Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

X-ray tomography of extended objects: a comparison of data acquisition approaches

The penetration power of x-rays allows one to image large objects while their short wavelength allows for high spatial resolution. As a result, with synchrotron sources one has the potential to obtain tomographic images of centimeter-sized specimens with sub-micrometer pixel sizes. However, limitations on beam and detector size make it difficult to acquire such data of this sort in a single take, necessitating strategies for combining data from multiple regions. One strategy is to acquire a tiled set of local tomograms by rotating the specimen around each of the local tomogram center positions. Another strategy, sinogram oriented acquisition, involves the collection of projections at multiple offset positions from the rotation axis followed by data merging and reconstruction. We have carried out a simulation study to compare these two approaches in terms of radiation dose applied to the specimen, and reconstructed image quality. Local tomography acquisition involves an easier data alignment problem, and immediate viewing of subregions before the entire dataset has been acquired. Sinogram oriented acquisition involves a more difficult data assembly and alignment procedure, and it is more sensitive to accumulative registration error. Furthermore, sinogram oriented acquisition is more dose-efficient, it involves fewer translation motions of the object, and it avoids certain artifacts of local tomography.

47 OTHER INSTRUMENTATION↗

Cluster-based architecture for fault-tolerant quantum computation

We present a detailed description of an architecture for fault-tolerant quantum computation, which is based on the cluster model of encoded qubits. In this cluster-based architecture, concatenated computation is implemented in a quite different way from the usual circuit-based architecture where physical gates are recursively replaced by logical gates with error-correction gadgets. Instead, some relevant cluster states, say fundamental clusters, are recursively constructed through verification and postselection in advance for the higher-level one-way computation, which namely provides error-precorrection of gate operations. A suitable code such as the Steane seven-qubit code is adopted for transversal operations. This concatenated construction of verified fundamental clusters has a simple transversal structure of logical errors, and achieves a high noise threshold {approx}3% for computation by using appropriate verification procedures. Since the postselection is localized within each fundamental cluster with the help of deterministic bare controlled-Z gates without verification, divergence of resources is restrained, which reconciles postselection with scalability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Versioned distributed arrays for resilience in scientific applications: Global view resilience

Exascale studies project reliability challenges for future high-performance computing (HPC) systems. We propose the Global View Resilience (GVR) system, a library that enables applications to add resilience in a portable, application-controlled fashion using versioned distributed arrays. We describe GVR’s interfaces to distributed arrays, versioning, and cross-layer error recovery. Using several large applications (OpenMC, the preconditioned conjugate gradient solver PCG, ddcMD, and Chombo), we evaluate the programmer effort to add resilience. The required changes are small (<2% LOC), localized, and machine-independent, requiring no software architecture changes. We also measure the overhead of adding GVR versioning and show that generally overheads <2% are achieved. We conclude that GVR’s interfaces and implementation are flexible and portable and create a gentle-slope path to tolerate growing error rates in future systems.

97 MATHEMATICS AND COMPUTING↗

Molecular orbital projectors in non-empirical jmDFT recover exact conditions in transition-metal chemistry

Low-cost, non-empirical corrections to semi-local density functional theory are essential for accurately modeling transition-metal chemistry. Here, we demonstrate the judiciously modified density functional theory (jmDFT) approach with non-empirical U and J parameters obtained directly from frontier orbital energetics on a series of transition-metal complexes. We curate a set of nine representative Ti(III) and V(IV) d 1 transition-metal complexes and evaluate their flat-plane errors along the fractional spin and charge lines. We demonstrate that while jmDFT improves upon both DFT+U and semi-local DFT with the standard atomic orbital projectors (AOPs), it does so inefficiently. We rationalize these inefficiencies by quantifying hybridization in the relevant frontier orbitals. To overcome these limitations, we introduce a procedure for computing a molecular orbital projector (MOP) basis for use with jmDFT. We demonstrate this single set of d 1 MOPs to be suitable for nearly eliminating all energetic delocalization and static correlation errors. In all cases, MOP jmDFT outperforms AOP jmDFT, and it eliminates most flat-plane errors at non-empirical values. Unlike DFT+U or hybrid functionals, jmDFT nearly eliminates energetic delocalization and static correlation errors within a non-empirical framework.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Universal Spreading of Conditional Mutual Information in Noisy Random Circuits

