Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “group testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Linkage Transformations in a Three-Dimensional Covalent Organic Framework for High-Capacity Adsorption of Perfluoroalkyl Substances

Despite their many advantages, covalent organic frameworks (COFs) built from three-dimensional monomers are synthetically difficult to functionalize. Herein, we provide a new synthetic approach to the functionalization of a three-dimensional covalent organic framework (COF-300) by using a series of solid-state linkage transformations. By reducing the imine linkages of the framework to amine linkages, we produced a more hydrolytically stable material and liberated a nucleophilic amino group, poised for further functionalization. We then treated the amine-linked COF with diverse electrophiles to generate a library of functionalized materials, which we tested for their ability to adsorb perfluoroalkyl substances (PFAS) from water. The framework functionalized with dimethylammonium groups, COF-300-dimethyl, adsorbed more than 250 mg of perfluorooctanoic acid (PFOA) per 1 g of COF, which represents an approximately 14,500-fold improvement over that of COF-300 and underscores the importance of electrostatic interactions to PFAS adsorption performance. In conclusion, this work provides a conceptually new approach to the design and synthesis of functional three-dimensional COFs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct Observations of Ion Densities at Functionalized Interfaces to Test Hypotheses Regarding the Origin of Specific Ion Effects

Interactions of anions with protonatable groups were investigated using X-ray fluorescence near total reflection (XFNTR) on floating monolayers at the surface of water. The number of ions attracted to the interfacial region, which XFNTR measures directly, is ion-specific as well as monolayer-specific. Our observation of the distinctly different behaviors of ClO 4 – and ReO 4 – , two ions with the same tetrahedral structure and almost the same sizes and hydration enthalpies, challenges current theories of ion specificity. Our observations are inconsistent with not only the Gouy–Chapman model (as expected) but also size-modified Poisson–Boltzmann theory and the “law of matching water affinity”. Furthermore, we suggest that factors other than ion size and ion–water interactions, including possibly ion–ion interactions and lateral ordering at the interface, must be considered to account for specific ion effects.

36 MATERIALS SCIENCE↗

Low altitude, one centimeter, space debris search at Lincoln Laboratory's (M.I.T.) experimental test system

The majority of work performed by the Lincoln Laboratory's Space Surveillance Group, at the request of NASA, to define the near-earth population of man-made debris is summarized. Electrooptical devices, each with a 1.2 deg FOV, were employed at the GEODSS facility in New Mexico. Details of the equipment calibration and alignment procedures are discussed, together with implementation of a synchronized time code for computer controlled videotaping of the imagery. Parallax and angular speed data served as bases for distinguishing between man-made debris and meteoroids. The best visibility was obtained in dawn and dusk twilight conditions at elevation ranges of 300-2000 km. Tables are provided of altitudinal density distribution of debris. It is noted that the program also yielded an extensive data base on meteoroid rates.

Taff, L. G.↗

Expanding Orbital Testing: NASA Small Spacecraft Technology Program

The presentation will support the Decadal Survey working group meeting slated for July 13 – 15, 2022. The Decadal Survey on Biological and Physical Sciences Research in Space 2023-2032 will review the state of knowledge in the current and emerging areas of space-related biological and physical sciences research and generate recommendations for a comprehensive vision and strategy for a decade of transformative science at the frontiers of biological and physical sciences research in space. The study report will help NASA define and align biological and physical sciences research to uniquely advance scientific knowledge, meet human and robotic exploration mission needs, and provide terrestrial benefits.

Elwood Agasid↗

A Study of the Compressive Strength of Stiffened Plywood Panels

The results of compression tests on 44 stiffened plywood panels are presented and correlated in groups for the three types of failure observed: column failure, failure by separation of plywood from stiffener, and crushing failure. The expanded program of military aircraft construction has made it necessary to seek substitute materials that can be used in aircraft in place of aluminum alloys. Wood is one of these substitute materials. The development of synthetic resins as bonding and impregnating agents has resulted in the production of plywood which is being used in stressed-skin structures for aircraft. The use of plywood in such structures necessitates that tests be performed. to determine allowable stress values for use in design, This report presents a preliminary analysis of the results of compression tests on 44 stiffened plywood panels made by the Universal Moulded Products Corporation. The tests were made in a testing machine of 1,200,000 pounds capacity in the NACA structures research laboratory.

