Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “difference frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Resonance vibrations of aircraft propellers

On the basis of the consideration of various possible kinds of propeller vibrations, the resonance vibrations caused by unequal impacts of the propeller blades appear to be the most important. Their theoretical investigation is made by separate analysis of torsional and bending vibrations. This method is justified by the very great difference in the two natural frequencies of aircraft propeller blades. The calculated data are illustrated by practical examples. Thereby the observed vibration phenomenon in the given examples is explained by a bending resonance, for which the bending frequency of the propeller is equal to twice the revolution speed.

Liebers, Fritz↗

Sensitivity analysis of the optimal solution obtained from the structural damage indentification process

An identification procedure proposed by Shen and Taylor to determine the crack characteristics (location and size of the crack) from dynamic measurements is tested. This procedure was based on minimization of either the 'mean-square' measure of difference between measurement data (natural frequencies and mode shapes) and the corresponding predictions obtained from the computational model. The procedure is tested for simulated damage in the form of symmetric cracks in a simply-supported Bernoulli-Euler beam. The sensitivity of the solution of damage identification problems to the values of parameters that characterize damage is discussed. A sensitivity formula is derived.

Shen, Mo-How H.↗

Artifacts Of Spectral Analysis Of Instrument Readings

Report presents experimental and theoretical study of some of artifacts introduced by processing outputs of two nominally identical low-frequency-reading instruments; high-sensitivity servo-accelerometers mounted together and operating, in conjunction with signal-conditioning circuits, as seismometers. Processing involved analog-to-digital conversion with anti-aliasing filtering, followed by digital processing including frequency weighting and computation of different measures of power spectral density (PSD).

Wise, James H.↗

Effects of Centrifuge Diameter and Operation on Rodent Adaptation to Chronic Centrifugation

This study examined the responses of rats to centrifugation in a constant acceleration field (1.5 G). Centrifuge diameter (1.8m, 2.5m or 6.0m) and schedule of operation (Daily or weekly stop) varied between groups. Body mass, food consumption, water consumption and neurovestibular function were measured weekly. Body temperature and activity were continuously monitored using telemetry. A subset of subjects were videotaped (50 minutes per day) to allow for movement analysis. Exposure to a hyperdynamic field of this magnitude did cause the expected depression in the physiological variables monitored. Recovery was accomplished within a relatively rapid time frame; all variables returned to precentrifugation levels. In general, the magnitudes of the changes and the rate of recovery were similar at different centrifuge diameters and stopping frequency. There were cases, however, in which the magnitude of the response and/or the rate of recovery to a new steady-state were altered as a result of centrifuge diameter. In summary, these results indicate that stopping frequency has little, if any, effect on adaptation to chronic centrifugation. However, the angular velocity (omega), and therefore centrifuge diameter is an important consideration in the adaptation of an organism to chronic centrifugation.

Fuller, Charles A.↗

Effects of Centrifuge Diameter and Operation on Rodent Adaptation to Chronic Centrifugation

This study examined the responses of rats to centrifugation in a constant acceleration field (1.5 G). Centrifuge diameter (1.8m, 2.5m or 6.0m) and schedule of operation (Daily or weekly stop) varied between groups. Body mass, food consumption, water consumption and neurovestibular function were measured weekly. Body temperature and activity were continuously monitored using telemetry. A subset of subjects were videotaped (50 minutes per day) to allow for movement analysis. Exposure to a hyperdynamic field of this magnitude did cause the expected depression in the physiological variables monitored. Recovery was accomplished within a relatively rapid time frame; all variables returned to precentrifugation levels. In general, the magnitudes of the changes and the rate of recovery were similar at different centrifuge diameters and stopping frequency. There were cases, however, in which the magnitude of the response and/or the rate of recovery to a new steady-state were altered as a result of centrifuge diameter. In summary, these results indicate that stopping frequency has little, if any, effect on adaptation to chronic centrifugation. However, the angular velocity (omega), and therefore centrifuge diameter is an important consideration in the adaptation of an organism to chronic centrifugation.

Fuller, Charles A.↗

Finding corner point correspondence from wavelet decomposition of image data

A time efficient algorithm for image registration between two images that differ in translation is discussed. The algorithm is based on coarse-fine strategy using wavelet decomposition of both the images. The wavelet decomposition serves two different purposes: (1) its high frequency components are used to detect feature points (corner points here) and (2) it provides coarse-to-fine structure for making the algorithm time efficient. The algorithm is based on detecting the corner points from one of the images called reference image and computing corresponding points from the other image called test image by using local correlations using 7x7 windows centered around the corner points. The corresponding points are detected at the lowest decomposition level in a search area of about 11x11 (depending on the translation) and potential points of correspondence are projected onto higher levels. In the subsequent levels the local correlations are computed in a search area of no more than 3x3 for refinement of the correspondence.

