Scoring Morphological Change in Computed Tomography Images of Pentaerythritol Tetranitrate (PETN)
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A number of fundamental scientific questions have arisen concerning the operation of high-energy DR and CT systems. Some of these questions include: (1) How deeply can such systems penetrate thickly shielded objects? (2) How well can such systems distinguish between dense and relatively high Z materials such as lead, tungsten and depleted uranium and lower Z materials such as steel, copper and tin? (3) How well will such systems operate for a uranium material which is an intermediate case between low density yellowcake and high density depleted uranium metal? These questions have led us to develop a set of phantoms to help answer these questions, but do not have any direct bearing on any smuggling concern. These new phantoms are designed to allow a systemic exploration of these questions by gradually varying their compositions and thicknesses. These phantoms are also good probes of the blurring behavior of radiography and tomography systems. These phantoms are composed of steel ({rho} assumed to be 7.8 g/cc), lead ({rho} assumed to be 11.4 g/cc), tungsten ({rho} assumed to be 19.25 g/cc), uranium oxide (UO{sub 3}) ({rho} assumed to be 4.6 g/cc), and depleted uranium (DU) ({rho} assumed to be 18.9 g/cc). There are five designed phantoms described in this report: (1) Cylindrical shells of Tungsten and Steel; (2) Depleted Uranium Inside Tungsten Hemi-cube Shells; (3) Nested Spherical Shells; (4) UO{sub 3} Cylinder; and (5) Shielded DU Sphere.
Abstract not provided.
Explore the source record for details and available documents.
The use of the degrees of freedom for signal is proposed as a design criteria for comparing different designs for satellite and other measuring systems. It is also proposed that certain eigensequence plots be examined at the design stage along with appropriate estimates of the parameter lambda playing the role of noise to signal ratio. The degrees of freedom for signal and the eigensequence plots may be determined using prior information in the spectral domain which is presently available along with a description of the system, and simulated data for estimating lambda. This work extends the 1972 work of Weinreb and Crosby.
The use of the degrees of freedom for signal is proposed as a design criteria for comparing different designs for satellite and other measuring systems. It is also proposed that certain eigensequence plots be examined at the design stage along with appropriate estimates of the parameter lambda playing the role of noise to signal ratio. The degrees of freedom for signal and the eigensequence plots may be determined using prior information in the spectral domain which is presently available along with a description of the system, and simulated data for estimating lambda. This work extends the 1972 work of Weinreb and Crosby.
Progress in development of the methods required to study bone remodeling as a function of time is reported. The following topics are presented: 'A New Methodology for Registration Accuracy Evaluation', 'Registration of Serial Skeletal Images for Accurately Measuring Changes in Bone Density', and 'Precise and Accurate Gold Standard for Multimodality and Serial Registration Method Evaluations.'
Tomography (CT) has proved to be of inestimable use in providing a rapid evaluation of a variety of samples from Mechanics of Granular Materials (MGM) to electronic materials (Ge-Si alloys) to space grown materials such as meteorites. The system at Kennedy Space Center (KSC), because of its convenient geographical location, is ideal for examining samples before launch and immediately after returning to Earth. It also has the advantage of the choice of fluxes, and in particular the use of a radioactive cobalt source, which is basically monochromatic. This permits a reasonable measurement of density to be made from which chemical composition can be determined. Due to the current dearth of long duration space grown materials, the CT instrument has been used: (1) to characterize materials in preparation for flight, (2) to determine thermal expansion values, and (3) to examine long duration space grown materials, i.e. meteorites. This work will first describe the establishment of the protocol for obtaining the optimum density readings for any material. Included will be the effects of the hardware or instrumental parameters that can be controlled, and the techniques used to process the CT data. Examples will be given of the compositional variation along a single crystal of Ge-Si alloy. Density variation with temperature has been measured in preparation for future materials science experiments; this involved the fabrication at MSFC and installation of a single zone furnace at KSC incorporating a heat pipe to ensure high temperature uniformity. At the time of writing the thermal expansion of lead (Pb) has been measured from room temperature to 900 C. Three methods are available. Digital radiography enables length changes to be determined. Prior to melting the sample is smaller than the container and the diameter change can be measured. Most critical, however, is the density change in solid, through the melting region, and in the liquid state. These data are needed for engineering purposes to aid in the design of containment cartridges, and for enabling fluid flow calculations. A second sample, with the Pb alloyed with Sb is ready for scanning. This corresponds to the planned composition of Dr. Poirier s flight experiment. Other materials pertinent to NASA programs such as Al-Cu (Trivedi), CdTe (Banish), HgCdTe (Lehoczky) will be examined below and above the melting point. Finally, three-dimensional results will be shown of the structure of a two-phase metallic meteorite of metal and sulfide, in which the Fe-Ni phase has coarsened during slow cooling over hundreds of millions of years.
