The 2005 revision included several important accomplishments, including incorporation of ENDF/B-VI nuclear data in the development of correction factors implemented in the standard, and revisions to the 'simplified method.' The status of the 2005 ANS-5.1 standard has been summarized previously [2]. Future revisions of the standard under consideration, as proposed by the working group, were to (a) improve the neutron capture effect specification, (b) include contributions from actinides not already addressed by the standard, and (c) specify values for the total recoverable decay energy Q for major fissionable elements. These items are carried over from recommendations by Dickens et al. [3] during development of the 1994 revision. The current working group has also identified the representation of decay heat uncertainties as an area for improvement. This paper discusses recent development activities to further improve and extend the utility of the ANS-5.1 decay heat standard. These developments are in progress, and this paper summarizes the status of the activities. The proposed revisions discussed in this paper are being considered by the working group for adoption in the next publication of the standard.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of the integrated utilities concept to community-size developments

It is shown that the modular integrated utility systems (MIUS) concept (combining the utility services of electrical power, heating and cooling, water supply and waste water treatment, and solid waste management into a single local plant) can be applied to community-size developments with major benefits of energy (fossil fuels) savings, reduction in solid waste haul-off quantity, and reduction in fresh water demand. Compared to a conventional utilities system, MIUS energy and water savings are found to reach 38 and 17%, respectively. Effluent and solid waste load reduction attain 17 and 80%, respectively. These benefits are obtainable through use of commercially available hardware and at costs competitive with conventional utilities.

Redding, T. E.↗

Enhancement of automotive exhaust heat recovery by thermoelectric devices

In an effort to improve automobile fuel economy, an experimental study is undertaken to explore practical aspects of implementing thermoelectric devices for exhaust gas energy recovery. A highly instrumented apparatus consisting of a hot (exhaust gas) and a cold (coolant liquid) side rectangular ducts enclosing the thermoelectric elements has been built. Measurements of thermoelectric voltage output and flow and surface temperatures were acquired and analyzed to investigate the power generation and heat transfer properties of the apparatus. Effects of inserting aluminum wool packing material inside the hot side duct on augmentation of heat transfer from the gas stream to duct walls were studied. Data were collected for both the unpacked and packed cases to allow for detection of packing influence on flow and surface temperatures. Effects of gas and coolant inlet temperatures as well as gas flow rate on the thermoelectric power output were examined. The results indicate that thermoelectric power production is increased at higher gas inlet temperature or flow rate. However, thermoelectric power generation decreases with a higher coolant temperature as a consequence of the reduced hot-cold side temperature differential. For the hot-side duct, a large temperature gradient exists between the gas and solid surface temperature due to poor heat transfer through the gaseous medium. Adding the packing material inside the exhaust duct enhanced heat transfer and hence raised hot-side duct surface temperatures and thermoelectric power compared to the unpacked duct, particularly where the gas-to-surface temperature differential is highest. Therefore it is recommended that packing of exhaust duct becomes common practice in thermoelectric waste energy harvesting applications.

30 DIRECT ENERGY CONVERSION↗