Lundquist, Eugene E.↗

Rodent Habitat on ISS: Advances in Capability for Determining Spaceflight Effects on Mammalian Physiology

Rodent research is a valuable essential tool for advancing biomedical discoveries in life sciences on Earth and in space. The National Research Counsel's Decadal survey (1) emphasized the importance of expanding NASAs life sciences research to perform long duration, rodent experiments on the International Space Station (ISS). To accomplish this objective, new flight hardware, operations, and science capabilities were developed at NASA ARC to support commercial and government-sponsored research. The flight phases of two separate spaceflight missions (Rodent Research-1 and Rodent Research-2) have been completed and new capabilities are in development. The first flight experiments carrying 20 mice were launched on Sept 21, 2014 in an unmanned Dragon Capsule, SpaceX4; Rodent Research-1 was dedicated to achieving both NASA validation and CASIS science objectives, while Rodent Reesearch-2 extended the period on orbit to 60 days. Groundbased control groups (housed in flight hardware or standard cages) were maintained in environmental chambers at Kennedy Space Center. Crewmembers previously trained in animal handling transferred mice from the Transporter into Habitats under simultaneous veterinary supervision by video streaming and were deemed healthy. Health and behavior of all mice on the ISS was monitored by video feed on a daily basis, and post-flight quantitative analyses of behavior were performed. The 10 mice from RR-1 Validation (16wk old, female C57Bl6/J) ambulated freely and actively throughout the Habitat, relying heavily on their forelimbs for locomotion. The first on-orbit dissections of mice were performed successfully, and high quality RNA (RIN values>9) and liver enzyme activities were obtained, validating the quality of sample recovery. Post-flight sample analysis revealed that body weights of FLT animals did not differ from ground controls (GC) housed in the same hardware, or vivarium controls (VIV) housed in standard cages. Organ weights analyzed post-flight showed that there were no differences between FLT and GC groups in adrenal gland and spleen weights, whereas FLT thymus and liver weights exceeded those of GC. Minimal differences between the control groups (GC and VIV) were observed. In addition, Over 3,000 aliquots collected post-flight from the four groups of mice were deposited into the Ames Life Science Data Archives for the Biospecimen Sharing Program and Genelab project. New capabilities recently developed include DEXA scanning, grip strength tests and male mice. In conclusion, new capability for long duration rodent habitation of group-housed rodents was developed and includes in-flight sample collection, thus avoiding the complication of reentry. Results obtained to date reveal the possibility of striking differences between the effects of short duration vs. long duration spaceflight. This Rodent Research system enables achievement of both basic science and translational research objectives to advance human exploration of space.

Bone Loss↗

Risk-based System Upgrade Planning for AOT-IC [Capstone Project]

The Accelerator Operations and Technology Instrumentation and Controls Group (AOT IC) at the Los Alamos Neutron Science Center (LANSCE) has established a comprehensive risk-based system upgrade planning strategy which has been utilized as a tool to prioritize system upgrade projects for the past several years. A challenge with the current system is that the group often lacks the data to quantify the probability and impact of system failures, so the group often relies instead on qualitative risk assessments as well as evaluations of a potential upgrade project’s alignment with group strategy and vision to prioritize projects. A proposed framework to enable quantitative risk probability and impact assessments has been developed and tested on three pilot systems chosen to broadly represent the types and conditions of equipment used by the group. The proposed framework incorporates availability data gathered from the LANSCE control room logbooks and the LANSCE work control system, as well as a system health evaluation which is conducted from a variety of resources to assess the probability of equipment failure. The impact of system failure is viewed from the perspective of impact on mission and schedule, where spares status, system documentation status, and the functional distribution of deployed systems are used to quantify these impacts.

43 PARTICLE ACCELERATORS↗

Effects of continuous exposure to high gravity on gravity preference in rats.

Rats were chronically centrifuged in excess of 2.0 g for 6 or 12 mo. They were given four 24-hr gravity-preference tests in a spiral centrifuge in which they could adjust the gravity level imposed by locomoting inward or outward radially along a track. Chronically centrifuged rats (Group CC) spent as much time at 2.0 g as at 1.0 g while normally raised controls (Group NC) selecdonly 1.0 g. Group CC initially selected 2.0 g and a preference for 1.0 g developed over the four test sessions. These results suggest that hypergravity is not necessarily an aversive stimulus and that gravity preference may depend initially upon the reference level involved. The ultimate selection of 1.0 g by chronically centrifuged animals suggests that a preference for a familiar gravity environment is replaced by a preference for low-gravity stimuli.

