Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “effective area”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Application of contact theory to metal-metal bonding of silicon wafers

A model is presented which relates the applied load and surface roughness to the integrity of metal-metal wafer-level thermocompression bonds. Using contact theory, the true contact area is calculated as a function of the applied load and surface roughness as characterized using atomic force microscopy. The relationship between the nominal and true contact areas quantifies the effects of applied load and surface roughness on the bond integrity of the bonded wafers as indicated by the dicing yield. Experiments on Cu-Cu bonds show that the true contact area provides a better indicator of bond integrity than either the nominal contact area or applied force, taken together or separately.

36 MATERIALS SCIENCE↗

Ablation article and method

An ablation article, such as a conical heat shield, having an ablating surface is provided with at least one discrete area of at least one seed material, such as aluminum. When subjected to ablation conditions, the seed material is ablated. Radiation emanating from the ablated seed material is detected to analyze ablation effects without disturbing the ablation surface. By providing different seed materials having different radiation characteristics, the ablating effects on various areas of the ablating surface can be analyzed under any prevailing ablation conditions. The ablating article can be provided with means for detecting the radiation characteristics of the ablated seed material to provide a self-contained analysis unit.

Erickson, W. D.↗

Morphology of Nano and Micro Fiber Structures in Ultrafine Particles Filtration

Selected procedures permitting to prepare homogeneous nanofibre structures of the desired morphology by employing a suitable combination of variables during the electrospinning process are presented. A comparison (at the same pressure drop) was made of filtration capabilities of planar polyurethane nanostructures formed exclusively by nanofibres, space polycarbonate nanostructures having bead spacers, structures formed by a combination of polymethyl methacrylate micro- and nanofibres and polypropylene meltblown microstructures, through which ultrafine particles of ammonium sulphate 20-400 nm in size were filtered. The structures studied were described using a new digital image analysis technique based on black and white images obtained by scanning electron microscopy. More voluminous structures modified with distance microspheres and having a greater thickness and mass per square area of the material, i.e. structures possessing better mechanical properties, demanded so much in nanostructures, enable preparation of filters having approximately the same free volume fraction as flat nanofibre filters but an increased effective fibre surface area, changed pore size morphology and, consequently, a higher filter quality.

36 MATERIALS SCIENCE↗

Phenological Versus Meteorological Controls on Land-atmosphere Water and Carbon Fluxes

Phenological dynamics and their related processes strongly constrain land-atmosphere interactions, but their relative importance vis-à-vis meteorological forcing within general circulation models (GCMs) is still uncertain. Using an off-line land surface model, we evaluate leaf area and meteorological controls on gross primary productivity, evapotranspiration, transpiration, and runoff at four North American sites, representing different vegetation types and background climates. Our results demonstrate that compared to meteorological controls, variation in leaf area has a dominant control on gross primary productivity, a comparable but smaller influence on transpiration, a weak influence on total evapotranspiration, and a negligible impact on runoff. Climate regime and characteristic variations in leaf area have important modulating effects on these relative controls, which vary depending on the fluxes and timescales of interest. We find that leaf area in energylimited evaporative regimes tends to exhibit greater control on annual gross primary productivity than in moisture-limited regimes, except when vegetation exhibits little interannual variation in leaf area. For transpiration, leaf area control is somewhat less in energylimited regimes and greater in moisture-limited regimes for maximum pentad and annual fluxes. These modulating effects of climate and leaf area were less clear for other fluxes and at other timescales. Our findings are relevant to land-atmosphere coupling in GCMs, especially considering that leaf area variations are a fundamental element of land use and land cover change simulations.

Puma, Michael J.↗

Effects of anisosmotic stress on cardiac muscle cell length, diameter, area, and sarcomere length

