Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “additive construction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57

SHAM beyond clustering: new tests of galaxy–halo abundance matching with galaxy groups

We construct mock catalogs of galaxy groups using subhalo abundance matching (SHAM) and undertake several new tests of the SHAM prescription for the galaxy-dark matter connection. All SHAM models we studied exhibit significant tension with galaxy groups observed in the Sloan Digital Sky Survey (SDSS). The SHAM prediction for the field galaxy luminosity function (LF) is systematically too dim, and the group galaxy LF systematically too bright, regardless of the details of the SHAM prescription. SHAM models connecting r-band luminosity, Mr, to Vacc, the maximum circular velocity of a subhalo at the time of accretion onto the host, faithfully reproduce galaxy group abundance as a function of richness, g(N). However, SHAM models connecting Mr with Vpeak, the peak value of Vmax over the entire merger history of the halo, over-predict galaxy group abundance. Our results suggest that no SHAM model can simultaneously reproduce the observed g(N) and two-point projected galaxy clustering. Nevertheless, we also report a new success of SHAM: an accurate prediction for Phi(m12), the abundance of galaxy groups as a function of magnitude gap m12, defined as the difference between the r-band absolute magnitude of the two brightest group members. We show that it may be possible to use joint measurements of g(N) and Phi(m12) to tightly constrain the details of the SHAM implementation. Additionally, we show that the hypothesis that the luminosity gap is constructed via random draws from a universal LF provides a poor description of the data, contradicting recent claims in the literature. Finally, we test a common assumption of the Conditional Luminosity Function (CLF) formalism, that the satellite LF need only be conditioned by the brightness of the central galaxy. We find this assumption to be well-supported by the observed Phi(m12).

79 ASTRONOMY AND ASTROPHYSICS↗

CORROSION TESTING IN SIMULATED TANK SOLUTIONS

Three simulated waste solutions representing wastes from tanks SY-102 (high nitrate, modified to exceed guidance limits), AN-107, and AY-102 were supplied by PNNL. Out of the three solutions tested, both optical and electrochemical results show that carbon steel samples corroded much faster in SY-102 (high nitrate) than in the other two solutions with lower ratios of nitrate to nitrite. The effect of the surface preparation was not as strong as the effect of solution chemistry. In areas with pristine mill-scale surface, no corrosion occurred even in the SY-102 (high nitrate) solution, however, corrosion occurred in the areas where the mill-scale was damaged or flaked off due to machining. Localized corrosion in the form of pitting in the vapor space of tank walls is an ongoing challenge to overcome in maintaining the structural integrity of the liquid waste tanks at the Savannah River and Hanford Sites. It has been shown that the liquid waste condensate chemistry influences the amount of corrosion that occurs along the walls of the storage tanks. To minimize pitting corrosion, an effort is underway to gain an understanding of the pitting response in various simulated waste solutions. Electrochemical testing has been used as an accelerated tool in the investigation of pitting corrosion. While significant effort has been undertaken to evaluate the pitting susceptibility of carbon steel in various simulated waste solutions, additional effort is needed to evaluate the effect of liquid waste supernates from six Hanford Site tanks (AY-101, AY-102, AN-102, AN-107, SY-102 (high Cl{sup -}), and SY-102 (high nitrate)) on carbon steel. Solutions were formulated at PNNL to replicate tank conditions, and in the case of SY-102, exceed Cl{sup -} and NO{sub 3}{sup -} conditions, respectively, to provide a contrast between in and out of specification limits. The majority of previous testing has been performed on pristine polished samples. To evaluate the actual tank carbon steel surface, efforts are needed to compare the polished surfaces to corroded and mill-scale surfaces, which are more likely to occur in application. Additionally, due to the change in liquid waste levels within the tanks, salt deposits are highly likely to be present along the tank wall. When the level of the tank decreases, a salt deposit will form as the solution evaporates. The effects of this pre-existing salt, or supernate deposit, are unknown at this time on the corrosion effect and thus require investigation. Additionally, in the presence of radiation, moist air undergoes radiolysis, forming a corrosive nitric acid condensate. This condensate could accelerate the corrosion process in the vapor space. To investigate this process, an experimental apparatus simulating the effects of radiation was designed and constructed to provide gamma irradiation while coupons are exposed to a simulate tank solution. Additionally, ammonia vapors will also be introduced to further represent the tank environment.

