Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computational fluid dynamics simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Development of an Efficient Conjugate Heat Transfer Modeling Framework to Optimize Mixing-Limited Combustion of Ethanol in a Diesel Engine

Mixing controlled combustion of alcohol fuels has been identified as a promising technology based on their low propensity for particulate and NOx production, but the higher heats of vaporization and auto-ignition temperatures of these fuels make their direct use in diesel engine architectures a challenge. To realize the potential of alcohol-fueled combustion, a computational fluid dynamics (CFD) modeling framework is developed, validated, and exercised to identify designs that maximize engine thermal efficiency. To evaluate the use of thermal barrier coatings (TBCs), a simplified one-dimensional (1D) conjugate heat transfer (CHT) modeling framework is employed. The addition of the 1D CHT model only increases the computational expense by 15% relative to traditional approaches, yet offers more accurate heat transfer predictions over constant temperature boundary conditions. The validated model is then used to explore a range of injector orientations and piston bowl geometries. Using a design of experiments (DoE) approach, several designs were identified that improved fuel-air mixing, shortened the combustion duration, and increased thermal efficiency. The most promising design was fabricated and tested in a Caterpillar 1Y3700 single-cylinder oil test engine (SCOTE). Engine testing confirmed the findings from the CFD simulations and found that the co-optimized injector and piston bowl design yielded over 2-percentage point increase in thermal efficiency at the same equivalence ratio (0.96) and over 6-percentage point increase at the same engine load (10.1 bar indicated mean effective pressure (IMEP)), while satisfying design constraints for peak pressure and maximum pressure rise rate.

Magnotti, Gina M.↗

Conjugate Heat Transfer Modeling of Salt-Filled Fuel Pins for Stable Salt Reactor Safety Analysis

The Stable Salt Reactor (SSR) combines the proven structural design of light water reactor fuel assemblies with the inherent safety and fuel-cycle advantages of molten salt technology. In its fast reactor configuration, the SSR utilizes recycled nuclear waste as fuel, sealed within narrow salt-filled fuel pins and cooled by a surrounding liquid salt coolant. Reliable transfer of heat from the molten fuel salt through the cladding to the external coolant is essential for both reactor safety and performance. This work investigates conjugate heat transfer (CHT) in the SSR’s salt-filled fuel pins using NekRS, a high-fidelity spectral element computational fluid dynamics (CFD) solver. The analyses capture internal natural convection within the molten fuel salt and external forced convection in the coolant, under steady-state and transient operating conditions. Parametric studies evaluate how variations in reactor power and coolant flow rate influence heat transfer distributions and system response. The high-fidelity CFD results are time-averaged and post-processed for direct comparison with moderate-fidelity Reynolds-averaged Navier–Stokes (RANS) models, and for the development of reduced-order models within the SAM system code. These validated models support fast-running safety analyses of normal and off-normal transients, improving predictive capability for key safety margins. By integrating advanced CFD with system-level safety tools, this study strengthens the modeling framework for SSR design, reduces uncertainty in molten salt CHT simulations, and accelerates the engineering and licensing of next-generation nuclear reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Resistive hose modes in tokamak runaway electron beams

Beams of energetic runaway electrons are generated during disruptions in tokamaks, and fluid models are used to study their effects on macroscale dynamics. Linear computations of a massless, runaway electron beam coupled to MHD plasma show that resistive hose instabilities grow faster than tearing modes at large resistivity. Eigenvalue results with reduced models of the resistive hose instability are compared with results from the full MHD and beam system, showing that the resistive hose decouples from any plasma response. An estimate of plasma temperature at which growth of the resistive hose dominates tearing for post-disruption DIII-D plasma parameters is in a physically relevant regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coupled Monte Carlo and thermal-hydraulics modeling of a prismatic gas reactor fuel assembly using Cardinal

