Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “atomically precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

Stellar Laboratories II. New Zn Iv and Zn v Oscillator Strengths and Their Validation in the Hot White Dwarfs G191-B2B and RE0503-289

Context. For the spectral analysis of high-resolution and high-signal-to-noise (SN) spectra of hot stars, state-of-the-art non-local thermodynamic equilibrium (NLTE) model atmospheres are mandatory. These are strongly dependent on the reliability of the atomic data that is used for their calculation. In a recent analysis of the ultraviolet (UV) spectrum of the DA-type white dwarf G191B2B,21 Zn iv lines were newly identified. Because of the lack of Zn iv data, transition probabilities of the isoelectronic Ge vi were adapted for a first, coarse determination of the photospheric Zn abundance.Aims. Reliable Zn iv and Zn v oscillator strengths are used to improve the Zn abundance determination and to identify more Zn lines in the spectra of G191B2B and the DO-type white dwarf RE 0503289. Methods. We performed new calculations of Zn iv and Zn v oscillator strengths to consider their radiative and collisional bound-bound transitions in detail in our NLTE stellar-atmosphere models for the analysis of the Zn iv v spectrum exhibited in high-resolution and high-SN UV observations of G191B2B and RE 0503289. Results. In the UV spectrum of G191B2B, we identify 31 Zn iv and 16 Zn v lines. Most of these are identified for the first time in any star. We can reproduce well almost all of them at log Zn 5.52 0.2 (mass fraction, about 1.7 times solar). In particular, the Zn iv Zn v ionization equilibrium, which is a very sensitive Teff indicator, is well reproduced with the previously determined Teff 60 000 2000 K and log g 7.60 0.05. In the spectrum of RE 0503289, we identified 128 Zn v lines for the first time and determined log Zn 3.57 0.2 (155 times solar). Conclusions. Reliable measurements and calculations of atomic data are a pre-requisite for stellar-atmosphere modeling. Observed Zn iv and Zn v line profiles in two white dwarf (G191B2B and RE 0503289) ultraviolet spectra were well reproduced with our newly calculated oscillator strengths. This allowed us to determine the photospheric Zn abundance of these two stars precisely.

strengths↗

Leveraging Qubit Loss Detection in Fault-Tolerant Quantum Algorithms

Qubit loss errors constitute a dominant source of noise in many quantum hardware systems, particularly in neutral-atom quantum computers. We develop a theoretical framework to effectively detect and correct loss errors in logical algorithms and leverage such loss information in decoding. Considering general quantum error correction codes and logical circuits, we introduce a delayed-erasure decoder for experimentally motivated error models which leverages information from delayed loss detection to accurately correct loss errors, even when the precise moment of the error is unknown. Using this decoder, we identify strategies for detecting and correcting loss errors based on the logical circuit structure. For deep circuits prior to logical measurement, we explore methods to integrate loss detection into syndrome extraction with minimal overhead, identifying optimal strategies depending on the qubit loss fraction in the noise and hardware capabilities. In contrast, we find that many key algorithmic subroutines involve frequent gate teleportation, shortening the circuit depth before logical measurement and naturally replacing qubits with no additional experimental overhead. We simulate this setting using a toy model algorithm for small-angle synthesis and find a significant performance improvement as the loss fraction increases. These results provide a path forward for advancing large-scale fault-tolerant quantum computation in systems with loss error detection.

atoms↗

Spectroscopic study and lifetime measurement of the 6d7p 3 F 2 o state of radium

We report a method for the precision measurement of the oscillator strengths and the branching fractions of the decay channels of the 6d7p 3 F 2 o state in 226 Ra. Here, this method exploits a set of metastable states present in Ra, allowing a measurement of the oscillator strengths that does not require knowledge of the number of atoms in the atomic beam. We measure the oscillator strengths and the branching fractions for decays from the 6d7p 3 F 2 o state to the 7s6d 3 D 1 , 7s6d 3 D 2 , and 7s6d 1 D 2 states and constrain the branching fraction to the 7s6d 3 D 3 state to be less than 0.4% (68% confidence limit). The lifetime of the 3 F 2 o state is determined to be 15 ± 4 ns.