The purpose of this study was to examine the effects of anisosmotic stress on adult mammalian cardiac muscle cell (cardiocyte) size. Cardiocyte size and sarcomere length were measured in cardiocytes isolated from 10 normal rats and 10 normal cats. Superfusate osmolarity was decreased from 300 +/- 6 to 130 +/- 5 mosM and increased to 630 +/- 8 mosM. Cardiocyte size and sarcomere length increased progressively when osmolarity was decreased, and there were no significant differences between cat and rat cardiocytes with respect to percent change in cardiocyte area or diameter; however, there were significant differences in cardiocyte length (2.8 +/- 0.3% in cat vs. 6.1 +/- 0.3% in rat, P < 0.05) and sarcomere length (3.3 +/- 0.3% in cat vs. 6.1 +/- 0.3% in rat, P < 0.05). To determine whether these species-dependent differences in length were related to diastolic interaction of the contractile elements or differences in relative passive stiffness, cardiocytes were subjected to the osmolarity gradient 1) during treatment with 7 mM 2,3-butanedione monoxime (BDM), which inhibits cross-bridge interaction, or 2) after pretreatment with 1 mM ethylene glycol-bis(beta-aminoethyl ether)-N, N,N',N'-tetraacetic acid (EGTA), a bivalent Ca2+ chelator. Treatment with EGTA or BDM abolished the differences between cat and rat cardiocytes. Species-dependent differences therefore appeared to be related to the degree of diastolic cross-bridge association and not differences in relative passive stiffness. In conclusion, the osmolarity vs. cell size relation is useful in assessing the cardiocyte response to anisosmotic stress and may in future studies be useful in assessing changes in relative passive cardiocyte stiffness produced by pathological processes.

Non-NASA Center↗

EFFECT OF PRETREATMENT ON PT-CO/C CATHODE CATALYSTS FOR THE OXYGEN-REDUCTION REACTION

In order to reduce the precious metal loading without sacrificing activity and stability, a new method for the preparation of bimetallic catalysts is proposed. Currently, Pt-alloy particles, with 2 to 3 nm in diameter, are loaded on high surface area carbon supports. Of the Pt loaded, only the surface atoms interact with the reactants. In order to increase the Pt utilization per metal particle the new process for catalyst preparation will incorporate a non-noble transition metal core coated with a skin layer of Pt deposited on high surface area carbon. The effect of reducing agent strength during synthesis was also explored. It was determined that the Co addition has a higher impact on catalyst when used with NaBH4 as reducing agent as compared to NaCOOH.

08 HYDROGEN↗

Development of broadband X-ray interference lithography large area exposure system

The single-exposure patterned area is about several 10{sup 2} × 10{sup 2} μm{sup 2} which is mainly decided by the mask area in multi-beam X-ray interference lithography (XIL). The exposure area is difficult to stitch to a larger one because the patterned area is surrounded by 0th diffraction exposure areas. To block the 0th diffraction beams precisely and effectively, a new large area exposure technology is developed in the Shanghai Synchrotron Radiation Facility by applying an order-sorting aperture with a new in situ monitoring scheme in the XIL system. The patterned area could be stitched readily up to several square centimeters and even bigger by this technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Features of the capacitance-voltage characteristics in a MOS structure due to the oxide charge

MOS structures based on p-and n-type silicon and subjected to the effect of voltages of both polarities with a magnitude as large as 70 V are studied. In all cases, an increase in the effective positive charge at the Si/SiO{sub 2} boundary was observed. In the case of structures with p-Si, a steplike increase in the high-frequency capacitance in the inversion region at some value of the threshold voltage was observed. The increase in the capacitance and the threshold voltage were governed by the value of the effective charge and the area of the gate of the structure. The observed effect is accounted for by lateral diffusion of free electrons accumulated in the semiconductor in the vicinity of the gate contact. After completion of the effect of the voltage on the structures, the capacitance-voltage characteristics were recovered to the state close to the initial state in the relaxation time characteristic of reverse drift of ions and emission of charge carriers by tunneling from 'slow' traps in the vicinity of the Si/SiO{sub 2} interface.

36 MATERIALS SCIENCE↗

Theoretical jet exhaust noise model for the duct burning turbofan

A model was developed to predict the acoustic power spectrum for a Duct Burning Turbofan (DBTF) whose cycle results in a high velocity, high temperature fan stream and a lower velocity, lower temperature primary stream. Model tests have demonstrated that a DBTF may produce substantially less noise than a conventional turbojet with the same thrust and weight flow. Predictions from the model agreed well with measured data from the model tests. The characteristics of the DBTF acoustic power spectrum were shown to be related to the rapid mixing of the fan and primary streams. The effects of fan to primary velocity ratio, temperature ratio, area ratio, and the effect of nozzle geometry on DBTF jet noise were determined.

Larson, R. S.↗

IDE spatio-temporal impact fluxes and high time-resolution studies of multi-impact events and long-lived debris clouds

During the first 12 months of the Long Duration Exposure Facility (LDEF) mission, the Interplanetary Dust Experiment (IDE) recorded over 15,000 total impacts on six orthogonal faces with a time resolution on the order of 15 to 20 seconds. When combined with the orbital data and the stabilized configuration of the spacecraft, this permits a detailed analysis of the micro-particulate environment. The functional status of each of the 459 detectors was monitored every 2.4 hours, and post-flight analyses of these data has now permitted an evaluation of the effective active detection area as a function of time, panel by panel and separately for the two sensitivity levels. Thus, total impacts were transformed into areal fluxes, and are presented here for the first time. Also discussed are possible effects of these fluxes on previously announced results: apparent debris events, meteor stream detections, and beta meteoroids in observationally significant numbers.

