Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical fluids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Improved Thermal-Insulation Systems for Low Temperatures

Improved thermal-insulation materials and structures and the techniques for manufacturing them are undergoing development for use in low-temperature applications. Examples of low-temperature equipment for which these thermal insulation systems could provide improved energy efficiency include storage tanks for cryogens, superconducting electric-power-transmission equipment, containers for transport of food and other perishable commodities, and cold boxes for low-temperature industrial processes. These systems could also be used to insulate piping used to transfer cryogens and other fluids, such as liquefied natural gas, refrigerants, chilled water, crude oil, or low-pressure steam. The present thermal-insulation systems are layer composites based partly on the older class of thermal-insulation systems denoted generally as multilayer insulation (MLI). A typical MLI structure includes an evacuated jacket, within which many layers of radiation shields are stacked or wrapped close together. Low-thermal-conductivity spacers are typically placed between the reflection layers to keep them from touching. MLI can work very well when a high vacuum level (less than 10(exp-4) torr) is maintained and utmost care is taken during installation, but its thermal performance deteriorates sharply as the pressure in the evacuated space rises into the soft vacuum range [pressures greater than 0.1 torr (greater than 13 Pa)]. In addition, the thermal performance of MLI is extremely sensitive to mechanical compression and edge effects and can easily decrease from one to two orders of magnitude from its ideal value even when the MLI is kept under high vacuum condition. The present thermal-insulation systems are designed to perform well under soft vacuum level, in particular the range of 1 to 10 torr. They are also designed with larger interlayer spacings to reduce vulnerability to compression (and consequent heat leak) caused by installation and use. The superiority of these systems is the synergistic effect of improvements in materials, design, and manufacture.

Fesmire, James E.↗

Computational Methods for Multi-Physics Simulation of Melting in Steelmaking

Iron and steel production accounts for approximately 8% of global carbon dioxide (CO) emissions. Pathways to decarbonize include replacing fossil fuels in iron ore reduction and electrifying other steelmaking processes. Iron pellets produced by hydrogen, called Hydrogen Direct Reduced Iron (HDRI), have property differences from those produced using conventional DRI processes. These differences may impact melting in electric arc furnaces (EAF) and other downstream processes. The physical properties of iron pellets vary significantly with temperature during heating, complicating predictions of their behavior. In this project, we seek to develop an integrated simulation, including the fluid flow and convective thermal transport around the pellet particle. We also examine conduction and phase changes within the particle as they impact the melting process. We use adaptive mesh refinement (AMR) to resolve both the changing size of the particle and the complex physics of the interaction between the pellet and the surrounding fluid. We base our simulations on the AMReX-incflo module, which allows large-scale Navier-Stokes simulation while resolving the changing particle size during melting. As we advance our numerical tools, we anticipate an improved understanding of the dynamics of HDRI melting, which will, in turn, accelerate the adoption of low-carbon technologies in the steelmaking industry.

AMReX↗

MODEL DEVELOPMENT AND VERIFICATION OF A 1,350°C AIR RECEIVER TEST SYSTEM

Open-loop volumetric receivers work with air at atmospheric pressure and are suitable for single-cycle or multicycle power plants. A novel additively manufactured (AM) silicon carbide (SiC), ceramic matrix composite (CMC) volumetric receiver was developed that consisted of a lattice structure, which absorbs solar radiation and converts it into heat energy. Heat energy from the porous receiver was transferred to heated ambient air. The receiver acted as a convective heat exchanger, transferring heat to the fluid through convection. Engineering was facilitated to develop a high-temperature air receiver test bed at Sandia national Laboratories (SNL) capable of demonstrating a 50kWth open-loop volumetric SiC air receiver module developed by General Electric Aerospace Research (GE Aerospace). This paper presents the development of the high temperature AM SiC-CMC air receiver, the test bed, and the first testing operations of this device, which was experimentally demonstrated to achieve 1,350°C for over 3.5 hours of operation, based on input flux levels of 67–91 W/cm2 0.5-2.5 kg/s flow rates. From the test campaign results, based on the measured convective heat transfer to the airflow and bounded radiative-loss assumptions, the solar-thermal efficiency of HOTSSTAR test module was estimated to be approximately as high as 74% for representative test conditions.

