Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “condensate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Down-to-earth studies of carbon clusters

Recent advances in supersonic beam experiments with laser-vaporization sources of clusters have provided some interesting new insights into the nature of the small clusters of carbon, and the processes through which carbon condenses. One cluster in particular, C(sub 60), appears to play a central role. It is argued that this cluster takes the shape of a soccerball: a hollow sphere composed of a shell of 60 carbon atoms connected by a lattice of hexagonal and pentagonal rings, in a pattern of overall icosahedral symmetry. Although C(sub 60) appears to be uniquely stable due to its perfect symmetry, all other even-numbered carbon clusters in the 32 to 100+ atom size range seem to favor similar closed spheroidal forms. These species are interpreted as relatively unreactive side products in condensation reactions of carbon vapor involving spiraling graphitic sheets. The prevalence of C(sub 60) in laser-vaporized carbon vapors and sooting flames suggests that it may be formed readily whenever carbon condenses. Such ready formation and extraordinary stability may have substantial astrophysical implications.

Smalley, R. E.↗

Space Station heat pipe advanced radiator element (SHARE) flight test results and analysis

The SHARE experiment, which consisted of a single 51 ft long by 1 ft wide prototypical Space Station heat pipe radiator panel, was flown aboard STS-29 in March 1989. Several problems were uncovered during the flight which limited performance. Extensive post-flight analysis has revealed that the manifold connecting the evaporator and condenser sections did not prime properly in 0-g, and that a mismatch in hydraulic diameters between the evaporator and condenser caused large bubbles to be present in the liquid channel at startup. These bubbles subsequently became trapped at the evaporator entrance, halting liquid flow and causing premature dryout of the evaporator wall grooves. The experiment did demonstrate heat pipe transport capability of up to 1572 W with near isothermality in both the evaporator and condenser for short periods of time.

Kosson, Robert↗

An analysis of lidar observations of polar stratospheric clouds

Lidar observations by Browell et al. (1990) are interpreted using single scattering calculations for nonspherical particles and aerosol microphysical calculations. Many of the lidar observations are consistent with particles containing 10 ppbv of condensed nitric acid vapor and an equivalent mass of water. The lidar observations of these Type 1 clouds identify two subtypes, whose properties are deduced. Type 1b particles are spherical, or nearly spherical, and typically have radii near 0.5 micron; Type 1a particles are not spherical, and have a spherical volume equivalent radius exceeding 1.0 micron. Several factors may cause variations in the size of the particles. The most significant factors are the cooling rate and the degree to which the air parcels cool below the condensation point. Specific examples in which cooling rate and cooling point may have led to variations in particle size are found in the Browell et al. (1990) data set. Condensation of 1 ppmm of water or less is quantitatively sufficient to account for the magnitude of the lidar backscatter observed from water ice clouds. The ice particles are not spherical in shape. The sizes of particles in water ice clouds cannot be determined because they are much larger than the wavelength of the lidar.

Toon, Owen B.↗

Radiative magnetized thermal conduction fronts

The evolution of plane-parallel magnetized thermal conduction fronts in the interstellar medium (ISM) was studied. Separating the coronal ISM phase and interstellar clouds, these fronts have been thought to be the site of the intermediate-temperature regions whose presence was inferred from O VI absorption-line studies. The front evolution was followed numerically, starting from the initial discontinuous temperature distribution between the hot and cold medium, and ending in the final cooling stage of the hot medium. It was found that, for the typical ISM pressure of 4000 K/cu cm and the hot medium temperature of 10 to the 6th K, the transition from evaporation to condensation in a nonmagnetized front occurs when the front thickness is 15 pc. This thickness is a factor of 5 smaller than previously estimated. The O VI column densities in both evaporative and condensation stages agree with observations if the initial hot medium temperature Th exceeds 750,000 K. Condensing conduction fronts give better agreement with observed O VI line profiles because of lower gas temperatures.

Borkowski, Kazimierz J.↗

Aerosol measurements in the stratocumulus project

Cloud Condensation Nuclei (CCN) and Condensation Nuclei (CN) were measured from the National Center for Atmospheric Research (NCAR) Electra throughout the marine stratocumulus project. The total particle concentration was measured with a condensation nucleus counter. The CCN were measured with the Desert Research Institute (DRI) instantaneous CCN spectrometer. This instrument simultaneously measures the concentration of aerosol active at up to 100 different critical supersaturations (Sc). This is accomplished by exposing the sample to a fixed supersaturation field and using the size of the droplets produced in this cloud chamber to deduce the Sc of the nuclei upon which they have grown. Droplet size is associated with Sc through a calibration which is accomplished by passing soluble aerosols of known size and composition through the cloud chamber. This procedure results in a calibration curve of Sc vs. droplet size. This then allows the channel number to be directly associated with Sc. Thus, number concentration vs. Sc is obtained and this is a CCN spectrum. Since the instrument operates continuously, the measurements at all Sc's are available simultaneously. Samples are drawn directly from the ambient air and data is displayed in nearly real time. Samples were integrated over times of about 10 seconds so that substantial spatial resolution is available. Calibrations were performed once or twice a day and were found to be consistent. Preliminary results are shown.