Mulholland, J. Derral↗

Investigation of Radiation Cross-Talk Effects on Biological Dose Rates in Maintenance Areas Inside the ITER Tokamak - Paper 107

The intense plasma neutron source of ITER requires careful consideration of radiation safety during the design of the machine, its operation plan and licensing process. One important issue is that of occupational radiation exposure (ORE) during in-situ maintenance activities inside the cryostat, and particularly in the port inter-space area (PI) where up keeping of port systems should take place (diagnostics, tritium breeding test modules, heating antennas). ITER ports and port plugs (PP) become activated by neutron irradiation during plasma operation; from the subsequent decay and gamma emission of irradiated materials, the so-called shutdown dose rate field (SDR) appears. A project requirement of 100 uSv/h after 12 days exists for the SDR in the PI in order to limit exposure during maintenance and meet ORE regulatory limits. This requirement is particularly challenging for equatorial ports (EP) due to, among others, background neutron radiation and activation from/by neighbouring components (a.k.a. 'cross-talk'), and particularly the lower ports (LP). For a particular port inter-space, the SDR field is a combination of: (i) the gamma dose due to the activation of components local to the PI, typically referring to the PI itself plus the port plug, port duct and bellows, vessel extension and blankets in its vicinity; (ii) the gamma dose due to activation of components far away from the PI, a.k.a. the cross-talk, which typically refers to other ports, cryostat and rest of the vacuum vessel and blankets. The situation is complicated to some extent by the fact that both these components can arise from a combination of irradiation by local neutrons, i.e. those permeating through the vicinity of the port itself, and by cross-talk neutrons, i.e. those permeating via other paths. In simple terms, the so-called 'neutron cross-talk' refers to neutron leakage through other ports and components producing activation, decay gammas and dose locally in the PI of interest, whereas the 'gamma cross-talk' refers to activation and decay gammas in other ports producing dose in the PI from far away. The study reported here focuses on the evaluation of the effect of radiation cross-talk from a torus cryopump (TCP) LP located directly underneath a generic diagnostics equatorial port plug (DEPP) in the equatorial port itself. This is considered the worst case scenario, as the TCP-LP has a large aperture and has to be mostly empty in order to meet TCP pumping requirements. For the reference case and R1, the neutron cross-talk from the LP activating the EP is responsible for 109 uSv/h. In addition, a gamma cross-talk of 51 uSv/h from LP activation has been found. The total cross-talk contribution is therefore responsible for 160 uSv/h of SDR at EP PI. The local SDR contribution, i.e. that from activation of the EP with 'local-only' neutrons, is 166 uSv/h. The total SDR at R1 is 360 uSv/h, including some minor contributions from the UP, lateral EPs, cryostat and bio-shield. The total SDR at R2 is 349 uSv/hr, with a cross-talk contribution of 203 uSv/h. In R2 the gamma cross-talk is more intense, as it is closer to the highly activated TCPH. These results illustrate how the SDR field produced by radiation cross-talk through a TCP-LP is comparable in magnitude with that produced by neutron leakage and activation local to the EP. Shielding options are currently under consideration. Local gamma shielding at the EP PI is found to be effective in reducing gamma cross-talk from the LP and TCPH, and also in reducing the local contribution from the port duct and bellows. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Effects in Photonic Modulator Structures

%T Radiation Effects in Photonic Modulator Structures%A Charles Barnes%A Roger Greenwell%J SPIE, Photonics for Space Environments%C Orlando, Florida, U.S.A.%D April 18-20, 1995%K Radiation%K Photonic Modulator Structures%U http://techreports.jpl.nasa.gov/1995/95-1057.pdfA review is given of the effects of radiation on various photonic modulator materials and devices including polymer-based structures, insulator-based devices, semiconductor-based devices and spatial light modulators. We conclude by providing recommendations for further work in the area of radiation effects in photonic modulators.!

