Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Electron heated target temperature measurements in petawatt laser experiments based on extreme ultraviolet imaging and spectroscopy

Three independent methods (extreme ultraviolet spectroscopy, imaging at 68 and 256 eV) have been used to measure planar target rear surface plasma temperature due to heating by hot electrons. The hot electrons are produced by ultraintense laser-plasma interactions using the 150 J, 0.5 ps Titan laser. Soft x-ray spectroscopy in the 50-400 eV region and imaging at the 68 and 256 eV photon energies give a planar deuterated carbon target rear surface pre-expansion temperature in the 125-150 eV range, with the rear plasma plume averaging a temperature approximately 74 eV.

07 ISOTOPE AND RADIATION SOURCES↗

Extremum Seeking-Based Control System for Particle Accelerator Beam Loss Minimization

Particle accelerators throughout the world vary widely in terms of age and availability of advanced noninvasive diagnostics that provide varying levels of detail about the accelerated beams. Additionally, beam loss measurements and current monitors are ubiquitous in the accelerator community, they are noninvasive, and they are some of the most important metrics in terms of preventing damage or irradiation of beam pipes and equipment for high-energy machines. However, beam loss and current measurements are difficult to use for feedback tuning because of a lack of a known analytic relationship between scalar loss measurements throughout an accelerator and the hundreds of thousands of parameters that influence the beam and time variation of the beam source itself. In this work, we present a model-independent extremum seeking (ES) controller, which has been implemented for automated tuning and optimization of the Los Alamos Neutron Science Center (LANSCE) linear ion accelerator based only on scalar quantities, such as beam loss or flux measurements. We demonstrate the approach on various accelerator subsystems, including groups of radio frequency (RF) accelerating cavities, quadrupole magnets, bending magnets, and steering magnets. This tool is now available as a use graphical user interface (GUI) in the LANSCE control room, allowing beam physicists to choose arbitrary groups of parameters and beam loss or current monitors for adaptive tuning.

43 PARTICLE ACCELERATORS↗

Time-dependent imaging of space-charge dominated electron beams

When considered as non-neutral plasmas, space-charge dominated charged particle beams have significantly smaller Debye lengths than their beam sizes. Therefore, collective effects due to space-charge forces are very important to the beam dynamics. As an example, density perturbations generated in a space-charge dominated charge particle beam will stimulate longitudinally space-charge waves. To study the modification of transverse beam distributions by longitudinal beam dynamics, experimental studies of low-energy electron beams, with and without longitudinal density perturbations, have been undertaken at the University of Maryland's electron ring and the Long Solenoid Experiment (LSE). We have taken time-resolved beam images on these machines using two different diagnostics: Optical transition radiation, produced from an intercepting aluminized silicon screen, and a fast (<3 ns decay time) phosphor screen. Results from both techniques show that both the transverse size and transverse particle distribution of a space-charge dominated beam are affected by the longitudinal dynamics of the beam. In addition to the fast imaging measurements, longitudinal mean energy profiles of different beams have also been measured at different locations in the LSE system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First measurement of the edge charge exchange recombination spectroscopy on EAST tokamak

An edge toroidal charge exchange recombination spectroscopy (eCXRS) diagnostic, based on a heating neutral beam injection (NBI), has been deployed recently on the Experimental Advanced Superconducting Tokamak (EAST). The eCXRS, which aims to measure the plasma ion temperature and toroidal rotation velocity in the edge region simultaneously, is a complement to the exiting core CXRS (cCXRS). Two rows with 32 fiber channels each cover a radial range from ∼2.15 m to ∼2.32 m with a high spatial resolution of ∼5-7 mm. Charge exchange emission of Carbon VI CVI at 529.059 nm induced by the NBI is routinely observed, but can be tuned to any interested wavelength in the spectral range from 400 to 700 nm. Double-slit fiber bundles increase the number of channels, the fibers viewing the same radial position are binned on the CCD detector to improve the signal-to-noise ratio, enabling shorter exposure time down to 5 ms. One channel is connected to a neon lamp, which provides the real-time wavelength calibration on a shot-to-shot basis. In this paper, an overview of the eCXRS diagnostic on EAST is presented and the first results from the 2015 experimental campaign will be shown. Good agreements in ion temperature and toroidal rotation are obtained between the eCXRS and cCXRS systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Documentation of Air Emissions Source Term for Radionuclide NESHAP Compliance: TA-53 Building 0984 Isotope Production Facility

