Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “equivalence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Equivalence between Fermion-to-Qubit Mappings in two Spatial Dimensions

We argue that all locality-preserving mappings between fermionic observables and Pauli matrices on a two-dimensional lattice can be generated from the exact bosonization in Chen et al., whose gauge constraints project onto the subspace of the toric code with emergent fermions. Starting from the exact bosonization and applying Clifford finite-depth generalized local unitary transformation, we can achieve all possible fermion-to-qubit mappings (up to the re-pairing of Majorana fermions). In particular, we discover a new supercompact encoding using 1.25 qubits per fermion on the square lattice. We prove the existence of finite-depth quantum circuits to obtain fermion-to-qubit mappings with qubit-fermion ratios r = 1 + 1/2k for positive integers k, utilizing the trivialness of quantum cellular automata in two spatial dimensions. Also, we provide direct constructions of fermion-to-qubit mappings with ratios arbitrarily close to 1. When the ratio reaches 1, the fermion-to-qubit mapping reduces to the one-dimensional Jordan-Wigner transformation along a certain path in the two-dimensional lattice. Finally, we explicitly demonstrate that the Bravyi-Kitaev superfast simulation, the Verstraete-Cirac auxiliary method, Kitaev’s exactly solved model, the Majorana loop stabilizer codes, and the compact fermion-to-qubit mapping can all be obtained from the exact bosonization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Equivalent Performance in Three-Terminal and Four-Terminal Tandem Solar Cells

Tandem or multijunction solar cells are a promising method to circumvent the efficiency limit of single-junction solar cells, but there is ongoing debate over how best to interconnect the subcells in a tandem cell. In addition to four-terminal and two-terminal tandem cell architectures, a new three-terminal tandem cell architecture has recently been demonstrated, which features a standard two-terminal (front-back) circuit as well as an interdigitated back contact (IBC) circuit connected to the bottom cell. It has no middle contacts, and thus, maintains some of the simplicity of a two-terminal tandem. In this study, we measure four-terminal GaInP//Si and GaInP/GaAs//Si tandem cells in four-terminal and three-terminal configurations by connecting wires to mimic a three-terminal architecture. We demonstrate that both modes allow the same efficiencies exceeding 30% to be attained. Furthermore, we show that the IBC circuit not only collects excess power from the bottom cell, but that it can inject power into the bottom cell if it is current limiting the front-back circuit, enabling four-terminal performance in monolithic structures, regardless of which cell delivers less current.

14 SOLAR ENERGY↗

Are Capacity and Energy Loss Equivalent Metrics for Battery Aging Reporting?

Battery aging in research publications and manufacturer specification sheets for individual cells is commonly reported as capacity (Ah) versus cycle number. However, the key measured quantity in battery-powered devices is energy (Wh), which is derived from integrating capacity with voltage. In this work, we compare the rate of capacity and energy loss across a wide range of Li-ion single-cell cycling studies with different positive electrode chemistries, charge–discharge rates, and temperatures. We find that the relative rate of discharge energy loss varies with cycling conditions. For many cells cycled under moderate conditions, the rate of discharge energy fade is only slightly faster than the rate of discharge capacity fade. However, some cells demonstrated up to a 15% decline in cycle count when 80% energy retention rather than 80% capacity retention was used as the end-of-life metric. These results highlight the importance of reporting cell aging based on energy fade to avoid overestimating battery lifetime in full systems.

batteries↗

Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V{sub 100}{sup Prostate}>90%) and organ-at-risk dose sparing (V{sub 75}{sup Bladder}<1 cc, V{sub 75}{sup Rectum}<1 cc, V{sub 125}{sup Urethra}<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter patterns may decrease toxicity by avoidance of the critical structures near the penile bulb while still fulfilling the RTOG criteria.

61 RADIATION PROTECTION AND DOSIMETRY↗