Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Performance of charge-injection-device infrared detector arrays at low and moderate backgrounds

Three 2 x 64 element charge injection device infrared detector arrays were tested at low and moderate background to evaluate their usefulness for space based astronomical observations. Testing was conducted both in the laboratory and in ground based telescope observations. The devices showed an average readout noise level below 200 equivalent electrons, a peak responsivity of 4 A/W, and a noise equivalent power of 3x10 sq root of W/Hz. Array well capacity was measured to be significantly smaller than predicted. The measured sensitivity, which compares well with that of nonintegrating discrete extrinsic silicon photoconductors, shows these arrays to be useful for certain astronomical observations. However, the measured readout efficiency and frequency response represent serious limitations in low background applications.

Mckelvey, M. E.↗

High Tc superconducting IR detectors from Y-Ba-Cu-O thin films

A thin-film high-Tc superconducting multielement optical detector made of Y-Ba-Cu-O has been designed and evaluated using optical pulses from a diode laser (830 nm) and a Q-switched CO2-laser (10.6 microns). Different thin films have been tested. A laser deposited film showed the strongest response amplitude for short pulses and responded to an ultrafast, 50 ps wide pulse. Comparisons between dR/dT and response as a function of temperature indicated, however, a bolometric response.

Lindgren, M.↗

Surface Passivation of CdZnTe Detector by Hydrogen Peroxide Solution Etching

The spectral resolution of room temperature nuclear radiation detectors such as CdZnTe is usually limited by the presence of conducting surface species that increase the surface leakage current. Studies have shown that the leakage current can be reduced by proper surface preparation. In this study, we try to optimize the performance of CdZnTe detector by etching the detector with hydrogen peroxide solution as function of concentration and etching time. The passivation effect that hydrogen peroxide introduces have been investigated by current-voltage (I-V) measurement on both parallel strips and metal-semiconductor-metal configurations. The improvements on the spectral response of Fe-55 and 241Am due to hydrogen peroxide treatment are presented and discussed.

Hayes, M.↗

Near-infrared diode laser based spectroscopic detection of ammonia: a comparative study of photoacoustic and direct optical absorption methods

A photoacoustic spectroscopic (PAS) and a direct optical absorption spectroscopic (OAS) gas sensor, both using continuous-wave room-temperature diode lasers operating at 1531.8 nm, were compared on the basis of ammonia detection. Excellent linear correlation between the detector signals of the two systems was found. Although the physical properties and the mode of operation of both sensors were significantly different, their performances were found to be remarkably similar, with a sub-ppm level minimum detectable concentration of ammonia and a fast response time in the range of a few minutes.

NASA Discipline Life Sciences Technologies↗

Novel Infrared Phototransistors for Atmospheric CO2 Profiling at 2 Micron Wavelength

Two-micron detectors are critical for atmospheric carbon dioxide profiling using the lidar technique. The characterization results of a novel infrared AlGaAsSb/ InGaAsSb phototransistor are reported. Emitter dark current variation with the collector-emitter voltage at different temperatures is acquired to examine the gain mechanism. Spectral response measurements resulted in responsivity as high as 2650 A/W at 2.05 m wavelength. Bias voltage and temperature effects on the device responsivity are presented. The detectivity of this device is compared to InGaAs and HgCdTe devices.

Refaat, Tamer F.↗

Novel Infrared Phototransistors for Atmospheric CO2 Profiling at 2 microns Wavelength

Two-micron detectors are critical for atmospheric carbon dioxide profiling using the lidar technique. The characterization results of a novel infrared AlGaAsSb/ InGaAsSb phototransistor are reported. Emitter dark current variation with the collector-emitter voltage at different temperatures is acquired to examine the gain mechanism. Spectral response measurements resulted in responsivity as high as 2650 A/W at 2.05 microns wavelength. Bias voltage and temperature effects on the device responsivity are presented. The detectivity of this device is compared to InGaAs and HgCdTe devices.

Refaat, Tamer F.↗

Two-Photon-Absorption Scheme for Optical Beam Tracking

A new optical beam tracking approach for free-space optical communication links using two-photon absorption (TPA) in a high-bandgap detector material was demonstrated. This tracking scheme is part of the canonical architecture described in the preceding article. TPA is used to track a long-wavelength transmit laser while direct absorption on the same sensor simultaneously tracks a shorter-wavelength beacon. The TPA responsivity was measured for silicon using a PIN photodiode at a laser beacon wavelength of 1,550 nm. As expected, the responsivity shows a linear dependence with incident power level. The responsivity slope is 4.5 x 10(exp -7) A/W2. Also, optical beam spots from the 1,550-nm laser beacon were characterized on commercial charge coupled device (CCD) and complementary metal-oxide semiconductor (CMOS) imagers with as little as 13.7 microWatts of optical power (see figure). This new tracker technology offers an innovative solution to reduce system complexity, improve transmit/receive isolation, improve optical efficiency, improve signal-to-noise ratio (SNR), and reduce cost for free-space optical communications transceivers.

