Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

A balloon-borne high-resolution spectrometer for observations of gamma-ray emission from solar flares

The design, development, and balloon-flight verification of a payload for observations of gamma-ray emission from solar flares are reported. The payload incorporates a high-purity germanium semiconductor detector, standard NIM and CAMAC electronics modules, a thermally stabilized pressure housing, and regulated battery power supplies. The flight system is supported on the ground with interactive data-handling equipment comprised of similar electronics hardware. The modularity and flexibility of the payload, together with the resolution and stability obtained throughout a 30-hour flight, make it readily adaptable for high-sensitivity, long-duration balloon fight applications.

Crannell, C. J.↗

A cometary ion mass spectrometer

The development of flight suitable analyzer units for that part of the GIOTTO Ion Mass Spectrometer (IMS) experiment designated the High Energy Range Spectrometer (HERS) is discussed. Topics covered include: design of the total ion-optical system for the HERS analyzer; the preparation of the design of analyzing magnet; the evaluation of microchannel plate detectors and associated two-dimensional anode arrays; and the fabrication and evaluation of two flight-suitable units of the complete ion-optical analyzer system including two-dimensional imaging detectors and associated image encoding electronics.

Shelley, E. G.↗

Search for acoustic signals from high energy cascades

High energy cosmic ray secondaries can be detected by means of the cascades they produce when they pass through matter. When the charged particles of these cascades ionize the matter they are traveling through, the heat produced and resulting thermal expansion causes a thermoacoustic wave. These sound waves travel at about one hundred-thousandth the speed of light, and should allow an array of acoustic transducers to resolve structure in the cascade to about 1 cm without high speed electronics or segmentation of the detector.

Bell, R.↗

Measuring the energy spectrum of primary cosmic rays with the Yakutsk EAS array

The Yakutsk Extensive Air Showers (EAS) array was designed for detecting the showers generated by the 10 to the 47th power to 10 to the 20th power eV primary cosmic rays and consists of numerous electron, muon, and Cerenkov light detectors arranged on a 20 sq km area terrain. The array is featured by the feasibility to detect the EAS-produced Cerenkov light, hence, as will be shown, to find the mean energy of the primary particles generating an ensemble of EAS of given size. Date collected is discussed.

Khristiansen, G. B.↗

Data inversion algorithm development for the hologen occultation experiment

The successful retrieval of atmospheric parameters from radiometric measurement requires not only the ability to do ideal radiometric calculations, but also a detailed understanding of instrument characteristics. Therefore a considerable amount of time was spent in instrument characterization in the form of test data analysis and mathematical formulation. Analyses of solar-to-reference interference (electrical cross-talk), detector nonuniformity, instrument balance error, electronic filter time-constants and noise character were conducted. A second area of effort was the development of techniques for the ideal radiometric calculations required for the Halogen Occultation Experiment (HALOE) data reduction. The computer code for these calculations must be extremely complex and fast. A scheme for meeting these requirements was defined and the algorithms needed form implementation are currently under development. A third area of work included consulting on the implementation of the Emissivity Growth Approximation (EGA) method of absorption calculation into a HALOE broadband radiometer channel retrieval algorithm.

Gordley, Larry L.↗

Frequency-Tracking-Error Detector

Frequency-tracking-error detector compares average period of output signal from band-pass tracking filter with average period of signal of frequency 100 f(sub 0) that controls center frequency f(sub 0) of tracking filter. Measures difference between f(sub 0) and frequency of one of periodic components in output of bearing sensor. Bearing sensor is accelerometer, strain gauge, or deflectometer mounted on bearing housing. Detector part of system of electronic equipment used to measure vibrations in bearings in rotating machinery.

Randall, Richard L.↗

Low-background detector arrays for infrared astronomy

The status of a program which develops and characterizes integrated infrared (IR) detector array technology for space astronomical applications is described. The devices under development include intrinsic, extrinsic silicon, and extrinsic germanium detectors, coupled to silicon readout electronics. Low-background laboratory test results include measurements of responsivity, noise, dark current, temporal response, and the effects of gamma-radiation. In addition, successful astronomical imagery has been obtained on some arrays from this program. These two aspects of the development combine to demonstrate the strong potential for integrated array technology for IR space astronomy.