Manohar, Mareboyana↗

Systematic Identification of Preferred Orbits for Magnetospheric Missions: Single Satellites - 1

This is a systematic attempt to identify and assess near-equatorial, high-eccentricity orbits best suited for studying the Earth's magnetosphere, in particular its most dynamic part, the plasma sheet of the magnetotail. The study was motivated by the design needs of a multi-spacecraft "constellation" mission, stressing low cost, minimal active control and economic launch strategies, and both quantitative and qualitative aspects were investigated. On one hand, by collecting hourly samples throughout the year, accurate estimates were obtained of the coverage of different regions, and of the frequency and duration of long eclipses. On the other hand, an intuitive understanding was developed of the factors which determine the merits of the mission, including long-range factors due to perturbations by the Moon, Sun and the Earth's equatorial bulge.

Stern, David P.↗

GPS Signal Scattering from Sea Surface: Wind Speed Retrieval Using Experimental Data and Theoretical Model

Global Positioning System (GPS) signals reflected from the ocean surface have potential use for various remote sensing purposes. Some possibilities arc measurements of surface roughness characteristics from which ware height, wind speed, and direction could be determined. For this paper, GPS-reflected signal measurements collected at aircraft altitudes of 2 km to 5 km with a delay-Doppler mapping GPS receiver arc used to explore the possibility of determining wind speed. To interpret the GPS data, a theoretical model has been developed that describes the power of the reflected GPS signals for different time delays and Doppler frequencies as a function of geometrical and environmental parameters. The results indicate a good agreement between the measured and the modeled normalized signal power waveforms during changing surface wind conditions. The estimated wind speed using surface- reflected GPS data, obtained by comparing actual and modeled waveforms, shows good agreement (within 2 m/s) with data obtained from a nearby buoy and independent wind speed measurements derived from the TOPEX/Poseidon altimetric satellite.

Komjathy, Attila↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer. respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Kline-Schoder, Robert↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting. distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receive, the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗

Velocity and Temperature Measurement in Supersonic Free Jets Using Spectrally Resolved Rayleigh Scattering

The flow fields of unheated, supersonic free jets from convergent and convergent-divergent nozzles operating at M = 0.99, 1.4, and 1.6 were measured using spectrally resolved Rayleigh scattering technique. The axial component of velocity and temperature data as well as density data obtained from a previous experiment are presented in a systematic way with the goal of producing a database useful for validating computational fluid dynamics codes. The Rayleigh scattering process from air molecules provides a fundamental means of measuring flow properties in a non-intrusive, particle free manner. In the spectrally resolved application, laser light scattered by the air molecules is collected and analyzed using a Fabry-Perot interferometer (FPI). The difference between the incident laser frequency and the peak of the Rayleigh spectrum provides a measure of gas velocity. The temperature is measured from the spectral broadening caused by the random thermal motion and density is measured from the total light intensity. The present point measurement technique uses a CW laser, a scanning FPI and photon counting electronics. The 1 mm long probe volume is moved from point to point to survey the flow fields. Additional arrangements were made to remove particles from the main as well as the entrained flow and to isolate FPI from the high sound and vibration levels produced by the supersonic jets. In general, velocity is measured within +/- 10 m/s accuracy and temperature within +/- 10 K accuracy.

Panda, J.↗

Joining of correct and incorrect DNA ends at double-strand breaks produced by high-linear energy transfer radiation in human fibroblasts

DNA double-strand breaks (DSBs) were measured within a 3.2-Mbp NotI fragment on chromosome 21 of cells of a normal human fibroblast cell line. Correct rejoining of DSBs was followed by measuring reconstitution of the original-size NotI fragment, and this was compared to total rejoining as measured by a conventional pulsed-field gel electrophoresis technique (FAR assay). After 80 Gy of particle irradiations with LETs in the range of 7-150 keV/microm, it was found that the repair kinetics was generally slower after irradiation with high-LET particles compared to X irradiation and that a larger proportion of the breaks remained unrepaired after 24 h. On the other hand, the misrejoining frequency as measured by the difference between correct and total rejoining after 24 h did not change with LET, but was approximately the same for all radiations at this dose, equal to 25-30% of the initial breaks. This result is discussed in relation to formation of chromosomal aberrations, deletion mutations and other biological end points.