14 SOLAR ENERGY↗

Investigation of geomagnetic field forecasting and fluid dynamics of the core

The magnetic determination of the depth of the core-mantle boundary using MAGSAT data is discussed. Refinements to the approach of using the pole-strength of Earth to evaluate the radius of the Earth's core-mantle boundary are reported. The downward extrapolation through the electrically conducting mantle was reviewed. Estimates of an upper bound for the time required for Earth's liquid core to overturn completely are presented. High order analytic approximations to the unsigned magnetic flux crossing the Earth's surface are also presented.

Benton, E. R.↗

The Durability of Piston Seals in Hydraulic Power Take-off Systems in Wave Energy Converters

Hydraulic cylinder seals are a critical component of hydraulic power take-off (PTO) systems in wave energy converters (WECs). Primary hydraulic piston seal wear is a major concern for the longevity of hydraulic PTOs, especially in the context of the effort and expense associated with seal replacement. Piston seals, made from polymeric elastomers, are used to contain and isolate high pressure fluids within PTO systems. A specific challenge for WEC designers is knowing, with confidence, the relative expected lifetimes of commercially available seals and seal materials for the unique long travel and continuous use case of WEC hydraulic systems. This information is critical to accurately determine operating expense (OPEX) and levelized cost of electricity (LCOE). If failures of seals occur earlier than their designed lifetime, the estimated operations, and maintenance (O&M) and LCOE costs may double based on estimation. Unfortunately, information from seal manufacturers on longevity in these applications is not generally available and quantitative performance comparison between different manufacturers is not available, creating significant uncertainty on use of hydraulic PTO system in wave power generation. In this project, PNNL, with advice from different WEC device and seal manufacturers, has created a framework to address the industry need for available, dependable and comparative data for seals and seals materials for WEC hydraulic applications including piston seals, glide rings, and shaft seals. Commonly used and candidate seal materials were identified and available information on the materials such as mechanical and fatigue performance, chemical (fluid) compatibility, and cost has been compiled. Hardware and strategy for bench scale measurement of key materials and seal performance and pathway for publicly available library of hydraulic seal materials, properties, suppliers, and options have also been identified for future implementation. The results of this project were presented at WPTO Seedling Symposium 2023 and OCEANS 2023. The results of the literature review including identified polymer seals and ideal operating conditions were summaried and compiled to a database WEC-SealsDB hosted locally at PNNL.

16 TIDAL AND WAVE POWER↗

Energy performance augmentation of domestic refrigerators with microchannel condensers

Refrigerators are one of the most extensively used household appliances, accounting for approximately 4% of total household electricity consumption. Enhancing their energy performance can significantly reduce residential energy demand. As a result, this study focuses on reducing the energy consumption of a French-door, bottom-mount refrigerator using isobutane (R600a) as the working fluid. Here, the performance improvement of the refrigerators has been obtained mainly through improving the vapor compression refrigeration cycle, with a particular emphasis on condenser design. This study explores the impact of three-pass serpentine microchannel condenser on energy performance, along with the effects of two distinct fan combinations. Charge optimization experiments were conducted to identify the optimal refrigerant mass for the refrigerator unit with microchannel condenser. Additionally, a comprehensive numerical model was developed to analyze the behavior of vapor compression cycle under various refrigerant charges. The experimental findings revealed that the refrigerator unit with the three-pass microchannel condenser reduces the energy consumption of isobutane-based domestic refrigerators up to 16% while reducing the refrigerant charge by 11% in comparison to the refrigerator unit with conventional wire-and-tube condenser.

