Reactive Burn Model Calibration for Vapor Deposited Hexanitrostilbene and Pentaerythritol Tetranitrate Films Using XHVRB
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Various types of non-light water reactors are currently engaged in the U.S. licensing process. Because of inherent differences compared with well-established large light water reactors, appropriate assessment tools are needed. Specifically, source term analysis, which determines environmental dose impacts from potential accident scenarios, is a crucial part of design and licensing. The U.S. Nuclear Regulatory Commission has emphasized the importance of mechanistic source term analysis for advanced reactor deployments. To align with these needs, Argonne National Laboratory has developed the Simplified Radionuclide Transport (SRT) source term analysis code for metal fuel Sodium-cooled Fast Reactors (SFRs) and microreactors. SRT conducts time-dependent radionuclide transport and retention in SFRs for core and ex-core radionuclide source accident sequences. The main objective of SRT is to provide rapid sensitivity and uncertainty analyses, incorporating parametric uncertainties and summarizing probabilistic results. As part of the code validation process, a study focused on the bubble scrubbing module was performed using an experiment recently carried out by the University of Wisconsin-Madison. Based on the analysis, the modeling approach in SRT provides accurate results for small and large aerosols, while slight underprediction of radionuclide aerosol removal are observed for medium sized aerosols. However, the deviation is minor, considering the highly uncertain phenomenon and range of results, and is in the conservative direction. In addition, uncertainty information derived from the experiments is further implemented, reflecting the actual span of parameters, which leads to enhanced agreement with code predictions. The results demonstrate that SRT provides reasonable predictions for the bubble scrubbing process in sodium pool.
Explore the source record for details and available documents.
Purpose: Transpiration dominates hydrologic fluxes from terrestrial ecosystems to the atmosphere. Sap flow is the most widely used method to quantify transpiration, and calibrations can improve the accuracy of these estimates. Despite numerous suggestions to perform and apply sap flow calibrations, seemingly few reports apply these recommendations. Here, we sought to determine the prevalence of calibration across sap flow methodology. Recent Findings: In this work, we reviewed tree sap flow literature over the past nine years and determined that only 5.3% of these publications documented the performance of calibrations, the application of coefficients from previous calibrations, or the application of correction factors using calibration data to ensure or improve accuracy of transpiration estimates. These data indicate that calibration has not been adopted as a best practice. However, these data may also reflect challenges to the performance and application of calibration indicating fundamental limitations of sap flow methods. Summary: We highlight the need for testing critical assumptions regarding calibration; specifically, that coefficients derived from calibrations on small stems are suitable for application to large stems and that different calibration approaches yield similar transpiration estimates. We encourage researchers to adopt calibration as a best practice for sap flow data and to explain how calibration was performed, how calibration data were applied, and to acknowledge and justify circumstances that preclude or do not necessitate calibration. Without the adoption of calibration and an improved understanding of its limitations, our understanding of transpiration and ability to quantify it using this technology will remain inadequate.
The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.
This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.
This SAND report fulfills the completion requirements for the ASC Physics and Engineering Modeling Level 2 Milestone 7836 during Fiscal Year 2021. The Sandia Simplified potential energy clock (SPEC) non-linear viscoelastic constitutive model was developed to predict a whole host of polymer glass physical behaviors in order to provide a tool to assess the effects of stress on these materials over their lifecycle. Polymer glasses are used extensively in applications such as electronics packaging, where encapsulants and adhesives can be critical to device performance. In this work, the focus is on assessing the performance of the model in predicting material evolution associated with long-term physical aging, an area that the model has not been fully vetted in. These predictions are key to utilizing models to help demonstrate electronics packaging component reliability over decades long service lives, a task that is very costly and time consuming to execute experimentally. The initiating hypothesis for the work was that a model calibration process can be defined that enables confidence in physical aging predictions under ND relevant environments and timescales without sacrificing other predictive capabilities. To test the hypothesis, an extensive suite of calibration and aging data was assembled from a combination of prior work and collaborating projects (Aging and Lifetimes as well as the DoD Joint Munitions Program) for two mission relevant epoxy encapsulants, 828DGEBA/DEA and 828DGEBA/T403. Multiple model calibration processes were developed and evaluated against the entire set of data for each material. A qualitative assessment of each calibration's ability to predict the wide range of aging responses was key to ranking the calibrations against each other. During this evaluation, predictions that were identified as non-physical, i.e., demonstrated something that was qualitatively different than known material behavior, were heavily weighted against the calibration performance. Thus, unphysical predictions for one aspect of aging response could generate a lower overall rating for a calibration process even if that process generated better quantitative predictions for another aspect of aging response. This insurance that all predictions are qualitatively correct is important to the overall aim of utilizing the model to predict residual stress evolution, which will depend on the interplay amongst the different material aging responses. The DSC-focused calibration procedure generated the best all-around aging predictions for both materials, demonstrating material models that can qualitatively predict the whole host of different physical aging responses that have been measured. This step forward in predictive capability comes from an unanticipated source, utilization of calorimetry measurements to specify model parameters. The DSC-focused calibration technique performed better than compression-focused techniques that more heavily weigh measurements more closely related to the structural responses to be predicted. Indeed, the DSC-focused calibration procedure was only possible due to recent incorporation of the enthalpy and heat capacity features into SPEC that was newly verified during this L2 milestone. Fundamentally similar aspects of the two material model calibrations as well as parametric studies to assess sensitives of the aging predictions are discussed within the report. A perspective on the next steps to the overall goal of residual stress evolution predictions under stockpile conditions closes the report.