Cardinal is a MOOSE application that couples OpenMC Monte Carlo transport and NekRS computational fluid dynamics to the MOOSE framework, closing the neutronics and thermal-fluid gaps in conducting tightly-coupled, high-resolution multiscale and multiphysics analyses. By leveraging MOOSE's interfaces for wrapping external codes, Cardinal overcomes many challenges encountered in earlier multiphysics coupling works, such as file-based I/O or overly-restrictive geometry mapping requirements. In this work, we leverage a subset of the multiphysics interfaces in Cardinal to perform coupling of OpenMC neutron transport, MOOSE heat conduction, and THM thermal-fluids for steady-state modeling of a prismatic gas reactor fuel assembly.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Direct comparison of gyrokinetic and fluid scrape-off layer simulations

Typically, fluid simulations are used for tokamak divertor design. However, fluid models are only valid if the scrape-off layer (SOL) is highly collisional. This assumption is valid in many present-day experiments but is questionable in the upstream SOL of some high-power scenarios envisioned for burning plasmas and fusion pilot plants. This paper reports on comparisons between fluid and kinetic simulations of the SOL for upstream parameters and geometry representative of the Spherical Tokamak for Energy Production fusion pilot plant. The SOLPS-ITER (fluid) and Gkeyll (gyrokinetic) codes are operated in a two-dimensional axisymmetric mode, which replaces turbulence with ad-hoc diffusivities. In kinetic simulations, we observe that the ions in the upstream SOL experience significant mirror trapping. This substantially increases the upstream temperature and has important implications for impurity dynamics. We show that the mirror force, which is excluded in SOLPS’s fluid equations, enhances the electrostatic potential drop along the field line in the SOL. We also show that the assumption of equal main ion and impurity temperatures, which is made in commonly used fluid codes, is invalid for the regimes explored here. The combination of these effects results in superior confinement of impurities to the divertor region in kinetic simulations, consistent with our earlier predictions [Kotschenreuther et al., in 29th IAEA 29 Fusion Energy Conference (IAEA, London, UK, 2023)]. This effect can be dramatic, reducing the midplane impurity density by orders of magnitude. These results indicate that in lower collisionality SOL’s the tolerable downstream impurity densities may be higher than would be predicted by fluid simulations, allowing for higher radiated power while avoiding unacceptable core contamination. Our results highlight the importance of kinetic simulations for divertor design and optimization for fusion pilot plants.

Computational fluid dynamics↗

First principles simulation of reacting hypersonic flow over a blunt wedge

This article presents molecular-level analysis of a reactive, near-continuum, Mach 21 nitrogen flow over a blunt wedge using the direct molecular simulation (DMS) method. The flow conditions lead to internal energy excitation and dissociation in the flow field, resulting in thermal and chemical nonequilibrium in the flow. Thermal nonequilibrium in the vibrational mode is observed to extend to the molecular level, where the vibrational energy distributions at various points in the flow field are observed to be non-Boltzmann. Furthermore, this is the first reactive DMS calculation where the wall is assumed to be isothermal and full momentum accommodation of the particles is enforced, hence incorporating viscous wall effects. Since the DMS method uses a quantum mechanically generated interaction potential as its only modeling input, all thermochemical and transport properties of the flow field can directly be attributed to the ab initio potential energy surface. Using the DMS solution as a benchmark, this article assesses the performance of Navier–Stokes computational fluid dynamics solutions using lower fidelity two-temperature models. Two models are chosen as points of comparison: the well-known Park two-temperature model and the recently developed modified Marrone and Treanor model.

Mechanics↗

Deep Learning Approaches to Surrogates for Solving the Diffusion Equation for Mechanistic Real-World Simulations