Mccreight, C. R.↗

Chandra X-Ray Observatory's Radiation Environment and the AP-8/AE-8 Model

The Chandra X-ray Observatory (CXO) was launched on July 23, 1999 and reached its final orbit on August 7, 1999. The CXO is in a highly elliptical orbit, approximately 140,000 km x 10,000 km, and has a period of roughly 63.5 hours (approx. 2.6 days). It transits the Earth's Van Allen belts once per orbit during which no science observations can be performed due to the high radiation environment. The Chandra X-ray Observatory Center (CXC) currently uses the National Space Science Data Center's "near Earth" AP-8/AE-8 radiation belt model to predict the start and end times of passage through the radiation belts. However, our scheduling software only uses a simple dipole model of the Earth's magnetic field. The resulting B, L magnet coordinates, do not always give sufficiently accurate predictions of the start and end times of transit of the Van Allen belts. We show this by comparing to the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument. We present evidence that demonstrates this mis- of the radiation belts as well as data that also demonstrate the significant variability of one radiation belt transit to the next as experienced by the CXO. We present an explanation for why the dipole implementation of the AP-8/AE-8 gives inaccurate results. We are also investigating use of the Magnetospheric Specification and Forecast Model (MSM) - a model that also accounts for radiation belt variability and geometry.

Virani, S. N.↗

Effects of Hydrogen on Tantalum Nitride Resistors

This document is a presentation about the investigation of drift reported in static frequency output from the analog circuit of a Multichannel Microwave Integrated circuit hybrid microelectronic filter module for space flight application. Electron Dispersion X-Ray Detector )EDAX) Analysis of the 35k ohm thin film Tantalum Nitride Chip resistors identified Palladium in the film. A catalytic reaction of Palladium and hydrogen produces mono atomic hydrogen. When the filter module cavities were filled with a 4 % hydrogen 96 % Nitrogen gas mixture at 25C and monitored the electrical performance for 24 hours. Some channels drifted in a similar pattern as the channel being investigated. Palladium was found on the resistors. The corrective actions taken are reviewed, which resulted in a stable circuit.

Weiler, James↗

JSC Particle Telescope

This paper presents a detailed description of the Johnson Space Center's Particle Telescope. Schematic diagrams of the telescope geometry and an electronic block diagram of the detector telescopes' components are also described.

Badhwar, G. D.↗

Breakthrough Sensor Technology for Space Exploration in the 21st Century

The Breakthrough Sensors and Instrument Component Technology (BSICT) thrust area fosters the develop of breakthrough technology in the areas of detectors, sensors, lasers, coolers and electronics to enable a new set of exciting NASA missions in the new millennium.

BSICT NASA UV QWIP RADAR IR↗

Heavy Isotope Composition of Oxygen in Zircon from Soil Sample 14163: Lunar Perspective of an Early Ocean on the Earth

Thirty oxygen analyses of a large (sub-millimetre) zircon grain from the lunar soil sample 14163 have been determined using CAMECA 1270 ion microprobe. The sample 14163 was returned form the Fra Mauro region by Apollo 14 mission. Zircon grain of 0.6-0.8 mm in size extracted from the sample was imaged using CL detector fitted to the Philips Electron Microscope in order to reveal internal structure. Oxygen isotopes have been analysed during two sessions. The first set of data was collected using the original mount where the grain was set in the resin attached to the glass slide. This resulted in the two complications: (i) standard zircon has to be analysed from the separate mount and (ii) the lunar zircon grain was rased in the holder compared to the standard. In order to investigate, if the elevated oxygen compositions observed during this session could have resulted from this difference in geometric configuration during the standard and sample analyses, the lunar zircon was extracted from the original mount, remounted with the standard chip in the new resin disk and reanalysed during the second session. All analyses made during the first session show delta O-18 values heavier than 6.0%. The second set of data has a wider spread of delta O-18 values with some values as low as 5.6%. Nevertheless, a half of observed delta O-18 values in this set is also higher than 6.0%. Slightly lighter oxygen compositions observed during the second session indicate possible dependence of measured delta O-18 values on the geometry of analysed samples. Presence of zircons with similar heavy oxygen isotope compositions on the Moon, which neither had liquid water or felic crust similar to that on the Earth nor ever developed regime similar to plate tectonics, suggests that other mechanisms can be responsible for elevated delta O-18 values in zircons. This implies that there is no support for the presence of an ocean on the surface of the early Earth and as the ocean appears to be an essential ingredient for the plate tectonics, there is no basis for belief that this mechanism was operating in the early history of the planet.