Hudson, James G.↗

Laboratory studies of refractory metal oxide smokes

Studies of the properties of refractory metal oxide smokes condensed from a gas containing various combinations of SiH4, Fe(CO)5, Al(CH3)3, TiCl4, O2 and N2O in a hydrogen carrier stream at 500 K greater than T greater than 1500 K were performed. Ultraviolet, visible and infrared spectra of pure, amorphous SiO(x), FeO(x), AlO(x) and TiO(x) smokes are discussed, as well as the spectra of various co-condensed amorphous oxides, such as FE(x)SiO(y) or Fe(x)AlO(y). Preliminary studies of the changes induced in the infrared spectra of iron-containing oxide smokes by vacuum thermal annealing suggest that such materials become increasingly opaque in the near infrared with increased processing: hydration may have the opposite effect. More work on the processing of these materials is required to confirm such a trend: this work is currently in progress. Preliminary studies of the ultraviolet spectra of amorphous Si2O3 and MgSiO(x) smokes revealed no interesting features in the region from 200 to 300 nm. Studies of the ultraviolet spectra of both amorphous, hydrated and annealed SiO(x), TiO(x), AlO(x) and FeO(x) smokes are currently in progress. Finally, data on the oxygen isotopic composition of the smokes produced in the experiments are presented, which indicate that the oxygen becomes isotopically fractionated during grain condensation. Oxygen in the grains is as much as 3 percent per amu lighter than the oxygen in the original gas stream. The authors are currently conducting experiments to understand the mechanism by which fractionation occurs.

Nuth, Joseph A.↗

Measurements in polar stratospheric clouds over Antarctica in September 1989

The results of six balloon flights at McMurdo Station, Antarctica, under varying temperature conditions, are used in a study of polar stratospheric clouds during Sept. 1989. A particle counter, with size resolution in the 0.5 micron radius region, indicates that cloud size distributions are always bimodal. Mode radii ranging from 0.05 to 0.10 microns were observed for the small particle mode, representing the sulfate layer or condensational growth enhancements of it. The data are not inconsistent with the expected increase in size with decreasing temperature of the small particle mode in the sulfate layer owing to deliquescence although this phenomenon is often masked by nitric acid trihydrate (NAT) condensation when temperatures are sufficiently low. Mode radii generally ranged from 1.5 to 3.5 micron for the large particle mode at concentrations 3 to 4 orders of magnitude lower than the small particle mode. The large particle mode, which normally comprises most of the mass, is presumably caused by NAT condensation on larger particles of the sulfate layer and indicates HNO3 mixing ratios of 1 to 5 ppbv for most of the cloud layers observed, suggesting substantial denitrification. On several occasions, distributions were observed with mode radii as high as 7 microns, and correspondingly large inferred mass, indicating water ice clouds in the 12 to 15 km region. On other occasions, absence of such clouds at very low temperatures indicated water vapor mixing ratios of less than 3 ppmv suggesting dehydration. Generally, the inferred HNO3 mixing ratios were higher in the lower stratosphere, suggesting redistribution through particle sedimentation.

Deshler, Terry↗

Nucleation and growth of HNO3-3H2O particles in the polar stratosphere

Growth of nitric acid trihydrate (NAT) particles on background stratospheric aerosols is examined for an isolated air parcel cooled at a uniform rate. During the process of nucleation, the saturation ratio of HNO3 vapor reaches a maximum value between 2 and 15, corresponding to supercooling by 1-4 K. If cooling rates exceed 0.5-1 K/day, small particles of NAT are produced. A major fraction of the available condensation nuclei is activated and removal of HNO3 by gravitational settling is slow. If cooling rates are less than 0.5-1 K/day, the number of aerosols that nucleate is reduced, leading to differential growth of large NAT particles. Observations of 5 micron radius particles in clouds at temperatures above the water frost point may reflect condensation of NAT on ice particles that fall through a column of air as it is cooled. Rapid condensation of HNO3 on ice particles is promoted by the high supersaturation attained during nucleation and maintained during subsequent cooling. This process provides a mechanism for irreversible removal of HNO3.