Photonic↗

Wickability-optimized textured liquid-desiccant air dehumidifiers for independent moisture management in energy-efficient buildings

Liquid-desiccant-based air conditioning systems are envisioned to enable independent humidity management, thereby improving the energy efficiency of future buildings. Existing liquid-desiccant-based air conditioning concepts, however, suffer from a poor liquid flow distribution deteriorating moisture removal rate. They are consequently flooded with the liquid-desiccant solution, which significantly degrades the energy efficiency of the dehumidification process. Here, in this work, the capillary forces and wickability effect of textured air dehumidifier surfaces are altered to minimize the liquid-desiccant flow rate of the fully wetted state, thereby transforming the physics of interfacial desiccant flow distribution. Consequently, the wickability-optimized air dehumidifier surface maximizes both moisture removal rate and dehumidification energy efficiency. It was interestingly found that the length scale of a textured air dehumidifier surface concept is optimized at an intermediate pattern density. Dry solid-air menisci appear at length scales exceeding the optimum pattern distance while the effective liquid–air interfacial area is reduced at smaller length scales, both of which degrade the moisture removal rate. At the optimum pattern density, the effective liquid–air interfacial area increases with the solution flow rate, thereby increasing the dehumidification rate. At a water vapor pressure potential of 3 kPa and a solution flow rate of 2.8 g/s, experimental results indicated a moisture removal rate of 0.16 g/m2-s for a textured surface concept with a capillary length scale of 3 mm, a 28% improvement compared with that of smooth-plate dehumidifier surfaces. A high moisture removal rate of the textured surface at a low desiccant flow rate led to a high thermal efficiency of 0.75 at a water vapor pressure potential of 5.6 kPa and a LiBr flow rate of 2.8 g/s. The insights gained from the present study accelerate the development of advanced textured surface concepts for next-generation liquid-desiccant-based air dehumidification systems offering independent humidity management for future energy-efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Investigations of a Large Centrifugal Compressor from an Experimental Turbojet Engine

An investigation was conducted on a large centrifugal compressor from an experimental turbojet engine to determine the performance of the compressor and to obtain fundamental information on the aerodynamic problems associated with large centrifugal-type compressors. The results of the research conducted on the compressor indicated that the compressor would not meet the desired engine-design air-flow requirements (78 lb/sec) because of an air-flow restriction in the vaned collector (diffuser). Revision of the vaned collector resulted in an increased air-flow capacity over the speed range and showed improved matching of the impeller and diffuser components. At maximum flow, the original compressor utilized approximately 90 percent of the available geometric throat area at the vaned-collector inlet and the revised compressor utilized approximately 94 percent, regardless of impeller speed. The ratio of the maximum weight flows of the revised and original compressors were less than the ratio of effective critical throat areas of the two compressors because of the large pressure losses in the impeller near the impeller inelt and the difference increased with an increase in impeller speed. In order to further increase the pressure ratio and maximum weight flow of the compressor, the impeller must be modified to eliminate the pressure losses therein.

Ginsburg, Ambrose↗

Scalable Bose-Einstein-condensate Sagnac interferometer in a linear trap

We demonstrate a two-dimensional atom interferometer in a harmonic magnetic waveguide using a Bose-Einstein condensate. Such an interferometer could measure rotation using the Sagnac effect. Compared to free space interferometers, larger interactions times and enclosed areas can in principle be achieved, since the atoms are not in free fall. In this implementation, we induce the atoms to oscillate along one direction by displacing the trap center. We then split and recombine the atoms along an orthogonal direction using an off-resonant optical standing wave. We enclose a maximum effective area of 0.1 mm{sup 2} limited by fluctuations in the initial velocity and by the coherence time of the interferometer. We argue that this arrangement is scalable to enclose larger areas by increasing the coherence time and then making repeated loops.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Response of graywater recycling systems based on hydroponic plant growth to three classes of surfactants

