Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

High-pressure liquid-monopropellant strand combustion.

Examination of the influence of dissolved gases on the state of the liquid surface during high-pressure liquid-monopropellant combustion through the use of a strand burning experiment. Liquid surface temperatures were measured, using fine-wire thermocouples, during the strand combustion of ethyl nitrate, normal propyl nitrate, and propylene glycol dinitrate at pressures up to 81 atm. These measurements were compared with the predictions of a variable-property gas-phase analysis assuming an infinite activation energy for the decomposition reaction. The state of the liquid surface was estimated using a conventional low-pressure phase equilibrium model, as well as a high-pressure version that considered the presence of dissolved combustion-product gases in the liquid phase. The high-pressure model was found to give a superior prediction of measured liquid surface temperatures. Computed total pressures required for the surface to reach its critical mixing point during strand combustion were found to be in the range from 2.15 to 4.62 times the critical pressure of the pure propellant. Computed dissolved gas concentrations at the liquid surface were in the range from 35 to 50% near the critical combustion condition.

Faeth, G. M.↗

Development and Validation of Scale Nuclear Analysis Methods for High Temperature Gas-Cooled Reactors

In support of the U.S. Nuclear Regulatory Commission, ORNL is updating the nuclear analysis methods and data in the SCALE code system to support modeling of HTGRs. Development activities include methods used for reactor physics, criticality safety, and radiation shielding. This paper focuses on the nuclear methods in support of reactor physics, which primarily include lattice physics for cross-section processing of both prismatic and pebble-bed designs, Monte Carlo depletion methods and efficiency improvements for double heterogeneous fuels, and validation against relevant experiments. These methods enhancements are being validated using available experimental data from the HTTR and HTR-10 startup and initial criticality experiments. Results obtained with three-dimensional Monte Carlo models of the HTTR initial core critical configurations with SCALE6/KENO show excellent agreement between the continuous energy and multigroup methods and the results are consistent with results obtained by others. A three-dimensional multigroup Monte Carlo model for the initial critical core of the HTR-10 has been developed with SCALE6/KENO based on the benchmark specifications included in the IRPhE Handbook. The core eigenvalue obtained with this model is in very good agreement with the corresponding value obtained with a consistent continuous energy MCNP5 core model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Variability of absorption heat pump efficiency for domestic water heating and space heating based on time-weighted bin analysis

Natural gas-driven absorption heat pumps are under renewed scrutiny as a viable technology for space conditioning and water heating for residential and commercial applications because of natural gas production trends, pricing, and the speculation that it might be a “bridge fuel” in the global transition towards energy sustainability. Since any level of natural gas combustion contributes to atmospheric carbon dioxide accumulation, the merits of natural gas consuming absorption technology are re-examined in this paper from the point of view of expected efficiency throughout the United States using a time-weighted bin temperature analysis. Such analyses are necessary because equipment standards for rated performance is restricted to one set ambient condition, whereas in actual practice, the absorption heat pump (AHP) must perform over a considerably wider range of external conditions, where its efficiency may be vastly different from that at the rated condition. Quantification of variation in efficiency and system performance are imperative to address how to provide the desired utility with the least environmental impact. In this paper, we examine limiting features in absorption heat pumps and relate it to systemic performances in sixteen cities across all eight climate zones in the U.S, each containing fifteen bin temperatures. The results indicate that the true expectation of performance of an AHP is significantly less than what might be optimized for the rated condition. Statistical measures of the variation in water heating COPs show that for most cities, the COP at the rated conditions is outside the 95% Confidence Interval. Moreover, it is concluded that deployment of absorption heat pump water heaters (AHPWH) may be restricted geographically by outdoor temperature constraints.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Liquid rocket engine self-cooled combustion chambers

Self-cooled combustion chambers are chambers in which the chamber wall temperature is controlled by methods other than fluid flow within the chamber wall supplied from an external source. In such chambers, adiabatic wall temperature may be controlled by use of upstream fluid components such as the injector or a film-coolant ring, or by internal flow of self-contained materials; e.g. pyrolysis gas flow in charring ablators, and the flow of infiltrated liquid metals in porous matrices. Five types of self-cooled chambers are considered in this monograph. The name identifying the chamber is indicative of the method (mechanism) by which the chamber is cooled, as follows: ablative; radiation cooled; internally regenerative (Interegen); heat sink; adiabatic wall. Except for the Interegen and heat sink concepts, each chamber type is discussed separately. A separate and final section of the monograph deals with heat transfer to the chamber wall and treats Stanton number evaluation, film cooling, and film-coolant injection techniques, since these subjects are common to all chamber types. Techniques for analysis of gas film cooling and liquid film cooling are presented.