36 MATERIALS SCIENCE↗

Quantifying Water Storage Change and Land Subsidence Induced by Reservoir Impoundment Using GRACE, Landsat, and GPS Data

The construction of hydropower dams is a common strategy to support a country's increasing need for electricity and river water management for industry and agriculture. Although the hydrological and geophysical impacts of water relocation are usually assessed prior to impoundment, their accuracy is generally limited due to the lack of in situ observations, especially in a remote area. This study presents a workflow to quantify the terrestrial water storage change (TWS) and land subsidence induced by a reservoir's water impoundment using multiple satellite observations (GRACE, Landsat), land surface models (CABLE, GLDAS, NCEP, ECMWF), and GPS data. The study site is the Bakun Dam, located in Sarawak, Malaysia, which is the largest hydropower dam in Southeast Asia. Commencing operation in late 2010, the dam induced a change of water mass and lake surface area that was clearly observed by GRACE and Landsat observations, respectively. During the 17-month impounding period (from August 2010 to December 2011), GRACE observed a dramatic increase of approximately 200 mm equivalent water height, while Landsat detected an increased lake extent of around 600 km2. In this paper, a forward model is developed to determine the increased water surface level corresponding to GRACE observations, estimated to be about 120 m. In contrast to GRACE, the TWS derived from land surface models cannot capture the increased TWS, due to the lack of reservoir routing algorithms in the models. In addition, the land subsidence was calculated using the disk load model constructed based on the GRACE-derived lake level and Landsat-derived lake extent; the result is validated with the GPS data from BIN1 station, located at the western coast of Borneo. The commencement stage of the Bakun Dam induces the large-scale land subsidence, which causes the GPS-BIN1 station to subside by ~9 mm, and move toward the Bakun Lake by ~4 mm. Computation of the surface displacements directly from GRACE spherical harmonic coefficient data fails to capture the subsidence feature, mainly due to the truncation error. Overall, this study demonstrates that evaluating GRACE in conjunction with Landsat, LSMs, and GPS data allows the exploitation of the gravity signal at a much smaller spatial scale than its intrinsic resolution. Benefiting from global coverage, the newly developed satellite-based algorithm is a valuable tool for assessing the impacts of reservoir operation on hydrological and geophysical changes from local to regional scales.

Natthachet Tangdamrongsub↗

Coal desulfurization by low temperature chlorinolysis, phase 2

An engineering scale reactor system was constructed and operated for the evaluation of five high sulfur bituminous coals obtained from Kentucky, Ohio, and Illinois. Forty-four test runs were conducted under conditions of 100 by 200 mesh coal,solvents - methlychloroform and water, 60 to 130 C, 0 to 60 psig, 45 to 90 minutes, and gaseous chlorine flow rate of up to 24 SCFH. Sulfur removals demonstrated for the five coals were: maximum total sulfur removal of 46 to 89% (4 of 5 coals with methylchloroform) and 0 to 24% with water. In addition, an integrated continuous flow mini-pilot plant was designed and constructed for a nominal coal rate of 2 kilograms/hour which will be operated as part of the follow-on program. Equipment flow sheets and design drawings are included for both the batch and continuous flow mini-pilot plants.

Kalvinskas, J. J.↗

High-contrast imaging testbed

Several high-contrast imaging systems are currently under construction to enable the detection of extra-solar planets. In order for these systems to achieve their objectives, however, there is considerable developmental work and testing which must take place. Given the need to perform these tests, a spatially-filtered Shack-Hartmann adaptive optics system has been assembled to evaluate new algorithms and hardware configurations which will be implemented in these future high-contrast imaging systems. In this article, construction and phase measurements of a membrane 'woofer' mirror are presented. In addition, results from closed-loop operation of the assembled testbed with static phase plates are presented. The testbed is currently being upgraded to enable operation at speeds approaching 500 hz and to enable studies of the interactions between the woofer and tweeter deformable mirrors.