In many mechanistic medical, biological, physical, and engineered spatiotemporal dynamic models the numerical solution of partial differential equations (PDEs), especially for diffusion, fluid flow and mechanical relaxation, can make simulations impractically slow. Biological models of tissues and organs often require the simultaneous calculation of the spatial variation of concentration of dozens of diffusing chemical species. One clinical example where rapid calculation of a diffusing field is of use is the estimation of oxygen gradients in the retina, based on imaging of the retinal vasculature, to guide surgical interventions in diabetic retinopathy. Furthermore, the ability to predict blood perfusion and oxygenation may one day guide clinical interventions in diverse settings, i.e., from stent placement in treating heart disease to BOLD fMRI interpretation in evaluating cognitive function (Xie et al., 2019; Lee et al., 2020). Since the quasi-steady-state solutions required for fast-diffusing chemical species like oxygen are particularly computationally costly, we consider the use of a neural network to provide an approximate solution to the steady-state diffusion equation. Machine learning surrogates, neural networks trained to provide approximate solutions to such complicated numerical problems, can often provide speed-ups of several orders of magnitude compared to direct calculation. Surrogates of PDEs could enable use of larger and more detailed models than are possible with direct calculation and can make including such simulations in real-time or near-real time workflows practical. Creating a surrogate requires running the direct calculation tens of thousands of times to generate training data and then training the neural network, both of which are computationally expensive. Often the practical applications of such models require thousands to millions of replica simulations, for example for parameter identification and uncertainty quantification, each of which gains speed from surrogate use and rapidly recovers the up-front costs of surrogate generation. We use a Convolutional Neural Network to approximate the stationary solution to the diffusion equation in the case of two equal-diameter, circular, constant-value sources located at random positions in a two-dimensional square domain with absorbing boundary conditions. Such a configuration caricatures the chemical concentration field of a fast-diffusing species like oxygen in a tissue with two parallel blood vessels in a cross section perpendicular to the two blood vessels. To improve convergence during training, we apply a training approach that uses roll-back to reject stochastic changes to the network that increase the loss function. The trained neural network approximation is about 1000 times faster than the direct calculation for individual replicas. Because different applications will have different criteria for acceptable approximation accuracy, we discuss a variety of loss functions and accuracy estimators that can help select the best network for a particular application. We briefly discuss some of the issues we encountered with overfitting, mismapping of the field values and the geometrical conditions that lead to large absolute and relative errors in the approximate solution.

60 APPLIED LIFE SCIENCES↗

Progress on Computational Modeling of Water-Based NSTF (FY2021)

This report documents the FY21 progress and achievements made in the computational analyses of the water-based NSTF. Both system-level and high-fidelity Computational Fluid Dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. The progress on the waterbased NSTF experimental testing is summarized in a companion report (ANL-ART-230). As a continuation of progress from previous years, in FY21 the RELAP5 model of the NSTF was first updated to include a representative heated cavity that incorporated convection and conduction means of heat transfer. Two different cavity models were developed, one that models the radiation heat exchange among all surfaces in one enclosure (Cavity Model 1), and another that employs multiple radiation enclosures with each considering the surfaces at one axial level (Cavity Model 2). This updated RELAP5 deck was benchmarked with single-phase test data to tune form loss coefficients of the elbows and tees, along with heat transfer coefficients within the cavity and off the external insulation panels. This tuned model was then found to accurately predict fluid temperatures within 2.5% and both system and riser flow rates within 6% during single-phase, steady-state simulations. For transient simulations, there is a slight over prediction of the flow rate, fluid temperatures, and heater temperatures during the heat-up period, which indicate that the transient heat loss may be underestimated. Following, the capabilities of RELAP5-3D were examined, which feature a conduction enclosure model that is not present in the current version of RELAP5-MOD3.3 used for all previous NSTF simulations. As an initial comparison of the two codes, single-phase simulations were run that used similar input decks. The results indicate that the single-phase flow predicted by the two codes was very similar, however RELAP5-3D appears to predict a higher system flow during the two-phase transient when compared to the flow rates predicted by RELAP5-MOD3.3. Furthermore, RELAP5-3D run did not capture the density wave oscillations or geysering phenomena, which are large oscillation flow instabilities observed in the experimental facility. To further the prediction capabilities for capturing two-phase instabilities, Options 55, 57, 58, 61, which are implemented by default in RELAP5-MOD3.3 but not in RELAP5-3D, were investigated. When enabling Option 61, RELAP5-3D agrees well with MOD3.3 in predicting the total system flow, while other options have negligible effect on the predicted total system flow by RELAP5-3D. However, none of these options enables RELAP5-3D to produce the same flow instabilities. For future steps, efforts are currently underway to investigate RELAP5-3D’s different behavior in predicting low-pressure two-phase instabilities. STAR-CCM+ was used to perform CFD analysis of the water-based test facility and provide simulation results for comparisons to experimental data. Efforts first focused on describing the characteristics of flow within the heated cavity. A study was performed on whether possible leakage flow between the two sides of the cavity could substantially impact and explain the results. An additional second assumption was examined which defined adiabatic side walls, so physical insulation structures were added to the models to allow conduction across this outer insulation. The results suggest that potential porosity of the insulation could be a major factor in the temperature distribution within the cavity and should be considered in any studies where it is desirable to know the cavity wall temperatures to higher accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Numerical Simulations of Cryogenic Hydrogen Cooling in Vortex Tubes with Smooth Transitions