NASA Discipline Radiation Health↗

The Contribution of CEOP Data to the Understanding and Modeling of Monsoon Systems

CEOP has contributed and will continue to provide integrated data sets from diverse platforms for better understanding of the water and energy cycles, and for validaintg models. In this talk, I will show examples of how CEOP has contributed to the formulation of a strategy for the study of the monsoon as a system. The CEOP data concept has led to the development of the CEOP Inter-Monsoon Studies (CIMS), which focuses on the identification of model bias, and improvement of model physics such as the diurnal and annual cycles. A multi-model validation project focusing on diurnal variability of the East Asian monsoon, and using CEOP reference site data, as well as CEOP integrated satellite data is now ongoing. Preliminary studies show that climate models have difficulties in simulating the diurnal signals of total rainfall, rainfall intensity and frequency of occurrence, which have different peak hours, depending on locations. Further more model diurnal cycle of rainfall in monsoon regions tend to lead the observed by about 2-3 hours. These model bias offer insight into lack of, or poor representation of, key components of the convective and stratiform rainfall. The CEOP data also stimulated studies to compare and contrasts monsoon variability in different parts of the world. It was found that seasonal wind reversal, orographic effects, monsoon depressions, meso-scale convective complexes, SST and land surface land influences are common features in all monsoon regions. Strong intraseasonal variability is present in all monsoon regions. While there is a clear demarcation of onset, breaks and withdrawal in the Asian and Australian monsoon region associated with climatological intraseasonal variabillity, it is less clear in the American and Africa monsoon regions. The examination of satellite and reference site data in monsoon has led to preliminary model experiments to study the impact of aerosol on monsoon variability. I will show examples of how the study of the dynamics of aerosol-water cycle interactions in the monsoon region, can be best achieved using the CEOP data and modeling strategy.

Lau, William K. M.↗

The contribution of CEOP data to the understanding and modeling of monsoon systems

CEOP has contributed and will continue to provide integrated data sets from diverse platforms for better understanding of the water and energy cycles, and for validating models. In this talk, I will show examples of how CEOP has contributed to the formulation of a strategy for the study of the monsoon as a system. The CEOP data concept has led to the development of the CEOP Inter-Monsoon Studies (CIMS), which focuses on the identification of model bias, and improvement of model physics such as the diurnal and annual cycles. A multi-model validation project focusing on diurnal variability of the East Asian monsoon, and using CEOP reference site data, as well as CEOP integrated satellite data is now ongoing. Similar validation projects in other monsoon regions are being started. Preliminary studies show that climate models have difficulties in simulating the diurnal signals of total rainfall, rainfall intensity and frequency of occurrence, which have different peak hours, depending on locations. Further more model diurnal cycle of rainfall in monsoon regions tend to lead the observed by about 2-3 hours. These model bias offer insight into lack of, or poor representation of key components of the convective,and stratiform rainfall. The CEOP data also stimulated studies to compare and contrasts monsoon variability in different parts of the world. It was found that seasonal wind reversal, orographic effects, monsoon depressions, meso-scale convective complexes, SST and land surface land influences are common features in all monsoon regions. Strong intraseasonal variability is present in all monsoon regions. While there is a clear demarcation of onset, breaks and withdrawal in the Asian and Australian monsoon region associated with climatological intraseasonal variability, it is less clear in the American and Africa monsoon regions. The examination of satellite and reference site data in monsoon has led to preliminary model experiments to study the impact of aerosol on monsoon variability. I will show examples of how the study of the dynamics of aerosol-water cycle interactions in the monsoon region, can be best achieved using the CEOP data and modeling strategy.

Lau, William K. M.↗

An Overview of the CBERS-2 Satellite and Comparison of the CBERS-2 CCD Data with the L5 TM Data

CBERS satellite carries on-board a multi sensor payload with different spatial resolutions and collection frequencies. HRCCD (High Resolution CCD Camera), IRMSS (Infrared Multispectral Scanner), and WFI (Wide-Field Imager). The CCD and the WFI camera operate in the VNIR regions, while the IRMSS operates in SWIR and thermal region. In addition to the imaging payload, the satellite carries a Data Collection System (DCS) and Space Environment Monitor (SEM).

Chandler, Gyanesh↗

Bubble measuring instrument and method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Kline-Schoder, Robert↗