99 GENERAL AND MISCELLANEOUS↗

CSP Plant Construction, Start-Up, and O&M Best Practices Study

There are currently 90 operational CSP plants of 10 MW or larger located throughout the world, primarily in Spain, U.S., MENA region, South Africa, and China. In 2018, the U.S. Department of Energy (DOE) funded Solar Dynamics, under subcontract to NREL, to investigate and document lessons learned and best practices associated with the construction, start-up, and operations phases of a majority of these plants. DOE funding for the effort was leveraged by additional funds provided through SolarPACES and the World Bank. This information was obtained by interviewing key stakeholders representing CSP plant owners, operators, construction companies, vendors, technical advisors and financers of these systems, and will be published as an NREL Technical Report at the completion of the project. This paper provides an overview of key challenges facing today's CSP parabolic trough and power tower technologies during all the phases mentioned above.

41 EE - Solar Energy Technologies Office (EE-4S)↗

van der Waals density functionals built upon the electron-gas tradition: Facing the challenge of competing interactions

The theoretical description of sparse matter attracts much interest, in particular for those ground-state properties that can be described by density functional theory. One proposed approach, the van der Waals density functional (vdW-DF) method, rests on strong physical foundations and offers simple yet accurate and robust functionals. A very recent functional within this method called vdW-DF-cx [K. Berland and P. Hyldgaard, Phys. Rev. B 89, 035412 (2014)] stands out in its attempt to use an exchange energy derived from the same plasmon-based theory from which the nonlocal correlation energy was derived. Encouraged by its good performance for solids, layered materials, and aromatic molecules, we apply it to several systems that are characterized by competing interactions. These include the ferroelectric response in PbTiO{sub 3}, the adsorption of small molecules within metal-organic frameworks, the graphite/diamond phase transition, and the adsorption of an aromatic-molecule on the Ag(111) surface. Our results indicate that vdW-DF-cx is overall well suited to tackle these challenging systems. In addition to being a competitive density functional for sparse matter, the vdW-DF-cx construction presents a more robust general-purpose functional that could be applied to a range of materials problems with a variety of competing interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Graph modeling systems and methods

An apparatus and a method for vulnerability and reliability modeling are provided. The method generally includes constructing a graph model of a physical network using a computer, the graph model including a plurality of terminating vertices to represent nodes in the physical network, a plurality of edges to represent transmission paths in the physical network, and a non-terminating vertex to represent a non-nodal vulnerability along a transmission path in the physical network. The method additionally includes evaluating the vulnerability and reliability of the physical network using the constructed graph model, wherein the vulnerability and reliability evaluation includes a determination of whether each terminating and non-terminating vertex represents a critical point of failure. The method can be utilized to evaluate wide variety of networks, including power grid infrastructures, communication network topologies, and fluid distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Renormalization and additional degrees of freedom within the chiral effective theory for spin-1 resonances

We study in detail various aspects of the renormalization of the spin-1 resonance propagator in the effective field theory framework. First, we briefly review the formalisms for the description of spin-1 resonances in the path integral formulation with the stress on the issue of propagating degrees of freedom. Then we calculate the one-loop 1{sup --} meson self-energy within the resonance chiral theory in the chiral limit using different methods for the description of spin-1 particles, namely, the Proca field, antisymmetric tensor field, and the first-order formalisms. We discuss in detail technical aspects of the renormalization procedure which are inherent to the power-counting nonrenormalizable theory and give a formal prescription for the organization of both the counterterms and one-particle irreducible graphs. We also construct the corresponding propagators and investigate their properties. We show that the additional poles corresponding to the additional one-particle states are generated by loop corrections, some of which are negative norm ghosts or tachyons. We count the number of such additional poles and briefly discuss their physical meaning.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Isoreticular Expansion of Metal–Organic Frameworks via Pillaring of Metal Templated Tunable Building Layers: Hydrogen Storage and Selective CO2 Capture