Mccoy, D. F.↗

UPDATES FROM THE INVOLUTE WORKING GROUP

The HFIR, RHF, and FRM II reactors represent a particular class of Research and Test Reactors that provide some of the most intense and continuous neutron fluxes for science, industry, and medical applications. These high-performance reactors have achieved compact cores by operating with Highly Enriched Uranium fuel (HEU, 235U/U ≥ 20 wt. %) and utilizing fuel plates curved as an involute. Due to the proliferation risks, the international community aims to reduce or eliminate, when possible, the use of HEU fuel in civilian facilities by converting them to a Low-Enriched Uranium fuel (LEU, 235U/U < 20 wt. %). Conversion of these reactors without significantly compromising their performance or safety is a challenging endeavor that can tremendously benefit from advanced computational tools and thus, eliminate unnecessary conservatism to ensure sufficient thermal margins. Therefore, models are being developed using modern Computational Fluid Dynamics (CFD) and Computational Structural Mechanics (CSM) software to evaluate the steady-state safety margins of various LEU designs instead of being reliant on the more traditional, conservative methods. To gain the confidence and acceptance of high-fidelity modeling by the nuclear regulators, Argonne National Laboratory (ANL) and the involute reactors have formed an informal scientific group, the Involute Working Group (IWG). The IWG facilitates inter-organizational collaboration on experimental benchmarking, code-to-code comparisons, and Verification and Validation (V&V). This paper describes some of the recent IWG efforts in validating software against the existing experimental data, as well as code-to-code comparisons of different software used by the IWG members.

Bergeron, Aurelien↗

Test chips for custom ICs - Six kinds of test structures

Microelectronic test chips contain a number of test structures that are used for a variety of purposes in fabricating integrated circuits. For convenience, their use is divided into six groups: layout-rule evaluating, process-parameter extraction, device-parameter extraction, circuit-parameter extraction, initial-fabrication failure analysis, and reliability failure analysis. A given test structure can be used to gather information in a number of these groups. Examples are given here of the kinds of parameters that can be obtained in each of these groups. A table is included summarizing various device failures common to bulk CMOS and indicating failure mechanisms appearing after wafer fabrication and after stress.

Buehler, M. G.↗

Construction and testing of a space ready rectenna

In Feb. 1993, the Solar Power Satellite (SPS) Working Group from ISAS, Japan will launch a sounding rocket into low earth orbit to perform two activities: collect scientific information on the high power microwave-ionosphere interaction, and demonstrate microwave power transmission in space at 2.45 GHz. The SPS Working Group announced an open invitation to international agencies willing to collaborate with the Microwave Energy Transmission in Space (METS) experiment in a number of categories. Under the sponsorship of the NASA's Lewis Research Center, the Center for Space Power located at Texas A&M University joined the experiment by producing a microwave rectifying receiving antenna (rectenna). The rectenna is a special type of receiving antenna with unique properties and characteristics. The rectenna's main purpose is to efficiently convert microwave power into DC power. The rectenna is an advanced component in microwave power beaming technology developed for 2.45 GHz. The state-of-the-art rectenna for this frequency consists of dipole antennas, filter circuits, and transmission lines etched on a thin layer of Kapton film. The format of the thin film rectenna is ideally suited for space applications. Thin film rectennas have a low specific mass of approximately 1 kg/kW. The main component of the rectenna is the rectifying diode. High conversion efficiencies (90 percent) in microwave to DC power are capable with special Schottky barrier diodes correctly located in the rectenna circuitry. The theory of operation of the 2.45 GHz rectenna is explained. Experimental test results on the METS rectenna are presented. The packaging of the rectenna is also discussed to meet space qualifications.

Brown, Alan M.↗

Variable Pressure - Scanning Electron Microscopy (VP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Miniature Variable Pressure - Scanning Electron Microscopy (MVP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Design and Testing of a One-Third Scale Soyuz TM Descent Module Spartan Conversion Project Super Loki Instrumentation

The 1992-1993 senior Aerospace Engineering Design class continued work on the post landing configurations for the Assured Crew Return Vehicle. The Assured Crew Return Vehicle will be permanently docked to the space station fulfilling NASA's commitment of Assured Crew Return Capability in the event of an accident or illness aboard the space station. The objective of the project was to give the Assured Crew Return Vehicle Project Office data to feed into their feasibility studies. Three design teams were given the task of developing models with dynamically and geometrically scaled characteristics. Groups one and two combined efforts to design a one-third scale model of the Russian Soyuz TM Descent Module, and an on-board flotation system. This model was designed to determine the flotation characteristics and test the effects of a rigid flotation and orientation system. Group three designed a portable water wave test facility to be located on campus. Because of additional funding from Thiokol Corporation, testing of the Soyuz model and flotation systems took place at the Offshore Technology Research Center. Universities Space Research Association has been studying the use of small expendable launch vehicles for missions which cost less than 200 million dollars. The Crusader2B. which consists of the original Spartan first and second stage with an additional Spartan second stage and the Minuteman III upper stage is being considered for this task. University of Central Florida project accomplishments include an analysis of launch techniques, a modeling technique to determine flight characteristics, and input into the redesign of an existing mobile rail launch platform.