74 ATOMIC AND MOLECULAR PHYSICS↗

Real-time signal detection for Cyclotron Radiation Emission Spectroscopy measurements using antenna arrays

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurement of the energies of charged particles, which is being developed by the Project 8 Collaboration to measure the neutrino mass using tritium beta-decay spectroscopy. Project 8 seeks to use the CRES technique to measure the neutrino mass with a sensitivity of 40 meV, requiring a large supply of tritium atoms stored in a multi-cubic meter detector volume. Antenna arrays are one potential technology compatible with an experiment of this scale, but the capability of an antenna-based CRES experiment to measure the neutrino mass depends on the efficiency of the signal detection algorithms. Here, in this paper, we develop efficiency models for three signal detection algorithms and compare them using simulations from a prototype antenna-based CRES experiment as a case-study. The algorithms include a power threshold, a matched filter template bank, and a neural network based machine learning approach, which are analyzed in terms of their average detection efficiency and relative computational cost. It is found that significant improvements in detection efficiency and, therefore, neutrino mass sensitivity are achievable, with only a moderate increase in computation cost, by utilizing either the matched filter or machine learning approach in place of a power threshold, which is the baseline signal detection algorithm used in previous CRES experiments by Project 8.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing for a cosmological influence on local physics using atomic and gravitational clocks

The existence of a possible influence of the large-scale structure of the universe on local physics is discussed. A particular realization of such an influence is discussed in terms of the behavior in time of atomic and gravitational clocks. Two natural categories of metric theories embodying a cosmic infuence exist. The first category has geodesic equations of motion in atomic units, while the second category has geodesic equations of motion in gravitational units. Equations of motion for test bodies are derived for both categories of theories in the appropriate parametrized post-Newtonian limit and are applied to the Solar System. Ranging data to the Viking lander on Mars are of sufficient precision to reveal (1) if such a cosmological influence exists at the level of Hubble's constant, and (2) which category of theories is appropriate for a descripton of the phenomenon.

Adams, P. J.↗

Precise laser frequency scanning using frequency-synthesized optical frequency sidebands - Application to isotope shifts and hyperfine structure of mercury

Based on an efficient broadband electrooptic modulator producing RF optical sidebands locked to a stable cavity, a tunable dye laser can be scanned under computer control with frequency-synthesizer precision. Cavity drift is suppressed in software by using a strong feature in the spectrum for stabilization. Mercury isotope shifts are measured with a reproducibility of about 50 kHz. This accuracy of about 1/300 of the linewidth illustrates the power of the technique. Derived hyperfine-structure constants are compared with previous atomic-beam data.

Rayman, M. D.↗

Propellant-Less Spacecraft Formation-Flying and Maneuvering with Photonic Laser Thrusters

The present NIAC Phase II program explored an amplified photon thruster, Photonic Laser Thruster (PLT), as a means of enabling unprecedented maneuverability of small spacecraft, such as cubesats, and reducing space system SWaP for future NASA missions and other commercial and DoD space endeavors. In addition to its propellantless operation capability, PLT can provide orders of magnitude more precise controls in thrust magnitude and vector than conventional thrusters. Furthermore, PLT promises to enable innovative CONOPS (Concept of Operations) to change how some NASA missions are conceived and to represent a revolutionary departure from the "all-in-one" single-spacecraft approach, where a primary factor that dominates spacecraft design is a heavy and risk-intolerant mission-critical payload. Instead, the PLT CONOPS has evolved from a different path based on interbody dynamics via thrust and power beaming. As interbody atomic dynamics unfolds completely new classes of molecular structures that cannot be formed by solo acting atoms alone, the PLT interbody dynamics is predicted to unfold unprecedented multibody spacecraft structures. Therefore, the revolutionary path of the PLT CONOPS represents a technology push rather than a mission pull, and will enable an entirely new generation of planetary, heliospheric, and Earth-centric missions. The chief accomplishments of the present Phase II program are: 1) achievement of photon thrust up to 3.5 mN (100 times scaling up of Phase I PLT) and amplification factor up to 1,500 (15 times enhancement of Phase I PLT), 2) laboratory demonstration of propelling, slowing and stopping a 1U cubesat on an air track with PLT, 3) proof of feasibility on persistent out-of-plane formation flying with PLT in simulation studies, 4) preliminary SolidWorks designs of 1-mN class PLT, 5) establishment of SWaP for flight-ready PLT, 6) designs for proof-ofconcept missions of precision formation flying with cubesats, 7) definition of PLT-based NASA missions, such as Virtual Telescope. In sum, the present study conclusively demonstrated the potential of PLT to revolutionize future space endeavors by drastically enhancing maneuverability of spacecraft, reducing future space system SWaP by exploiting small spacecraft multi-system, and enabling innovative CONOPS.

