Asymmetric twins in rhombohedral boron carbide

Superhard materials consisting of light elements have recently received considerable attention because of their ultrahigh specific strength for a wide range of applications as structural and functional materials. However, the failure mechanisms of these materials subjected to high stresses and dynamic loading remain to be poorly known. We report asymmetric twins in a complex compound, boron carbide (B{sub 4}C), characterized by spherical-aberration-corrected transmission electron microscopy. The atomic structure of boron-rich icosahedra at rhombohedral vertices and cross-linked carbon-rich atomic chains can be clearly visualized, which reveals unusual asymmetric twins with detectable strains along the twin interfaces. This study offers atomic insights into the structure of twins in a complex material and has important implications in understanding the planar defect-related failure of superhard materials under high stresses and shock loading.

36 MATERIALS SCIENCE↗

Strong degradation of polycarbonate and polystyrene by the CO 2 capture solvent diethyl sebacate

Here, we report on observations of strong degradation of a polycarbonate vessel by a solvent being considered for a CO 2 capture process, diethyl sebacate. This degradation led to failure of a polymeric hollow fiber membrane unit. Additional tests showed rapid degradation of polycarbonate safety glasses and polystyrene-based petri dishes by exposure to diethyl sebacate at ambient conditions. We also report on safe operations with diethyl sebacate in extensive experiments studying the corrosion of steel in CO 2 -pressurized reactors lined with PTFE and using PTFE gaskets. Used diethyl sebacate was also stored for long time periods in bottles made from low-density polyethylene bottles without physical deterioration. These observations indicate that care must be taken in development of new contactors and processes for CO 2 capture with diethyl sebacate and related solvents and in the choice of material for storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pilot performance in zero-visibility precision approach

The pilot's short-term decisions regarding performance assessment and failure monitoring is examined. The performance of airline pilots who flew simulated zero-visibility landing approaches is reported. Results indicate that the pilot's mode of participation in the control task has a strong effect on his workload, the induced workload being lowest when the pilot acts as a monitor during a coupled approach and highest when the pilot is an active element in the control loop. A marked increase in workload at altitudes below 500 ft. is documented at all participation modes; this increase is inversely related to distance-to-go. The participation mode is shown to have a dominant effect on failure-detection performance, with a failure in a monitored (coupled) axis being detected faster than a comparable failure in a manually-controlled axis. Touchdown performance is also documented. It is concluded that the conventional instrument panel and its associated displays are inadequate for zero-visibility operations in the final phases of the landing approach.

Ephrath, A. R.↗

DSN research and technology support

Continuing testing and refinement of the remote controlled, unattended automated pulsar observing station is noted, along with routine pulsar observations of 22 pulsars. Radar observations of geostationary satellite are discussed. Current status of the 400-kW X-band radar is reported along with routine automatic testing of the stability-reliability of the DSS 13 maser-receiver noise adding radiometer combination. A failure in the Faraday rotation receiving system is noted along with discussion in some detail of the activities of the high power transmitter maintenance facility. Continuation of receiver phase stability testing, specifically the effects of temperature on coaxial cables, is discussed and results reported. A demonstration at full power of the microwave power transmission facility is noted and routine support of the planetary radio astronomy experiment is discussed. Transmission of master clock synchronization signals to overseas DSN stations is also reported.

Jackson, E. B.↗

Translational Systems Pharmacology‐Based Predictive Assessment of Drug‐Induced Cardiomyopathy

Drug‐induced cardiomyopathy contributes to drug attrition. We compared two pipelines of predictive modeling: (1) applying elastic net (EN) to differentially expressed genes (DEGs) of drugs; (2) applying integer linear programming (ILP) to construct each drug's signaling pathway starting from its targets to downstream proteins, to transcription factors, and to its DEGs in human cardiomyocytes, and then subjecting the genes/proteins in the drugs' signaling networks to EN regression. We classified 31 drugs with availability of DEGs into 13 toxic and 18 nontoxic drugs based on a clinical cardiomyopathy incidence cutoff of 0.1%. The ILP‐augmented modeling increased prediction accuracy from 79% to 88% (sensitivity: 88%; specificity: 89%) under leave‐one‐out cross validation. The ILP‐constructed signaling networks of drugs were better predictors than DEGs. Per literature, the microRNAs that reportedly regulate expression of our six top predictors are of diagnostic value for natural heart failure or doxorubicin‐induced cardiomyopathy. This translational predictive modeling might uncover potential biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

Long-Term Outcomes of Vestibular Schwannomas Treated With Fractionated Stereotactic Radiotherapy: An Institutional Experience