Anderson, Loren A.↗

Detection and quantitation of right ventricular reversible perfusion defects by stress SPECT myocardial perfusion imaging: A proof-of-principle study

Background: In patients with right dominant coronary circulation, the right ventricular (RV) myocardium and the inferior region of the left ventricular (LV) myocardium share a common source of blood flow. We hypothesized that stress/rest SPECT myocardial perfusion imaging (MPI) could detect reversible perfusion defects in the RV in some patients with LV inferior wall perfusion abnormalities. Material and Methods: We identified 2 groups of patients with LV inferior wall perfusion defects (with or without defects in other regions of LV myocardium) from our database. Patients in group 1 (n = 17) had reversible perfusion defects in the RV free wall by visual analysis, while patients in group 2 (n = 17) did not. The images were processed with filtered back projection and, separately, with iterative reconstruction. The images were then re-processed using an automated quantitative software that is specifically designed to include the RV in the region of interest. Results: There were 76% men in group 1 and 94% in group 2 (P <0.05). The mean age was 65±20 in group 1 vs. 63±18 years in group 2 (P < 0.05). The stress type was exercise in 30% in group 1 and 35% in group 2, with the remaining patients studied with pharmacological stress testing (P = NS). The presence of RV reversible perfusion defects using filtered back projection was more evident in 13 patients (75%), while it was better seen with iterative reconstruction in 4 patients (25%). By automated analysis, the RV reversible perfusion defect size was 19 ± 14% of RV myocardium. Conclusion: This proof-of-principle study demonstrates that reversible RV perfusion defects suggestive of ischemia can be detected by SPECT myocardial perfusion imaging in some patients with LV inferior ischemia by visual analysis and can be quantitated by automated programs. Further studies on the diagnostic and prognostic relevance of assessing RV ischemia on SPECT MPI are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Molecularly targeted anti-cancer drugs inhibit the invasion and metastasis of hepatocellular carcinoma by regulating the expression of MMP and TIMP gene families

Highlights: • The multi-target drugs of liver cancer bringing new hope for advance HCC patients. • Sorafenib, regorafenib, and lenvatinib have inhibitory effect on the metastasis and invasion. • They can down-regulate the expression of MMPs and up-regulate the TIMPs level. To investigate the effect of multi-kinase kinase inhibitors (sorafenib; regorafenib; lenvatinib) on the invasion and metastasis of human hepatocellular carcinoma (HCC) cells, and the outcome of this effect on the expression of matrix metalloproteinases (MMPs) and tissue inhibitors of MMPs (TIMPs), yet unclarified. Cells were subjected to four different treatments: blank control group, sorafenib (10 μmol/L) treatment group, regorafenib (20 mmol/L) treatment group, and lenvatinib (4 μmol/L) treatment group. Anti-invasion and anti-metastasis effects were tested using the wound-healing assay and transwell invasion assay. Real-time PCR and Western blot analyses were used to determine the impact of sorafenib, regorafenib, and lenvatinib on the gene expression of MMPs and TIMPs in the two HCC lines (Hep3B and SMMC-7721). Results from the wound-healing and transwell invasion assays showed the three tested anti-cancer drugs to have a significant inhibitory effect on the metastasis and invasion of HCC cells. Real-time PCR and western blot analyses revealed that sorafenib down-regulated the expressions of MMP-7,10,16 and up-regulated those of TIMP-1,3,4, regorafenib down-regulated the expression of MMP-1 and up-regulated TIMP-3 gene expression, and lenvatinib down-regulated the expressions of MMP-1,2,7,9,10,16 and up-regulated those of TIMP-1,3,4. However, these three targeted anti-cancer drugs seem to have no significant regulatory effect on the expressions of other MMPs and TIMPs family genes. In conclusion, sorafenib, regorafenib, and lenvatinib inhibit the invasion and metastasis of HCC cells by regulating MMPs/TIMPs expression levels.

60 APPLIED LIFE SCIENCES↗