Bae, Young K.↗

Improved uranium isotopic ratio determinations for the liquid sampling-atmospheric pressure glow discharge orbitrap mass spectrometer by use of moving average processing

The liquid sampling-atmospheric pressure glow discharge (LS-APGD) is a versatile combined atomic and molecular (CAM) ionization source capable of ionizing elemental species, small polar compounds, low-polarity polycyclic aromatic hydrocarbons, and proteins. While the LS-APGD has been proven capable of determining the 235U/238U isotope ratio in enriched and natural uranium, recent efforts have strived to reduce the analysis time of individual measurements by employing higher-order data processing techniques, specifically, moving average methods. Additionally, the use of a moving average (of data windows of various widths) improves the precision of the ratio measurements and reduces the number of scans needed to be collected to generate high-precision results. Additionally, use of the moving average minimizes the quantity of sample that needs to be analyzed while reducing the measurement time. These reductions have allowed isotope ratio (IR) determinations to be made using injections instead of direct infusion of the analyte. For example, employing a 40-point window width in the moving average to direct infusion data reduced the percent relative standard deviation (% RSD) of the 235U/238U values from 3.4% to 0.5%. For the injection of a 100 μL aliquot, the % RSD was reduced from 5.3% to 0.7%.

74 ATOMIC AND MOLECULAR PHYSICS↗

Stellar Laboratories: 3. New Ba 5, Ba 6, and Ba 7 Oscillator Strengths and the Barium Abundance in the Hot White Dwarfs G191-B2B and RE 0503-289

Context. For the spectral analysis of high-resolution and high-signal-to-noise (S/N) spectra of hot stars, state-of-the-art non-local thermodynamic equilibrium (NLTE) model atmospheres are mandatory. These are strongly dependent on the reliability of the atomic data that is used for their calculation. Aims. Reliable Ba 5-7 oscillator strengths are used to identify Ba lines in the spectra of the DA-type white dwarf G191−B2B and the DO-type white dwarf RE 0503−289 and to determine their photospheric Ba abundances. Methods. We newly calculated Ba v-vii oscillator strengths to consider their radiative and collisional bound-bound transitions in detail in our NLTE stellar-atmosphere models for the analysis of Ba lines exhibited in high-resolution and high-S/N UV observations of G191−B2B and RE 0503−289. Results. For the first time, we identified highly ionized Ba in the spectra of hot white dwarfs. We detected Ba vi and Ba vii lines in the Far Ultraviolet Spectroscopic Explorer (FUSE) spectrum of RE 0503−289. The Ba vi/Ba vii ionization equilibrium is well reproduced with the previously determined effective temperature of 70 000 K and surface gravity of log g=7.5. The Ba abundance is 3.5 +/- 0.5 × 10(exp−4) (mass fraction, about 23 000 times the solar value). In the FUSE spectrum of G191−B2B, we identified the strongest Ba vii line (at 993.41 Å) only, and determined a Ba abundance of 4.0 +/- 0.5 × 10(exp−6) (about 265 times solar). Conclusions. Reliable measurements and calculations of atomic data are a pre-requisite for stellar-atmosphere modeling. Observed Ba vi-vii line profiles in two white dwarfs' (G191−B2B and RE 0503−289) far-ultraviolet spectra were well reproduced with our newly calculated oscillator strengths. This allowed to determine the photospheric Ba abundance of these two stars precisely.

New Ba V↗

Advancing Metasurfaces Towards New Frontiers: Nonvolatile Reconfigurable Optics

The applications of adaptive optics extend across multiple sectors, encompassing areas such as LiDAR, biological and chemical sensing, and free-space communications. In this study, we report on the design, fabrication, testing, and modeling of electrically reconfigurable metasurfaces using a low-loss high contrast phase change material, Ge2Sb2Se4Te integrated with an IR-transparent silicon microheater. Through this work, we introduce a reliable architecture for switching PCM-based metasurfaces within an integrated circuit configuration which is compatible with standard foundry fabrication processes. We demonstrate the capability of controlling the transmission of electromagnetic waves through the precise stimulation of PCM-based pixels, each spanning a few hundred microns, over numerous cycles. By leveraging PCM-based pixels, we unlock the potential to create metasurfaces encompassing a diverse range of functionalities such as dielectric filters, metalens, or beam steering devices, which is governed by the design of the meta-atoms. Further, we perform an in-depth investigation into the failure mechanism utilizing techniques such as Fourier transform IR spectroscopy (FTIR), transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), and thermal modeling. According to our results, due to a sharp temperature rise at the PCM/heater interface, we observe severe delamination of the PCM from the heater. More uniform PCM deposition, better adhesion at the PCM/heater interface, and a more uniform temperature distribution in the device could potentially mitigate the failure and lead to a longer life-time. By addressing these challenges, we aim to unlock the full potential of PCM-based devices and advance the field of adaptive optics.