Ortiz, Gerardo G.↗

A Bottom-Up Engineered Broadband Optical Nanoabsorber for Radiometry and Energy Harnessing Applications

Optical absorbers based on vertically aligned multi-walled carbon nanotubes (MWCNTs), synthesized using electric-field assisted growth, are described here that show an ultra-low reflectance, 100X lower compared to Au-black from wavelength lamba approximately 350 nm - 2.5 micron. A bi-metallic Co/Ti layer was shown to catalyze a high site density of MWCNTs on metallic substrates and the optical properties of the absorbers were engineered by controlling the bottom-up synthesis conditions using dc plasma-enhanced chemical vapor deposition (PECVD). Reflectance measurements on the MWCNT absorbers after heating them in air to 400deg showed negligible changes in reflectance which was still low, approximately 0.022 % at lamba approximately 2 micron. In contrast, the percolated structure of the reference Au-black samples collapsed completely after heating, causing the optical response to degrade at temperatures as low as 200deg. The high optical absorption efficiency of the MWCNT absorbers, synthesized on metallic substrates, over a broad spectral range, coupled with their thermal ruggedness, suggests they have promise in solar energy harnessing applications, as well as thermal detectors for radiometry.

optical absorbers↗

A Meteoroid Handbook for Aerospace Engineers and Managers

At the beginning of the Space Age, spacecraft designers and mission planners were very concerned about meteoroids. They envisioned vehicles being ripped to pieces by streams of fast-moving space rocks, a notion promoted by the science fiction novels and movies of the time. The reality is, of course, different—the meteoroid streams that produce meteor showers are not dense by laypeople’s standards, having spatial densities of just a handful of particles per cubic kilometer, even during meteor outbursts. The ever-present, diffuse, sporadic background, which produces observed meteor rates of only 5 to 8 meteors per hour, makes up 90% of the meteoroid risk to spacecraft that spend at least a year in low Earth orbit (LEO), whereas the visually spectacular but short-lived meteor showers make up the other 10%. Still, meteoroids do pose a significant risk to spacecraft. At Earth, they can travel 12 to 72 km/s. These high speeds cause even small meteoroids to carry enormous kinetic energy, making them capable of doing serious damage to spacecraft. For example, a 1-mm-diameter meteoroid moving at 25 km/s can inflict the same damage as a bullet fired from a 0.357 Magnum pistol. An exterior wire can be severed by a 0.1-mm (100 mm) particle, a spacesuit can be penetrated by a 0.5-mm meteoroid, and an unshielded pressure wall (like the cabin of the Space Shuttle) can be perforated by centimeter-sized particles. Along with mechanical damage, meteoroids can also cause other types of spacecraft anomalies. Meteoroids can transfer their momentum to the spacecraft, which can destroy or damage equipment such as shunt resistors and charge-coupled device (CCD) detectors with a clear view of space. Meteoroid impacts can also generate plasma. The impact vaporizes material, producing a crater and an expanding plasma, which can in turn provide a conductive path for any charge accumulated on the spacecraft. This effect is thought to be responsible for the demise of a satellite in one case: the OLYMPUS communications satellite was sent tumbling out of control during the 1993 Perseid outburst, and a Perseid meteoroid strike has been posited as a possible cause (McDonnell et al. 1993; Caswell et al. 1995). Other researchers have suggested that very fast meteoroids could produce a small electromagnetic pulse capable of disrupting spacecraft function (Close et al. 2010).