Purpose: We assessed clinical outcome and long-term tumor control after fractionated stereotactic radiotherapy (FSRT) for unilateral schwannoma. Methods and Materials: Between 1995 and 2007, 496 patients were treated with fractionated stereotactic radiotherapy at Johns Hopkins Hospital (Baltimore, MD); 385 patients had radiologic follow-up that met the inclusion criteria. The primary endpoint was treatment failure. Secondary endpoints were radiologic progression and clinical outcome. Logistic regression analysis assessed the association of age, race, tumor side, sex, and pretreatment symptoms. Results: In 11 patients (3%) treatment failed, and they required salvage (microsurgical) treatment. Radiologic progression was observed in 116 patients (30.0%), including 35 patients (9%) in whom the treatment volume more than doubled during the follow-up period, although none required surgical resection. Tumors with baseline volumes of less than 1 cm{sup 3} were 18.02 times more likely to progress than those with tumor volumes of 1 cm{sup 3} or greater (odds ratio, 18.02; 95% confidence interval, 4.25-76.32). Treatment-induced neurologic morbidity included 8 patients (1.6%) with new facial weakness, 12 patients (2.8%) with new trigeminal paresthesias, 4 patients (0.9%) with hydrocephalus (1 communicating and 3 obstructive), and 2 patients (0.5%) with possibly radiation-induced neoplasia. Conclusions: Although the rate of treatment failure is low (3%), careful follow-up shows that radiologic progression occurs frequently. When reporting outcome, the 'no salvage surgery needed' and 'no additional treatment needed' criteria for treatment success need to be complemented by the radiologic data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns of Local-Regional Failure in Completely Resected Stage IIIA(N2) Non-Small Cell Lung Cancer Cases: Implications for Postoperative Radiation Therapy Clinical Target Volume Design

Purpose: To analyze patterns of local-regional failure (LRF) for completely resected stage IIIA(N2) non-small cell lung cancer (NSCLC) patients treated in our hospital and to propose a clinical target volume (CTV) for postoperative radiation therapy (PORT) in these patients. Methods and Materials: From 2005 to 2011, consecutive patients with pT1-3N2 NSCLC who underwent complete resection in our hospital but who did not receive PORT were identified. The patterns of first LRF were assessed and evaluated as to whether these areas would be encompassed by our proposed PORT CTV. Results: With a median follow-up of 24 months, 173 of 250 patients (69.2%) experienced disease recurrence. Of the 54 patients with LRF as the first event, 48 (89%) had recurrence within the proposed PORT CTV, and 6 (11%) had failures occurring both within and outside the proposed CTV (all of which occurred in patients with right-lung cancer). Ninety-three percent of failure sites (104 of 112) would have been contained within the proposed PORT CTV. For left-sided lung cancer, the most common lymph node station failure site was 4R, followed by 7, 4L, 6, 10L, and 5. For right-sided lung cancer, the most common site was station 2R, followed by 10R, 4R, and 7. Conclusions: LRF following complete surgery was an important and potentially preventable pattern of failure in stage IIIA(N2) patients. Ipsilateral superior mediastinal recurrences dominated for right-sided tumors, whereas left-sided tumors frequently involved the bilateral superior mediastinum. Most of the LRF sites would have been covered by the proposed PORT CTV. A prospective investigation of patterns of failure after PORT (following our proposed CTV delineation guideline) is presently underway and will be reported in a separate analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lysosomal integral membrane protein-2 as a phospholipid receptor revealed by biophysical and cellular studies

Lysosomal integral membrane protein-2 (LIMP-2/SCARB2) contributes to endosomal and lysosomal function. LIMP-2 deficiency is associated with neurological abnormalities and kidney failure and, as an acid glucocerebrosidase receptor, impacts Gaucher and Parkinson’s diseases. Here we report a crystal structure of a LIMP-2 luminal domain dimer with bound cholesterol and phosphatidylcholine. Binding of these lipids alters LIMP-2 from functioning as a glucocerebrosidase-binding monomer toward a dimeric state that preferentially binds anionic phosphatidylserine over neutral phosphatidylcholine. In cellular uptake experiments, LIMP-2 facilitates transport of phospholipids into murine fibroblasts, with a strong substrate preference for phosphatidylserine. Taken together, these biophysical and cellular studies define the structural basis and functional importance of a form of LIMP-2 for lipid trafficking. We propose a model whereby switching between monomeric and dimeric forms allows LIMP-2 to engage distinct binding partners, a mechanism that may be shared by SR-BI and CD36, scavenger receptor proteins highly homologous to LIMP-2.