The deliberate construction of isoreticular eea-metal–organic frameworks (MOFs) (Cu-eea-1, Cu-eea-2 and Cu-eea-3) and rtl-MOFs (Co-rtl-1 and Co-rtl-2) has been accomplished based on the ligand-to-axial pillaring of supermolecular building layers. The use of different metal ions resulted in two types of supermolecular building layers (SBLs): Kagome (kgm) and square lattices (sql) which further interconnect to form anticipated 3D-MOFs. The isoreticular expansion of (3,6)-connected Cu-MOFs has been achieved with desired eea-topology based on kgm building layers. In addition, two (3,6)-connected Co-rtl-MOFs were also successfully constructed based on sql building layers. The Cu-eea-MOFs were shown to act as hydrogen storage materials with appreciable amount of hydrogen uptake abilities. Moreover Cu-eea-MOFs have also exhibited remarkable CO2 capture ability at ambient condition compared to nitrogen and methane, due to the presence of amide functionalities.

Maity, Kartik↗

Draft ASME Boiler and Pressure Vessel Code Cases and Technical Bases for Use of Alloy 617 for Constructions of Nuclear Component Under Section III, Division 5

The American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code currently only allows five materials for use in construction of nuclear components for high temperature service. These are: 2.25Cr-1Mo and V-modified 9Cr-1Mo steels, Types 304 and 316 stainless steels and the high nickel Alloy 800H. Since 2005, the US high temperature gas-cooled reactor program has been characterizing elevated temperature mechanical properties of Alloy 617 as the leading candidate construction material for the intermediate heat exchanger. After analysis of these experimental results, along with historical data and additional results available through the Generation IV International Forum, Very High Temperature Reactor, Materials Program Management Board Materials Handbook, a draft ASME Code Case to allow nuclear construction with Alloy 617 for temperatures up to 1750°F (954°C) has been developed. This report contains the Code Case for Low Temperature Service Construction of Section III, Division 5, Subsection HB, Subpart A, Class A and Subsection HC, Subpart A, Class B components, which has been approved in Section II, Materials, and Section III, Rules for Construction of Nuclear Facility Components. Supporting technical justification for the low temperature Code Case is also included. This Code Case allows use of Alloy 617 up to 800°F (425°C). This report also contains an updated draft of a Section III, Division 5, Subsection HB, Subpart B, Class A Code Case for Alloy 617 to qualify it for use in construction of nuclear components up to 1750°F (954°C) for service life up to 100,000 hours. The draft contained in Appendix 4, subject to editorial revision and approval by the ASME Special Task Group on Alloy 617 Code Qualification, will be submitted for approval by letter ballot by the appropriate ASME Committees. The technical justification supporting the Code Case is presented in Appendix 5 of this report. This background document is part of the information package that will be submitted with the Code Case for ballot.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Brigham City Hydro Generation Project