Source record↗

Magnesium production by the Pidgeon process involving dolomite calcination and MgO silicothermic reduction: Thermodynamic and environmental analyses

Thermochemical equilibrium calculations indicate the possibility of considerable fuel savings and CO{sub 2} emission avoidance in the three steps of the Pidgeon process: (a) calcination of dolomite; (b) production of ferrosilicon from quartz sand, coal, and iron oxide; (c) silicothermic reduction of calcined dolomite by ferrosilicon to magnesium. All three steps should benefit from application of concentrated solar energy as the source of high-temperature process heat, while the first two steps may be adapted to the coproduction of syngas. For the production of ferrosilicon, an experimental study was carried out by thermogravimetry as a model for a solar-driven process. The net reaction at 1823 K was shown to be represented by Fe{sub 2}O{sub 3} + 4SiO{sub 2} + 11C {yields} 2FeSi{sub s} + 10CO{sub g} + SiC{sub s} + SiO{sub g}, confirmed by gas chromatographic analysis of the evolved CO and by XRD identification of the solid products FeSi and SiC. This product mixture agrees with that predicted for the thermochemical equilibrium, but differs from that reported in the literature for the electric arc process.

01 COAL, LIGNITE, AND PEAT↗

Pulmonary function in microgravity

We report the successful collection of a large quantity of human resting pulmonary function data on the SLS-1 mission. Preliminary analysis suggests that cardiac stroke volumes are high on orbit, and that an adaptive reduction takes at least several days, and in fact may still be in progress after 9 days on orbit. It also suggests that pulmonary capillary blood volumes are high, and remain high on orbit, but that the pulmonary interstitium is not significantly impacted. The data further suggest that the known large gravitational gradients of lung function have only a modest influence on single breath tests such as the SBN washout. They account for only approximately 25% of the phase III slope of nitrogen, on vital capacity SBN washouts. These gradients are only a moderate source of the cardiogenic oscillations seen in argon (bolus gas) and nitrogen (resident gas), on such tests. They may have a greater role in generating the normal CO2 oscillations, as here the phase relationship to argon and nitrogen reverses in microgravity, at least at mid exhalation in those subjects studied to date. Microgravity may become a useful tool in establishing the nature of the non-gravitational mechanisms that can now be seen to play such a large part in the generation of intra-breath gradients and oscillations of expired gas concentration. Analysis of microgravity multibreath nitrogen washouts, single breath washouts from more physiological pre-inspiratory volumes, both using our existing SLS-1 data, and data from the upcoming D-2 and SLS-2 missions, should be very fruitful in this regard.(ABSTRACT TRUNCATED AT 250 WORDS).

manned↗

STUDYING THE WARM-HOT INTERGALACTIC MEDIUM IN EMISSION

We assess the possibility of detecting the warm-hot intergalactic medium in emission and characterizing its physical conditions and spatial distribution through spatially resolved X-ray spectroscopy, in the framework of the recently proposed DIOS, EDGE, Xenia, and ORIGIN missions, all of which are equipped with microcalorimeter-based detectors. For this purpose, we analyze a large set of mock emission spectra, extracted from a cosmological hydrodynamical simulation. These mock X-ray spectra are searched for emission features showing both the O VII K{alpha} triplet and O VIII Ly{alpha} line, which constitute a typical signature of the warm-hot gas. Our analysis shows that 1 Ms long exposures and energy resolution of 2.5 eV will allow us to detect about 400 such features per deg{sup 2} with a significance {>=}5{sigma} and reveals that these emission systems are typically associated with density {approx}100 above the mean. The temperature can be estimated from the line ratio with a precision of {approx}20%. The combined effect of contamination from other lines, variation in the level of the continuum, and degradation of the energy resolution reduces these estimates. Yet, with an energy resolution of 7 eV and all these effects taken into account, one still expects about 160 detections per deg{sup 2}. These line systems are sufficient for tracing the spatial distribution of the line-emitting gas, which constitute an additional information, independent from line statistics, to constrain the poorly known cosmic chemical enrichment history and the stellar feedback processes.

