This research report was prepared by the Building Science Corporation Building America Research Team as part of the Energy Efficient Housing Research Partnerships project. The project title is Hygric Redistribution in Insulated Assemblies. The exterior retrofit of frame assemblies can be risky when impermeable insulating sheathings of relatively low thermal resistance are used. For example, basic hygrothermal analysis demonstrates that removing the existing cladding and installing a board foam insulation with low vapor permeance (such as ½-in. foil faced rigid insulation) directly over the sheathing membrane under a replacement cladding (such as vinyl siding) is likely to cause moisture problems in cold climates. One such problem is known as a “cold sided vapor barrier.” Tens of thousands of such retrofit and renovation projects have been completed, however, without apparent problems. There is also a perception that when water is intentionally drained in a drainage cavity between exterior insulation and the existing structure following an energy retrofit, moisture-related durability concerns exist for the sheathing and wood structure. This experimental program includes a literature review of previous research, laboratory testing programs, and an analysis of full-scale test wall performance in the U.S. Department of Energy’s climate zone 4C.
The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.
The most common method of measuring air leakage is to perform single (or solo) blower door pressurization and/or depressurization test. In detached housing, the single blower door test measures leakage to the outside. In attached housing, however, this "solo" test method measures both air leakage to the outside and air leakage between adjacent units through common surfaces. Although minimizing leakage to neighboring units is highly recommended to avoid indoor air quality issues between units, reduce pressure differentials between units, and control stack effect, the energy benefits of air sealing can be significantly overpredicted if the solo air leakage number is used in the energy analysis. Guarded blower door testing is more appropriate for isolating and measuring leakage to the outside in attached housing. This method uses multiple blower doors to depressurize adjacent spaces to the same level as the unit being tested. Maintaining a neutral pressure across common walls, ceilings, and floors acts as a "guard" against air leakage between units. The resulting measured air leakage in the test unit is only air leakage to the outside. Although preferred for assessing energy impacts, the challenges of performing guarded testing can be daunting.
An analytical method is proposed for making an assessment of the severity of the response of PBX 9501 in structural response simulations. The approach is based on the coherent use of a strength model and a failure criterion. The strength model is based on a creep rupture function and an associated cumulative damage model. The material's residual strength at any time during a simulation of structural response is determined by taking into account both the actual stress history up to that time, and a hypothetical continuation of the applied stresses that are assumed to grow until material failure results. The residual strength is used by the failure criterion to define the region of safe (non-failed) material response. The Mohr-Coulomb failure criterion is chosen for its general applicability to materials with both cohesive and frictional strength. The combined use of the residual strength model and the failure criterion provides a quantitative method of assessing the severity of the response of PBX 9501 material in structural simulations: the proximity of any evolving, general state of stress to the failure surface (which shrinks due to the cumulative damage caused by the past stress history) can be calculated and used as a measure of margin to failure. The strength model has been calibrated to a broad range of uniaxial tension and compression tests, and a small set of creep tests, and is applicable to a broad range of loading conditions.
Abstract not provided
The U.S. Department of Energy Building America team Partnership for Home Innovation wrote a report on Phase 1 of the project that summarized a condition assessment of the homes and evaluated retrofit options within the constraints of the cooperative provided by GHI. Phase 2 was completed following monitoring in the 2013–2014 winter season; the results are summarized in this report. Phase 3 upgrades of heating equipment will be implemented in time for the 2014–2015 heating season and are not part of this report.
The Building America program has recognized that most of the current housing stock is in need of energy related retrofits. One of the best ways of reducing the space conditioning energy consumption is to improve the thermal performance of the enclosure by adding exterior board foam insulation. This report quantifies the amount of water that can become trapped in the drainage cavity of typical wall systems, and measures the effect of water trapped in the drainage cavity on the moisture content of the sheathing. This study also attempts to explain the discrepancy between hygrothermal simulations and field performance of low permeance, low R-value exterior insulation (e.g. ¾-in. foil faced polyisocyanurate) in cold climates.