Brigham City owns and operates its own municipal power system which currently includes several hydroelectric facilities. This project was to update the efficiency and capacity of current hydro production due to increased water flow demands that could pass through existing generation facilities. During 2006-2012, this project completed efficiency evaluation as it related to its main objective by completing a feasibility study, undergoing necessary City Council approvals and required federal environmental reviews. As a result of Phase 1 of the project, a feasibility study was conducted to determine feasibility of hydro and solar portions of the original proposal. The results indicated that the existing Hydro plant which was constructed in the 1960’s was running at approximately 77% efficiency or less. Brigham City proposes that the efficiency calculations be refined to determine the economic feasibility of improving or replacing the existing equipment with new high efficiency equipment design specifically for the site. Brigham City completed the Feasibility Assessment of this project, and determined that the Upper Hydro that supplies the main culinary water to the city was feasible to continue with. Brigham City Council provided their approval of feasibility assessment’s results. The Upper Hydro Project include removal of the existing powerhouse equipment and controls and demolition of a section of concrete encased penstock, replacement of penstock just upstream of the turbine inlet, turbine bypass, turbine shut-off and bypass valves, turbine and generator package, control equipment, assembly, start-up, commissioning, Supervisory Control And Data Acquisition (SCADA), and the replacement of a section of conductors to the step-up transformer. Brigham City increased the existing 575 KW turbine and generator with an 825 KW turbine and generator. Following the results of the feasibility assessment Brigham City pursued required environmental reviews with the DOE and the U.S. Fish and Wildlife Services (USFWS) concurring with the National Environmental Policy Act of 1969 (NEPA) It was determined that Brigham City’s Upper Hydroelectric Power Plant upgrade would have no effect to federally listed or candidate species. However Brigham City has contributed a onetime lump sum towards Bonneville cutthroat trout conservation in the Northern Bonneville Geographic Management Unit with the intention to offset any impacts from the Upper Hydro Project needed to move forward with design and construction and is sufficient for NEPA compliance. No work was done in the river or river bank. During construction, the penstock was disconnected and water was diverted through and existing system around the powerhouse and back into the water system. The penstock, which is currently a 30-inch steel pipe, would be removed and replaced with a new section of 30-inch pipe. Brigham City worked with the DOE and was awarded a new modification and the permission to proceed with Phase III of our Hydro Project in Dec. 2013; with the exception to the modification of the award for the construction phase. Brigham City developed and issued a Request for Proposal for Engineer and Design vendor. Sunrise Engineering was selected for the Design and throughout the Construction Phase of the Upper Hydroelectric Power Plant. Brigham City conducted a Kickoff Meeting with Sunrise June 28, 2013 and received a Scope of Work Brigham City along with engineering firm sent out a RFP for Turbine, Generator and Equipment for Upper Hydro. We select Turbine/Generator Equipment from Canyon Industries located in Deming, WA. DOE awarded Brigham City a new modification and the permission to proceed with Phase III Construction of our Hydro Project. Brigham City Crews removed existing turbine/generator and old equipment alone with feeder wires coming into the building basically giving Caribou Construction an empty shell to begin demolition. Brigham City contracted with Caribou Construction from Jerome, Idaho for the Upper Power Plant construction. A kickoff meeting was June 24, 2014 and demolition was immediately started on building. Because of a delivery delay of Turbine, Generator and Equipment from Canyon Brigham City had to request another extension for the final date of completion. DOE awarded modification (.007) to Brigham City with a new completion date of August 1, 2015. The Turbine has had a few adjustments to help with efficiency; but the Generator had a slight vibration when generator got hot so Canyon Industries had U S Motor’s that manufactured the generator come to check out the issue. The other Equipment seems to be running normal. Brigham City, Sunrise Engineering and Canyon Industries met to determine what the vibration in the generator was and how to solve the issue Us Motor’s found some welds that failed: they have been repaired. U S Motor’s delivered the repaired generator Feb. 17, 2015. Canyon Industries arranged for a crane to installed generator in Power Plant. U S Motor’s balanced and wired generator. Plant Operators put the generator back on line. Canyon Industries returned and gave their approval to keep Hydro online. After Hydro was put back into operations it kept going off line because of overheating issues. Canyon Industries returned and replaced sensors and adjusted them to the proper settings for normal operations. Brigham City added additional steel screens to windows to increase air flow in Power Plant Building. After construction phase of the Upper Hydro Plant some landscaping has been restored around the building additional gravel brought in and leveled out and the road that was cut through for conduits to run wires. A retaining wall was installed to protect penstock. The Upper Hydro Plant is complete and in full operations. The final reimbursement was submitted.