Wofsy, Steven C.↗

Thermal and humidity winds in outer planet atmospheres

Among the dynamical consequences of molecular weight variations due to condensation in hydrogen atmospheres is the creation of geostrophic wind variations by horizontal variations in molecular weight. In the present illustrative model, it is shown that such horizontal gradients are generated by methane condensation in the cases of the Uranus and Neptune atmospheres. As a result, the zonal wind shear is different in both magnitude and direction from the value determined while neglecting molecular weight variations. The horizontal molecular weight gradients due to condensation of minor constituents also vertically shear the zonal wind, giving rise to what may be termed the 'humidity wind'.

Sun, Zi-Ping↗

Thermal characterization of an AMTEC recirculating test cell

An alkali metal thermoelectric converter (AMTEC) recirculating test cell has been operated in order to determine the magnitudes of the primary heat losses of the cell and the value of the emissivity of the condenser surface. The energy balance included radiation losses, conductive losses, and losses due to the flow of sodium into the cell. The radiative heat flux dominated the heat loss mechanism of the cell at open circuit, and the condenser emissivity was calculated to be about 0.1. It is shown that, if this emissivity can be reduced to 0.02, then parasitic losses in an AMTEC recirculating test cell operating near peak power would be less than 40 percent of the heat required by the cell. The condenser emissivity decreases with elapsed time, resulting in improved thermal performance of the cell.

Underwood, M. L.↗

On the state of the emitter of the 3.3 micron unidentified infrared band - Absorption spectroscopy of polycyclic aromatic hydrocarbon species

Results of absorption measurements indicate that the PAH species responsible for the UIR (unidentified infrared) emission probably exist in a condensed form rather than as isolated molecules. It is shown that the peak absorption of the C-H stretch feature of vapor-phase PAHs occurs at a higher frequency than that of the condensed-phase PAHs and does not match the 3.289-micron interstellar feature. The vapor-phase experiments duplicate the phenomenon of the 3.3-micron profile simplification of PAH in KBr at elevated temperature. This confirms that the change of the profile with temperature is an intrinsic molecular effect, and is not a consequence of matrix (KBr) or condensed state interactions.

Flickinger, Gregory C.↗

Description of Liquid Nitrogen Experimental Test Facility

The Liquid Nitrogen Test Facility is a unique test facility for ground-based liquid nitrogen experimentation. The test rig consists of an insulated tank of approximately 12.5 cubic ft in volume, which is supplied with liquid nitrogen from a 300 gal dewar via a vacuum jacketed piping system. The test tank is fitted with pressure and temperature measuring instrumentation, and with two view ports which allow visual observation of test conditions. To demonstrate the capabilities of the facility, the initial test program is briefly described. The objective of the test program is to measure the condensation rate by injecting liquid nitrogen as a subcooled spray into the ullage of a tank 50 percent full of liquid nitrogen at saturated conditions. The condensation rate of the nitrogen vapor on the subcooled spray can be analytically modeled, and results validated and corrected by experimentally measuring the vapor condensation on liquid sprays.

Jurns, John M.↗

Hydrogen no-vent fill testing in a 1.2 cubic foot (34 liter) tank

Experimental results of no-vent fill testing with liquid hydrogen in a 1.2 cubic foot (34 liter) stainless steel tank are presented. More than 40 tests were performed with various liquid inlet temperatures, inlet flowrates, initial tank wall temperatures, and liquid injection techniques. Fill levels equal to or exceeding 90 percent by volume were achieved in 40 percent of the tests with the tank pressure limited to a maximum of 30 psia. Three liquid injection techniques were employed; top spray, upward pipe discharge, and bottom diffuser. Effects of each of the varied parameters on the tank pressure history and final fill level are evaluated. The final fill level is found to be indirectly proportional to the initial wall and inlet liquid temperatures and directly proportional to the inlet liquid flowrate. Furthermore, the top spray is the most efficient no-vent fill method of the three configurations examined. The success of this injection method is primarily due to condensation of the ullage vapor onto the incoming liquid droplets. Ullage condensation counteracts the tank pressure rise resulting from energy exchange between the fluid and the warmer tank walls, and ullage compression. Upward pipe discharge from the tank bottom is the next most efficient method. Fluid circulation induced by this fill configuration tends to diminish thermal stratification in the bulk liquid, thus enhancing condensation at the liquid gas interface.