Charge optimization↗

A thermodynamic model of integrated liquid-to-liquid thermoelectric heat pump systems

Thermoelectric (TE) heat pumps (TEHPs) are advantageous for heating and cooling in various applications because of their modularity and simple design. A TEHP system includes the TE modules with p- and n-type materials bonded to substrates, plus heat exchangers, thermal interfaces to the heat exchangers, and heat transfer fluids. Although modeling an individual TE module has been extensively studied, limited studies have reported performance at the larger system-level. Furthermore, no prior study has addressed the impact of temperature-dependent TE material properties (e.g., electric resistivity, thermal conductivity, and Seebeck coefficient) on overall heat-pump-system-level performance. Here, this work presents a mathematical model for TEHP system performance based on Goldsmid's approach for TE material performance, “effective” TE material properties, Gnielinski's correlation for convective heat transfer, and thermal balance theory for a heat exchange network. This combined approach provides an accurate model of the liquid-to-liquid TEHP system. Three different approaches—one empirical, one based on the manufacturer's specifications, and one drawn from the literature—were then used to determine values for TE material properties. The first two methods treated properties as constants, while the last approach treated properties as surface-temperature-based functions. Finally, experimental TEHP data was used to validate the models, all with relative absolute deviations of approximately 10% when predicting heating capacity and 10%–25% when forecasting cooling capacity up to a 30 K surface temperature lift. The results demonstrated that, at the TEHP system level, the TE material properties could be treated as constants, avoiding solver iterations and reducing the performance uncertainty by up to 95%.

42 ENGINEERING↗

Laboratory Observation of Transition from Collisional Slow to Collisionless Fast Reconnection

Temporal transition of an externally driven antiparallel asymmetric magnetic reconnection from collisional slow to collisionless fast regime is observed in a laboratory plasma for the first time. Here, this transition is initiated when the two-fluid Hall effect begins to dominate over collisional effects at the X point, characterized by the ratio of electron-ion collision mean free path to current sheet thickness exceeding unity. Prior to the transition, an enhanced reconnection electric field develops on the low-density side where electrons are heated both ohmically and by large-amplitude lower-hybrid drift waves (LHDW) before collisionality at the X-point drop significantly. These LHDWs generate anomalous resistivity accounting for 30% of the reconnection electric field. The observed time evolution is consistent with the hybrid collisionless-collisional reconnection scenario relevant to onset of asymmetric reconnection in natural plasmas.

Shi, Peiyun [Princeton Plasma Physics Laboratory (↗

HERO WEC V1.0 - WEC-Sim Model

This zip file contains the files that are needed to simulate NREL's HERO WEC (hydraulic and electric reverse osmosis wave energy converter). This requires the user to have already installed WEC-Sim. In addition to the standard toolboxes that are required to run WEC-Sim the user will also need the Simscape Fluids and Simscape Driveline packages. In the zip file you will find the following: - HEROV1_HPTO.slx: Simulink-based WEC Sim model of the first gen (V1.0) Hydraulic PTO (power take-off) that was designed for the HERO WEC - wecSimInputFile.m: Input file needed to run the model - userDefinedFunctionsMCR.m: MCR (multi condition run) script that is needed if a use wants to simulate multiple wave conditions. - geometry (folder): Includes the geometry file that is needed for visualization - hydroData (folder): Includes the required WAMIT data to run WEC-Sim

16 TIDAL AND WAVE POWER↗

HERO WEC V1.0 - WEC-Sim Model (July 2024)

**This submission supersedes submission MHKDR-483** This submission file contains the files that are needed to simulate NREL's HERO WEC (hydraulic and electric reverse osmosis wave energy converter). This requires the user to have already installed WEC-Sim. In addition to the standard toolboxes that are required to run WEC-Sim the user will also need the Simscape Fluids and Simscape Driveline packages. The zip file (HERO_V1_WECSim_2024.zip) contains the following: - HERO_HPTO_2024.slx: Simulink-based WEC Sim model of the first gen (V1.0) Hydraulic PTO (power take-off) that was designed for the HERO WEC. This model has been updated since submission #483 based on in-laboratory experimental results. - wecSimInputFile.m: Input file needed to run the model - userDefinedFunctionsMCR.m: MCR (multi condition run) script that is needed if a use wants to simulate multiple wave conditions. - geometry (folder): Includes the geometry file that is needed for visualization - hydroData (folder): Includes the required WAMIT data to run WEC-Sim -HydVisualization.mlx: Visualization script to plot simulation results (not needed to run)