13 HYDRO ENERGY↗

Building Specifications

The building in the top photo is the new home of the National Permanent Savings Bank in Washington, D.C., designed by Hartman-Cox Architects. Its construction was based on a money-saving method of preparing building specifications which derived from NASA technology developed to obtain quality construction while holding down cost of launch facilities, test centers and other structures. Written technical specifications spell out materials and components to be used on construction projects and identify the quality tests each item must pass. Specifications can have major impact on construction costs. Poorly formulated specifications can lead to unacceptable construction which must be replaced, unnecessarily high materials costs, safety hazards, disputes and often additional costs due to delays and litigation. NASA's Langley Research Center developed a novel approach to providing accurate, uniform, cost-effective specifications which can be readily updated to incorporate new building technologies. Called SPECSINTACT, it is a computerized - system accessible to all NASA centers involved in construction programs. The system contains a comprehensive catalog of master specifications applicable to many types of construction. It enables designers of any structure to call out relevant sections from computer storage and modify them to fit the needs of the project at hand. Architects and engineers can save time by concentrating their efforts on needed modifications rather than developing all specifications from scratch. Successful use of SPECSINTACT has led to a number of spinoff systems. One of the first was MASTERSPEC, developed from NASA's experience by Production Systems for Architects and Engineers, Inc., an organization established by the American Institute of Architects. MASTERSPEC, used in construction of the bank building pictured, follows the same basic format as SPECSINTACT and can be used in either automated or manual modes. The striking appearance of the bank building shows that, while MASTERSPEC saves time and money, its use involves no sacrfice in architectural design freedom. The Naval Engineering Facilities Command employs an automated specifications system based on SPECSINTACT. The Public Buildings Service of the General Services Administration used SPECSINTACT as a starting point in a plan to make its guideline specifications available to architects and engineers on a nationwide computer network. Public Technology, Inc., a NASA Technology Application Team, is working with Production Systems for Architects and Engineers, Inc., to promote widespread use of the system by state and local governments for cost benefits to taxpayers.

Source record↗

BRIGHT POINTS: MULTITHERMAL ANALYSIS AS A TEST OF STEADY HEATING MODELS

X-ray bright points are small, million-degree features in the solar atmosphere composed of short coronal loops. They are magnetically driven structures associated with photospheric magnetic bipoles. Their relatively small size and simple structure suggest they are ideal candidates for comparisons with coronal heating models. In this paper, we present the analysis of 12 bright points using data from the EUV Imaging Spectrometer on Hinode and the Michelson Doppler Imager on Solar and Heliospheric Observatory. Using the spectroscopy data, we construct differential emission measure (DEM) curves, calculate the electron density, and find DEM-weighted temperatures. In addition, we determine the most likely ionization balance. Using the magnetic field observations, we complete potential field extrapolations of the magnetograms and estimate the loop lengths. Using this information, we construct models assuming the bright points are formed of hundreds of strands, each heated steadily and uniformly. We formulate the models so that the observed emission measure distribution is matched within a few percent. We then compare the densities determined from the models, (1.4-5.0) Multiplication-Sign 10{sup 9}, to those calculated from spectral data, (0.6-2.0) Multiplication-Sign 10{sup 9}. We find the majority of bright points do not agree with steady uniform heating models; instead they are underdense relative to their expected density by a factor of 0.16-0.82.

79 ASTRONOMY AND ASTROPHYSICS↗

Managing wetlands to solve the water crisis in the Katuma River ecosystem, Tanzania

The formerly perennial Katuma River in western Tanzania starts in a protected forest, it then flows through irrigated rice farms before reaching Lake Katavi, a floodplain wetland whose outflow regulates the river flow through the Katavi National Park (KNP) down to its outlet at Lake Rukwa, which has no outlet. In recent years, due to overexploitation of water for irrigation, the Katuma River dried out for up to four months per year and this greatly degraded the KNP ecosystem, the siltation of river lead to flooding of the adjacent areas during heavy rains, and the water level of Lake Rukwa has decreased by 4 m since 1992 while its fishery yield and water quality also deteriorated. In 2016, a total of 46 illegal weirs were removed from the Katuma River upstream of KNP. Following that, the river zero-flow periods were reduced by two months and Lake Rukwa water level rose by 1 m. We suggest that the construction of a low V-notch weir at the outlet of the Lake Katavi wetlands would further reduce the Katuma River zero-flow periods by an additional month, thus returning the river nearly to its former perennial status. The enforcement of regulations governing the construction of irrigation weirs is essential. These ecohydrology solutions do not eliminate the threats, but they amplify the opportunities for sustainable development at the basin scale. This example of active governance of water resources at the basin scale can be applied throughout Tanzania and in semi-arid East Africa in general.