For this work, we study the evolution of conditional mutual information (CMI) in generic open quantum systems, focusing on one-dimensional random circuits with interspersed local noise. Unlike in noiseless circuits, where CMI spreads linearly while being bounded by the light cone, we find that noisy random circuits with an error rate 𝑝 exhibit superlinear propagation of CMI, which diverges far beyond the light cone at a critical circuit depth 𝑡 𝑐 ∝ 𝑝 −1 . We demonstrate that the underlying mechanism for such rapid spreading is the combined effect of local noise and a scrambling unitary, which selectively removes short-range correlations while preserving long-range correlations. To analytically capture the dynamics of CMI in noisy random circuits, we introduce a coarse-graining method, and we validate our theoretical results through numerical simulations. Furthermore, we identify a universal scaling law governing the spreading of CMI.

decoherence↗

A procedure for the estimation of the numerical uncertainty of CFD calculations based on grid refinement studies

This paper offers a procedure for the estimation of the numerical uncertainty of any integral or local flow quantity as a result of a fluid flow computation; the procedure requires solutions on systematically refined grids. The error is estimated with power series expansions as a function of the typical cell size. These expansions, of which four types are used, are fitted to the data in the least-squares sense. The selection of the best error estimate is based on the standard deviation of the fits. The error estimate is converted into an uncertainty with a safety factor that depends on the observed order of grid convergence and on the standard deviation of the fit. For well-behaved data sets, i.e. monotonic convergence with the expected observed order of grid convergence and no scatter in the data, the method reduces to the well known Grid Convergence Index. Examples of application of the procedure are included. - Highlights: • Estimation of the numerical uncertainty of any integral or local flow quantity. • Least squares fits to power series expansions to handle noisy data. • Excellent results obtained for manufactured solutions. • Consistent results obtained for practical CFD calculations. • Reduces to the well known Grid Convergence Index for well-behaved data sets.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parameter estimation for binary neutron-star coalescences with realistic noise during the advanced LIGO era

Advanced ground-based gravitational-wave (GW) detectors begin operation imminently. Their intended goal is not only to make the first direct detection of GWs, but also to make inferences about the source systems. Binary neutron-star mergers are among the most promising sources. We investigate the performance of the parameter-estimation (PE) pipeline that will be used during the first observing run of the Advanced Laser Interferometer Gravitational-wave Observatory (aLIGO) in 2015: we concentrate on the ability to reconstruct the source location on the sky, but also consider the ability to measure masses and the distance. Accurate, rapid sky localization is necessary to alert electromagnetic (EM) observatories so that they can perform follow-up searches for counterpart transient events. We consider PE accuracy in the presence of non-stationary, non-Gaussian noise. We find that the character of the noise makes negligible difference to the PE performance at a given signal-to-noise ratio. The source luminosity distance can only be poorly constrained, since the median 90% (50%) credible interval scaled with respect to the true distance is 0.85 (0.38). However, the chirp mass is well measured. Our chirp-mass estimates are subject to systematic error because we used gravitational-waveform templates without component spin to carry out inference on signals with moderate spins, but the total error is typically less than 10{sup −3} M{sub ⊙}. The median 90% (50%) credible region for sky localization is ∼600 deg{sup 2} (∼150 deg{sup 2}), with 3% (30%) of detected events localized within 100 deg{sup 2}. Early aLIGO, with only two detectors, will have a sky-localization accuracy for binary neutron stars of hundreds of square degrees; this makes EM follow-up challenging, but not impossible.

79 ASTRONOMY AND ASTROPHYSICS↗

Improving the characterization of fusion in a MuSIC detector by spatial localization

Multi-Sampling Ionization Chambers (MuSIC) provide an efficient means of measuring nuclear reactions with low beam rates (< 10 6 pps). However, in comparison to thin-target measurements, prior measurements using MuSIC detectors all manifest fusion excitation functions with wide error bars in the energy dimension. This uncertainty limits the applicability of these devices in measuring near and sub-barrier fusion cross-sections. Key to overcoming this limitation is spatial localization of the fusion in the detector. By comparing the measured ionization in the MuSIC detector with accurate energy loss calculations the position of the fusion in the detector is determined. The analysis not only provides the desired improvement in energy resolution, but it also allows extraction of the atomic number of the evaporation residues following fusion. Furthermore, the effectiveness of this approach is demonstrated for 18 O+ 12 C measured with MuSIC@Indiana.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-P-21: Impact of MLC Position Errors On Simultaneous Integrated Boost Intensity-Modulated Radiotherapy for Nasopharyngeal Carcinoma