Nemchin, A. A.↗

Using Digital Radiography To Image Liquid Nitrogen in Voids

Digital radiography by use of (1) a field-portable x-ray tube that emits low-energy x rays and (2) an electronic imaging x-ray detector has been found to be an effective technique for detecting liquid nitrogen inside voids in thermal-insulation panels. The technique was conceived as a means of investigating cryopumping (including cryoingestion) as a potential cause of loss of thermal insulation foam from space-shuttle external fuel tanks. The technique could just as well be used to investigate cryopumping and cryoingestion in other settings. In images formed by use of low-energy x-rays, one can clearly distinguish between voids filled with liquid nitrogen and those filled with gaseous nitrogen or other gases. Conventional film radiography is of some value, but yields only non-real-time still images that do not show time dependences of levels of liquids in voids. In contrast, the present digital radiographic technique yields a succession of images in real time at a rate of about 10 frames per second. The digitized images can be saved for subsequent analysis to extract data on time dependencies of levels of liquids and, hence, of flow paths and rates of filling and draining. The succession of images also amounts to a real-time motion picture that can be used as a guide to adjustment of test conditions.

Cox, Dwight↗

NASA Tech Briefs, July 2012

Topics covered include: Instrument Suite for Vertical Characterization of the Ionosphere-Thermosphere System; Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure; Pattern Recognition Algorithm for High-Sensitivity Odorant Detection in Unknown Environments; Determining Performance Acceptability of Electrochemical Oxygen Sensors; Versatile Controller for Infrared Lamp and Heater Arrays; High-Speed Scanning Interferometer Using CMOS Image Sensor and FPGA Based on Multifrequency Phase-Tracking Detection; Ultra-Low-Power MEMS Selective Gas Sensors; Compact Receiver Front Ends for Submillimeter-Wave Applications; Dynamically Reconfigurable Systolic Array Accelerator; Blocking Losses With a Photon Counter; Motion-Capture-Enabled Software for Gestural Control of 3D Mod; Orbit Software Suite; CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW); Trajectory Software With Upper Atmosphere Model; ALSSAT Version 6.0; Employing a Grinding Technology to Assess the Microbial Density for Encapsulated Organisms; Demonstration of Minimally Machined Honeycomb Silicon Carbide Mirrors; Polyimide Aerogel Thin Films; Nanoengineered Thermal Materials Based on Carbon Nanotube Array Composites; Composite Laminate With Coefficient of Thermal Expansion Matching D263 Glass; Robust Tensioned Kevlar Suspension Design; Focal Plane Alignment Utilizing Optical CMM; Purifying, Separating, and Concentrating Cells From a Sample Low in Biomass; Virtual Ultrasound Guidance for Inexperienced Operators; Beat-to-Beat Blood Pressure Monitor; Non-Contact Conductivity Measurement for Automated Sample Processing Systems; An MSK Radar Waveform; Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures; Method to Remove Particulate Matter from Dusty Gases at Low Pressures; Terahertz Quantum Cascade Laser With Efficient Coupling and Beam Profile; Measurement Via Optical Near-Nulling and Subaperture Stitching; 885-nm Pumped Ceramic Nd:YAG Master Oscillator Power Amplifier Laser System; Airborne Hyperspectral Imaging System; Heat Shield Employing Cured Thermal Protection Material Blocks Bonded in a Large-Cell Honeycomb Matrix; and Asymmetric Supercapacitor for Long-Duration Power Storage.

Source record↗

L’Ralph Integration and Testing

This paper describes the plans, flows, key facilities, components and equipment necessary to fully integrate, functionally test, qualify and calibrate the L’Ralph instrument on the Lucy observatory. Lucy is currently in the final design and fabrication phase (phase C) of mission development. It is scheduled to launch out of Cape Canaveral, Florida, in October 2021. Lucy will be the first space mission to study the Trojan asteroids associated with Jupiter, that are thought to be remnants of the primordial material that formed the outer planets. Lucy will fly by and carry out remote sensing on six different Trojan asteroids. The mission takes its name from the fossilized human ancestor (called “Lucy” by her discoverers) whose skeleton provided unique insight into humanity's evolution. Likewise, the Lucy mission will revolutionize our knowledge of planetary origins and the formation of the solar system. L’Ralph is one of the instruments on Lucy and it is provided by the NASA Goddard Space Flight Center (GSFC). L’Ralph is a combined multi-band visible imager (the Multi-spectral Visible Imaging Camera, MVIC, 0.4-0.85 microns) and wedge-filter infrared spectrometer (Linear Etalon Imaging Spectral Array, LEISA, 1-3.6 microns). LEISA will allow the team to look for the absorption lines that serve as the fingerprints for different silicates, ices and organics that likely will be on the surface of the Trojan asteroids. MVIC will take color images of the Trojan asteroid targets, and help determine how active they are. This paper will focus on the Integration and Test (I&T) activities for L’Ralph while it is at the NASA GSFC. L’Ralph has two assemblies, the telescope detector assembly (TDA) and main electronics box (MEB). The TDA is a single telescope feeding two focal planes, MVIC and LEISA. L’Ralph integration consists of assembly and alignment of the telescope, electronics box integration, thermal systems integration and the final assembly and testing. This I&T phase will be followed by the L’Ralph calibration and characterization, environmental tests which include electromagnetic interference (EMI)/electromagnetic compatibility (EMC), vibration with sine sweep, acoustics, shock, thermal balance, thermal vacuum, mass properties and center of gravity determination. This paper will briefly discuss L’Ralph shipment and delivery to the spacecraft vendor for observatory level I&T as well as some launch preparation activities.