16 TIDAL AND WAVE POWER↗

Advancements Toward ASME Nuclear Code Case for Compact Heat Exchangers

Our research team proposes to advance the state of the ASME section III code (nuclear service) for Compact Heat Exchangers (CHX). This work will improve the technical state of CHXs and lay the foundation necessary for these heat exchangers to be certified for use in nuclear service. During the course of this work, we will advance the understanding of the performance, integrity, and lifetime of the CHXs for use in any industrial application, making their use more attractive and accessible to the industry. We will do this by developing qualification and inspection procedures that utilize Non-destructive evaluation (NDE) and advanced in-service inspection techniques, with insight from the industrial utility leader EPRI. We have enlisted colleagues at MPR Associates (MPR), an elite nuclear code consulting firm, who are experts on the ASME section III code and who, with input from members of the ASME section III committee, will direct the testing and help develop a series of documents that define the rules and regulations for use of the CHX. Colleagues at North Carolina State University (NCSU) and Oregon State University (OSU) will conduct extensive tensile, creep, and fatigue experiments on diffusion bonded samples (manufactured by US-based Vacuum Process engineering) along with modeling using the elastic perfectly plastic assumptions and comprehensive full inelastic finite element analysis (FEA). This work will allow analysis by design and confidence in the strength of different internal structures. To ensure industry acceptance and long term confidence, team members at the University of Wisconsin–Madison (UW), University of Michigan (UM), Georgia Tech (GT), and the University of Idaho (UI) will extensively test prototypic heat exchangers manufactured by US-based manufactures CompRex and Vacuum Process Engineering (VPE), a leader in the development of advanced CHX. This testing will include the use of various working fluids (salt, sodium, helium, and sCO2) to evaluate operational issues as well as structural integrity under the most severe conditions. Post-test analysis of the tested CHXs coupled with pre/in-service/post NDE (ultrasonic and radiography) led by the Electric Power Research Institute (EPRI) will be incorporated into the development of the rules and regulations for their use in nuclear service.

42 ENGINEERING↗

Supercritical Carbon Dioxide Primary Power Large-Scale Pilot Plant

The United States electrical power generation fleet encompasses a wide range of technologies, ranging from traditional combustion-based power generation, to nuclear power, to renewable energy. While the distribution of these assets continues to shift due to economic and regulatory influences, coal combustion continues to be a key part of the US energy portfolio. Despite the relative maturity of coal combustion technology, improvements in overall fuel-to-power efficiency and generation flexibility are still possible and will improve both the economic and environmental factors of coal combustion. Echogen Power Systems proposes to lead a world-class team including the University of Missouri, Electric Power Research Institute and Louis Perry Associates in the design, construction and operation of a 10MWe coal-fired supercritical carbon dioxide (sCO 2 ) large-scale pilot. This transformational technology uses sCO 2 as a working fluid instead of water to achieve high thermodynamic efficiencies that can significantly exceed advanced steam-Rankine cycles. Further, the compact nature of sCO 2 turbomachinery offers capital cost and footprint advantages, and the low maintenance of a water-free power cycle can significantly reduce operation and maintenance (O&M) costs over conventional steam-Rankine systems. Recent integration studies of sCO 2 with coal combustion power plants highlight the significant improvements in plant efficiency that sCO 2 can offer relative to even advanced steam Rankine cycles. At commercial scales, coal-sCO 2 plant net efficiency is predicted to be 39-44.0% (HHV), or 10-20% higher output than conventional steam-Rankine systems, which will significantly improve the competitiveness of coal-fired generation. This proposal builds upon projects previously funded by the Department of Energy, including DE-FE0025959 (High-Efficiency Thermal Integration of Closed Supercritical CO 2 Brayton Power Cycles with Oxy-Fired Heaters) and DE-NE0008470 (Conceptual Design for sCO 2 Power Cycle Test Facility). An appropriately-scaled and properly designed and operated pilot project is essential to overcome the natural risk-aversion of the power generation industry and project financing community. The 10 MWe coal-fired sCO 2 pilot power plant proposed herein will reduce the technical and economic risk of this transformational technology, enabling commercial deployment at the conclusion of the project. For the second phase of this project, Echogen lead a team that completed and refined the pilot system conceptual system and key component designs resulting in the completion of a front-end-engineering-design (FEED) study, completed the NEPA review process, completed the permitting process for construction and operation, refined the techno-economic analysis of the proposed system at commercial scale and received commitments for Phase III cost share. The end result of the program will be to demonstrate the technical and economic superiority of the sCO 2 power cycle for coal-fired operation. Major risk elements will have been retired with sufficient operation at high power to enable the power generation industry to move forward with the first commercial deployment of this transformational system.