This paper will document the air emissions source term for the TA-53 Building 0984 Isotope Production Facility (IPF). The facility has historically been managed as a minor source under Radionuclide NESHAP regulations, but began using a wider variety of irradiation targets and a higher beam current. To support expanded generation of actinium-225 for medical diagnostic and therapeutic uses, IPF is now irradiating thorium targets and the beam current is planned to increase from 250 microamperes up to 600 microamperes. These changes merit a review of the anticipated source term under the new proposed operational conditions. The end result of the review indicates the main stack (Exhaust Stack ES-1) needs to be managed as a major source with continuous emissions monitoring. No additional advance notifications or permitting is required as a result of these operational changes.

54 ENVIRONMENTAL SCIENCES↗

Some plasma aspects and plasma diagnostics of ion sources (invited)

We consider plasma properties in the most advanced type of plasma ion sources, electron cyclotron resonance ion sources for highly charged ions. Depending on the operation conditions the plasma in these sources may be highly ionized, which completely changes its transport properties. The most striking difference to weakly ionized plasma is that diffusion will become intrinsically ambipolar. We further discuss means of plasma diagnostics. As noninvasive diagnostic methods we will discuss analysis of the ion beam, optical spectroscopy, and measurement of the x-ray bremsstrahlung continuum. From beam analysis and optical spectroscopy one may deduce ion densities, and electron densities and distribution functions as a mean over the line of sight along the axis (optical spectroscopy) or at the plasma edge (ion beam). From x-ray spectra one obtains information about the population of highly energetic electrons and the energy transfer from the driving electromagnetic waves to the plasma--basic data for plasma modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Longitudinal Space Charge Effects in Bunched Electron Beams Travelling through a Malmberg-Penning Trap

Nanosecond pulsed electron beams in the 1-10 keV energy range have been characterized by means of an electrostatic diagnostic in the Malmberg-Penning trap ELTRAP. The beam length has been inferred through the numerical analysis of the signals measured across the overall load impedance of a planar charge collector. The presence of space charge effects leading to a longitudinal spread of the beam during its transport are evidenced at low injection energies. This feature has also been tested with the use of a one-dimensional fluid model and with two-dimensional, cylindrically-symmetric Particle-In-Cell simulations, whose results are compared to the experimental observations.

43 PARTICLE ACCELERATORS↗

Diagnostics of ballistic electrons in a dc/rf hybrid capacitively coupled discharge

The energy distribution of ballistic electrons in a dc/rf hybrid parallel-plate capacitively coupled plasma reactor was measured. Ballistic electrons originated as secondaries produced by ion and electron bombardment of the electrodes. The energy distribution of ballistic electrons peaked at the value of the negative bias applied to the dc electrode. As that bias became more negative, the ballistic electron current on the rf substrate electrode increased dramatically. The ion current on the dc electrode also increased.

36 MATERIALS SCIENCE↗

Electrodynamics of electron in a superintense laser field: New principles of diagnostics of relativistic laser intensity

The dynamics and energy spectra of electrons driven by a relativistically intense laser pulse are analyzed. The description is based on the numerical solution of the relativistic Newton's equation with the Lorentz force generated by a strong focused optical field. After the interaction with it, electrons retain a considerable fraction of the energy of their oscillations during the interaction. The electron postinteraction energy spectrum is calculated. The energies in the spectrum high-energy tail are determined by the laser pulse intensity at the focal spot. An approach to estimating absolute values of the laser pulse intensity based on the measurement of the energy spectra of the electrons is proposed.