Quantitative CT (QCT) is an established method for the noninvasive assessment of bone mineral content in the vertebral spongiosum and other anatomic locations. The potential strengths of QCT relative to dual photon absorptiometry (DPA) are its capability for precise three-dimensional anatomic localization providing a direct density measurement and its capability for spatial separation of highly responsive cancellous bone from less responsive cortical bone. The extraction of this quantitative information from the CT image, however, requires sophisticated calibration and positioning techniques and careful technical monitoring.
The major morphological features - foam cells, voids, knit lines, and the bondline interface were evaluated. The features identified by micro-CT correlate well to those observed by SEM. 3D reconstructions yielded volumetric dimensions for large voids (max ~ 30 mm). Internal voids and groupings of smaller cells at the bondline are concluded to be the cause of the indications noted during the NDE prescreening process.
No abstract available
No abstract available
The Astromaterials Acquisition and Cura-tion Office at NASA's Johnson Space Center (hereafter JSC curation) is the past, present, and future home of all of NASA's astromaterials sample collections. JSC curation currently houses all or part of nine different sample collections. Our primary goals are to maintain the long-term integrity of the samples and ensure that the samples are distributed for scientific study in a fair, timely, and responsible manner, thus maximizing the return on each sample. Part of the curation process is planning for the future, thus we also perform funda-mental research in advanced curation initiatives. Ad-vanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of sample collections, or getting new results from existing sample collections [1]. As part of these ad-vanced curation efforts we are augmenting our analyti-cal facilities.
Mars sample return presents unique challenges for the clean collection, containment, curation and processing of samples. The related issues of life detection and Planetary Protection are of particular importance when developing successful strategies for the acquisition and handling of Mars returned samples. In order to achieve the Mars Sample Return (MSR) science goals, reliable analyses will depend on overcoming some challenging signal/noise-related issues, such that sparse Martian organic compounds will need to be reliably analyzed against the contamination background arising from the complicated MSR campaign. Reliable analyses will depend on clean acquisition, as well as robust documentation of all aspects of both the development and management of the cache.
No abstract available
The Mars 2020 rover mission will collect and cache samples from the martian surface for possible retrieval and subsequent return to Earth. Mars Returned Samples may provide definitive information about the presence of organic compounds that could shed light on the existence of past or present life on Mars. Post-mission analyses will depend on the development of a set of reliable sample handling and analysis procedures that cover the full range of materials which may or may not contain evidence of past or present martian life [1].
Shergottites comprise most of the Martian meteorites and have a mafic to ultramafic bulk composition and a diversity of igneous textures [1].Olivine-phyric and poikilitic shergottites are sub-classes of shergottites and characterized by having a crystal cargo of large mafic minerals. Olivine-phyric shergottites have porphyritic textures of large olivinemegacrysts set in a fine-grained groundmass of pyroxene and maskelynite [2]. The poikilitic shergottites have assemblages of olivine chadocrysts poikilitically-enclosed by cm-sized pyroxene oikocrysts set in a coarse-grained groundmass of olivine and maskelynite [3,4]. The large crystal cargos in these samples are some of the first minerals to crystallize from their respective parent melts and have been extensively studied to understand shergottite petrogenesis. For instance, compositions of early-formed olivine and pyroxene in equilibrium with other phases (e.g. spinels) are used to establish depths, temperatures, and redox conditions of crystallization. There is increasing agreement that olivine megacrysts and poikilitic assemblages formed at or near the crust – mantle boundary (~85 km) before entrainment, ascent, and complete crystallization at or near the surface [1,3,4,6,7,8,9]. Additionally, linear olivine megacryst crystal size distribution (CSD)patterns and observations of polyhedral morphologies[8,9,10] are commonly interpreted to reflect steady-state crystallization under equilibrium conditions. However, oscillatory phosphorus zonation patterns in olivine from many samples indicate fluctuations in growth rates[10,12]. Recent studies measuring dendritic phosphorus zonation in terrestrial olivines [13] and experimental studies measuring how undercooling (undercooling is defined as the liquidus temperature minus the temperature being considered) controls changes in olivine morphology [14] have questioned the canonical view that large olivine megacrysts grow slowly and concentrically under equilibrium conditions. Here we present X-ray CT results from olivine-phyric and poikilitic shergottites that challenge the notion that early-formed minerals grew slowly under equilibrium conditions.