01 COAL, LIGNITE, AND PEAT↗

Design and preliminary testing of a Brayton space radiator concept

A low-temperature radiator has been designed to reject 17.62 kW of thermal power from an isotope Brayton power system. This power system has an electrical output of 7.1 kW. The total radiator consists of two radiators connected in series. Both radiators have a redundant coolant loop, shared fins, and are close to flight configuration. A silicone oil is used as the working fluid. Low flow rates and moderate pressure drop in the radiator required a small hydraulic diameter with large heat transfer area and large flow area. To obtain these characteristics and meet schedule limitations, an expanded tube configuration (with an approximately trapezoidal cross section) was selected. Because of the low flow rates and unconventional tube shape, small scale tests were performed to evaluate the validity of existing heat transfer and pressure drop correlations to this case. The results of these tests were in good agreement with predictions.

Miller, T. J.↗

Scale lengths in quasi-parallel shocks

Examples of an interplanetary and the bow shock illustrate the small relative size of the electrostatic layer relative to the scale of the magnetic fluctuations in quasi-parallel shocks. While both examples are supercritical, the interplanetary example is marginally so, showing a thickness in absolute and convected ion larmor radii units that is thicker (approximately 13 U/omega sub ci) than at the bow shock (approximately omega sub ci). The fluid speed changes abruptly in the quasi-parallel shock on this shorter scale. The increase in electron and ion random energies also is clearly seen on this shorter scale. In the interplanetary example the scale of the electric layer is certainly less than 1/60th that of the up or downstreams magnetic fluctuations. The thickness of the earth's bow shock deceleration layer is dramatically narrower than any domain of upstream waves as controlled by reflected, intermediate, or diffuse ions.

Scudder, J. D.↗

A hybrid simulation of contact discontinuity

Contact discontinuities in a collisionless plasma are studied by hybrid simulations, in which ions are treated as particles and electrons are considered as a fluid. It is demonstrated that contact discontinuity with a stable density ramp can exist in cases with a finite electron temperature. An electron pressure gradient is present across the contact discontinuity, leading to the presence of a parallel electric field and hence field-aligned potential increase (Delta Phi (sub parallel)) in the transition region. By reflecting ions at the discontinuity, this parallel electric potential peak reduces the interpenetration between hot and cold ions and maintains a stable density ramp across the contact discontinuity. The ratio of the field-aligned electric potential energy to ion thermal energy, e(Delta) Phi(sub parallel)/kT(sub i), is found to be an increasing function of T(sub e)/T(sub i), where T(sub e) and T(sub i) are respectively the electron and ion temperature.