43 PARTICLE ACCELERATORS↗

Time-resolved intensity of ArXXVII resonance line for plasma diagnostics during high pressure gas injection

Paper describes simulations of time-resolved intensity of ArXVII-lines during high pressure gas injection in tokamak. Model consists of two parts: MHD part and CR part. MHD part is based on energy balance equations with special attention to generation of fast electrons and radiation losses. Time-dependent CR part calculates the distribution of Ar0-ArXIX and population of the levels in plasma with opacity effect and diagnostic admixture before injection.The results of calculations of plasma parameters (n{sub e}, n{sub i}, T{sub e}, T{sub i}, radiation peak) are in good agreement with experiments on DIII-D. Calculated time-resolved intensity of w-line (ArXVII) shows high sensitivity to plasma parameters during injection. Presented approach might become an efficient way to understand physics of gas penetration and dissipation of plasma energy within gas injection. Experiment might be carried out using X-ray spectrometer for T{sub i} measurements from Doppler broadening.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NIO1 diagnostics

The radio frequency ion source NIO1, jointly developed by Consorzio RFX and INFN-LNL, will generate a 60kV-135mA hydrogen negative ion beam, composed of 9 beamlets over an area of about 40 × 40 mm{sup 2}. This experiment will operate in continuous mode and in conditions similar to those foreseen for the larger ion sources of the Neutral Beam Injectors for ITER. The modular design of NIO1 is convenient to address the several still open important issues related to beam extraction, optics, and performance optimization. To this purpose a set of diagnostics is being implemented. Electric and water cooling plant related measurements will allow monitoring current, pressure, flow, and temperature. The plasma in the source will be characterized by emission spectroscopy, cavity ring-down and laser absorption spectroscopy. The accelerated beam will be analyzed with a fast emittance scanner, its intensity profile and divergence with beam emission spectroscopy and visible tomography. The power distribution of the beam on the calorimeter will be monitored by thermocouples and by an infrared camera. This contribution presents the implementation and initial operation of some of these diagnostics in the commissioning phase of the experiment, in particular the cooling water calorimetry and emission spectroscopy.

43 PARTICLE ACCELERATORS↗

Simulation of the motional Stark effect diagnostic gas-filled torus calibration

Many motional Stark effect diagnostics around the world make use of a calibration procedure in which the observed neutral beam is injected into a gas-filled torus with known vacuum fields. The instrument is calibrated by reconciling measured angles with vacuum magnetic reconstructions through a range of pitch angles. This in situ gas-filled torus calibration most closely approximates the working conditions of the diagnostic and includes effects such as beam and viewing geometries, beam voltages, Faraday and stress induced birefringence (in most cases) of the transmissive optics, as well as the polarimeter response. However, secondary neutrals, produced after ionization then reneutralization of a beam neutral, have been found to contaminate measured angles by emitting Balmer alpha with similar Doppler shifts and Stark polarizations as beam neutrals, but with different polarization angles. Simulation results that show spectral and angle behavior versus calibration parameters such as fill gas pressure will be presented. Data from NSTX and C-Mod will be compared to simulations results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement techniques using the electron beam profile scanner at the Fermilab Main Injector

This work presents techniques for non-invasive transverse profile measurements of high-intensity proton beams using an Electron Beam Profile Scanner (EBPS). The EBPS utilizes low-energy electrons as a probe to analyze the transverse size of proton beams, allowing for potential analysis on a single-bunch basis. Recent upgrades to the Fermilab Main Injector have enhanced beam power on target to 1 MW, with future developments targeting 2 MW. The higher beam power has increased the demand for non-invasive diagnostics, as invasive methods can disrupt operations.The techniques presented include 1) the slow scan technique, which serves as a proof of concept for the probe beam, 2) the one-shot scan technique for measuring horizontal beam profiles, and 3) the raster scan technique for analyzing horizontal beam profiles as a function of the longitudinal distribution of the beam. The profiles obtained will be crucial for studying and understanding instabilities in high-power, high-intensity proton beams. This will contribute to optimizing the operation of high-power proton accelerators by minimizing beam loss, activation, and damage to both the diagnostics and the accelerator components.