Improving efficiency of hydrogen cooling in cryogenic conditions is important for the wider applications of hydrogen energy systems. The approach investigated in this study is based on a Ranque-Hilsch vortex tube (RHVT) that generates temperature separation in a working fluid. The simplicity of RHVT is also a valuable characteristic for cryogenic systems. In the present work, novel shapes of RHVT are computationally investigated with the goal to raise efficiency of the cooling process. Specifically, a smooth transition is arranged between a vortex chamber, where compressed gas is injected, and the main tube with two exit ports at the tube ends. Flow simulations have been carried out using STAR-CCM+ software with the real-gas Redlich-Kwong model for hydrogen at temperatures near 70 K. It is determined that a vortex tube with a smooth transition of moderate size manifests about 7% improvement of the cooling efficiency when compared vortex tubes that use traditional vortex chambers with stepped transitions and a no-chamber setup with direct gas injection.

08 HYDROGEN↗

Deep learning for in situ data compression of large turbulent flow simulations

As the size of turbulent flow simulations continues to grow, in situ data compression is becoming increasingly important for visualization, analysis, and restart checkpointing. For these applications, single-pass compression techniques with low computational and communication overhead are crucial. In this paper we present a deep-learning approach to in situ compression using an autoencoder architecture that is customized for three-dimensional turbulent flows and is well suited for contemporary heterogeneous computing resources. The autoencoder is compared against a recently introduced randomized single-pass singular value decomposition (SVD) for three different canonical turbulent flows: decaying homogeneous isotropic turbulence, a Taylor-Green vortex, and turbulent channel flow. Our proposed fully convolutional autoencoder architecture compresses turbulent flow snapshots by a factor of 64 with a single pass, allows for arbitrarily sized input fields, is cheaper to compute than the randomized single-pass SVD for typical simulation sizes, performs well on unseen flow configurations, and has been made publicly available. The results reported here show that the autoencoder dramatically outperforms a randomized single-pass SVD with similar compression ratio and yields comparable performance to a higher-rank decomposition with an order of magnitude less compression in regard to preserving a number of important statistical quantities such as turbulent kinetic energy, enstrophy, and Reynolds stresses.

97 MATHEMATICS AND COMPUTING↗

Accurate and efficient predictions of keyhole dynamics in laser materials processing using machine learning-aided simulations

The keyhole phenomenon has been widely observed in laser materials processing, including laser welding, remelting, cladding, drilling, and additive manufacturing. Keyhole-induced defects, primarily pores, dramatically affect the performance of final products, impeding the broad use of these laser-based technologies. The formation of these pores is typically associated with the dynamic behavior of the keyhole. So far, the accurate characterization and prediction of keyhole features, particularly keyhole depth, as a function of time, has been a challenging task. In situ characterization of keyhole dynamic behavior using the synchrotron X-ray technique is informative but complicated and expensive. Current simulations are generally hindered by their poor accuracy and generalization abilities in predicting keyhole depths due to the lack of accurate laser absorptance data. In this study, we develop a machine learning-aided simulation method that accurately predicts keyhole dynamics, especially in keyhole depth fluctuations, over a wide range of processing parameters. In two case studies involving titanium and aluminum alloys, we achieve keyhole depth prediction with a mean absolute percentage error of 10 %, surpassing those simulated using the ray-tracing method with an error margin of 30 %, while also reducing computational time. This exceptional fidelity and efficiency empower our model to serve as a cost-effective alternative to synchrotron experiments. Our machine learning-aided simulation method is affordable and readily deployable for a large variety of materials, opening new doors to eliminate or reduce defects for a wide range of laser materials processing techniques.