59 BASIC BIOLOGICAL SCIENCES↗

A quantification of the effectiveness of EPID dosimetry and software-based plan verification systems in detecting incidents in radiotherapy

Purpose: Complex treatments in radiation therapy require robust verification in order to prevent errors that can adversely affect the patient. For this purpose, the authors estimate the effectiveness of detecting errors with a “defense in depth” system composed of electronic portal imaging device (EPID) based dosimetry and a software-based system composed of rules-based and Bayesian network verifications. Methods: The authors analyzed incidents with a high potential severity score, scored as a 3 or 4 on a 4 point scale, recorded in an in-house voluntary incident reporting system, collected from February 2012 to August 2014. The incidents were categorized into different failure modes. The detectability, defined as the number of incidents that are detectable divided total number of incidents, was calculated for each failure mode. Results: In total, 343 incidents were used in this study. Of the incidents 67% were related to photon external beam therapy (EBRT). The majority of the EBRT incidents were related to patient positioning and only a small number of these could be detected by EPID dosimetry when performed prior to treatment (6%). A large fraction could be detected by in vivo dosimetry performed during the first fraction (74%). Rules-based and Bayesian network verifications were found to be complimentary to EPID dosimetry, able to detect errors related to patient prescriptions and documentation, and errors unrelated to photon EBRT. Combining all of the verification steps together, 91% of all EBRT incidents could be detected. Conclusions: This study shows that the defense in depth system is potentially able to detect a large majority of incidents. The most effective EPID-based dosimetry verification is in vivo measurements during the first fraction and is complemented by rules-based and Bayesian network plan checking.

60 APPLIED LIFE SCIENCES↗

Cracking the failure of lithium batteries

Lithium batteries that use a solid electrolyte have the potential to improve safety and increase the amount of stored energy . This makes solid-state electrochemical cells a promising option for electric vehicles and wearable devices. However, nonuniform plating or stripping of lithium at the interface between an anode (negative electrode) and the electrolyte during charging and discharging leads to growth of detrimental lithium filaments (dendrites) that short-circuit the battery cell. This problem even occurs when the battery operates at small currents. The underlying mechanism of this failure is not well understood. On page 311 of this issue, Wang et al. (1) report that structural defects accumulate in the lithium metal anode under repeated charging and discharging at a small current. This is similar to mechanical fatigue that is observed over longer periods of intermittent straining of a material. Here, the observation could guide the design of lithium batteries with increased life span.

25 ENERGY STORAGE↗

Experimental Investigation of Concrete Fatigue in Axial Compression

The use of concrete in fatigue critical structures, such as wind turbine towers, has necessitated the replacement of simplistic (and therefore insufficient) fatigue design recommendations with more accurate and advanced fatigue models that can consider a greater complexity of stress states and materials. As the first part of a multistage test series, an experimental investigation was conducted to determine the fatigue life of concrete subjected to axial compressive fatigue loading, focusing on the relatively high-cycle fatigue domain. Here, a wide range of values for maximum stress levels and stress ratios were considered. The experimental results were compared against existing predictive models, and the most applicable model was identified. Concrete strain and stiffness behavior during fatigue loading were also investigated and reported. Based on the observed behavior, a hypothesis for identifying the impending occurrence of fatigue failure, based on the monotonic stress-strain curve, is examined.

17 WIND ENERGY↗

Impact of Measurement Error on Synchrophasor Applications

Phasor measurement units (PMUs), a type of synchrophasor, are powerful diagnostic tools that can help avert catastrophic failures in the power grid. Because of this, PMU measurement errors are particularly worrisome. This report examines the internal and external factors contributing to PMU phase angle and frequency measurement errors and gives a reasonable explanation for them. It also analyzes the impact of those measurement errors on several synchrophasor applications: event location detection, oscillation detection, islanding detection, and dynamic line rating. The primary finding is that dynamic line rating is more likely to be influenced by measurement error. Other findings include the possibility of reporting nonoscillatory activity as an oscillation as the result of error, failing to detect oscillations submerged by error, and the unlikely impact of error on event location and islanding detection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BWR Steam Dryer Alternating Stress Assessment Procedures

This report presents an overview of Boiling Water Reactor (BWR) steam dryer design; the fatigue cracking failures that occurred at the Quad Cities (QC) plants and their root causes; a history of BWR Extended Power Uprates (EPUs) in the USA; and a discussion of steam dryer modifications/replacements, alternating stress mechanisms on steam dryers, and structural integrity evaluations (static and alternating stress).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Microfluidic Liquid-Liquid Contactors