The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.
Changing the air exchange rate of a home (the sum of the infiltration and mechanical ventilation airflow rates) affects the annual thermal conditioning energy. Large-scale changes to air exchange rates of the housing stock can significantly alter the residential sector’s energy consumption. However, the complexity of existing residential energy models is a barrier to the accurate quantification of the impact of policy changes on a state or national level.
When it comes to innovation in energy and building performance, one can expect leading-edge activity from the technology sector. As front-line innovators in design, materials science, and information management, developing and operating high-performance buildings is a natural extension of their core business. The energy choices made by technology companies have broad importance given their influence on society at large as well as the extent of their own energy footprint. Microsoft, for example, has approximately 250 facilities around the world (30 million square feet of floor area), with significant aggregate energy use of approximately 4 million kilowatt-hours per day (Figure 1).
The objective of this monitored field study was to identify near-term innovative façade technologies for solar control and daylighting with a goal of 20-40% energy use savings below Title 24 2013 in the 30-ft deep perimeter zone near vertical windows within cost and comfort constraints. The targeted market was new or existing commercial office buildings or buildings with similar patterns of use.
This technical brief investigates the potential benefits of air leakage testing in residential buildings covered by the commercial energy code and outlines an approach that could be applied based on building type, use, size and climate zone.
This technical brief investigates the potential benefits of air leakage testing in commercial buildings and outlines an approach that could be applied to energy codes based on building size and climate zone.
A water-resistive barrier (WRB) is a material installed on the exterior side of the sheathing to prevent water intrusion so that building components are not damaged by moisture. A membrane that can change its water vapor permeability between two states to control water vapor transport into and out of residential and commercial building wall systems is being developed. This simulation study assesses if this membrane used as a WRB reduces moisture levels and mold growth risk in exterior walls and building energy consumption. The developed membrane may require modifications to fully function as a WRB in contact with liquid water. Hygrothermal component simulations were conducted for different climate zones, different wall assemblies, different switching points and permeabilities to identify the most beneficial application cases and their required perm range and switching control. The study details the required simulation settings and suggests that the switchable membrane can reduce the water content in the sheathing and reduce the mold growth risk in the cavity in all climate zones. The effect on energy consumption of the switchable membrane is not significant. The study also includes recommendations on how to model the material characteristics of a switchable membrane and recommendations on practical applications for the switchable membrane.
The overall goal of this program is to develop a low NOx combustion system which enables a gas turbine combined cycle efficiency of > 65%. The proposed combustion system is a combination of three advanced technologies under development by the Recipient: advanced transition design, the Distributed Combustion System (DCS), and advanced head end. Of note is that the DCS and advanced transition were initially developed with DOE funding under previous Cooperative Agreements. The continued development of these designs has resulted in a proof of concept design which was successfully tested in the Recipient’s state-of-the-art high-pressure rig. The initial rig testing indicated a substantial benefit with respect to high firing temperature operation as well as low NOx operation for the advanced transition and the DCS. Even lower NOx and higher firing temperatures are possible with the addition of the advanced head end to the design. Potential hurdles to the combustion design have been identified, such as high pressure drop and acoustics. The goal of this program is to develop variations of this design which address these hurdles and create an optimized design for implementation into the Recipient’s new high efficiency gas turbine engine.
In the U.S., nuclear facilities operate at the intersection of legal regulatory requirements that serve as an operating license in a Government Owned/Contractor Operated (GOCO) partnership.
We use a stacking method to study the radial light profiles of luminous red galaxies (LRGs) at redshift $\sim 0.62$ and $\sim 0.25$, out to a radial range of 200 kpc. We do not find noticeable evolution of the profiles at the two redshifts. The LRG profiles appear to be well approximated by a single Sersic profile, although some excess light can be seen outside 60 kpc. We quantify the excess light by measuring the integrated flux and find that the excess is about 10% -- a non-dominant but still nonnegligible component.