Anionic (sodium laureth sulfate, SLES), amphoteric (cocamidopropyl betaine, CAPB) and nonionic (alcohol polyethoxylate, AE) surfactants were added to separate nutrient film technique (NFT) hydroponic systems containing dwarf wheat (Triticum aestivum cv. USU Apogee) in a series of 21 day trials. Surfactant was added either in a (1). temporally dynamic mode (1-3 g surfactant m(-2) growing area d(-1)) as effected by automatic addition of a 300 ppm surfactant solution to meet plant water demand, or (2). continuous mode (2 g surfactant m(-2) growing area d(-1)) as effected by slow addition (10 mLh(-1)) of a 2000 ppm surfactant solution beginning at 4d after planting. SLES showed rapid primary degradation in both experiments, with no accumulation 24 h after initial addition. CAPB and AE were degraded less rapidly, with 30-50% remaining 24 h after initial addition, but CAPB and AE levels were below detection limit for the remainder of the study. No reductions in vegetative growth of wheat were observed in response to SLES, but biomass was reduced 20-25% with CAPB and AE. Microbial communities associated with both the plant roots and wetted hardware surfaces actively degraded the surfactants, as determined by monitoring surfactant levels following pulse additions at day 20 (with plants) and day 21 (after plant removal). In order to test whether the biofilm communities could ameliorate phytotoxicity by providing a microbial community acclimated for CAPB and AE decay, the continuous exposure systems were planted with wheat seeds after crop removal at day 21. Acclimation resulted in faster primary degradation (>90% within 24h) and reduced phytotoxicity. Overall, the studies indicate that relatively small areas (3-5m(2)) of hydroponic plant systems can process per capita production of mixed surfactants (5-10 g x person(-1)d(-1)) with minimal effects on plant growth.

Hydroponics↗

Numerical Simulation Studies of Ultrasonic De-Icing for Heating, Ventilation, Air Conditioning, and Refrigeration Structures

Ice accumulation on heating, ventilation, air conditioning, and refrigeration (HVACR) structures presents significant operational challenges. These challenges include reduced efficiency, increased energy consumption, and potential damage to equipment. Traditional de-icing methods, such as chemical treatments, mechanical scraping, or heating-based techniques, are often labor-intensive, costly, and environmentally harmful. Here, this study uniquely investigates ultrasonic de-icing as an energy-efficient alternative for HVACR applications, focusing on the specific structural geometries found in these systems. A comprehensive numerical simulation framework was developed using finite element analysis to explore ultrasonic wave propagation across four distinct HVACR structures. Key parameters such as ultrasonic frequency, power levels, and the number and placement of actuators were examined for their impact on ice detachment efficiency. Results from simulations on a plate structure reveal that ultrasonic excitation can propagate effectively across large areas (at least 150 × 150 mm), enhancing the de-icing coverage. Lower frequency (e.g., 30 to 45 kHz) excitation results in greater displacement, improving de-icing performance, while increased actuator numbers with the same total power input also enhance effectiveness. Two actuators seem sufficient for the de-icing of a 300 × 300 mm plate. For tube-and-fin structures, specific high-power ultrasonic frequencies selectively excite the fin plates, demonstrating efficient ice removal when actuated on the tube. However, optimal performance requires careful design of actuator placement and vibration modes to accommodate the irregular shapes of these structures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recent Developments to the Porous Microstructure Analysis (PuMA) Software

Introduction The Porous Microstructure Analysis (PuMA) software is an open source framework for image-based simulation, primarily used to determine effective properties based on material microstructure. PuMA was originally developed for the study of NASA thermal protection materials; however, many of the solvers in PuMA have applicability to a broad range of materials science applications. PuMA version 3.2 computes material surface area, pore diameters, effective thermal conductivity, continuum and rarefied tortuosity, and permeability. For anisotropic materials, PuMA can estimate material orientation and compute anisotropic thermal conductivity and elasticity. In this talk, a brief overview of the PuMA software and underlying methods will be presented, as well as some recent and ongoing developments, including the use of immersed boundary methods for image-based simulation and the development of a new weave segmentation tool, called TomoSAM. Cut-Cell method for heat and mass transfer For simulations on complex microstructures, traditional unstructured meshing techniques often prove to be difficult and time-intensive. Voxel-based solvers, which represent the surface as a staircase structure, are relatively simple to implement but can lose accuracy when feature resolution is poor. In this work, we present a novel 3D cut-cell method for solving the variable coefficient Poisson equation on complex microstructures, suitable for the determination of effective thermal conductivity or tortuosity of a material. The method uses a Marching Cubes/Marching Squares surface reconstruction to create cut-cells and determine geometric quantities. A flux-correction method is extended to 3D, with least squares gradient reconstruction, to solve for the boundary fluxes in the cut-cells. Verification cases show the solver achieves globally 2nd order accuracy on complex microstructures. TomoSAM TomoSAM, a module of the PuMA software, has been developed as a plugin for 3D Slicer, a software platform used for 3D image processing and visualization. It utilizes the Segment Anything Model (SAM), a deep learning model capable of identifying objects and generating image masks based on minimal user input. This feature enables efficient segmentation of complex 3D datasets, particularly of woven materials, from tomography or similar imaging methods, reducing the need for manual segmentation.

Tomography↗