Spaceflight Instruments↗

Simulation of the Charged Particle Deflection From the Sweeping Magnet Array in the Lunar Environment Heliospheric X-Ray Imager

The Lunar Environment heliospheric X-ray Imager (LEXI) is an instrument built to image x-rays from solar wind charge exchange in Earth’s magneto sheath. Monitoring the position of the magnetopause at the inner boundary of the magneto sheath allows us to understand how magnetic reconnection regulates how energy from the solar wind is deposited into Earth’s magnetosphere. LEXI is part of an upcoming lunar lander mission set to land in Mare Crisium. To repel unwanted charged particles, the instrument carries a permanent magnet array composed of 48 neodymium magnets. The array was designed to maximize charged particle deflection while minimizing stray magnetic fields, which could impact other instruments or spacecraft operation. A Runge–Kutta-based fully kinetic particle tracing model was created to evaluate the effectiveness of LEXI’s unique charged particle deflector array. Combined with the other particle suppression measures of the instrument, including physical structures and filters, the simulations show proton and electron transmission to the LEXI detector is expected to be sufficiently reduced to allow successful imaging. The flexible simulation model can be generalized to be used in examining the magnetic deflector array effectiveness of other instruments whose signals could be compromised by unwanted charged particle contamination.

Space environment effects↗

Validation of the NOνA experiment 2023-tuning on simulated neutrino-matter interactions

NOνA is a long-baseline neutrino oscillation experiment that utilizes a two-detector design to study the oscillations of muon neutrinos into electron neutrinos over a baseline of 810 km. The Near Detector (ND) measures the neutrino beam spectrum and composition before oscillation, which is then compared to the oscillated neutrino energy spectrum observed in the Far Detector (FD). In the ND, the neutrinos are detected through their interactions with the heavy target nuclei within the detector. NOνA employs the GENIE neutrino event generator for simulating these neutrino-nucleus interactions. However, the default GENIE prediction does not adequately reproduce the ND data. To address this, NOνA developed a tune of the neutrino interaction models within GENIE version 3:0:6 to minimize discrepancies between the simulated predictions and the observed data in the ND. This dissertation tests the NOνA’s 2023 tune of the GENIE neutrino cross-section simulations by performing a data/simulations comparison for the ND. The analysis employed datasets comprising $2.55\times10^{21}$ protons-on-target (POT) in neutrino beam mode and $1.14\times10^{21}$ POT in antineutrino beam mode. The NOνA tuning of neutrino-matter interaction simulations matches with ND data within the $1\sigma$ error band, overestimating muon neutrino and antineutrino charged current interactions by approximately 6 % and 9 %, respectively. Discrepancies were observed in the energy region dominated by Quasi-Elastic-like interactions. Systematic uncertainties associated with the modeling of the neutrino cross-section, particularly those pertaining Quasi-Elastic like interactions, contributed considerably to the overall error in the simulations. Furthermore, the reconstruction algorithm used in NOνA for particle classification demonstrated significant misidentifications between charged pions and protons, as well as a tendency to overlook additional pions or protons in multi-particle simulated events.

Cortés Parra, Camilo Andrés↗

Helen Edwards Engineering Research Center

The new two-story facility is a critical element in support of Fermilab’s role as host laboratory for the international Deep Underground Neutrino Experiment and the Long-Baseline Neutrino Facility, providing space for engineering and detector R&D. The Edwards Center provides spaces for new endeavors such as liquid-argon detector development, the design of electronics, and chip development.

Fermilab, Fermilab↗