Purpose: To investigate the impact of MLC position errors on simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) for patients with nasopharyngeal carcinoma. Methods: To compare the dosimetric differences between the simulated plans and the clinical plans, ten patients with locally advanced NPC treated with SIB-IMRT were enrolled in this study. All plans were calculated with an inverse planning system (Pinnacle3, Philips Medical System{sub )}. Random errors −2mm to 2mm{sub )},shift errors{sub (} 2mm,1mm and 0.5mm) and systematic extension/ contraction errors (±2mm, ±1mm and ±0.5mm) of the MLC leaf position were introduced respectively into the original plans to create the simulated plans. Dosimetry factors were compared between the original and the simulated plans. Results: The dosimetric impact of the random and system shift errors of MLC position was insignificant within 2mm, the maximum changes in D95% of PGTV,PTV1,PTV2 were-0.92±0.51%,1.00±0.24% and 0.62±0.17%, the maximum changes in the D0.1cc of spinal cord and brainstem were 1.90±2.80% and −1.78±1.42%, the maximum changes in the Dmean of parotids were1.36±1.23% and −2.25±2.04%.However,the impact of MLC extension or contraction errors was found significant. For 2mm leaf extension errors, the average changes in D95% of PGTV,PTV1,PTV2 were 4.31±0.67%,4.29±0.65% and 4.79±0.82%, the averaged value of the D0.1cc to spinal cord and brainstem were increased by 7.39±5.25% and 6.32±2.28%,the averaged value of the mean dose to left and right parotid were increased by 12.75±2.02%,13.39±2.17% respectively. Conclusion: The dosimetric effect was insignificant for random MLC leaf position errors up to 2mm. There was a high sensitivity to dose distribution for MLC extension or contraction errors.We should pay attention to the anatomic changes in target organs and anatomical structures during the course,individual radiotherapy was recommended to ensure adaptive doses.

60 APPLIED LIFE SCIENCES↗

Deuterium and the Local Interstellar Medium: Properties for the Procyon and Capella Lines of Sight

We present Goddard High-Resolution Spectrograph observations of the interstellar H I and D I Ly-alpha lines and the Mg II and Fe II resonance lines formed along the lines of sight toward the nearby stars Procyon (3.5 pc, l = 214 deg, b = 13 deg) and Capella (12.5 pc, l = 163 deg, b = 5 deg). New observations of Capella were obtained at orbital phase 0.80, when the radial velocities of the intrinsic Ly-alpha emission lines of each star were nearly reversed from those of the previous observations at phase 0.26. Since the intrinsic Ly-alpha line of the Capella system (the 'continuum' against which the interstellar absorption is measured) has different shapes at phases 0.26 and 0.80, we can derive both the intrinsic stellar profiles and the interstellar absorption lines more precisely by jointly analyzing the two data sets. For the analysis of the Procyon line of sight, we first assumed that the intrinsic Ly-alpha line profile is a broadened solar profile, but this assumption does not lead to a good fit to the observed D I line profile for any value of D/H. We then assumed that (D/H)(sub LISM) = 1.6 x 10(exp -5), the same value as for the Capella line of sight, and we modified the broadened solar profile to achieve agreement between the simulated and observed line profiles. The resulting asymmetric intrinsic stellar line profile is consistent with the shapes of the scaled Mg II line profiles. We believe therefore that the Procyon data are consistent with (D/H)(sub LISM) = 1.6 x 10(exp -5), but the uncertainty in the intrinsic Ly-alpha emission-line profile does not permit us to conclude that the D/H ratio is constant in the local interstellar medium (LISM). The temperature and turbulence in the Procyon line of sight are T = 6900 +/- 80 (+/- 300 systematic error) K and zeta = 1.21 +/- 0.27 km/s. These properties are similar to those of Capella, except that the gas toward Procyon is divided into two velocity components separated by 2.6 km/s and the Procyon line of sight has a mean neutral hydrogen density that is a factor of 2.4 larger than that of the Capella line of sight. This suggests that the first 5.3 pc along the Capella line of sight lies within the local cloud and the remaining 7.2 pc lies in the hot gas surrounding the local cloud. We propose that n(H I) = 0.1065 +/- 0.0028 cm(exp -2) be adopted for the neutral hydrogen density within the local cloud and that zeta = 1.21 +/- 0.27 km/s be adopted for the nonthermal motions. The existence of different second velocity components toward the nearby stars Procyon and Sirius provides the first glimpse of a turbulent cloudlet boundary layer between the local cloud and the surrounding hot interstellar gas.