79 ASTRONOMY AND ASTROPHYSICS↗

Commissioning of Robotic Inspection and Automated Analysis System for Assay of Gas Diffusion Piping - 19500

Robotic, in-pipe, nondestructive assay (NDA) is a revolutionary and important means for measuring, analyzing, and reporting radioactive holdup deposits in enrichment piping. This innovation promises vast advantages for efficiency, safety, and cost savings. Payoff, however, lies in utilization much more than innovation. Crossing that threshold from a technical capability to an everyday tool occurs only after rigorous commissioning, adoption, and infusion. This must meet the highest standard, and there can be no compromise. Certification of a new NDA technology must meet the highest standards for quality, safety, and efficacy. Prior to this work, there was no precedent of procedure and method for certification of a robotic methodology for this purpose. The best of robotics had not certified NDA. The best of NDA had not certified robotics. Hence, a great deal of discovery, resourcefulness, and collaboration contributed to this success. This paper chronicles the first-of-kind chartering, co-development, testing, documentation, and site integration that certified this trailblazing in-pipe, robotic NDA. Commissioning had to demonstrate and certify end-to-end NDA automation from robot traversal to computer analysis to report generation of contaminated process piping at the Portsmouth, Ohio gaseous diffusion facility. This was a rigorous campaign of tests, evaluations, and documentation. Highlights included multiple tests in four elevated pipes exercised the gamut of NDA and robotic capabilities. Each of the four test pipes presented a unique loading of U-235. The tests demonstrated operations in both 30- inch and 42-inch diameter pipes with varying lengths and terminated by a variety of valves and fittings. Tests in a fifth pipe at floor level demonstrated deployment and applicability for pipes at this ground height and robot recognition of another fitting type. All operations, calibration, deployment, auto-reporting, and analysis were handled by Portsmouth site personnel. These tests concluded a series of component-level acceptance tests which certified all constituent technologies and operational features. Test metrics included comparison of reported to ground truth results and assessment of data quality from quality assurance and replicate measurement comparison. Beyond the radiometry associated with any NDA method, this unique commissioning path exercised and evaluated all the robotic features that are intrinsic to automation. These include odometry, geometric modeling, autonomy, remote launch and recovery, and end-to-end data flow. Each of these required verification and certification. These evaluations were first-of-kind for the decommissioning community, requiring innovation and resourcefulness in their own right. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tailoring Charge Reactivity Using In-Cylinder Generated Reformate for Gasoline Compression Ignition Strategies

In-cylinder reforming of injected fuel during a negative valve overlap (NVO) recompression period can be used to optimize main-cycle combustion phasing for low-load low-temperature gasoline combustion (LTGC). The objective of this work is to examine the effects of reformate composition on main-cycle engine performance. An alternate-fire sequence was used to generate a common exhaust temperature and composition boundary condition for a cycle-of-interest, with performance metrics measured for these custom cycles. NVO reformate was also separately collected using a dump valve apparatus and characterized by both gas chromatography and photoionization mass spectroscopy. To facilitate gas sample analysis, sampling experiments were conducted using a five-component gasoline surrogate (isooctane, n-heptane, ethanol, 1-hexene, and toluene) that matched the molecular composition, 50% boiling point, and ignition characteristics of the research gasoline. For the gasoline, it was found that an advance of the NVO start-of-injection (SOI) led to a corresponding advance in main-period combustion phasing as the combination of longer residence times and lower amounts of liquid spray piston impingement led to a greater degree of fuel decomposition. The effect was more pronounced as the fraction of total fuel injected in the NVO period increased. Main-period combustion phasing was also found to advance as the main-period fueling decreased. Slower kinetics for leaner mixtures were offset by a combination of increased bulk-gas temperature from higher charge specific heat ratios and increased fuel reactivity due to higher charge reformate fractions.

42 ENGINEERING↗

Core level excitation of simple gases

The ionization of simple gases by electron bombardment exhibits distinct resonances at electron energies slightly below the core level binding energies of the atomic constituents of the gas. A vacancy in an inner shell of the atom may recombine by a radiationless Auger process, thus leaving the molecule in a singly or higher ionized state. These ions are easily collected and the threshold resonances for excitation are evident in the second derivative of the ion yield plotted as a function of the energy of the electron beam. By using a mixture of gases, such as CO and CO2, it is possible to measure relative chemical shifts of the C and O 1s thresholds. In this case the C 1s threshold is 3.9 eV lower in CO than in CO2, and the O 1s threshold is 2.7 eV lower in CO than in CO2. The feasibility of constructing a simple analyzer based on this technique will be discussed to supplement conventional mass spectrometer analysis of gas composition.