Moorhead, A.↗

Using Scattered Light From Nadir Port to Aid the Terra and Aqua MODIS Reflective Solar Band Calibration

The MODIS instruments on the Terra and Aqua spacecraft employ a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) system to calibrate their reflective solar bands (RSBs), covering a spectral range from 0.4 to 2.1 µm. The UV exposure of the SD, from its sun-view port as well as the scattered light (sunlight reflected from top-of-atmosphere), has led to a wavelength dependent degradation of the SD, with larger degradation observed at shorter wavelengths. The scatter off the diffuser onto the scan mirror is in the forward direction, whereas the scatter off the diffuser onto the SDSM fold mirror is in the backward direction. Since the outgoing angles (viewed by MODIS detectors) are the same as the scheduled SD calibration, the gain derived from scattering light facilitates monitoring the dependence of the SD’s degradation on incident angles. In this paper, we present a method that uses multiple orbits over each mission to obtain a SD response to the nadir port illumination. The SD degradation estimated from the nadir port illumination is compared with the degradation derived from the sun-illuminated SD. As both Terra and Aqua spacecraft continue to drift from their nominal orbits, the SD calibration mechanism has been adapted to these drifts, especially in terms of characterizing the transmission screen function. This paper also presents the utility of this scattering light data to support the RSB calibration in the post-nominal orbit drift era of operations.

MODIS↗

Spatial-frequency response of the Limb Infrared Monitor of the Stratosphere /LIMS/ radiometer

The Limb Infrared Monitor of the Stratosphere (LIMS), an experiment on the Nimbus-7 satellite, is designed to scan the earth's limb vertically and measure spectral emission profiles of trace atmospheric gases believed to be important in processes controlling the stratospheric ozone distribution. Experiment objectives are reviewed and several analyses and measurements are described which were performed to determine the adequacy of the system for satisfying these objectives. Adequate spatial-frequency response for all the spectral channels is required to provide, through inversion of the measured limb-radiance profiles, important information about the temperature, structure, and composition of the atmosphere. From the LIMS design-model data, the MTF was calculated for the optical system, the detector field mask, the electronics, and the overall system, for each channel. The signal output performance of the instrument was predicted from the system MTF data model input radiance data for each channel. MTF measurements made on the flight sensor confirmed the analytical results. The predictions indicate that the instrument can satisfy the basic measurement objectives of the experiment.

Wilson, R. G.↗

X-ray fluorescence surface contaminant analyzer: A feasibility study

The bonding of liner material to the inner metal surfaces of solid rocket booster cases is adversely affected by minute amounts of impurities on the metal surface. Suitable non-destructive methods currently used for detecting these surface contaminants do not provide the means of identifying their elemental composition. The feasibility of using isotopic source excited energy dispersive X-ray fluorescence as a possible technique for elemental analysis of such contaminants is investigated. A survey is made of the elemental compositions of both D-6ac steel, a common construction material for the booster cases, and Conoco HD-2 grease, a common surface contamination. Source and detector choices that maximize signal to noise ratio in a Recessed Source Geometry are made. A Monte Carlo simulation is then made of the optimized device incorporating the latest available X-ray constants at the energy of the chosen source to determine the device's response to a D-6ac steel surface contained with Conoco HD-2 grease.

Eldridge, Hudson B.↗

Magellan star scanner experiences - What a long, stange trip it's been

Since its launch to Venus in 1989, the Magellan spacecraft has encountered a variety of interesting phenomena - several related to its star scanner. After much concentration, it was determined that the scanner events were due to environmental effects on the instrument - in particular, its response to solar protons and an unanticipated amount of thermal blanket dust (this dust is, in turn, generated and moved by other environmental forces). In short, while those phenomena were originally an operational nuisance, our scanner has unexpectedly shown new use as a particle and fields detector. Since its simple design makes Magellan's star scanner a good proton detector, a brief description of the charged-particle environment (particularly proton propagation) is also included. Short- and long-term trends in sensor behavior are presented, as are their correlations to the local environment. A summary of results to date is provided in the hope that these may be of help to future operations teams diagnosing similar phenomena. A summary is also given of methods found to reduce the operational impact of these phenomena.

Seale, Eric H.↗

A Helium GC/IMS for the Analysis of Extraterrestrial Volatiles in Exobiology Flight Experiments

For exobiology experiments on board spacecraft or space probes, a wide range of chemical species often must be detected and identified. The limited amount of power and space available for flight instruments severely limits the number of instruments that can be flown on any given mission. It is important then, that these experiments utilize instrumentation with universal response, so that all species of interest can be analyzed. Instrumentation to fulfill the analytical requirements of exobiology experiments has been developed utilizing Gas Chromatography - Ion Mobility Spectrometry. The Gas Chromatograph (GC) combines columns developed specifically for the complex mixtures anticipated with highly sensitive Metastable Ionization Detectors (a type of Helium Ionization Detector). To satisfy the limitations placed on resources, the Ion Mobility Spectrometer (IMS) uses the same ultra high purity helium as the GC. This GC-MS provides the analytical capability to fulfill a wide range of exobiology flight experiment applications and has been included on a proposed Discovery Mission and proposals for both Lander and Orbiter of the European Space Agency's Rosetta Comet Mission. A data base of helium IMS spectra is now being built for these future applications.