Computational fluid dynamics↗

Reduced Order Model to Predict Dispersion of Flammable Refrigerant into a Space

As the HVAC&R industry mobilizes to deploy more low-GWP refrigerants, relevant standards are being continually reviewed and updated. Those include the general safety standards ISO 5149 and ASHRAE 15, and the equipment standards IEC and UL. The standards systematically set the allowable maximum amount of refrigerant that should be used in different equipment types and different applications. To do so, they rely on predictions of how a leaked refrigerant mass will disperse into a space. Dispersion characteristics, such as total flammable volume and its residence time, determine the risk associated with the presence of the flammable refrigerant. The standards have included provisions for the use of flammable refrigerants for approximately two decades. They relied on limited analytical analyses and test cases in their development. Dispersion of a refrigerant into a space is complex. Computational fluid dynamics (CFD) are the most accurate in predicting a given problem. However, CFD is computationally expensive and requires specialized expertise and resources and is not suitable for use by standards development working group as prediction tool. This paper presents the development of a reduced order model (ROM) that predicts the key dispersion characteristics relevant to the dispersion of a leaked refrigerant into a space for any combination of input variables. The inputs are the refrigerant release height, the total released refrigerant mass and its release flow rate, the refrigerant molecular weight, the ventilation flow rate, the floor area and height of the space, recirculation air flow rate, and the tightness of the space. The outputs are histograms of volume fraction of the room in prescribed concentration bins and the total mass of the refrigerant in each bin normalized by the total refrigerant charge at 13 prescribed simulation time stamps between 1 and 900 seconds. The ROM is constructed from a set of CFD simulations with carefully chosen combinations of input parameters. The selection if done using a multidimensional sparse grid which is a generalization of the classical tensor approach but offers additional flexibility and thus can be more carefully tuned towards a specific model. The tuning is done to improve the accuracy, measured in the difference between the output values of the ROM and the CFD model, while minimizing the computational cost, measured in number of CFD simulations which is orders of magnitude more expensive than the processing the training data.

Edwards, Dean↗

Assessment of Sodium Thermal Stratification Models Utilizing the TSTF Benchmark

As a result of certain transient scenarios, a thermally stratified layer of liquid sodium can develop in the bulk coolant volumes of a sodium-cooled fast reactor (SFR). In addition to the effects a stratification layer has on the temperature of the heat transport system, a stratification layer can also influence the transition to and establishment of natural circulation flow, which plays an important role in passive cooling and the inherent safety of a pool-type SFR. Therefore, the ability to accurately capture thermal stratification phenomena is important when demonstrating the safety basis of a pool-type SFR during transient sequences. The present work assesses various computational models with different fidelities in their ability to predict thermal stratification in the upper plenum of an SFR. Each computational model will be assessed using the data generated at the Thermal Stratification Test Facility (TSTF) located at the University of Wisconsin-Madison. Using measured flow rate and inlet temperature data, the measured temperature distributions of the tests are compared to the predictions of the lumped volume-based models in SAS4A/SASSYS-1, a 1D-based model in SAM, and a 3-D computational fluid dynamics (CFD) model using STAR-CCM+. The relative performance of the various computational methods is assessed with respect to key metrics such as bulk coolant temperature distribution and plenum exit temperature. A total of eight tests are analyzed, covering different combinations of flow rates (3 and 10 GPM) and upper internal structure (UIS) configurations (none, solid, porous, and open) The perfect mixing model of SAS4A/SASSYS-1 provides the highest accuracy when the flow rate is high and there is no UIS in the test vessel, as high flow rate injection promotes thermal mixing of the sodium in the test vessel. For most of the analyzed tests, the stratified volume model of SAS4A/SASSYS-1 is able to predict the delay in the outlet temperature drop and temperature distribution in the test vessel by a small number of layers to represent thermal stratification. However, the stratified volume model can only simulate a maximum of three temperature layers within a volume and when a layer approaches the elevation of the outlet, the predicted outlet temperature can demonstrate rapid, non-physical changes. The 1-D axial mixing model of SAM provides results that agree reasonably well with the measured data in the prediction of the temporal evolution of the outlet temperature with the exception of the case with a high flow rate and no UIS. The SAM 1-D model has a similar level of accuracy to CFD results when it comes to predicting the outlet temperature. CFD shows overall good agreement in predicting the temperature distribution in the test vessel and outlet temperature. As CFD can model the test vessel geometry in detail, it performs well in the cases of complex geometries such as tests that included a UIS and internal flow through the UIS resulting in active mixing of the coolant in the test vessel. Each of the models discussed in the present work has the potential to be useful during the various stages of reactor design, analysis, and licensing. The lumped-volume approach can be applied for fast turnaround safety calculations to obtain overall reactor behavior during transients. The 1-D models provide improved accuracy when stratification is expected for a relatively low increase in the computational cost. The CFD model can be utilized for confirmatory analysis of the 1-D model, when experimental measurements are not available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance and Accuracy Implications of Parallel Split Physics-Dynamics Coupling in the Energy Exascale Earth System Atmosphere Model