Zhang, A.↗

Study of the VOC emissions from a municipal solid waste storage pilot-scale cell: Comparison with biogases from municipal waste landfill site

Highlights: > Follow-up of the emission of VOCs in a municipal waste pilot-scale cell during the acidogenesis and acetogenesis phases. > Study from the very start of waste storage leading to a better understanding of the decomposition/degradation of waste. > Comparison of the results obtained on the pilot-scale cell with those from 3 biogases coming from the same landfill site. > A methodology of characterization for the progression of the stabilization/maturation of waste is finally proposed. - Abstract: The emission of volatile organic compounds (VOCs) from municipal solid waste stored in a pilot-scale cell containing 6.4 tonnes of waste (storage facility which is left open during the first period (40 days) and then closed with recirculation of leachates during a second period (100 days)) was followed by dynamic sampling on activated carbon and analysed by GC-MS after solvent extraction. This was done in order to know the VOC emissions before the installation of a methanogenesis process for the entire waste mass. The results, expressed in reference to toluene, were exploited during the whole study on all the analyzable VOCs: alcohols, ketones and esters, alkanes, benzenic and cyclic compounds, chlorinated compounds, terpene, and organic sulphides. The results of this study on the pilot-scale cell are then compared with those concerning three biogases from a municipal waste landfill: biogas (1) coming from waste cells being filled or recently closed, biogas (2) from all the waste storage cells on site, and biogas (3) which is a residual gas from old storage cells without aspiration of the gas. The analysis of the results obtained revealed: (i) a high emission of VOCs, principally alcohols, ketones and esters during the acidogenesis; (ii) a decrease in the alkane content and an increase in the terpene content were observed in the VOCs emitted during the production of methane; (iii) the production of heavier alkanes and an increase in the average number of carbon atoms per molecule of alkane with the progression of the stabilisation/maturation process were also observed. Previous studies have concentrated almost on the analysis of biogases from landfills. Our research aimed at gaining a more complete understanding of the decomposition/degradation of municipal solid waste by measuring the VOCs emitted from the very start of the landfill process i.e. during the acidogenesis and acetogenesis phases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis and comparison of wall cooling schemes for advanced gas turbine applications

The relative performance of (1) counterflow film cooling, (2) parallel-flow film cooling, (3) convection cooling, (4) adiabatic film cooling, (5) transpiration cooling, and (6) full-coverage film cooling was investigated for heat loading conditions expected in future gas turbine engines. Assumed in the analysis were hot-gas conditions of 2200 K (3500 F) recovery temperature, 5 to 40 atmospheres total pressure, and 0.6 gas Mach number and a cooling air supply temperature of 811 K (1000 F). The first three cooling methods involve film cooling from slots. Counterflow and parallel flow describe the direction of convection cooling air along the inside surface of the wall relative to the main gas flow direction. The importance of utilizing the heat sink available in the coolant for convection cooling prior to film injection is illustrated.

Colladay, R. S.↗

Systematic error analysis in the absolute hydrogen gas jet polarimeter at RHIC

The Polarized Atomic Hydrogen Gas Jet Target polarimeter (HJET) is operated at the Relativistic Heavy Ion Collider (RHIC) since 2004 to measure the absolute polarization of each colliding proton beam. Polarimeter detectors and data acquisition were upgraded in 2015 to increase the solid angle, energy range, and to improve the energy and time resolution. These upgrades along with an improved beam intensity and polarization allowed us to greatly reduce the statistical and systematic errors for the proton polarization measurements in RHIC Runs 15 (E beam = 100 GeV) and 17 (255 GeV). For a typical 8 hour RHIC store, the measured proton beam average polarization was about P beam ~ 55 ± 2.0 stat ± 0.3 syst %. The elastic pp analyzing power, AN(t)~0.04, was determined with a precision of about |δA N (t)|~0.0002 in the momentum transfer squared range 0.001<-t<0.020 GeV 2 . In this paper we present a detailed systematic error analysis of the polarization measurements at HJET. Perspectives of using the HJET based absolute polarimeters in the future Electron Ion Collider (EIC) will be also discussed.