Mwaniki, Matilda [IIT, Chicago]↗

Measurements of the highest acceleration gradient for ions produced with a long laser pulse

Ultrafast plasma light ion streams have been produced using the 300 ps, kJ-class iodine laser, operating at PALS Centre in Prague. Ion detection was performed through standard ion collectors (IC) in time-of-flight configuration (TOF), shielded by thin metallic absorbers. This new diagnostics technique has been theoretically studied and experimentally tested in order to cut the long photopeak contribution and to analyze the ultrafast particle signal. Processing the obtained experimental IC-TOF data, including deconvolution processes of the TOF signals, UV/soft-x-ray photopeak absorption, and ion transmission calculations for different metallic filters, is shown. Mainly amorphous carbon (graphite) targets have been irradiated in order to limit the maximum number of ion charge states and to focus our study on demonstrating the validity of the proposed investigation technique. Maximum ion energy and acceleration gradient estimations as a function of the laser energy and focal spot diameter are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical simulations of impulsively heated solar flares

The response of a model solar atmosphere to heating by an electron beam has been studied for electron beam flux spectra which are power laws with low-energy 'knees' (rising linearly with time to a peak at 30 s and then falling linearly to 0 at 60 s) ranging from 10 to 20 keV. The results indicate that high peak electron beam fluxes, low-energy knees, and larger spectral indices all move the atmospheric response toward greater enhancements of the parameters in the coronal regions of the atmosphere. Coronal responses can thus be used as a diagnostic of the parameters of the electron beam.

Mariska, John T.↗

Development of an X-ray Micro-Laminography System at SPring-8

An x-ray micro-laminography system has been developed at SPring-8 and applied to measurements of planar objects that cannot be observed by x-ray computed tomography. To reconstruct a sectional image parallel to the planar surface, a filtered back-projection technique considering the inclination angle of a rotational axis was developed. Experimental conditions suitable for laminography measurements in this system were investigated. Spatial resolution in the reconstructed plane was almost determined by the detector resolution, while the spatial resolution perpendicular to the planar surface tended to be worse by the artifacts inherent of the laminographic scanning and reconstruction method. A laminated test sample was clearly observed in three dimensions.

07 ISOTOPE AND RADIATION SOURCES↗

Prediction on X-ray output of free electron laser based on artificial neural networks

Abstract Knowledge of x-ray free electron lasers’ (XFELs) pulse characteristics delivered to a sample is crucial for ensuring high-quality x-rays for scientific experiments. XFELs’ self-amplified spontaneous emission process causes spatial and spectral variations in x-ray pulses entering a sample, which leads to measurement uncertainties for experiments relying on multiple XFEL pulses. Accurate in-situ measurements of x-ray wavefront and energy spectrum incident upon a sample poses challenges. Here we address this by developing a virtual diagnostics framework using an artificial neural network (ANN) to predict x-ray photon beam properties from electron beam properties. We recorded XFEL electron parameters while adjusting the accelerator’s configurations and measured the resulting x-ray wavefront and energy spectrum shot-to-shot. Training the ANN with this data enables effective prediction of single-shot or average x-ray beam output based on XFEL undulator and electron parameters. This demonstrates the potential of utilizing ANNs for virtual diagnostics linking XFEL electron and photon beam properties.

47 OTHER INSTRUMENTATION↗

Electron beam and plasma modes of a channel spark discharge operation

Parameters of a modified pulsed channel spark discharge (CSD), operating at a repetition rate up to 100 Hz at Ar gas pressures of 10{sup -3} and 10{sup -4} Torr and of the generated electron beam, were studied using different electrical, optical, and x-ray diagnostics. It was shown that efficient (up to approx74%) transfer of the initially stored energy to the energetic electron beam is realized only at the pressure of 10{sup -4} Torr. Conversely, at the pressure of 10{sup -3} Torr, less than 10% of the stored energy is acquired by the energetic electrons. It was found that the energetic electron beam generation is limited by the expansion of the cathode and anode plasmas and by the formation of plasma inside the gap between the CSD capillary output and the anode. It was also found that the plasma, which acquires the hollow cathode potential, is already formed at the beginning of the CSD operation inside the capillary, and the electron emission occurs from the capillary output plasma boundary. Finally, it was shown that the electron beam energy spectrum differs significantly from the energy spectrum, which one may expect in the case of the planar diode operation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