Phase change material↗

A Hybrid System for High-Accuracy Timekeeping Using Millisecond Pulsars

Millisecond pulsars exhibit extremely stable rotational periods with negligible long-term variation, comparable to atomic clocks. Leveraging pulsar signal stability, this paper presents a hybrid Pulse Per Second (PPS) generation system for high-accuracy and GPS-independent timing. The system combines pulsar and GPS signals through a high-speed data acquisition platform featuring FPGA-driven processing and techniques. This design provides a reliable and precise timekeeping solution for energy systems, ensuring functionality when GPS signals are unavailable.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

Spatial defects nanoengineering for bipolar conductivity in MoS 2

Understanding the atomistic origin of defects in two-dimensional transition metal dichalcogenides, their impact on the electronic properties, and how to control them is critical for future electronics and optoelectronics. Here, we demonstrate the integration of thermochemical scanning probe lithography (tc-SPL) with a flow-through reactive gas cell to achieve nanoscale control of defects in monolayer MoS 2 . The tc-SPL produced defects can present either p- or n-type doping on demand, depending on the used gasses, allowing the realization of field effect transistors, and p-n junctions with precise sub-μm spatial control, and a rectification ratio of over 10 4 . Doping and defects formation are elucidated by means of X-Ray photoelectron spectroscopy, scanning transmission electron microscopy, and density functional theory. We find that p-type doping in HCl/H 2 O atmosphere is related to the rearrangement of sulfur atoms, and the formation of protruding covalent S-S bonds on the surface. Alternatively, local heating MoS 2 in N 2 produces n-character.

36 MATERIALS SCIENCE↗

Physics Division Strategic Plan Fiscal Years 2020-2024

The vision of the Physics Division (PHY) at Argonne National Laboratory is to continue enhancing its role as a world-leading institution in basic nuclear physics research and its applications. Key to this vision is for PHY to continue to safely and effectively operate and evolve the capabilities of the Argonne Tandem Linac Accelerator System (ATLAS) facility to best serve its users. ATLAS is the Department of Energy (DOE) accelerator facility for low-energy nuclear physics research. The research carried out by PHY covers many themes in contemporary science but can be distilled into five areas of focus. These themes are interconnected, with continuously evolving synergies between the various groups and facilities in PHY and the broader Laboratory. This five-year strategic plan serves to illustrate our current capabilities and new directions related to these five areas of focus (ATLAS also develops an independent strategic plan): Accelerator research and design. The goal of this theme is to design, fabricate, test, and implement novel accelerator systems, with a focus on high-intensity ion and electron systems. These R&D activities have led to enhancements in the ATLAS accelerator system. Among others, the division’s accelerator systems are in use or planned for use at Fermilab, the Advanced Photon Source, and in a broad variety of applications at the Facility for Rare Isotope Beams (FRIB). Atom trapping and fundamental symmetries. The goal of this theme is to explore and exploit the uses of advanced laser cooling and trapping techniques to manipulate atoms. There are three main areas of focus. First is in the application of the atom trap trace analysis (ATTA) technique for age determination of groundwater and ice by using radio-krypton dating. The next two trapping-based programs involve tests of fundamental symmetries in nature: the cooling and trapping of radium-225 with the aim of determining limits on an observation of its electric dipole moment and precision measurements of the beta decay properties of helium-6 to set limits on the tensor coupling constant. This is complemented by measurements of similar properties in lithium-8 and boron-8. Nuclear astrophysics. The goal of this theme is to enhance our understanding of how elements are created in the universe via explosive nucleosynthesis and how stars evolve. To meet the challenges of this theme, many of the capabilities of ATLAS are being enhanced, including the development of new beams through a new in-flight separator (RAISOR) and the anticipated neutron-generator upgrade of the Californium Rare Isotope Breeder Upgrade facility (nuCARIBU). These are coupled to state-of-the-art instruments such as the Canadian Penning Trap, Helical Orbit Spectrometer, Gammasphere, GRETINA, Multi-Sampling Ionization Chamber, the Fragment Mass Analyzer, and Argonne Gas-filled Fragment Analyzer, and a new low-background experimental area for decay studies. Nuclear structure. The goal of this theme is to understand the structure of nuclei, both stable and radioactive, in terms of single-particle properties, their shapes, and the dynamics governing reactions between them. These include questions such as what are the limits of nuclear stability and what are the properties of super heavy nuclei. As with the nuclear astrophysics theme, the capabilities of ATLAS, guided by the ATLAS user community, are continuously being enhanced to this end. The Division has strategic initiatives to play a leading role in the development of instrumentation and research programs at the FRIB. Quantum chromodynamics (QCD) and hadron physics. The goal of this theme is to lead major research programs focused on revealing the quark and gluon structure of protons, neutrons, nuclei, and short-lived mesons and baryons. These involve major programs at Jefferson Lab, Fermilab, and smaller facilities. They are complemented by theoretical endeavors centered on the question of how hadrons and their properties emerge from QCD. Out of these activities arise strategic initiatives to play a major role in the forthcoming Electron-Ion Collider (EIC).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Revisiting Experimental Signatures of the Ponderomotive Force