43 PARTICLE ACCELERATORS↗

Numerical analysis of micro-/nanoscale gas-film lubrication of sliding surface with complicated structure

It has been reported that the friction between a partially polished diamond-coated surface and a metal surface was drastically reduced to zero when they are slid at a few m/s. Since the sliding was noiseless, it seems that the diamond-coated surface was levitated over the counter surface and the sliding mechanism was the gas film lubrication. Recently, the mechanism of levitation of a slider with a micro/nanoscale surface structure on a rotating disk was theoretically clarified [S. Yonemura et al., Tribol. Lett., (2014), doi:10.1007/s11249-014-0368-2]. Probably, the partially polished diamond-coated surface may be levitated by high gas pressure generated by the micro/nanoscale surface structure on it. In this study, in order to verify our deduction, we performed numerical simulations of sliding of partially polished diamond-coated surface by reproducing its complicated surface structure using the data measured by an atomic force microscope (AFM). As a result, we obtained the lift force which is large enough to levitate the slider used in the experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gasbuggy, New Mexico, Natural Gas and Produced Water Sampling and Analysis Results for 2011

The U.S. Department of Energy (DOE) Office of Legacy Management conducted natural gas sampling for the Gasbuggy, New Mexico, site on June 7 and 8, 2011. Natural gas sampling consists of collecting both gas samples and samples of produced water from gas production wells. Water samples from gas production wells were analyzed for gamma-emitting radionuclides, gross alpha, gross beta, and tritium. Natural gas samples were analyzed for tritium and carbon-14. ALS Laboratory Group in Fort Collins, Colorado, analyzed water samples. Isotech Laboratories in Champaign, Illinois, analyzed natural gas samples.

54 ENVIRONMENTAL SCIENCES↗

Computing interface motion in compressible gas dynamics

An analysis is conducted of the coupling of Osher and Sethian's (1988) 'Hamilton-Jacobi' level set formulation of the equations of motion for propagating interfaces to a system of conservation laws for compressible gas dynamics, giving attention to both the conservative and nonconservative differencing of the level set function. The capabilities of the method are illustrated in view of the results of numerical convergence studies of the compressible Rayleigh-Taylor and Kelvin-Helmholtz instabilities for air-air and air-helium boundaries.

Mulder, W.↗

Implosion dynamics of triple-nozzle gas-puff z pinches on COBRA

Experiments on the 1-MA, 220-ns COBRA generator at Cornell University were conducted to provide detailed measurements of structured cylindrical gas-puff z pinches. In the experiments, a 7 cm diameter triple-nozzle gas valve assembly with concentric outer and inner annular nozzles and a central gas jet initialize the z-pinch load with various working gases, radial density profiles, and externally applied axial magnetic fields. Planar laser-induced fluorescence provides a measure of the initial neutral gas density of the load, while three-frame laser shearing interferometry and multi-frame extreme ultraviolet (XUV) cameras reveal the formation and propagation of a magneto-Rayleigh–Taylor (MRT) unstable shock layer. Implosion trajectories are compared to simple, experimentally informed models and found to be in good agreement. Differences in the structure of the accelerating plasma sheath and evolution of the MRT instability are observed for different gas species and axial magnetic field strengths, correlating with differences in pinch uniformity and x-ray emission. Here, the average instability growth is compared to linear MRT theory predictions using the instantaneous acceleration of the best-fit implosion models and characteristic instability wavelength, with the effective Atwood number and seed perturbation size as fit parameters. For high density argon center jets, ionization prior to the arrival of the imploding plasma sheath suggests a heating mechanism consistent with photoionization by XUV self-emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance characterization of a hydrogen catalytic heater.

This report describes the performance of a high efficiency, compact heater that uses the catalytic oxidation of hydrogen to provide heat to the GM Hydrogen Storage Demonstration System. The heater was designed to transfer up to 30 kW of heat from the catalytic reaction to a circulating heat transfer fluid. The fluid then transfers the heat to one or more of the four hydrogen storage modules that make up the Demonstration System to drive off the chemically bound hydrogen. The heater consists of three main parts: (1) the reactor, (2) the gas heat recuperator, and (3) oil and gas flow distribution manifolds. The reactor and recuperator are integrated, compact, finned-plate heat exchangers to maximize heat transfer efficiency and minimize mass and volume. Detailed, three-dimensional, multi-physics computational models were used to design and optimize the system. At full power the heater was able to catalytically combust a 10% hydrogen/air mixture flowing at over 80 cubic feet per minute and transfer 30 kW of heat to a 30 gallon per minute flow of oil over a temperature range from 100 C to 220 C. The total efficiency of the catalytic heater, defined as the heat transferred to the oil divided by the inlet hydrogen chemical energy, was characterized and methods for improvement were investigated.

08 HYDROGEN↗