Simultaneous calculation of atmospheric processes is faster than calculating processes one at a time. This type of parallelism is beneficial or perhaps even necessary to provide good performance on modern supercomputers, which achieve faster performance through increased processor count rather than improved clock speed. The scalability of the Energy Exascale Earth System Model (E3SM) Atmosphere Model (EAM) is limited by the fluid dynamics which scales up to the number of mesh cells in the global mesh. In contrast, the suite of physics parameterizations in EAM is scalable up to the total number of physics columns, which is an order of magnitude greater than the number of mesh cells. A proposed solution to unlocking the greater potential performance from the physics suite is to solve the physics and dynamics in parallel. This work represents a first attempt at parallel splitting of the grid-scale fluid dynamics model and the subgrid-scale physics parameterizations in a global atmosphere model. We will demonstrate that switching to parallel physics-dynamics coupling extends the scalability of the EAM to up to 3 times the previous peak scalability limit and is up to 20% faster than the sequentially split coupling at the highest core counts and the same time step. Decadal simulations of both coupling approaches show very little impact to the model climate. This improved performance does not come without drawbacks, however. Parallel splitting requires a shorter time step and other modifications which largely offset performance gains. A mass fixer is required for conservation. Techniques for mitigating these issues are also discussed.

97 MATHEMATICS AND COMPUTING↗

Analysis of HolosGen Sub-Scale Simulator with Plant Dynamics Code

The Subcritical Power Module Sub-scale Simulator (SPM-SS) has been designed and constructed by HolosGen LLC under the ARPA-E MEITNER program to simulate the thermal-hydraulic and heat transfer behavior of the full-scale Holos-Quad Subcritical Power Modules (SPMs). Four coupled SPMs, each rated at 5.5MW, form the Holos-Quad gas-cooled microreactor design. The SPM-SS represents a substantially scaled-down system with a power rating less than 40 kW, equipped with an electrically heated fuel cartridge heat exchanger, an electrically heated compressor heat exchanger, and a valve actuated turbine heat exchanger, in addition to a recuperator and a cooler heat exchanger. The fuel cartridge represents a portion of the full-scale SPM core, the compressor heat exchanger mimics the temperature changes resulting from the compressor’s turbomachinery inefficiencies, the turbine heat exchanger mimics the expansion process normally occurring through the turbine, while the recuperator and cooler heat exchangers complete the subscale simulator loop. The heaters equipping the fuel cartridge and the compressor heat exchangers are electronically controlled to simulate normal and off-normal SPM operating conditions. The full-scale Holos-Quad SPM design eliminates the traditional balance of plant and executes thermal-to-electric energy conversion by means of an intercooled Brayton cycle with decoupled compressor-turbine turbomachinery. The Holos-Quad full-scale design is equipped with a multi-stage axial Low- and High-Pressure compressor, and a multistage axial turbine. The SPM-SS is designed for testing and validation of selected components which are instead coupled by a traditional balance of plant. The SPMSS is not equipped with turbo-machinery (compressor and turbine) as the development of these components were excluded from the scope of work under the ARPA-E MEITNER funding program. The SPM-SS balance of plant enables modifications, replacement and testing of individual components with different working fluids and is designed to include the turbo-machinery components that will be developed in future research . The SPM-SS can be operated with different gases, variable mass-flow-rates, pressures, and temperatures to obtain test data for selected components, whose performance