The WRF-Solar Ensemble Prediction System (WRF-Solar EPS) and a calibration method, the analog ensemble (AnEn), are used to generate calibrated gridded ensemble forecasts of solar irradiance over the contiguous United States (CONUS). Global horizontal irradiance (GHI) and direct normal irradiance (DNI) retrievals, based on geostationary satellites from the National Solar Radiation Database (NSRDB) are used for both calibrating and verifying the day-ahead GHI and DNI predictions (GDIP). A 10-member ensemble of WRF-Solar EPS is run in a re-forecast mode to generate day-ahead GDIP for three years. The AnEn is used to calibrate GDIP at each grid point independently using the NSRDB as the “ground truth”. Performance evaluations of deterministic and probabilistic attributes are carried out over the whole CONUS. The results demonstrate that using the AnEn calibrated ensemble forecast from WRF-Solar EPS contributes to improving the overall quality of the GHI predictions with respect to an AnEn calibrated system based only on the deterministic run of WRF-Solar. In fact, the calibrated WRF-Solar EPS’s mean exhibits a lower bias and RMSE than the calibrated deterministic WRF-Solar. Moreover, using the ensemble mean and spread as predictors for the AnEn allows a more effective calibration than using variables only from the deterministic runs. Finally, it has been shown that the recently introduced algorithm of correction for rare events is of paramount importance to obtain the lowest values of GHI from the calibrated ensemble (WRF-Solar EPS AnEn), qualitatively consistent with those observed from the NSRDB.
Robust estimation of moment magnitude (M w ) can be challenging for Iraq due to the strong lateral heterogeneity across diverse tectonic zones. We aim to improve moment magnitude estimation by investigating the reliability of using a 1D coda envelope model in diverse tectonic zones of different lateral effects and offer a way forward for reliable estimates of M w for small events that are difficult to waveform model. Iraq comprises two main tectonic zones: (1) the Outer platform, consisting of the northwestern Zagros fold-thrust belt and the Mesopotamian foredeep, and (2) the Inner Arabian platform which is overlain by the Iraqi desert. A simple 1D coda envelope model was used because coda waves have a low sensitivity to the source and path heterogeneity. Three separate coda calibrations were conducted to investigate the robustness of a single 1D calibration to fit the country: Whole-region calibration, Zagros calibration, and Mesopotamia calibration. In the whole-region calibration, we used stations from both the Zagros and Mesopotamia zones. In the two other calibration models, we used only stations that were in those particular zones. Ground-truth reference spectra derived from the coda spectral ratio method were used to constrain high-frequency site terms. There was no drastic difference when comparing the moment magnitudes calculated from the waveform modeling and the three calibration models. The results show that the 1D coda envelope model is a reliable method even for a region with diverse tectonic zones. Therefore, we recommend using the whole-region calibration model for moment magnitude estimation that provides more complete path coverage and avoids biases introduced by path correction failures. The proposed calibration is a fundamental step in updating the comprehensive earthquake catalog and probabilistic seismic hazard assessments for Iraq.