Linsky, Jeffrey L.↗

A phase-based interior penalty discontinuous Galerkin method for the Helmholtz equation with spatially varying wavenumber

This paper is concerned with an interior penalty discontinuous Galerkin (IPDG) method based on a flexible type of non-polynomial local approximation space for the Helmholtz equation with varying wavenumber. The local approximation space consists of multiple polynomial-modulated phase functions which can be chosen according to the phase information of the solution. We obtain some approximation properties for this space and a priori L 2 error estimates for the h-convergence of the IPDG method using duality argument. We also provide ample numerical examples to show that, building phase information into the local spaces often gives more accurate results comparing to using the standard polynomial spaces.

42 ENGINEERING↗

High Accuracy Transition Metal Effective Cores for the Many-Body Diffusion Monte Carlo Method

Practical applications of the real-space diffusion Monte Carlo (DMC) method require the removal of core electrons, where currently localization approximations of semilocal potentials are generally used in the projector. Accurate calculations of complex solids and large molecules demand minimizing the impact of approximated atomic cores. Prior works have shown that the errors from such approximations can be sizable in both finite and periodic systems. In this work, we show that a class of differential pseudopotentials, known as pseudo-Hamiltonians, can be constructed for the 3d transition metal atoms, entirely removing the need for any localization scheme in the DMC projector. As a proof of principle, we demonstrate the approach for the case of Co. In order to minimize errors in the pseudo-Hamiltonian at the many-body level, we generalize the recently proposed correlation-consistent pseudopotential generation scheme to successively close semilocal representations of the differential potentials. Our generation scheme successfully produces potentials tailored specifically for real space projector quantum Monte Carlo methods with low error at the many-body level, i.e., with many-body scattering properties very close to relativistic all-electron results. In particular, we show that the agreement with respect to atomic and molecular quantities reach chemical accuracy in many cases-on par with the most accurate semilocal pseudopotentials available. Further, our pseudo-Hamiltonian generation scheme utilizes standard quantum chemistry codes designed only to work with semilocal pseudopotentials, enabling straightforward generation of pseudo-Hamiltonians for additional elements in future works.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Covariant Quantum Error-Correcting Codes with Metrological Entanglement Advantage

Here, we show that a subset of the basis for the irreducible representations of a tensor-product SU(2) rotation forms a covariant approximate quantum error-correcting code with transversal U(1) logical gates. Generalizing previous work on “thermodynamic codes” to general local spin and different irreducible representations using only properties of the angular momentum algebra, we obtain bounds on the code inaccuracy under generic noise on any known 𝑑 sites, under independent and identically distributed noise, and under heralded 𝑑-local erasures. We demonstrate that this family of codes protects a probe state with quantum Fisher information surpassing the standard quantum limit when the sensing parameter couples to the generator of the U(1) logical gate.

quantum error correction↗

Detection of Local Cancer Recurrence After Stereotactic Ablative Radiation Therapy for Lung Cancer: Physician Performance Versus Radiomic Assessment

Purpose: Stereotactic ablative radiation therapy (SABR) is a guideline-specified treatment option for early-stage lung cancer. However, significant posttreatment fibrosis can occur and obfuscate the detection of local recurrence. The goal of this study was to assess physician ability to detect timely local recurrence and to compare physician performance with a radiomics tool. Methods and Materials: Posttreatment computed tomography (CT) scans (n=182) from 45 patients treated with SABR (15 with local recurrence matched to 30 with no local recurrence) were used to measure physician and radiomic performance in assessing response. Scans were individually scored by 3 thoracic radiation oncologists and 3 thoracic radiologists, all of whom were blinded to clinical outcomes. Radiomic features were extracted from the same images. Performances of the physician assessors and the radiomics signature were compared. Results: When taking into account all CT scans during the whole follow-up period, median sensitivity for physician assessment of local recurrence was 83% (range, 67%-100%), and specificity was 75% (range, 67%-87%), with only moderate interobserver agreement (κ = 0.54) and a median time to detection of recurrence of 15.5 months. When determining the early prediction of recurrence within <6 months after SABR, physicians assessed the majority of images as benign injury/no recurrence, with a mean error of 35%, false positive rate (FPR) of 1%, and false negative rate (FNR) of 99%. At the same time point, a radiomic signature consisting of 5 image-appearance features demonstrated excellent discrimination, with an area under the receiver operating characteristic curve of 0.85, classification error of 24%, FPR of 24%, and FNR of 23%. Conclusions: These results suggest that radiomics can detect early changes associated with local recurrence that are not typically considered by physicians. This decision support system could potentially allow for early salvage therapy of patients with local recurrence after SABR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Invariance of the bit error rate in the ancilla-assisted homodyne detection