Kojiro, Daniel R.↗

Demonstrating the Error Budget for the Climate Absolute Radiance and Refractivity Observatory Through Solar Irradiance Measurements

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission addresses the need to observe highaccuracy, long-term climate change trends and to use decadal change observations as a method to determine the accuracy of climate change. A CLARREO objective is to improve the accuracy of SI-traceable, absolute calibration at infrared and reflected solar wavelengths to reach on-orbit accuracies required to allow climate change observations to survive data gaps and observe climate change at the limit of natural variability. Such an effort will also demonstrate National Institute of Standards and Technology (NIST) approaches for use in future spaceborne instruments. The current work describes the results of laboratory and field measurements with the Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) which is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO. SOLARIS allows testing and evaluation of calibration approaches, alternate design and/or implementation approaches and components for the CLARREO mission. SOLARIS also provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. Results of laboratory calibration measurements are provided to demonstrate key assumptions about instrument behavior that are needed to achieve CLARREO's climate measurement requirements. Absolute radiometric response is determined using laser-based calibration sources and applied to direct solar views for comparison with accepted solar irradiance models to demonstrate accuracy values giving confidence in the error budget for the CLARREO reflectance retrieval.

CLARREO↗

The Preflight Photometric Calibration of the Extreme-Ultraviolet Imaging Telescope EIT

This paper presents the preflight photometric calibration of the Extreme-ultraviolet Imaging Telescope (EIT) aboard the Solar and Heliospheric Observatory (SOHO). The EIT consists of a Ritchey-Chretien telescope with multilayer coatings applied to four quadrants of the primary and secondary mirrors, several filters and a backside-thinned CCD detector. The quadrants of the EIT optics were used to observe the Sun in 4 wavelength bands that peak near 171, 195, 284, and 304 . Before the launch of SOHO, the EIT mirror reflectivities, the filter transmissivities and the CCD quantum efficiency were measured and these values are described here. The instrumental throughput in terms of an effective area is presented for each of the various mirror quadrant and filter wheel combinations. The response to a coronal plasma as a function of temperature is also determined and the expected count rates are compared to the count rates observed in a coronal hole, the quiet Sun and an active region.

EIT (EXTREME-ULTRAVIOLET IMAGING TELESCOPE)↗

Response of silicon-Based Linear Energy Transfer Spectrometers

Silicon-based linear energy transfer (LET) telescope,(e. g., DOSTEL and RRMD) have recently been flown in space. LET spectra measured using tissue equivalent proportional counters show differences that need to be fully understood. A Monte Carlo technique based on: 1. radiation transport cluster intra-cascade model. 2. Landau-Vavilov distribution, 3. telescope geometry and detector coincidence & discriminator settings, 4. spacecraft shielding geometry, and 5. the external free space radiation environment, including recent albedo measurements, was developed.

Aman, A.↗

Response of Silicon-Based Linear Energy Transfer Spectrometers: Implication for Radiation Risk Assessment in Space Flights

There is considerable interest in developing silicon-based telescopes because of their compactness and low power requirements. Three such telescopes have been flown on board the Space Shuttle to measure the linear energy transfer spectra of trapped, galactic cosmic ray, and solar energetic particles. Dosimeters based on single silicon detectors have also been flown on the Mir orbital station. A comparison of the absorbed dose and radiation quality factors calculated from these telescopes with that estimated from measurements made with a tissue equivalent proportional counter show differences which need to be fully understood if these telescopes are to be used for astronaut radiation risk assessments. Instrument performance is complicated by a variety of factors. A Monte Carlo-based technique was developed to model the behavior of both single element detectors in a proton beam, and the performance of a two-element, wide-angle telescope, in the trapped belt proton field inside the Space Shuttle. The technique is based on: (1) radiation transport intranuclear-evaporation model that takes into account the charge and angular distribution of target fragments, (2) Landau-Vavilov distribution of energy deposition allowing for electron escape, (3) true detector geometry of the telescope, (4) coincidence and discriminator settings, (5) spacecraft shielding geometry, and (6) the external space radiation environment, including albedo protons. The value of such detailed modeling and its implications in astronaut risk assessment is addressed. c2001 Elsevier Science B.V. All rights reserved.

manned↗