Abstract Non‐uniqueness in groundwater model calibration is a primary source of uncertainty in groundwater flow and transport predictions. In this study, we investigate the ability of environmental tracer information to constrain groundwater model parameters. We utilize a pilot point calibration procedure conditioned to subsets of observed data including: liquid pressures, tritium ( 3 H), chlorofluorocarbon‐12 (CFC‐12), and sulfur hexafluoride (SF 6 ) concentrations; and groundwater apparent ages inferred from these environmental tracers, to quantify uncertainties in the heterogeneous permeability fields and infiltration rates of a steady‐state 2‐D synthetic aquifer and a transient 3‐D model of a field site located near Riverton, Wyoming (USA). To identify the relative data worth of each observation data type, the post‐calibration uncertainties of the optimal parameters for a given observation subset are compared to that from the full observation data set. Our results suggest that the calibration‐constrained permeability field uncertainties are largest when liquid pressures are used as the sole calibration data set. We find significant reduction in permeability uncertainty and increased predictive accuracy when the environmental tracer concentrations, rather than apparent groundwater ages, are used as calibration targets in the synthetic model. Calibration of the Riverton field site model using environmental tracer concentrations directly produces infiltration rate estimates with the lowest uncertainties, however; permeability field uncertainties remain similar between the environmental tracer concentration and apparent groundwater age calibration scenarios. This work provides insight on the data worth of environmental tracer information to calibrate groundwater models and highlights potential benefits of directly assimilating environmental tracer concentrations into model parameter estimation procedures.
A plume of the contaminant hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) with concentrations greater than the New Mexico tap water drinking standard (9.66 ppb) is present in the regional aquifer near the southwestern boundary of Los Alamos National Laboratory (LANL). A risk assessment is performed for exposure to regional aquifer groundwater, with long-term predictions of RDX concentrations provided by a calibrated, probabilistic, numerical fate and transport model. The structure of the model is hierarchical, with the RDX Regional Aquifer (RA) groundwater model acting as the primary tool for analysis of downgradient RDX concentrations. The RA model is deeply informed by the conceptual site model (CSM) and is calibrated using site RDX concentration data and hydraulic head measurements, along with other analyses. The model is calibrated using data through December 2019. Where data are scarce other lines of evidence are used to inform inputs, including the multiphase RDX Vadose Zone (VZ) model and Pipe and Disk analytical screening tool. Model inputs are described with informative prior distributions using a robust approach to development that incorporates all available lines of evidence for every parameter used as an input to the RA model. Calibration is performed using a classical nonlinear optimization routine, which is then used to initialize a Bayesian calibration. The Bayesian calibration constrains the uncertainty in the classical calibration, ultimately providing posterior distributions for all model parameters. The challenges of the calibration include high-dimensional parameter space, including spatially heterogeneous hydraulic conductivities, comparatively sparse data, and low RDX concentrations. Posterior parameter distributions developed in the calibration process are then used for stochastic predictive model runs into the future. The result of the forward runs is spatially and temporally explicit estimates of head and concentration with uncertainty at all points in space and time. The probabilistic modeling approach presented here includes innovative computational and statistical methods that leverage high-performance computing (HPC) resources. It makes use of prior modeling work performed at the chromium plume site in the central LANL area, with extensive updates. The risk assessment will ultimately be used to support decision-making at the site, using multiple appropriately weighted sources of information, as well as uncertainty, sensitivity, and value-of-information analyses. (authors)
While there is a clear need for standardized reference materials for analytical calibrations and for inter-laboratory comparisons, there are not currently any for the oxygen stable isotopic composition of uranium oxides. In this paper we summarize the results from four laboratories by seven different methods of oxygen stable isotope analyses using fluorination techniques of CRM 125-A UO 2 Standard Reference Material. We synthesize these data and methods to arrive at a consensus oxygen stable isotope composition for CRM 125-A $δ$ 18 O = -9.63‰ (±0.29‰) VSMOW. We discuss methodological differences between analytical approaches, including furnace vs laser heating, fluorination using BrF 5 or ClF 3 , as well as calibration strategies. We highlight the potential effects of calibration scale compression from single-point calibrations using reference material with $δ$ 18 O values having a large relative difference from the sample being analyzed. We demonstrate how calibration scale compression can yield differences in calibrated $δ$ 18 O values up to ~2‰ for samples with ~20‰ difference from a single reference material, if the calibration slope of different analytical systems differs by 0.1. In conclusion, we suggest the use of liquid water calibration standards sealed in silver capillary tubes for multi-point calibrations of fluorination analysis systems.