This report describes progress made on the microfluidic contactor. A model was developed to predict its failure, a surrogate chemical system was selected to demonstrate mass transfer, and an all-optical system has been invented and implemented to monitor carryover and flowrates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Facilitating Data Collection of Maintenance Events to Populate the Hydrogen Component Reliability Database (HyCReD)

The Hydrogen Component Reliability Database (HyCReD) is a collaborative project between the National Renewable Energy Laboratory, the University of Maryland, and hydrogen stakeholders to improve safety and reliability for hydrogen facilities by implementing component reliability data taxonomies that support hydrogen infrastructure failure rate analysis. The project aims to quantify failure rates of hydrogen components through high-quality data collection and analysis on root causes and maintenance needed. HyCReD provides a common database for cataloging hydrogen component failures which exists for reliability research in many other mature industries [2]. The database fills a gap for the hydrogen community by providing a scientifically rigorous approach to quantitative risk assessment (QRA), prognostic health management (PHM), and reliability-centered maintenance (RCM) analysis. High level results will be aggregated and anonymized to protect company sensitive information; detailed results will be used to help address issues of hydrogen components. These advanced analytics will support accelerated deployment of hydrogen infrastructure by enabling better: design and safety of projects (safety codes and standards development), infrastructure reliability and cost (component failure rates, maintenance protocols), and component R&D needs (robust supply chain). A key to a successful HyCReD implementation is facilitating the ease of reporting and data quality in the database that can be used for analysis. Maintenance data was a previously identified gap in initial efforts to populate and validate the database taxonomies [3]. Collection of maintenance data will be instrumental in identifying failure modes and rates, identifying incipient component failures or reduced performance, cataloging best practices for maintenance routines and methods for prognostic health management, and quantifying the risk and effect of different failure modes. Several key priorities are identified for streamlined data collection to achieve quality and detailed failure data: Applicability, Ease of Use, Accessibility, and Information Security. The HyCReD team has now begun deployment of the database to several companies and groups that have signed non-disclosure agreements to facilitate the data collection of failures in industry hydrogen refueling station infrastructure. This paper will provide an update into the process of HyCReD deployment including the development of a coding guide for facility personnel to reference and ensure data quality and consistency from one station to another as well as implementation of contextually dependent data fields of system taxonomy and formatted entries to provide ease of use. The goal is to communicate the lessons learned from the roll-out to technicians and engineers in the field, and the addition of need for high level of security to protect all stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of Navy radome failure problems

A survey of radome failure problems in military aircraft under actual operating conditions was conducted. The aircraft were operating from aircraft carriers in the Pacific Ocean. Critical problem areas were identified and a plan was developed for failure prevention. The development and application of repair kits for correcting the erosion damage are reported. It is stated that the rain erosion damage survey established a strong justification for qualification testing of all materials and designs which may have questionable life expectancy on the aircraft.

Tatnall, G. J.↗

Pocketing mechanics of SRM nozzle liner

A systems approach was adopted to study the pocketing phenomena on a solid rocket nozzle liner. The classical thermoelastic analysis was used to identify marginally strained regions on the composite liner erosion surface and at a depth coincident with the peak value of the across ply coefficient of thermal expansion. A failure criterion was introduced which included a thermal term and permitted failure assessment over the charred liner. The method was verified by satisfactory application to a reported related experiment. Liner pocketing mechanism was attributed to very localized material degradation caused during manufacturing process either by reduction of fiber strength and/or by concentration of resin volume fraction. Pocketing scenario over the degraged material was constructed with supporting formulation to predict size of fissures with respect to degraded material size and location in the liner and with burn time. Sensitivities of liner material parameters were determined to influence test programs designed to update mechanical data base of carbon cloth phenolic over the char temperature range.

Verderaime, V. S.↗

An Independent Evaluation of the FMEA/CIL Hazard Analysis Alternative Study

The present instruments of safety and reliability risk control for a majority of the National Aeronautics and Space Administration (NASA) programs/projects consist of Failure Mode and Effects Analysis (FMEA), Hazard Analysis (HA), Critical Items List (CIL), and Hazard Report (HR). This extensive analytical approach was introduced in the early 1970's and was implemented for the Space Shuttle Program by NHB 5300.4 (1D-2. Since the Challenger accident in 1986, the process has been expanded considerably and resulted in introduction of similar and/or duplicated activities in the safety/reliability risk analysis. A study initiated in 1995, to search for an alternative to the current FMEA/CIL Hazard Analysis methodology generated a proposed method on April 30, 1996. The objective of this Summer Faculty Study was to participate in and conduct an independent evaluation of the proposed alternative to simplify the present safety and reliability risk control procedure.

Ray, Paul S.↗