Wu, B. H.↗

L-C Measurement Acquisition Method for Aerospace Systems

This paper describes a measurement acquisition method for aerospace systems that eliminates the need for sensors to have physical connection to a power source (i.e., no lead wires) or to data acquisition equipment. Furthermore, the method does not require the sensors to be in proximity to any form of acquisition hardware. Multiple sensors can be interrogated using this method. The sensors consist of a capacitor, C(p), whose capacitance changes with changes to a physical property, p, electrically connected to an inductor, L. The method uses an antenna to broadcast electromagnetic energy that electrically excites one or more inductive-capacitive sensors via Faraday induction. This method facilitates measurements that were not previously possible because there was no practical means of providing power and data acquisition electrical connections to a sensor. Unlike traditional sensors, which measure only a single physical property, the manner in which the sensing element is interrogated simultaneously allows measurement of at least two unrelated physical properties (e.g., displacement rate and fluid level) by using each constituent of the L-C element. The key to using the method for aerospace applications is to increase the distance between the L-C elements and interrogating antenna; develop all key components to be non-obtrusive and to develop sensing elements that can easily be implemented. Techniques that have resulted in increased distance between antenna and sensor will be presented. Fluid-level measurements and pressure measurements using the acquisition method are demonstrated in the paper.

Woodard, Stanley E.↗

Binary Colloidal Alloy Test Conducted on Mir

Colloids are tiny (submicron) particles suspended in fluid. Paint, ink, and milk are examples of colloids found in everyday life. The Binary Colloidal Alloy Test (BCAT) is part of an extensive series of experiments planned to investigate the fundamental properties of colloids so that scientists can make colloids more useful for technological applications. Some of the colloids studied in BCAT are made of two different sized particles (binary colloidal alloys) that are very tiny, uniform plastic spheres. Under the proper conditions, these colloids can arrange themselves in a pattern to form crystals. These crystals may form the basis of new classes of light switches, displays, and optical devices. Windows made of liquid crystals are already in the marketplace. These windows change their appearance from transparent to opaque when a weak electric current is applied. In the future, if the colloidal crystals can be made to control the passage of light through them, such products could be made much more cheaply. These experiments require the microgravity environment of space because good quality crystals are difficult to produce on Earth because of sedimentation and convection in the fluid. The BCAT experiment hardware included two separate modules for two different experiments. The "Slow Growth" hardware consisted of a 35-mm camera with a 250- exposure photo film cartridge. The camera was aimed toward the sample module, which contained 10 separate colloid samples. A rack of small lights provided backlighting for the photographs. The BCAT hardware was launched on the shuttle and was operated aboard the Russian space station Mir by American astronauts John Blaha and David Wolf (launched September 1996 and returned January 1997; reflown September 1997 and returned January 1998). To begin the experiment, one of these astronauts would mix the samples to disperse the colloidal particles and break up any crystals that might have already formed. Once the samples were mixed and the experiment was powered on, the hardware operated autonomously, taking photos of the colloidal samples over a 90-day period.

Hoffmann, Monica I.↗

Heat Transfer Characteristics of Particle and Air Flow Through Additively Manufactured Lattice Frame Material Based on Octet-Shape Topology

Particle-to-supercritical carbon dioxide (sCO 2 ) heat exchanger is a critical component in next-generation concentrating solar power (CSP) plants. The inherently low heat transfer between falling particles and sCO 2 imposes a challenge toward economic justification of levelized cost of electricity produced through solar energy. Introduction of integrated porous media with the walls bounding particle flow has the potential to enhance the overall particle-to-sCO 2 heat exchanger performance. Here, this paper presents an experimental study on heat transfer characterization of additively manufactured lattice frame material based on Octet-shaped unit cell with particles and air as working fluids. The lattice structures were additively manufactured in stainless steel (SS) 316L and SS420 (with 40% bronze infiltration) via Binder jetting process, where the lattice porosities were varied between 0.75 and 0.9. The mean particle diameters were varied from 266 μm to 966 μm. The effective thermal conductivity and averaged heat transfer coefficient were determined through steady-state experiments. It was found that the presence of lattice enhances the effective thermal conductivity by 2–4 times when compared to packed bed of particles alone. Furthermore, for gravity-assisted particle flow through lattice panel, significantly high convective heat transfer coefficients ranging from 200 W/m2K to 400 W/m2K were obtained for the range of particle diameters tested. The superior thermal transport properties of Octet-shape-based lattice frame for particle flow makes it a very promising candidate for particle-to-sCO 2 heat exchanger for CSP application.

14 SOLAR ENERGY↗