Satellite altimetry↗

A Cassegrain reflector system for compact range applications

An integral part of a compact range is the means of providing a uniform plane wave. A Cassegrain reflector system is one alternative for achieving this goal. Theoretically, this system offers better performance than a simple reflector system. The longer pathlengths in the Cassegrain system lead to a more uniform field in the plane of interest. The addition of the subreflector creates several problems, though. System complexity is increased both in terms of construction and performance analysis. The subreflector also leads to aperture blockage and the orientation of the feed now results in spillover illuminating the target areas as well as the rest of the range. Finally, the addition of the subreflector leads to interaction between the two reflectors resulting in undesired field variations in the plane of interest. These difficulties are addressed and through the concept of blending the surfaces, a Cassegrain reflector system is developed that will provide a uniform plane wave that offers superior performance over large target areas for a given size reflector system. Design and analysis is implemented by considering the main reflector and subreflector separately. Then the system may be put together and the final design and system analysis completed.

Rader, Mark D.↗

Composite Structure Modeling and Analysis of Advanced Aircraft Fuselage Concepts

NASA Environmentally Responsible Aviation (ERA) project and the Boeing Company are collabrating to advance the unitized damage arresting composite airframe technology with application to the Hybrid-Wing-Body (HWB) aircraft. The testing of a HWB fuselage section with Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) construction is presently being conducted at NASA Langley. Based on lessons learned from previous HWB structural design studies, improved finite-element models (FEM) of the HWB multi-bay and bulkhead assembly are developed to evaluate the performance of the PRSEUS construction. In order to assess the comparative weight reduction benefits of the PRSEUS technology, conventional cylindrical skin-stringer-frame models of a cylindrical and a double-bubble section fuselage concepts are developed. Stress analysis with design cabin-pressure load and scenario based case studies are conducted for design improvement in each case. Alternate analysis with stitched composite hat-stringers and C-frames are also presented, in addition to the foam-core sandwich frame and pultruded rod-stringer construction. The FEM structural stress, strain and weights are computed and compared for relative weight/strength benefit assessment. The structural analysis and specific weight comparison of these stitched composite advanced aircraft fuselage concepts demonstrated that the pressurized HWB fuselage section assembly can be structurally as efficient as the conventional cylindrical fuselage section with composite stringer-frame and PRSEUS construction, and significantly better than the conventional aluminum construction and the double-bubble section concept.

Mukhopadhyay, Vivek↗

Internal thermal coupling in direct-flow coaxial vacuum tube collectors

This investigation covers the impact of low flow rates on the efficiency of coaxial vacuum tube collectors. Measurements show an efficiency reduction of 10% if reducing the flow rate from 78 kg/m{sup 2} h to 31 kg/m{sup 2} h for a collector group with 60 parallel vacuum tubes with a coaxial flow conduit at one-sided connection. For a more profound understanding a model of the coaxial tube was developed which defines the main energy fluxes including the internal thermal coupling. The tube simulations show a non-linear temperature profile along the tube with the maximum temperature in the outer pipe. Due to heat transfer to the entering flow this maximum is not located at the fluid outlet. The non-linearity increases with decreasing flow rates. The experimentally determined flow distribution allows simulating the measured collector array. The simulation results confirm the efficiency decrease at low flow rates. The flow distribution has a further impact on efficiency reduction, but even at an ideal uniform flow, a considerable efficiency reduction at low flow rates is to be expected. As a consequence, low flow rates should be prevented for coaxial tube collectors, thus restricting the possible operation conditions. The effect of constructional modifications like diameter or material variations is presented. Finally the additional impact of a coaxial manifold design is discussed. (author)

14 SOLAR ENERGY↗