SUMMARY Robustness of source parameter estimates is a fundamental issue in understanding the relationships between small and large events; however, it is difficult to assess how much of the variability of the source parameters can be attributed to the physical source characteristics or to the uncertainties of the methods and data used to estimate the values. In this study, we apply the coda method by Mayeda et al. using the coda calibration tool (CCT), a freely available Java-based code (https://github.com/LLNL/coda-calibration-tool) to obtain a regional calibration for Central Italy for estimating stable source parameters. We demonstrate the power of the coda technique in this region and show that it provides the same robustness in source parameter estimation as a data-driven methodology [generalized inversion technique (GIT)], but with much fewer calibration events and stations. The Central Italy region is ideal for both GIT and coda approaches as it is characterized by high-quality data, including recent well-recorded seismic sequences such as L'Aquila (2009) and Amatrice–Norcia–Visso (2016–2017). This allows us to apply data-driven methods such as GIT and coda-based methods that require few, but high-quality data. The data set for GIT analysis includes ∼5000 earthquakes and more than 600 stations, while for coda analysis we used a small subset of 39 events spanning 3.5 < Mw < 6.33 and 14 well-distributed broad-band stations. For the common calibration events, as well as an additional 247 events (∼1.7 < Mw < ∼5.0) not used in either calibration, we find excellent agreement between GIT-derived and CCT-derived source spectra. This confirms the ability of the coda approach to obtain stable source parameters even with few calibration events and stations. Even reducing the coda calibration data set by 75 per cent, we found no appreciable degradation in performance. This validation of the coda calibration approach over a broad range of event size demonstrates that this procedure, once extended to other regions, represents a powerful tool for future routine applications to homogeneously evaluate robust source parameters on a national scale. Furthermore, the coda calibration procedure can homogenize the Mw estimates for small and large events without the necessity of introducing any conversion scale between narrow-band measures such as local magnitude (ML) and Mw, which has been shown to introduce significant bias.
Abstract. The NOAA Global Monitoring Laboratory (GML) measures atmospheric hydrogen (H2) in grab samples collected weekly as flask pairs at over 50 sites in the Cooperative Global Air Sampling Network. Measurements representative of background air sampling show higher H2 in recent years at all latitudes. The marine boundary layer (MBL) global mean H2 was 552.8 ppb in 2021, 20.2 ± 0.2 ppb higher compared to 2010. A 10 ppb or more increase over the 2010–2021 average annual cycle was detected in 2016 for MBL zonal means in the tropics and in the Southern Hemisphere. Carbon monoxide measurements in the same-air samples suggest large biomass burning events in different regions likely contributed to the observed interannual variability at different latitudes. The NOAA H2 measurements from 2009 to 2021 are now based on the World Meteorological Organization Global Atmospheric Watch (WMO GAW) H2 mole fraction calibration scale, developed and maintained by the Max Planck Institute for Biogeochemistry (MPI-BGC), Jena, Germany. GML maintains eight H2 primary calibration standards to propagate the WMO scale. These are gravimetric hydrogen-in-air mixtures in electropolished stainless steel cylinders (Essex Industries, St. Louis, MO), which are stable for H2. These mixtures were calibrated at the MPI-BGC, the WMO Central Calibration Laboratory (CCL) for H2, in late 2020 and span the range 250–700 ppb. We have used the CCL assignments to propagate the WMO H2 calibration scale to NOAA air measurements performed using gas chromatography and helium pulse discharge detector instruments since 2009. To propagate the scale, NOAA uses a hierarchy of secondary and tertiary standards, which consist of high-pressure whole-air mixtures in aluminum cylinders, calibrated against the primary and secondary standards, respectively. Hydrogen at the parts per billion level has a tendency to increase in aluminum cylinders over time. We fit the calibration histories of these standards with zero-, first-, or second-order polynomial functions of time and use the time-dependent mole fraction assignments on the WMO scale to reprocess all tank air and flask air H2 measurement records. The robustness of the scale propagation over multiple years is evaluated with the regular analysis of target air cylinders and with long-term same-air measurement comparison efforts with WMO GAW partner laboratories. Long-term calibrated, globally distributed, and freely accessible measurements of H2 and other gases and isotopes continue to be essential to track and interpret regional and global changes in the atmosphere composition. The adoption of the WMO H2 calibration scale and subsequent reprocessing of NOAA atmospheric data constitute a significant improvement in the NOAA H2 measurement records.
A system for enhanced sequential power system model calibration is provided. The system is programmed to store a model of a device. The model includes a plurality of parameters. The system is also programmed to receive a plurality of events associated with the device, receive a first set of calibration values for the plurality of parameters, generate a plurality of sets of calibration values for the plurality of parameters, for each of the plurality of sets of calibration values, analyze a first event of the plurality of events using a corresponding set of calibration values to generate a plurality of updated sets of calibration values, analyze the plurality of updated sets of calibration values to determine a current updated set of calibration values, and update the model to include the current updated set of calibration values.