can be scaled to validate the computer model of the full-scale SPM at various conditions (e.g., start-up, transients conditions). The SPM-SS can operate at the maximum Holos-Quad design pressure of 7 MPa, and a maximum temperature limited to 650 °C by the electrical heaters. Several SPM-SS tests have been conducted and analyzed with the Plant Dynamics Code (PDC) developed at the Argonne National Laboratory (ANL). These tests aimed at validating the PDC modeled predictions of the full-scale Holos-Quad design with data from selected SPM-SS components. In order to address SPM-SS specific characteristics, such as components heat losses and absence of turbomachinery components, some modifications to the PDC have been implemented to factor the design differences from the full-scale Holos-Quad SPM to the SPM-SS. As the PDC offers capabilities to analyze systems with different working fluids, air, nitrogen, and helium were utilized as the SPM-SS working fluids. Air was utilized to fine-tune the SPM-SS Systems Structures and Components (SSCs), nitrogen was utilized to pressure test the SPM-SS loop at the SPMs design maximum pressure of 7MPa. Helium was utilized as the working fluid circulating through the SPM-SS SSCs for specific tests to validate the PDC predictions of the fuel cartridge heat exchanger. SPM-SS tests data were also analyzed with both the steady-state and transient analysis capabilities offered by the PDC. This report describes the PDC analysis of the SPM-SS tests data, including the necessary code modifications and comparison of the code results with the experimental data. Based on the results, a discussion is presented on how the analysis supports design and transient calculations of the full-scale Holos-Quad microreactor. Also based on the results of this work, recommendations are made for future optimizations of the SPM-SS components and PDC model development needs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Hydraulic Experimental Test Article - Fiscal Year 2023 (Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. To date a test matrix has been completed utilizing the primary system of THETA. These tests, along with computational fluid dynamics and systems code models, determined the heat transfer across the core barrel and intermediate heat exchanger outlet was too great to effectively represent scaled thermal hydraulic phenomena of a liquid metal cooled reactor. Therefore, a significant effort was made to remove the primary system from the METL 28” test vessel #4 and clean the residual sodium from the primary system to facilitate upgrades. Thermal insulation was then incorporated in the core barrel and intermediate heat exchanger outlets. The primary system was then replaced, and a series of tests were performed to assess the performance of the thermal insulation. With primary system testing and upgrades complete, the secondary system could then be brought online. The tube side of the shell-and-tube intermediate heat exchanger was installed onto the primary system flange to begin installing the secondary system. The support structure for the secondary system was then erected on the METL mezzanine alongside the THETA primary system to facilitate installation of the secondary system components (sodium-to-air heat exchanger, flowmeter and pump). The piping and expansion tank were welded into the secondary system. Non-destructive examination of the secondary system welds was completed in order to satisfy ASME B31.3 pipe code for class M process fluids. The heating system and insulation were then added to prepare the system to be filled with sodium. The ancillary electrical equipment was installed which included the pump control box, blower VFD, pipe heater control system, etc. The secondary system will be filled, and a test matrix will be completed in early FY2024.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Capability in Theory, Modeling, and Validation for a Range of Innovative Fusion Concepts using High-Fidelity Moment-Kinetic Models

