Direct Air Capture-Based Carbon Dioxide Removal with United States Low-Carbon Energy and Sinks
The overall objective of this project was to complete an initial design of a commercial-scale, Carbon Capture and Storage system for Direct Air Capture (CCS-DAC) that separates and stores a minimum of 100,000 tonnes/year (t/yr.) net CO 2 from air. Three geographically diverse host sites will be used to determine the impact of different climates on the design and cost of the CCS-DAC systems; California (dry-hot), Louisiana (humid-hot), and Wyoming (mid-continental). In addition, the impact of using different low-carbon energy sources was also examined. The focus of this project was to geologically store the CO 2 , rather than the utilization of CO 2 . This Final Scientific/Technical Report is a collection of the deliverables for the project. The project team was able to successfully complete all the necessary tasks needed to determine the feasibility of the designs and operational needs of the DAC systems for each location. The data created by this allowed the project team to conduct the required evaluations to meet the requirements of the deliverables. The following deliverables were drafted and submitted to DOE prior to the conclusion of the project: (1) Initial Engineering Design; (2) Costing Estimate; (3) Techno-Economic Analysis (TEA); (4) Life Cycle Analysis (LCA); (5) Business Case Assessment; and (6) Technology EH&S Risk Assessment.