We investigate the minimum achievable bit error rate of the discrimination of binary coherent states with the help of arbitrary ancillary states. We adopt homodyne measurement with a common phase of the local oscillator and classical feedforward control. After one ancillary state is measured, its outcome is referred to the preparation of the next ancillary state and the tuning of the next mixing with the signal. It is shown that the minimum bit error rate of the system is invariant under the following operations: feedforward control, deformations, and introduction of any ancillary state. We also discuss the possible generalization of the homodyne detection scheme.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonperturbative gravity corrections to bulk reconstruction

Abstract We introduce a new algebraic framework for understanding nonperturbative gravitational aspects of bulk reconstruction with a finite or infinite-dimensional boundary Hilbert space. We use relative entropy equivalence between bulk and boundary with an inclusion of nonperturbative gravitational errors, which give rise to approximate recovery. We utilize the privacy/correctability correspondence to prove that the reconstruction wedge, the intersection of all entanglement wedges in pure and mixed states, manifestly satisfies bulk reconstruction. We explicitly demonstrate that local operators in the reconstruction wedge of a given boundary region can be recovered in a state-independent way for arbitrarily large code subspaces, up to nonperturbative errors in G N . We further discuss state-dependent recovery beyond the reconstruction wedge and the use of the twirled Petz map as a universal recovery channel. We discuss our setup in the context of quantum islands and the information paradox.

97 MATHEMATICS AND COMPUTING↗

Minimum-error discrimination of entangled quantum states

Strategies to optimally discriminate between quantum states are critical in quantum technologies. We present an experimental demonstration of minimum-error discrimination between entangled states, encoded in the polarization of pairs of photons. Although the optimal measurement involves projection onto entangled states, we use a result of J. Walgate et al. [Phys. Rev. Lett. 85, 4972 (2000)] to design an optical implementation employing only local polarization measurements and feed-forward, which performs at the Helstrom bound. Our scheme can achieve perfect discrimination of orthogonal states and minimum-error discrimination of nonorthogonal states. Our experimental results show a definite advantage over schemes not using feed-forward.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recommendations for Using Noise Monitors to Estimate Noise Exposure During X-59 Community Tests

A low fidelity simulation approach is used to explore how to place and use noise monitors during X-59 QueSST community tests, where people’s annoyance to the noise produced by the X-59 aircraft will be gathered. Several recommendations are provided including: 1) the desired number of sparsely spaced noise monitor sites within the survey area, 2) whether to group and average measurements across multiple noise monitors located at a site, 3) what spacing should be used if grouped noise monitors are used, 4) an approach to mitigate ambient noise contamination at the measurement sites, 5) a method to combine empirical and predicted dose estimates to provide a single dose estimate for respondents, and 6) assessing how changes in turbulence intensity and array configuration affect dose uncertainty. To make these recommendations, the error that is expected when fitting contrived, smoothly varying sonic boom “reference exposure surfaces” is studied when a spatially sparse and scattered set of samples is used as responses for the fit. The reference exposure surfaces mimic the sonic boom exposure at ground level that might be expected in the X-59 survey area in the absence of atmospheric turbulence, ambient noise, and other localized effects. The spatial extent of these surfaces varies and is representative of the different survey area sizes that might be expected during future X-59 community overflight tests. These contrived reference surfaces are sampled, and those reference samples are then perturbed to mimic atmospheric turbulence, ambient noise and other localized effects that might affect noise monitor measurements within overflown communities. Two different surface fitting methods are investigated when fitting these perturbed samples to approximate the reference surface. The first method uses interpolation between the perturbed data at the scattered sites to compute the fit. The second method fits a polynomial surface model to the perturbed data using ordinary least squares regression analysis. For both fitting methods, the root mean square fit error is computed from the pointwise difference between the fit surface and the reference surface as the count and configuration of the sites is varied while also averaging the error across many different realizations of both the smooth variation of the reference exposure surface and the random, localized perturbations at the sample sites. Different site configurations are compared using this error statistic to make the recommendations noted above. Additionally, the two fitting approaches (interpolation vs linear regression) are compared based on the fit error observed in these simulations. These analyses, comparisons, and recommendations should inform future decisions on the noise monitor placement and the methods used to analyze the noise monitor data that is collected during X-59 community overflights.

sonic boom↗