Moran, Matthew E.↗

TEM studies of a circumstellar rock

Reported here is the discovery of crystals of titanium carbide in a grain of silicon carbide which formed as a circumstellar dust particle in the atmosphere of a carbon-rich star. Just as in the case of terrestrial rocks, whose assemblage of minerals gives us clues to the composition and conditions of the environment in which they formed, the titanium carbide crystals and their textural relationship to the silicon carbide give us important clues to the nature of the stellar atmosphere in which they formed. From microscopic studies of the relationships between the atomic planes of the silicon carbide and the titanium carbide, we can show that the titanium carbide cannot have existed as already-formed crystals in a gas around which silicon carbide subsequently condensed. An alternative possibility is that both minerals grew quickly and simultaneously from condensing gas in the rapidly cooling and expanding stellar atmosphere. Other microscopic features of the silicon carbide, such as abundant atomic layer disorder and crystal twinning, similarly suggest rapid grain growth. However, another possibility is that the titanium carbide grew inside of the silicon carbide by diffusion of titanium atoms. Our calculations suggest that this scenario is less likely, given the relatively short times (a year or less) for which stellar condensates can be expected to be exposed to temperatures high enough to make diffusion sufficiently rapid.

Bernatowicz, Thomas J.↗

Description of liquid nitrogen experimental test facility

The Liquid Nitrogen Test Facility is a unique test facility for ground-based liquid nitrogen experimentation. The test rig consists of an insulated tank of approximately 12.5 cubic ft in volume, which is supplied with liquid nitrogen from a 300 gal dewar via a vacuum jacketed piping system. The test tank is fitted with pressure and temperature measuring instrumentation, and with two view ports which allow visual observation of test conditions. To demonstrate the capabilities of the facility, the initial test program is briefly described. The objective of the test program is to measure the condensation rate by injecting liquid nitrogen as a subcooled spray into the ullage of a tank 50 percent full of liquid nitrogen at saturated conditions. The condensation rate of the nitrogen vapor on the subcooled spray can be analytically modeled, and results validated and corrected by experimentally measuring the vapor condensation on liquid sprays.

Jurns, J. M.↗

Mineralogy and possible origin of an unusual Cr-rich inclusion in the Los Martinez (L6) chondrite

During a petrological study of the previously unclassified ordinary chondrite Los Martinez a highly unusual Cr-rich inclusion is found which is unique in both extraterrestrial and terrestrial mineralogy. Detailed SEM and TEM studies show that the inclusion consists of a highly zoned single crystal of plagioclase intergrown with chromium-rich spinel which indicates that it is the product of exsolution. The Cr-rich precursors of the inclusion probably have close affinities to the chronite-plagioclase chrondrules observed by Ramdohr (1967) in several ordinary chondrites. Based on the zoning in the inclusion it is suggested that it is the product of fractional crystallization from a melt, which may have formed as a liquid condensate, or by melting of solid condensates, in the solar nebula. Subsequent cooling of this melt condensate resulted in crystallization of the unidentified phase. After crystallization, the inclusion was probably incorporated into a parent body where it underwent metamorphism and was probably shocked to some degree. During this period of parent body metamorphism, exsolution and decomposition of the unknown precursor occurred to produce the observed intergrowth of plagioclase and chromite. Los Martinez is classified as an L6 ordinary chondrite breccia.

Brearley, Adrian J.↗

Two-phase/two-phase heat exchanger simulation analysis

The capillary pumped loop (CPL) system is one of the most desirable devices to dissipate heat energy in the radiation environment of the Space Station providing a relatively easy control of the temperature. A condenser, a component of the CPL system, is linked with a buffer evaporator in the form of an annulus section of a double tube heat exchanger arrangement: the concentric core of the double tube is the condenser; the annulus section is used as a buffer between the conditioned space and the radiation surrounding but works as an evaporator. A CPL system with this type of condenser is modeled to simulate its function numerically. Preliminary results for temperature variations of the system are shown and more investigations are suggested for further improvement.

Kim, Rhyn H.↗

Stardust - Aggregation of cosmic dust analogues in microgravity

The condensation behavior of refractory grains near stars was investigated in an experiment which used a specially designed apparatus flown aboard NASA's Reduced Gravity aircraft. The apparatus consisted of a furnace in which a solid material (Zn or Mg) is vaporized into a temperature- and pressure-controlled chamber. Light scattered from the grains was recorded using a video system, and temperature measurements in the chamber were recorded throughout the microgravity period. The video and the temperature data are compared to models that predict the time dependence of the temperature- and vapor-pressure profiles to deduce the condensation behavior of the material. The joint U.S.-Italian program (named Stardust) for these experiments, designed to study refractory grain formation and aggregation, was set up to develop experimental and computational techniques for condensation studies under microgravity conditions.

Dell'aversana, P.↗