The classical theory of single-electron dynamics in focused laser pulses is the foundation of both the relativistic ponderomotive force (RPF), which underlies models of laser-collective-plasma dynamics, and the discovery of novel strong-field radiation dynamics. Despite this bedrock importance, consensus eludes the community as to whether acceleration of single electrons in vacuum has been observed in experimental conditions. We analyze an early experiment on the RPF with respect to several features that were neglected in modeling and that can restore consistency between theory predictions and experimental data. The right or wrong pulse profile function, laser parameters, or initial electron distribution can each make or break the agreement between predictions and data. The laser phase at which the electron’s interaction with the pulse begins has a large effect, explaining why much larger energies are achieved by electrons liberated in the focal region by photoionization from high-Z atoms and by electrons ejected from a plasma mirror. Finally, we compute the difference in a typical electron spectrum arising from fluctuating focal spot size in state-of-the-art ultra-relativistic laser facilities. Our results emphasize the importance of thoroughly characterizing laser parameters in order to achieve quantitatively accurate predictions and the precision required for discovery science.

Hegelich, Bjorn Manuel↗

Non-contact temperature measurement

Three methods for noncontact temperature measurement are presented. Ideal gas thermometry is realized by using laser-induced fluorescence to measure the concentration of mercury atoms in a Hg-Ar mixture in the vicinity of hot specimens. Emission polarimetry is investigated by measuring the spatially resolved intensities of polarized light from a hot tungsten sphere. Laser polarimetry is used to measure the optical properties, emissivity, and, in combination with optical pyrometry, the temperature of electromagnetically levitated liquid aluminum. The precision of temperature measurements based on the ideal gas law is + or - 2.6 percent at 1500-2000 K. The polarized emission technique is found to have the capability to determine optical properties and/or spectral emissivities of specimens over a wide range of wavelengths with quite simple instruments.

Nordine, Paul C.↗

Toward a Micro Gas Chromatograph/Mass Spectrometer (GC/MS) System

Miniature mass filters (e.g., quadrupoles, ion traps) have been the subject of several miniaturization efforts. A project is currently in progress at JPL to develop a miniaturized Gas Chromatograph/Mass Spectrometer (GC/MS) system, incorporating and/or developing miniature system components including turbomolecular pumps, scroll type roughing pump, quadrupole mass filter, gas chromatograph, precision power supply and other electronic components. The preponderance of the system elements will be fabricated using microelectromechanical systems (MEMS) techniques. The quadrupole mass filter will be fabricated using an X-ray lithography technique producing high precision, 5x5 arrays of quadrupoles with pole lengths of about 3 mm and a total volume of 27 cubic mm. The miniature scroll pump will also be fabricated using X-ray lithography producing arrays of scroll stages about 3 mm in diameter. The target detection range for the mass spectrometer is 1 to 300 atomic mass units (AMU) with are solution of 0.5 AMU. This resolution will allow isotopic characterization for geochronology, atmospheric studies and other science efforts dependant on the understanding of isotope ratios of chemical species. This paper will discuss the design approach, the current state-of-the art regarding the system components and the progress toward development of key elements. The full system is anticipated to be small enough in mass, volume and power consumption to allow in situ chemical analysis on highly miniaturized science craft for geochronology, atmospheric characterization and detection of life experiments applicable to outer planet roadmap missions.

Wiberg, D. V.↗

13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 micrometers

A portable modular gas sensor for measuring the 13C/12C isotopic ratio in CO2 with a precision of 0.8%(+/-1 sigma) was developed for volcanic gas emission studies. This sensor employed a difference frequency generation (DFG)-based spectroscopic source operating at 4.35 micrometers (approximately 2300 cm-1) in combination with a dual-chamber gas absorption cell. Direct absorption spectroscopy using this specially designed cell permitted rapid comparisons of isotopic ratios of a gas sample and a reference standard for appropriately selected CO2 absorption lines. Special attention was given to minimizing undesirable precision degrading effects, in particular temperature and pressure fluctuations.

NASA Discipline Life Sciences Technologies↗