A computational modeling capability is created and available to the fusion community to understand and design lower-cost and innovative fusion concepts. The approach uses high- fidelity kinetic, moment-kinetic, and moment models and includes sophisticated plasma- boundary interactions. A majority of fusion-relevant simulations are performed with magnetohydrodynamic models and hybrid particle-in-cell codes, with limited-fidelity electron and kinetic physics. However, in fusion configurations like Z-pinches, field-reversed- configurations, plasma jet magneto-inertial fusion, spinning mirrors, and others, kinetic effects (both electron and ions) are critical to understand the physics and design scaling into the highly kinetic regime of a burning fusion plasma. Furthermore, as present fusion machines move towards a burning plasma regime, liquid-metal blankets are needed to handle first-wall heat- flux, reduce erosion, and eventually for energy conversion and fuel breeding. The work performed under this ARPA-E BETHE Capability Team advances the state-of-the-art in modeling and understanding plasma dynamics in fusion devices and its coupling with liquid-metal dynamics. These are critical areas of research for fusion energy to become realizable. To address these complex problems, we have leveraged and extended computational capabilities through the code, Gkeyll (developed jointly with Princeton Plasma Physics Laboratory and academic partners), for kinetic and moment modeling of fusion plasmas. The Concept Teams supported by this Capability Team include the Wisconsin High-field Axisymmetric Mirror (WHAM), Centrifugal Mirror Experiment (CFME), Plasma-Jet Magneto- Inertial Fusion (PJMIF), and solid and liquid wall plasma-material interaction studies relevant to a number of fusion concepts including Zap Energy’s Z-pinch. This software is open-source and available to the fusion community as a high-fidelity tool for the design of lower-cost fusion experiments. 3D gyrokinetic simulations of WHAM are now possible for long enough time scales to understand the evolution of interchange instabilities. 3D multi-fluid simulations of CMFE at higher Mach numbers are now possible for detailed design iterations with the goal of stability. The state-of-the-art in understanding shock formation and shock mitigation regimes in merging liners for PJMIF have been furthered by our kinetic simulations. Our novel models and frameworks studying plasma-material interaction by incorporating wall emission for various solid wall materials of relevance to pulsed and steady fusion concepts have advanced the state-of-the-art in our understanding of particle fluxes, heat fluxes, and other quantities at cathodes and anodes. The results from this work may explain discrepancies between experimental and theoretical predictions of achieved current densities in pulsed concepts such as Z-pinches. Another significant contribution of this Capability Team is the development and deployment of a novel experimental platform, LEX (Liquid Electrode eXperiment), at Virginia Tech to understand liquid metal free-surface response to electromagnetic pulses. The novel experiments along with model validation quantified the effect of different materials and sizes of liquid metal droplets on the radiative power balance of fusion plasmas for pulsed concepts. Furthermore, these experiments provided mitigation strategies for violent liquid metal response for high current pulses as would be expected in fusion regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal design analysis for SuperTruck II lithium-titanate battery pack

Here, this paper presents a systematic thermal management analysis for a new lithium-titanate-oxide battery pack to be installed in a SuperTruck II, Class 8 hybrid truck. The authors investigate the feasibility of mounting the battery pack inside the vehicle and air-cooling it with fans supplying conditioned air from the cabin. Moreover, the cells within each module are to be immersed in a heat-transfer fluid to improve temperature homogeneity. A multi-stage thermal analysis is performed to ensure adequate thermal regulation of the battery under the proposed design, considering installation and operational constraints. The authors perform thermal and electrical characterization tests on a single cell. Results inform the development of computational fluid dynamics models of the cells, modules, and pack. Module-level analysis shows that the cell temperatures can be maintained below their upper operational limit of 55 °C with module wall-to-air heat transfer coefficients between 10 and 20 Wm -2 K -1 . Pack-level analysis of distinct configurations determines effective airflow paths for adequate heat transfer and delivers a final battery pack design that achieves sufficient cooling and temperature uniformity. A reduced-order electrothermal model is developed to rapidly predict the transient battery performance and to develop a temperature control strategy.

25 ENERGY STORAGE↗